249-786 DURACELL B30 SIZE C Alkaline Manganese Dioxide Battery MN1400/LR14 + 262mm Max.o SPECIFICATIONS arom td Min. No Load Voltage 1.5V 7.5 mm mexo-s| PS > In. NO g . t Min. On Load Voltage 1.35V on 4.79 1.5 mm Min. at 200ms Rated Capacity 7750 mAh on $0.0 mm Max. 390 - 0.8V 48.5 mm Min. Min. Life 21 Hrs on 3.92 1 Hr/day - 0.8V Volume 26 cm 0.9 mm Max. Weight 67g po - [2.0 mm min oS | ? Typical Discharge Characteristics Voltage Voltage Hours of Service at 20C DURACELL Batteries. Issue 5E To be read in conjunction with the General Information module In line with rts continuing development programme, Duracell reserves the nght to alter specifications without pnor noticeDURACELL Alkaline Manganese Dioxide Battery Time to End Voltage SIZE C MN1400/LR14 Typical 4.6 Characteristics Voltage Discharge 15K ----- eee A-3.90 1Hr/day B-3.9Q 4Min/Hr 8Hrs/day C-6.80 1Hriday Voltage 1.3 0 50 100 150 200 250 300 Hours of Service at 20C Voltage Typical Time to End Voltage curve showing on and off periods Hours of Service at 20C DURACELL Batteries. Issue 5E To be read in conjunction with the General Information module In line with its continuing development programme, Duracell reserves the right to alter specifications without pnor noticeFarnell Order Code 249762, 249774, 249786, 249798, 249804, 249816, 249828 249830, 249841, 249853, 300317, 300329, 300251, 517770 300342, 300366, 300378, 300380, 207925, 207937, 207949 DURACELL iene scene. csiooare Alkaline Manganese Dioxide Battery Product Safety, Transportation and Disposal PR AFETY TI FOR DUIN D DURACELL alkaline manganese cells and batteries will provide long, reliable and safe service when used correctly. To achieve optimum performance and trouble-free operation, the following precautions should be observed. ALWAYS take care to fit batteries correctly, observing the 'plus' and 'minus' signs on the battery and appliance. ALWAYS replace batteries in your equipment with the type and size of DURACELL battery specified by the manufacturer. ALWAYS replace the whole set of batteries at one time. ALWAYS remove dead batteries from equipment. ALWAYS remove batteries from equipment you know you are not going to use for a long time. ALWAYS keep batteries away from small children. If swallowed seek medical advice immediately and contact the DURACELL subsidiary in your country. NEVER mix different types of batteries. NEVER deliberately short-circuit batteries. NEVER take apart, crush, puncttire or mutilate alkaline manganese batteries. NEVER dispose of cells or batteries in fires. DURACELL Batteries. Issue 5JDURACELL Alkaline Manganese Dioxide Battery Product Safety, Transportation and Disposal TI T Batteries should be stored at temperatures between 10C and 25C with relative humidity not exceeding 65%. To maximise shelf life, excessive temperature cycling and storage at temperatures greater than 25C, or less than 10C, should be avoided. Storage of alkaline manganese batteries at lower temperatures is possible, providing care is taken in returning the batteries to room temperature prior to use. Store unused cells and batteries in their packaging and keep away from metal objects which may cause a short-circuit resulting in possible leakage, or in extreme cases an explosion. CHARGING Alkaline manganese cells and batteries are of the primary type and are NOT designed to be recharged. Attempts to recharge these batteries can lead to leakage and possibly an explosion. No responsibility is accepted by DURACELL for injury or damage resulting from the cells having been recharged or otherwise abused. HAZARD I Where alkaline manganese batteries leak, due to misuse, or are taken apart, crushed or punctured, the internal materials will be exposed. The hazards of these materials, together with safety advice is given below. Component Appearance Material Anode Silver grey paste Zinc powder Cathode Black pellet Manganese dioxide/graphite Electrolyte Clear liquid Potassium hydroxide solution DURACELL Batteries. Issue 5JDURACELL Alkaline Manganese Dioxide Battery Product Safety, Transportation and Disposal Hazards: All materials are CORROSIVE (due to the presence of potassium hydroxide solution) and may cause burns to eyes and skin. Additionally, manganese dioxide is HARMFUL by inhalation (when dry) and if swallowed. Safety Advice:In case of contact with skin or eyes rinse immediately with plenty of water and seek medical advice. P WwW HE BAT YIS SW WED MEDICAL ADVICE IMMEDIATELY Note: Alkaline manganese cells and batteries are not subject to EC requirements on the classification, packaging and labelling of dangerous substances or preparations (directives 67/548/EEC and 88/379/EEC as amended) or EC requirements on hazardous substance data sheets (directive 91/155/EEC as amended). TRANSPORTATION There are no special restrictions on the international transportation of alkaline manganese batteries by land (ADR Agreement), rail (RID Regulations), sea MDG Code), or air (ICAO/IATA Regulations). For regulations applying to individual countries, the relevant regulatory authority should be consulted. DURACELL Batteries. Issue 5JDURACELL Alkaline Manganese Dioxide Battery Product Safety, Transportation and Disposal COLLECTION AND HANDLING Where necessary commercial or bulk quantities of spent alkaline manganese cells and batteries should be collected and transported under cover, in leak proof containers and in a manner to prevent compaction, mutilation, or any other physical abuse that would destroy their physical integrity. They should not be exposed to fire or high temperatures. Caution: Cells and batteries which are not fully discharged may leak, vent or explode when subjected to short circuit or other forms of electrical abuse. STORAGE Separately collected spent alkaline manganese batteries should be stored in a well ventilated, covered area, preferably using relatively small heat-resistant plastic containers. Containers should not be hermetically sealed. Note: Guidelines for the disposal of alkaline manganese cells and batteries are continually being revised. Contact your local DURACELL company for further information. DURACELL Batteries. Issue 5JDURACELL Typical Chemical Composition Typical chemical composition, of alkaline batteries, as a percentage of total battery weight: Chemical \ _ Size D C AA AAA N LR43 | LR44 Nominal Weight /g 141 67 22 1] 8.3 1.5 1.9 Mercury None Added 0.6 0.7 Cadmium None Added Lead <0.04 | <0.04 | <0.04 ; <0.04 | <0.04 | <0.04 | <0.04 Zinc 18 17 16 15 1] 8 9 Manganese Dioxide 43 40 37 35 27 26 28 Carbon 5 5 4 4 3 2.2 2.3 Potassium 18 18 17 17 12 9.1 10 Hydroxide Solution Nickel Plated Steel 10 14 17 19 18 28 26 Brass 0.3 0.6 2 5 6 0 0 Plastics l 1 0.2 3 DI ADVI WwW. SWALLOWED DURACELL Batteries. Issue 5JDURACELL Typical Chemical Composition Typical chemical composition, of alkaline batteries, as a percentage of total battery weight: Chemical \ Size | LR54 9V 4.5V | MN11 | MN21 |MN154/MN918 Nominal Weight / g 1.2 45 149 4 7.3 16.3 1,270 Mercury 1.1 None Added 0.17 0.9 0.17 | None Added Cadmium 0.01 None Added Lead 0.003 | <0.04 ; <0.04 } 0.003 | 0.003 | <0.04 | <0.04 Zinc 6 11 16 5.6 6.1 5.4 15 Manganese Dioxide 27 27 36 17.8 19.5 16.8 37 Carbon 2.1 3 4 1.7 1.9 4 Potassium 7.4 12 16 1.2 1.3 4.5 Hydroxide Solution Nickel Plated Steel 32 18 2 43.9 44.5 59 18 Brass 0 6 0 0 0 2.8 Plastics 3 0.2 2 3 2.8 8.9 EK MEDI ADVICE IF PAR SWALLOWED DURACELL Batteries. Issue SJDURACELL Typical Chemical Composition Typical chemical composition, of alkaline batteries, as a percentage of total battery weight: Chemical \ Size | PC908 | PC915 | PC918 | PC926 | 7K67 Nominal Weight / g 612 612 1270 | 1,389 34 Mercury None Added Cadmium None Added Lead <0.04 | <0.04 | <0.04 | <0.04 | <0.04 Zine 15 15 15 15 15 Manganese Dioxide 37 37 37 37 37 Carbon 4 4 4 4 4 Potassium 8 8 8 8 Hydroxide Solution Nickel Plated Steel 18 18 18 18 18 Brass 3 3 3 3 3 Plastics 4 4 4 4 4 DI ADVICE IF PA F SWALLOWED DURACELL Batteries. Issue 5JDURACELL Alkaline Manganese Dioxide Battery Product Safety, Transportation and Disposal DISPOSAL DISPOSAL PROCEDURES DURACELL alkaline manganese cells and batteries contain less than the prescribed amounts of mercury, cadmium and lead, they are not subject to the provisions of the EC directive 91/157/EEC on batteries and accumulators containing certain dangerous substances. However, individual countries may also establish regulations that cover the disposal of waste batteries. These may be more stringent than EC requirements. Thus, local regulatory authorities should be contacted for their disposal guidelines. In the absence of specific regulations or guidelines, the following is recommended for the disposal of DURACELL alkaline manganese cells and batteries. 1. Batteries in household use: Individual alkaline manganese cells and batteries can be disposed of with other domestic waste. 2. Bulk quantities: The recommended procedure for disposal of alkaline manganese cells and batteries is ina hazardous waste landfill. Local regulations, which may specify other methods for the disposal of these batteries supersede these recommendations. Waste management companies can provide assistance with disposal. DURACELL Batteries. Issue 5J