SPECIFICATION
DR-100-12 DR-100-15 DR-100-24
MODEL
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
OUTPUT VOLTAGE ADJ.RANGE
LINEREGULATION
LOADREGULATION
SETUP,RISETIME
HOLDUP TIME (Typ.)
VOLTAGERANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
ACCURRENT (Typ.)
INPUT
INRUSHCURRENT (Typ.)
SAFETY STANDARDS
HARMONICCURRENT
EMSIMMUNITY
WORKINGHUMIDITY
WORKINGTEMP.
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD Note.6
OVERVOLTAGE
12V 15V 24V
7.5A 6.5A 4.2A
0~7.5A 0~6.5A 0~4.2A
90W 97.5W 100.8W
120mVp-p 120mVp-p 150mVp-p
1.0% 1.0%
15~18V 24~29V12~15V
1.0%
2.0%
1.0% 1.0%
1.0% 1.0% 1.0%
2700ms,80ms/230VAC2700ms,80ms/115VAC atfullload
50ms/230VAC18ms/115VAC atfullload
88~264VAC124~370VDC
47~63Hz
87% 87% 89%
3A/115VAC1.6A/230VAC
COLDSTART 30A/115VAC45A/230VAC
105~135% ratedoutputpower
Protectiontype: Constantcurrentlimiting,recoversautomaticallyafterfaultconditionisremoved
16~20V
Protectiontype:Shutdowno/pvoltage,re-powerontorecover
19~23V 30~35V
-20~+60 (Refertooutputloadderatingcurve)
20~90%RHnon-condensing
-40~+85 ,10~95%RH
0.03%/ (0~50 )
Component:10~500Hz,2G10min./1cycle,60min.eachalongX, Y,Zaxes;Mounting:CompliancetoIEC60068-2-6
486Khrsmin.MIL-HDBK-217F(25 )
100*93*56mm(W*H*D)
0.35Kg;36pcs/13.6Kg/0.89CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Harmonic current test @ 90% load.
6. Under short circuit or overload >150% conditions, output voltage may shut down for 5 sec. and then go into constant current protection mode.
FileName:DR-100-SPEC2010-05-10
CompliancetoEN61204-3,EN55022ClassB
Complianceto EN61000-3-2,-3
CompliancetoEN61000-4-2,3,4,5,6,8,11,ENV50204,EN55024,EN61000-6-2,EN61204-3,heavyindustrylevel,criteria A
100WSingleOutputIndustrialDINRailPowerSupply DR-100 series
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
Isolation class
LED indicator for power on
100% full load burn-in test
3 years warranty
No load power consumption<1W
Features :
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
ENVIRONMENT
PROTECTION
SAFETY &
EMC
(Note4)
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
EMICONDUCTION&RADIATION
I/P-O/P:3KVAC
I/P-O/P:>100MOhms/500VDC/25 /70%RH
UL60950-1, TUVEN60950-1a EN50178pproved,designreferto
..
OVERTEMPERATURE Protectiontype:Shutdowno/pvoltage,re-powerontorecover
90 15 (RTH2)detectonheatsinkofpowertransistor
http://store.iiic.cc/
-20 0 10 20 30 40 45 50 60 70 (VERTICAL)
20
40
60
80
100
BlockDiagram
AMBIENTTEMPERATURE( )
LOAD(%)
MechanicalSpecification
FileName:DR-100-SPEC2010-05-10
TerminalPinNo. Assignment
PinNo. PinNo.
2
1 5,6
3,4
7
8
Assignment Assignment
+V
AC/L
AC/N
-V
LED
+V ADJ.
PWM CIRCUIT
DETECTION
O.L.P.
EMI
FILTER
RECTIFIERS
&
FILTER
POWER
SWITCHING FILTER
&
RECTIFIERS +V
-V
I/P
CONTROL
O.V.P.
DeratingCurveVS AmbientTemperature
INPUTVOLTAGE(VAC)60Hz
88 10095 120110 160140 200180 240220 264
LOAD(%)
Ta=25
90
100
80
70
60
50
40
OutputDeratingVSInputVoltage
230V ACInput
110V ACInput
CaseNo.970A Unit:mm
100WSingleOutputIndustrialDINRailPowerSupply DR-100 series
ADMISSIBLEDIN-RAIL:TS35/7.5OR TS35/15
35
45
68
93
46.5 46.5
8
3
27.4
47
56
555 5
2
4
5
6
3
64.75
1
100
7.5
7
http://store.iiic.cc/