1111-800-526-2324 • www.us.tdk-lambda.com/lp/ Disclaimer: us.tdk-lambda.com/lp/legal.htm
ZWS50-150BAF Series
Features
33W to 150W
Universal Input (85 - 265VAC)
Power factor Corrected
Convection Cooled
5 year warranty
Compact Design
Single Output, High Reliability AC-DC Power Supplies
Notes:
(1) Avoid prolonged operartion in overload
(2) 100 / 200VAC Input
(3) 60°C: 70% load
Model ZWS50BAF ZWS75BAF ZWS100BAF ZWS150BAF
AC Input Voltage range - 85-265VAC (47-63Hz)
DC Input Voltage range - 120 - 370VDC*
Input Current (Typical) A 0.65 / 0.35 0.95 / 0.5 1.3 / 0.65 1.9 / 0.95
Inrush Current A 14 / 28 25°C ambient, cold start
Power Factor (Active) - Meets EN61000-3-2 (Typically 0.97/0.91)
Maximum Ripple and Noise mV 3.3 & 5V: 120mV, 12 to 24V: 150mV, 48V: 200mV
Temperature Coeffi cient - <0.02%/°C
Overcurrent Protection (1) - >105% of maximum output current
Hold Up Time (Typ) at 100VAC ms 20ms
Leakage Current - 0.5mA max, 0.4mA typ at 230VAC
Remote On / Off - None Optional
Operating Temperature (Convection) °C -10 to +70°C, derate linearly to 50% load from 50 to 70°C
Operating Temperature (Forced Air) °C N/A -10 ~+70°C, derate linearly to 75% load from 60 ~70°C
Storage Temperature °C -30 to +75°C
Humidity (non condensing) - Operating: 30 - 90%RH, storage: 10 - 90%RH
Withstand Voltage - I/P to Grnd 2kVAC (10mA), I/P to O/P 3kVAC (10mA), O/P to Grnd 500VAC (20mA) for 1 min.
Isolation Resistance - >100M at 25C & 70%RH, Output to Ground 500VDC
Vibration (non operating) - 10 - 55Hz (1 minute sweep), 19.6m/s2 constant X, Y, Z 1 hour
Shock - < 196.1 m/s2
Safety Agency Certifi cations - UL60950-1, CSA60950-1, EN60950-1, EN50178 (OV II), CE Mark
Conducted & Radiated EMI - EN55011/EN55022-B, FCC-B, VCCI-B
Immunity - IEC61000-4-2 (lv 2,3), -3 (lv3), -4 (lv 3), -5 (lv 3,4), -6 (lv 3), -8 (lv 4), -11
Weight (Typ) g 165 230 290 390
Size (W x H x D) in 1.97 x 1.02 x 5.2” 1.97 x 1.3 x 5.9” 2.44 x 1.3 x 6.1” 2.95 x 1.46 x 6.3”
Warranty yrs Five Years
Specifi cations
Key Market Segments & Applications
*Safety certifi ed for AC input only