Document Number: 88897 For technical questions within your region, please contact one of the following: www.vishay.com
Revision: 20-Jan-11 DiodesAmericas@vishay.com, DiodesAsia@vishay.com, DiodesEurope@vishay.com 1
Miniature Glass Passivated Junction Rectifier
BY127MGP
Vishay General Semiconductor
FEATURES
Superectifier structure for high reliability
application
Cavity-free glass-passivated junction
Low forward voltage drop
Low leakage current, IR less than 1 μA
High forward surge capability
Meets environmental standard MIL-S-19500
Solder dip 275 °C max. 10 s, per JESD 22-B106
AEC-Q101 qualified
Compliant to RoHS Directive 2002/95/EC and in
accordance to WEEE 2002/96/EC
TYPICAL APPLICATIONS
For use in high voltage rectification of power supplies,
inverters, converters and freewheeling diodes for both
consumer and automotive applications.
MECHANICAL DATA
Case: DO-204AC, molded epoxy over glass body
Molding compound meets UL 94 V-0 flammability rating
Base P/N-E3 - RoHS compliant, commercial grade
Base P/NHE3 - RoHS compliant, AEC-Q101 qualified
Terminals: Matte tin plated leads, solderable per
J-STD-002 and JESD 22-B102
E3 suffix meets JESD 201 class 1A whisker test, HE3 suffix
meets JESD 201 class 2 whisker test
Polarity: Color band denotes cathode end
PRIMARY CHARACTERISTICS
IF(AV) 1.75 A
VRRM 1250 V
IFSM 50 A
IR5.0 μA
VF at IF = 5.0 A 1.5 V
TJ max. 175 °C
DO-204AC (DO-15)
MAXIMUM RATINGS (TA = 25 °C unless otherwise noted)
PARAMETER SYMBOL BY127MGP UNIT
Maximum repetitive peak reverse voltage VRRM 1250 V
Maximum RMS voltage VRMS 875 V
Maximum DC blocking voltage VDC 1250 V
Maximum average forward rectified current
0.375" (9.5 mm) lead length at TA = 55 °C IF(AV) 1.75 A
Peak forward surge current 8.3 ms single half sine wave
superimposed on rated load IFSM 50 A
Maximum full load reverse current, full cycle average,
0.375" (9.5 mm) lead length at TA = 55 °C IR(AV) 100 μA
Operating junction and storage temperature range TJ, TSTG - 65 to + 175 °C
www.vishay.com For technical questions within your region, please contact one of the following: Document Number: 88897
2DiodesAmericas@vishay.com, DiodesAsia@vishay.com, DiodesEurope@vishay.com Revision: 20-Jan-11
BY127MGP
Vishay General Semiconductor
Note
(1) Pulse test: 300 μs pulse width, 1 % duty cycle
Note
(1) Thermal resistance from junction to ambient and from junction to lead at 0.375" (9.5 mm) lead length, P.C.B. mounted
Note
(1) AEC-Q101 qualified
RATINGS AND CHARACTERISTICS CURVES
(TA = 25 °C unless otherwise noted)
Fig. 1 - Forward Current Derating Curve Fig. 2 - Maximum Non-Repetitive Peak Forward Surge Current
ELECTRICAL CHARACTERISTICS (TA = 25 °C unless otherwise noted)
PARAMETER TEST CONDITIONS SYMBOL BY127MGP UNIT
Maximum instantaneous forward voltage IF = 5.0 A VF (1) 1.5 V
Maximum reverse current VR = 1250 V TA = 25 °C IR5.0 μA
Typical reverse recovery time IF = 0.5 A, IR = 1.0 A,
Irr = 0.25 A trr 2.0 μs
Typical junction capacitance 4.0 V, 1 MHz CJ15 pF
THERMAL CHARACTERISTICS (TA = 25 °C unless otherwise noted)
PARAMETER SYMBOL BY127MGP UNIT
Typical thermal resistance
RJA (1) 45
°C/W
RJL (1) 20
ORDERING INFORMATION (Example)
PREFERRED P/N UNIT WEIGHT (g) PREFERRED PACKAGE CODE BASE QUANTITY DELIVERY MODE
BY127MGP-E3/54 0.425 54 4000 13" diameter paper tape and reel
BY127MGP-E3/73 0.425 73 2000 Ammo pack packaging
BY127MGPHE3/54 (1) 0.425 54 4000 13" diameter paper tape and reel
BY127MGPHE3/73 (1) 0.425 73 2000 Ammo pack packaging
25 50 75 100 125 150 175
0
0.5
1.0
1.5
2.0
2.5
3.0
Average Forward Rectied Current (A)
Ambient Temperature (°C)
Single Phase Half Wave
50 Hz Resistive or Inductive Load
0.375" (9.5 mm) Lead Length
110 100
10
20
30
40
60
Number of Cycles at 60 Hz
Peak Forward Surge Current (A)
8.3 ms Single Half Sine-Wave
(JEDEC Method)
50
Document Number: 88897 For technical questions within your region, please contact one of the following: www.vishay.com
Revision: 20-Jan-11 DiodesAmericas@vishay.com, DiodesAsia@vishay.com, DiodesEurope@vishay.com 3
BY127MGP
Vishay General Semiconductor
Fig. 3 - Typical Instantaneous Forward Characteristics
Fig. 4 - Typical Reverse Characteristics
Fig. 5 - Typical Junction Capacitance
Fig. 6 - Typical Transient Thermal Impedance
PACKAGE OUTLINE DIMENSIONS in inches (millimeters)
0.4 0.6 0.8 1.0 1.2 1.4
0.01
0.1
1
10
Instantaneous Forward Voltage (V)
Instantaneous Forward Current (A)
T
J
= 150 °C
T
J
= 25 °C
Pulse Width = 300 μs
2 % Duty Cycle
T
J
= 125 °C
020 40 60 100
0.001
0.01
1
100
Percent of Rated Peak Reverse Voltage (%)
Instantaneous Reverse Current (μA)
TJ = 150 °C
TJ = 25 °C
80
0.1
10
TJ = 125 °C
110 100
1
10
100
Reverse Voltage (V)
Junction Capacitance (pF)
T
J
= 25 °C
f = 1.0 MHz
V
sig
= 50 mV
p-p
0.01 0.1 100
0.1
10
100
t - Pulse Duration (s)
Transient Thermal Impedance (°C/W)
1
10
1
DO-204AC (DO-15)
0.034 (0.86)
0.028 (0.71)
DIA.
0.140 (3.6)
0.104 (2.6)
DIA.
1.0 (25.4)
MIN.
0.300 (7.6)
0.230 (5.8)
1.0 (25.4)
MIN.
Legal Disclaimer Notice
www.vishay.com Vishay
Revision: 12-Mar-12 1Document Number: 91000
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular
product with the properties described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All
operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk and agree
to fully indemnify and hold Vishay and its distributors harmless from and against any and all claims, liabilities, expenses and
damages arising or resulting in connection with such use or sale, including attorneys fees, even if such claim alleges that Vishay
or its distributor was negligent regarding the design or manufacture of the part. Please contact authorized Vishay personnel to
obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Material Category Policy
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the
definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council
of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment
(EEE) - recast, unless otherwise specified as non-compliant.
Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that
all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU.