NOTES: VALID UNLESS OTHERWISE SPECIFIED
1. GENERAL:
a. APPLICATION SPECIFICATION SEE: AS-34062-000
-CONTAINS: PRODUCT INTRODUCTION, PRODUCT SUMMARY,
CONNECTOR ASSEMBLY, PACKAGING INFORMATION, CONNECTOR
MATING, SERVICE INSTRUCTIONS, ELECTRICAL CONTINUITY
CHECKING, CRIMPING, AND TROUBLESHOOTING.
-DESIGNED TO MATE WITH DEVICE CONNECTION AS SPECIFIED IN DRAWING
EWCAP 150-S-002-1-Z01. AVAILIBLE AT http://ewcap.uscarteams.org/.
-DESIGNED TO MATE WITH BLADE SEALED ASSEMBLY AS SPECIFIED
IN DRAWING: SD-34675-001
-ASSEMBLY SHIPPED WITH TPA IN PRE-LOCK
(SEE TPA PRE-LOCK VIEW IN SHEET 4)
b. PRODUCT SPECIFICATION SEE: PS-34062-000
CONTAINS: SCOPE, PRODUCT DESCRIPTION, INTEGRAL COMPONENTS AND
ACCESSORIES, APPLICABLE DOCUMENTS AND SPECIFICATIONS, RATINGS,
PERFORMANCE, PACKAGING, GAUGE AND FIXTURES, AND OTHER INFORMATION.
c. PACKAGING SPECIFICATION PER MOLEX DRAWING: PK-30907-879
d. PARTS MUST BE IN COMPLIANCE TO MOLEX CHEMICAL SUBSTANCES FOR
PRODUCTS AND PACKAGING SPECIFICATION: QEHS-699000-301
e. DATA MUST BE SUBMITTED UNDER THE MOLEX PART NUMBER TO IMDS
(COMPANY ID#13255)
2. DESIGN - MATERIALS:
a. SEE BOM TABLE IN SD-34062-004
3. DESIGN - GEOMETRY:
a. THIS IS A 100% CAD GENERATED PART. THE CAD MATHEMATICAL DATA
IS THE MASTER FOR THIS PART. FOR DIMENSIONAL OR ANY INFORMATION
NOT SHOWN ON THIS DRAWING, ANALYZE THE CAD MODEL.
b. GEOMETRIC DIMENSIONS AND TOLERANCES PER ASME Y14.5M - 1994
c. EDGES AND UNDIMENSIONED DETAILS PER ISO13715
d. CORNERS SHOWN AS SHARP TO BE R 0.2 MAX.
e. LETTERING SHALL BE 0.15 MAX RAISED IN 0.25 MAX RECESS PAD.
THIS INCLUDES RECYCLING CODE, CAVITY ID, VENDOR IDENTIFICATION,
AND CUSTOMER MATERIAL NUMBER.
f. VISUAL DEFECTS SHALL MEET COSMETIC STANDARD PS-45499-002 (Class B)
g. LASER MARKING: TBD
TABLE OF CONTENTS
SHEET NO. SHEET DESCRIPTION
1NOTES
2, 3
CONFIGURATIONS
4
RECEPTACLE CONNECTOR ASSEMBLY
5
MOLEX INTERFACE
J19
NX RE-MASTERING
J18
ADDED DIM ICD 64
REV.
DESCRIPTION
INSPECTION BALLOON NUMBER LOG
PER DRAWING REVISION: J18
LAST BALLOON NUMBER USED: ICD 64
ADDED BALLOON NUMBERS: ICD 64
REMOVED BALLOON NUMBERS: ICD 7, ICD 8, ICD 9,ICD 18,
ICD 19, ICD 20, ICD 41, ICD 42
GENERAL
TOLERANCES
(UNLESS SPECIFIED)
ANGULAR TOL ±
3.0 °
SERIES MATERIAL NUMBER CUSTOMER
GENERAL MARKET
34062
SEE NOTE 2a
4 PLACES
±
3 PLACES
±
2 PLACES
±
0.1
1 PLACE
±
0.3
0 PLACES
±
DRAFT WHERE APPLICABLE
MUST REMAIN
WITHIN DIMENSIONS
THIS DRAWING CONTAINS INFORMATION THAT IS PROPRIETARY TO MOLEX ELECTRONIC TECHNOLOGIES, LLC AND SHOULD NOT BE USED WITHOUT WRITTEN PERMISSION
SHEET NUMBER
1 OF 5
DIMENSION UNITS SCALE
MM 4:1
DRWN BY DATE
KCUNNINGHAM
2011/11/08
CHK'D BY DATE
MVANSLAMBROU
1/26/2012
APPR BY DATE
KDEKOSKI 2017/06/14
DOCUMENT NUMBER
DOC TYPE
DOC PART
SD-34062-002 PSD 000
DRAWING SIZE
THIRD ANGLE PROJECTION
D
MX150 2 WAY CABLE SEAL
RECEPTACLE CONN. SYSTEM (5.0MM PITCH)
PRODUCT CUSTOMER DRAWING
2017/05/15
2017/06/14
117955
PKABBUR
KDEKOSKI
EC NO:
DRWN:
CHK'D:
APPR:
J19
REV
QUALITY
SYMBOLS
=0
=0
=0
=0
=0
=0
=0
=0
FORMAT: master-tb-prod-D
REVISION: G
DATE: 2017/02/06
RELEASE STATUS RELEASE DATE
C
CPA
OPTIONAL
SEE BOM
CONNECTOR HOUSING
FOR OPTIONS SEE BOM
RING SEAL
FOR OPTIONS
SEE BOM
TPA
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
13
13
14
14
15
15
16
16
17
17
18
18
19
19
A A
B B
C C
D D
E E
F F
G G
H H
J J
K K
L L