PA
214
PA-RELAYS
THE SLIM POWER RELAY
mm inch
20
.787
5
.197
12.5
.492
FEATURES
• Slim size (width 5 mm .197 inch, height 12.5 mm .492 inch) permits higher density
mounting
Wide switching capacity: Control from 100
µ
A 100 mV to 5 A 250 V AC, 30 V DC
• High sensitivity: 120 mW (Nominal) (5 to 18 V DC type)
• High surge voltage (4000 V) and high breakdown voltage (2000 V)
• Shock & vibration resistance (functional): Min. 147m/s
2
{15 G}
• SIL (single in line) terminal layout
• Reinforced according to IEC1131-2 (TÜV)
SPECIFICATIONS
(at 20
°
C
68
°
F)
Contacts
Coil (at 25
°
C
77
°
F, 50% R.H.)
Remarks
*
Specifications will vary with foreign standards certification ratings.
*
1
Measurement at same location as "Intial breakdown voltage" section
*
2
Detection current: 10mA
*
3
Wave is standard shock voltage of
±
1.2
×
50
µ
s according to JEC-212-1981
*
4
Excluding contact bounce time
*
5
Half-wave pulse of sine wave: 11ms; detection time: 10
µ
s
*
6
Half-wave pulse of sine wave: 6ms
*
7
Detection time: 10
µ
s
*
8
Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 61).
Characteristics
Arrangement 1a
Contact material Gold-clad silver alloy
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A) 30 m
Rating
(resistive)
Nominal switching capacity
5 A 250 V AC, 5 A 30 V DC
Maximum switching power
750 V A, 90 W
Maximum switching voltage
250 V AC, 110 V DC
Max. switching current
5 A
Min. switching capacity
100
µ
A, 100 mV DC
Expected life
(min.
operations)
Mechanical 2
×
10
7
Electrical (at 20 cpm) 3 A 250 V AC, 3 A 30 V DC, 10
5
5 A 250 V AC, 5 A 30 V DC, 5
×
10
4
Nominal operating
power 5 to 18 V DC 120 mW
24 V DC 180 mW
Max. operating speed 20 cpm at rated load
Initial insulation resistance*
1
Min. 1,000 M
at 500 V DC
Initial break-
down
voltage*
2
Between open contacts 1,000 Vrms
Between contacts and coil
2,000 Vrms
Surge voltage between contacts and
coil*
3
4,000 V
Operate time*
4
(at nominal voltage) Approx. 6 ms
Release time (without diode)*
4
(at nominal voltage) Approx. 3 ms
Temperature rise
Max. 45
°
C with nominal coil voltage across
coil and at nominal switching capacity
Shock resistance Functional*
5
Min. 147 m/s
2
{15 G}
Destructive*
6
Min. 980 m/s
2
{100 G}
Vibration resistance Functional*
7
Min. 147 m/s
2
{15 G}, 10 to 55 Hz
at double amplitude of 2.5 mm
Destructive
Min. 205.8 m/s
2
{21 G}, 10 to 55 Hz
at double amplitude of 3.5 mm
Conditions for operation,
transport and storage*
8
(Not freezing and condens-
ing at low temperature)
Ambient
temp.
–40
°
C to +70
°
C –40
°
F to +158
°
F
Humidity 5 to 85%R.H.
Unit weight Approx. 3 g .15 oz
TYPICAL APPLICATIONS
• Interface relays for programmable controllers
• Output relays for measuring equipment, timers, counters and
temperature controllers
• Industrial equipment, office equipment
ORDERING INFORMATION
Note: Standard packing: Tube: 25 pcs.; Case: 1,000 pcs.
UL/CSA, TÜV approved type is standard.
Ex. PA 1a 12V
Contact arrangement
1a: 1 Form A
Coil voltage (DC)
5, 6, 9, 12, 18, 24V
TYPES AND COIL DATA
(at 20
°
C 68
°
F)
*1 Pulse driving
Part No. Nominal
voltage,
V DC
Pick-up
voltage,*
V DC (max.)
Drop-out
voltage,*
V DC (min.)
Nominal opera-
ting current,
mA (
±
10%)
Nominal
operating power,
mW
Coil
resistance,
(
±
10%)
Max. allowable
voltage,
V DC
PA1a-5VV 5 3.5 0.25 24 120 208 6
PA1a-6VV 6 4.2 0.3 20 120 300 7.2
PA1a-9VV 9 6.3 0.45 13.3 120 675 10.8
PA1a-12V 12 8.4 0.6 10 120 1,200 14.4
PA1a-18V 18 12.6 0.9 6.7 120 2,700 21.6
PA1a-24V 24 16.8 1.2 7.5 180 3,200 28.8
PA
215
DIMENSIONS
1. PA relay
General tolerance:
±
0.3
±
.012
mm inch
1.2
.047
0.5
.020 0.8
.031 0.25
.010
1.18
.046
1.11
.044
1.3
.051
2.9
.114
8.8
.346 6
.237
5
.197 10.16
.400
4.8
.189
12.5
(12.8 max.)
.492
(.504 max.)
0.5
.020
3.5
.138
2.54
.100 20
.787
5.08
.200
PC board pattern (Copper-side view)
2.54
.100 10.16
.400 5.08
.200
1.0 dia.
.039 dia.
1.0 dia.
.039dia.
1.2 dia.
.047 dia.
1.2 dia.
.047 dia.
Schematic (Bottom view)
Tolerance:
±
0.1
±
.004
N.O. COM
Coil
2. Socket
PA1a-PS
PA1a-PS
Standard type
1±0.25
.039±.010
1.23
.048
5.08
.200
3.81
.150
6.35
.250
4
.157
5+0.2
.197±.008
9±0.6
.354±.024
5.3±0.6
.209±.024
2.54
.100
0.5
.020 0.8
.031
12 345 6
22.6±0.6
.890±.024
(0.3)
(.012) 0.25
.010
1.23
.048
–0.6
–.024
PA1a-PS-H
Self clinching type
5.08
.200
3.81
.150
6.35
.250
1.3±0.15
.051±.006
3.9
.154 0.8
.031
0.5
.020
2.54
.100
9±0.6
.354±.024
(0.3)
(.012)
5+0.2
.197±.008
12 345 6
22.6±0.6
.890±.024
–0.6
–.024
5.3±0.6
.209±.024
PC board pattern
(Copper-side view)
Tolerance:
±
0.1
±
.004
Self clinching type
2.54
.100
2-1 dia.
2-.039 dia. 2-1.2 dia.
2-.047 dia.
5.08
.200
10.16
.400
Standard type
2.54
.100
2-0.8±0.25 dia.
2-.031±002 dia. 2-1.2±0.05 dia.
2-.047±002 dia.
5.08
.200
10.16
.400
REFERENCE DATA
1. Max. switching capacity 2. Life curve 3.-(1) Coil temperature rise (120 mW)
Sample: PA1a-12V
Ambient temperature: 20
°
C
68
°
F
Measured portion: Inside the coil
0.2
0.3
0.4
0.5
1
2
3
4
5
2030 50 100
200 300
Contact voltage, V
Contact current, A
DC resistive load
AC resistive load
10
20
30
50
100
0.5 1 2 3 5 10 100
Swiching capacity, A
No. of operations, ×104
AC 125 V resistive load
DC 30 V resistive load
AC 250 V resistive load
10
20
30
0
40
50
60
70
80
90
100
100 110 120 130 140 150
3A
5A
Coil applied voltage, %V
Temperature rise, °C
2A
0A
3.-(2) Coil temperature rise (180 mW)
Sample: PA1a-24V
Ambient temperature: 20
°
C
68
°
F
Measured portion: Inside the coil
4.-(1) Operate & release time (120 mW)
Sample: PA1a-12V
No. of samples: n = 20
4.-(2) Operate & release time (180 mW)
Sample: PA1a-24V
No. of samples: n = 20
10
20
30
0
40
50
60
70
80
90
100
100 110 120 130 140 150
3A
5A
Coil applied voltage, %V
Temperature rise, °C
2A
0A
0
1
2
3
4
5
6
7
8
9
10
80 90 100 110 120
Min.
x
Max.
Max.
Min.
Coil applied voltage, %V
Operate & release time, ms
x
Operate time
Release time
0
1
2
3
4
5
6
7
8
9
10
80 90 100 110 120
Max.
x
x
Max.
Min.
Min.
Coil applied voltage, %V
Operate & release time, ms
Operate time
Release time
PA
216
5. Ambient temperature characteristics
Sample: PA1a-12V
No. of samples: n = 6
6. Malfunctional shock
Sample: PA1a-12V
No. of samples: n = 6
–40 –20 0 20 50 75
20
10
–10
–20
–30
–40
30
40
Ambient
temperature, °C
Rate of
change, %
Pick-up voltage
Drop-out voltage
Y
Y’
XZ
Z’ X’
Y’Y
Z’
X
X’
Z
80
60
40
20
40
60
80
100
20
980m/s2Energized
condition
Deenergized
condition
980m/s2
980m/s2
980m/s2
980m/s2
NOTES
1. Specification values for pick-up and
drop-out voltages are for the relay mount-
ing with its terminals below.
2. When mounting the relays within 1 mm.
.039 inch , please notice the condition be-
low.
1) Mount the rela ys in the same direction.
2) Coil terminals (Terminal No. 1 & 2) po-
larity should be arranged in the same di-
rection.
3) Allowable contact current is 2 A.
4) About the electrical life f or close mount-
ing, please refer to data below.
100
90
80
70
60
50
40
30
20
10
0
Max.
Max.
Mounting
direction
Min.
Min.
x
x
Pick-up voltage
Drop-out voltage
Voltage, %V
Within 1 mm
.039 inch
+ .
– .
– .
+ . + .
– . + .
– . + .
– . + .
– .
– .
+ . – .
+ . – .
+ . – .
+ .
AC resistive load
Contact current, A
DC resistive load
Contact voltage, V
20
3.0
2.0
1.0
0.5
0.4
0.3
0.2
30 50 100 200 300
No. of operations, ×104
Switching capacity, A
0.5 1.0 2.0 3.0
50
100
40
30
20
10
AC 125V
resistive load
DC 30 V
resistive load
AC 250 V
resistive load
For Cautions for Use, see Relay Technical Information (Page 48 to 76).
9/1/2000 All Rights Reserved, © Copyright Matsushita Electric Works, Ltd.
Go To Online Catalog