UL Recoganized File # E-326243
Glass passivated junction
High case dielectric strength of 1500 Vrms
Typical IR less than 0.1uA
High surge current capability
Mechanical Data GBU100X = Specific Device Code
G = Green Compound
Y = Year
WW = Work Week
Maximum Ratings and Electrical Characteristics
Rating at 25 ℃ ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%
Symbol GBU
1001 GBU
1002 GBU
1003 GBU
1004 GBU
1005 GBU
1006 GBU
1007 Units
VRRM 50 100 200 400 600 800 1000 V
VRMS 35 70 140 280 420 560 700 V
VDC 50 100 200 400 600 800 1000 V
I2TA
2S
uA
uA
Cj pF
TJOC
TSTG OC
Plastic material has Underwriters laboratory
flammability Classification 94V-0
Typical Thermal Resistance (Note 3) RθJA
RθJC
21
2
A
Weight: 4 grams
Type Number
Mounting Torque : 5 in. lb. max
- 55 to + 150
OC/W
GBU1001 - GBU1007
Marking Diagram
GBU
V
200
Single Phase 10.0AMPS. Glass Passivated Bridge Rectifiers
Features
Ideal for printed circuit board
220
Note 3 : Unit case mount on 4" x 6" x 0.25" Al plate heat sink
Operating Temperature Range
Storage Temperature Range - 55 to + 150
Version:D10
Note 2 : Measured at 1MHz and applied Reverse bias of 4.0V DC
Case: Molded plastic body
Maximum DC Reverse Current @ TA=25℃
at Rated DC Blocking Voltage @ TA=125 ℃IR
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Rating of fusing ( t<8.3ms)
IF(AV)
Maximum Average Forward Rectified Current
@TC=100℃
High temperature soldering guaranteed:
260℃/10 seconds at 5 lbs.,(2.3kg) tension
VF1.0
1.1
Dimensions in inches and (millimeters)
Green compound with suffix "G" on packing
code & prefix "G" on datecode
Terminals: Pure tin plated, lead free, solderable
per MIL-STD-202, Method 208
10 A
Peak Forward Surge Current, 8.3 ms Single Half Sine-
wave Superimposed on Rated Load (JEDEC method) IFSM
211 94
Note 1 : Pulse Test with PW=300 usec, 1% Duty Cycle
Maximum Instantaneous Forward Voltage (Note 1)
@ 5 A
@ 10 A
5
500
Typical Junction Capacitance per leg (Note 2)
Pb
RoHS
COMPLIANCE
RoHS