DATASHEET - M22-WK Changeover switch, RMQ-Titan, With thumb-grip, momentary, 2 positions, Bezel: titanium Delivery program Part no. Catalog No. Alternate Catalog No. EL-Nummer (Norway) M22-WK 216865 M22-WKQ 4355316 Product range RMQ-Titan Basic function Selector switch actuators Mounting hole diameter mm 22.5 Single unit/Complete unit Single unit Design With thumb-grip momentary Function: 2 positions Degree of Protection IP66 Front ring Bezel: titanium Connection to SmartWire-DT yes with SWD-RMQ connections Instructions Stay-put/spring-return function, can be changed with coding parts M22-XC-Y Standards IEC/EN 60947 VDE 0660 Lifespan, mechanical Operations x 10 Operating frequency Operations/h 2000 Operating torque (screw terminals) Nm 0.3 Climatic proofing Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 Degree of Protection IP66 Ambient temperature Open C -25 - +70 Storage C - 40 - + 80 Mounting position As required Mechanical shock resistance g 30 Shock duration 11 ms Sinusoidal according to IEC 60068-2-27 shipping classification DNV GL LR 40 Technical data General 6 > 0.1 Indoor and protected outdoor installation 01/13/2021 Eaton 216865 ED2020 V75.0 EN 1/4 Design verification as per IEC/EN 61439 Technical data for design verification Rated operational current for specified heat dissipation In A 0 Heat dissipation per pole, current-dependent Pvid W 0 Equipment heat dissipation, current-dependent Pvid W 0 Static heat dissipation, non-current-dependent Pvs W 0 Heat dissipation capacity Pdiss W 0 Operating ambient temperature min. C -25 Operating ambient temperature max. C 70 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2.4 Resistance to ultra-violet (UV) radiation Please enquire 10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated. 10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated. 10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distances Meets the product standard's requirements. 10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 10.8 Connections for external conductors Is the panel builder's responsibility. 10.9 Insulation properties IEC/EN 61439 design verification 10.9.2 Power-frequency electric strength Is the panel builder's responsibility. 10.9.3 Impulse withstand voltage Is the panel builder's responsibility. 10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility. 10.10 Temperature rise Not applicable. 10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. Technical data ETIM 7.0 Low-voltage industrial components (EG000017) / Front element for selector switch (EC000222) Electric engineering, automation, process control engineering / Low-voltage switch technology / Command and alarm device / Front element for selector switches (ecl@ss10.0.1-27-37-12-13 [AKF031014]) Number of switch positions 2 Type of control element Toggle Suitable for illumination No Colour control element Black Colour indicator light cap Other Construction type lens Round Hole diameter mm 22.5 Width opening mm 0 Height opening mm 0 Switching function latching No Spring-return Yes With front ring Yes Material front ring Plastic Colour front ring Other Degree of protection (IP), front side IP66 01/13/2021 Eaton 216865 ED2020 V75.0 EN 2/4 Degree of protection (NEMA) 4X Product Standards IEC/EN 60947-5; UL 508; CSA-C22.2 No. 14-05; CSA-C22.2 No. 94-91; CE marking UL File No. E29184 UL Category Control No. NKCR CSA File No. 012528 CSA Class No. 3211-03 North America Certification UL listed, CSA certified Degree of Protection UL/CSA Type 3R, 4X, 12, 13 Approvals Dimensions 01/13/2021 Eaton 216865 ED2020 V75.0 EN 3/4 Additional product information (links) IL04716002Z (AWA1160-1745) RMQ-Titan System IL04716002Z (AWA1160-1745) RMQ-Titan System 01/13/2021 https://es-assets.eaton.com/DOCUMENTATION/AWA_INSTRUCTIONS/IL04716002Z2020_09.pdf Eaton Industries GmbH http://www.eaton.eu (c) 12/2020 by Eaton Industries GmbH Eaton 216865 ED2020 V75.0 EN 4/4