A-Series A-Series CIRCUIT BREAKER Well known for their proven reliability, Carling Technologies' A-Series hydraulic magnetic circuit breakers are compact, temperature stable and designed for precision operation in OEM markets requiring general purpose as well as full load amp applications. When front panel operation and aesthetics demand a clean, contemporary design, the visi-rocker or paddle actuators are ideally suitable. A sealed toggle actuator style is also available and ideal for harsh environment applications requiring additional sealing protection. Optional rocker-guard and pushto-reset bezels, which help prevent inadvertent actuation, are also available. 1-6 poles; ratings from 0.02 to 50 amps, up to 277VAC or 80VDC; UL Recognized, UL Listed, UL1500, UL1077, TUV, VDE & CSA Product Highlights: Up to 50 amps in a compact size Various actuator styles Sealed metal toggle option tested to MIL-PRF-55629C. Meets IP68 Requirements Typical Applications: Telecom/Datacom Marine Military Renewable Energy Generators & Welder Carling Technologies, Inc. 60 Johnson Avenue, Plainville, CT 06062 Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: 860.793.9281 Fax: 860.793.9231 www.carlingtech.com 2 | A-Series Circuit Breaker - General Specifications Electrical Maximum Voltage Current Ratings 277VAC 50/60 Hz, 80VDC Standard current coils: 0.100, 0.250, 0.500, 0.750, 1.00, 2.50, 5.00, 7.50, 10.0, 15.0, 20.0, 25.0, 30.0, 35.0, 40.0, 50.0. Other ratings available - consult ordering scheme. Standard Voltage Coils DC-6V, 12V; AC-120V, Other ratings available, consult ordering scheme. Auxiliary Switch Rating SPDT; 10.1 A - 250VAC, 1.0 A-65VDC/0.5 A - 80 VDC, 0.1A - 125VAC (with gold contacts). Insulation Resistance Minimum: 100 Megohms at 500 VDC Dielectric Strength UL, CSA - 1500V 60 Hz for one minute between all electrically isolated terminals. A-Series rocker circuit breakers comply with the 8mm spacing & 3750V dielectric requirements from hazardous voltage to operator accessible surfaces per EN 60950 and VDE 0805. Resistance, Impedance Values from Line to Load Terminal - based on Series Trip Circuit Breaker. RESISTANCE PER POLE VALUES from Line to Load Terminals (Values Based on Series Trip Circuit Breaker) CURRENT TOLERANCE (AMPS) (%) 0.10 - 5.0 5.1 - 20.0 15 25 20.1 - 50.0 35 Pulse Tolerance Curves Mechanical Endurance Trip Free Trip Indication 10,000 ON-OFF operations @ 6 per minute; with rated Current & Voltage. All A-Series Circuit Breakers will trip on overload, even when the actuator is forcibly held in the ON position. The operating actuator moves positively to the OFF position when an overload causes the circuit breaker to trip. When mid-trip handle is specified, the handle moves to the mid position on electrical trip of the circuit breaker. When mid-trip handle with alarm switch is specified, the handle moves to the mid position & the alarm switch actuates when the circuit breaker is electrically tripped. Physical Number of Poles 1 - 6 Poles (handle) and 1-3 poles (rocker) at 30 Amps or less. 1 and 2 poles at 31 Amps thru 50 Amps. Internal Circuit Config. Series, (with or without auxiliary switch), Shunt and Relay with current or voltage trip coils, Dual Coil, Switch Only with or without auxiliary switch. Weight Approximately 65 grams/pole. (Approximately 2.32 ounces/pole) Standard Colors Housing - Black; Actuator- See Ordering Scheme. Environmental Designed and tested in accordance with requirements of specification MIL-PRF-55629 & MIL-STD-202 as follows: Shock Withstands 100 Gs, 6ms, sawtooth while carrying rated current per Method 213, Test Condition "I". Instantaneous and ultra-short curves tested @ 90% of rated current. Vibration Withstands 0.060" excursion from 10-55 Hz, and 10 Gs 55-500 Hz, at rated current per Method 204C, Test Condition A. Instantaneous and ultrashort curves tested at 90% of rated current. Moisture Resistance Method 106D; ten 24-hour cycles @ + 25C to +65C, 80-98% RH.56 days @ +85C, 85% RH. Salt Spray Method 101, Condition A (90-95% RH @ 5% NaCl Solution, 96 hrs). Thermal Shock Method 107D, Condition A (Five cycles @ -55C to +25C to +85C to +25C). Operating Temperature -40 C to +85 C *Manufacturer reserves the right to change product specification without prior notice. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com A-Series Circuit Breaker - General Specifications | 3 Electrical Tables Table A: Lists UL Recognized & CSA Accepted configurations and performance capabilities as a Component Supplementary Protector. A-SERIES TABLE A: COMPONENT SUPPLEMENTARY PROTECTORS Voltage Circuit Configuration Series Max Rating Current Rating Load Frequency Phase Full Amps 32 65 DC DC ----- 80 DC --- 125 125 125 125 / 250 125 / 250 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 1 1 14 13 13 1 250 50 / 60 14 3 Dual Coil 277 32 65 50 / 60 DC DC 1 ----- 80 DC --- 125 50 / 60 1 125 125 / 250 125 / 250 50 / 60 50 / 60 50 / 60 14 13 13 1 1 1 14 250 50 / 60 3 Shunt Relay Switch Only 277 80 125 / 250 50 / 60 DC 50 / 60 250 50 / 60 277 80 125 / 250 50 / 60 DC 50 / 60 250 50 / 60 277 65 80 50 / 60 DC DC 250 50 / 60 277 50 / 60 1 --1 1 3 1 --13 1 3 1 ----1 3 1 0.02 - 15 31 - 50 0.02 - 30 --0.02 - 30 1 - 50 1 - 50 0.02 - 30 0.02 - 50 0.02 - 30 0.02 - 30 --1 - 50 0.02 - 30 31 - 50 0.02 - 30 0.02 - 50 0.02 - 50 0.02 - 30 --0.02 - 30 1 - 50 0.02 - 30 0.02 - 30 0.02 - 50 0.02 - 30 0.02 - 30 --1 - 50 0.02 - 30 31 - 50 0.02 - 30 0.02 - 30 0.02 - 30 0.02 - 30 0.02 - 30 0.02 - 30 0.02 - 30 0.02 - 30 0.02 - 30 0.02 - 30 0.02 - 30 0.02 - 50 0.02 - 30 --0.02 - 50 0.02 - 30 General Purpose Amps ------31 - 50 ----------------------------31 - 50 --------------31 - 50 --------------------------------31 - 50 --31 - 50 Short Circuit Capacity (Amps) UL / CSA With Backup Without Fuse Backup Fuse --5000 --7500 --7500 --7500 --3000 --2000 --1000 --3000 --3000 --1500 --3000 --3000 --1000 5000 2 --2000 1 --5000 1 ----5000 --7500 --7500 --7500 --3000 --2000 --1000 --3000 --3000 --1500 --3000 --3000 --1000 5000 2 --2000 1 --5000 1 ----7500 --3000 --3000 5000 2 --5000 1 ----7500 --3000 --3000 5000 2 --5000 1 --- Application Codes UL CSA TC1, OL1, U2 TC1, 2, OL1, U1 TC1, 2, OL1, U1 TC1, 2, OL0, U1 TC1, OL1, U2 TC1, OL1, U2 TC1, OL1, U2 TC1, 2, OL1, U2 TC1, 2, OL1, U2 TC1, 2, OL0, U2 TC1, OL1, U2 TC1, 2, OL0, U1 TC1, OL1, U2 TC1, 2, OL1, C1 TC1, 2, OL1, C1 TC1, 2, OL1, C1 TC1, OL1, U2 TC1, 2, OL1, U1 TC1, 2, OL1, U1 TC1, 2, OL0, U1 TC1, OL1, U2 TC1, OL1, U2 TC1, OL1, U2 TC1, 2, OL1, U1 TC1, 2, OL1, U2 TC1, OL0, U2 TC1, OL1, U2 TC1, 2, OL0, U1 TC1, OL1, U2 TC1, 2, OL1, C1 TC1, 2, OL1, C1 TC1, 2, OL1, U1 TC1, 2, OL1, U1 TC1, 2, OL1, U1 TC1, 2, OL1, U1 TC1, 2, OL1, C1 TC1, 2, OL1, C1 TC1, 2, OL1, U1 TC1, 2, OL1, U1 TC1, 2, OL1, U1 TC1, 2, OL1, C1 TC1, 2, OL1, C1 TC1, OL1, U2 TC1, 2, OL1, U1 TC1, 2, OL1, U1 TC1, 2, OL0, U1 TC1, OL1, U2 TC1, OL1, U2 TC3, OL1, U3 TC1, 2, OL1, U2 TC1, 2, OL1, U2 TC1, 2, OL0, U2 TC1, OL1, U2 TC1, 2, OL0, U1 TC3, OL1, U3 TC1, 2, OL1, C1 TC1, 2, OL1, C1 TC1, 2, OL1, C1 TC1, OL1, U2 TC1, 2, OL1, U1 TC1, 2, OL1, U1 TC1, 2, OL0, U1 TC1, OL1, U2 TC1, OL1, U2 TC3, OL1, U3 TC1, 2, OL1, U1 TC1, 2, OL1, U2 TC1, OL0, U2 TC1, OL1, U2 TC1, 2, OL0, U1 TC3, OL1, U3 TC1, 2, OL1, C1 TC1, 2, OL1, C1 TC1, 2, OL1, U1 TC1, 2, OL1, U1 TC1, 2, OL1, U1 TC1, 2, OL1, U1 TC1, 2, OL1, C1 TC1, 2, OL1, C1 TC1, 2, OL1, U1 TC1, 2, OL1, U1 TC1, 2, OL1, U1 TC1, 2, OL1, C1 TC1, 2, OL1, C1 not applicable Notes: 1 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse (15A minimum) at no more than 4 times the rating of the protector. 2 Same as note 1, except that backup fuse is limited to 80 A maximum. 3 2 pole protector required (with one pole per power line) for: 125/250 VAC, 1 pole protector required for : 125 VAC, 1O Power System. 4 Satisfies the requirements of clause 11.2.8.2.5 of CSA STD C22.2 No 100 for the use of supplementary protectors with portable generators. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com Construction Notes Rocker Version Rocker Version Handle Single Pole Break Two Pole Break Rocker Version Rocker Version Single Pole Break Two Pole Break 4 | A-Series Circuit Breaker - General Specifications Electrical Tables Table B: Lists UL Recognized, CSA Accepted, VDE & TUV Certified configurations & performance capabilities as a Component Supplementary Protector. 1 3 2 3 2 3 2 Notes: 1 General Purpose Ratings for UL/CSA Only. 2 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse (15A minimum) at no more than 4 times the rating of the protector. 3 Same as note 2, except that backup fuse is limited to 80 A maximum. 4 Satisfies the requirements of clause 11.2.8.2.5 of CSA STD C22.2 No 100 for the use of supplementary protectors with portable generators. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com A-Series Circuit Breaker - General Specifications | 5 Electrical Tables Table C: Lists UL Recognized, CSA Accepted configurations and performance capabilities as Protectors, Supplementary for Marine Electrical and Fuel Systems (Guide PEQZ2, File E75596). Ignition Protected per UL 1500. UL Classified Small Craft Electrical Devices, Marine in accordance with ISO 8846 (Guide UZMK, File MQ1515) as Marine Supplementary Protectors. A-SERIES TABLE C: UL1500 (Marine Ignition Protected) VOLTAGE CIRCUIT CONFIGURATION CURRENT RATING SHORT CIRCUIT CAPACITY (AMPS) APPLICATION CODES MAX. RATING FREQUENCY PHASE FULL LOAD AMPS WITHOUT BACKUP FUSE UL CSA 14 1 DC --- 0.02 - 50 5000 TC1,OL1,U1 TC1,OL1,U1 32 1 65 DC --- 0.02 - 50 5000 TC1,OL1,U2 TC1,OL1,U2 DC --- 0.02 - 50 3000 TC1,OL1,U1 TC1,OL1,U1 125 50 / 60 1 0.02 - 50 3000 TC1,OL1,U2 TC1,OL1,U2 125 / 250 50 / 60 12 0.02 - 50 3000 TC1,OL1,U2 TC1,OL1,U2 250 50 / 60 1 0.02 - 30 1500 TC1,OL1,U1 TC1,OL1,U1 SERIES Notes: Notes: 1 Available with special catalog number only (consult factory). 2 2 pole protector required (with one per power line) for 125 / 250 VAC. 1 pole protector required for 125 VAC 1 phase power system 1 Available with Special Catalog Number Only (consult factory) 2 2 pole protector required (with one per power line) for 125 / 250 VAC. 1 pole protector required for 125 VAC 1 phase power system Table D: Lists UL Listed configurations and performance capabilities as Circuit Breakers for use in Communications Equipment (Guide DITT, File E189195), under UL489A. Notes: 1 Parallel Pole Construction Agency Certifications UL Recognized UL Standard 1077 Component Recognition Program as Protectors Supplementary (Guide CCN/QVNU2, File E75596) CSA Accepted Component Supplementary Protector under Class 3215 30, File 047848 0 000 CSA Standard C22.2 No. 235 UL Standard 508 Switches, Industrial Control (Guide CCN/NRNT2, File E148683) TUV Certified EN60934, under License No. R72103448 UL Standard 1500 Protectors, Supplementary for Marine Electrical & Fuel Systems (Guide PEQZ2, File E75596) Ignition Protection VDE Certified EN60934, VDE 0642 under File No. 10537 UL Listed UL Standard 489A Communications Equipment (Guide CCN/DITT, File E189195) Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com 6 | A-Series Circuit Breaker - Handle UL Recognized - Ordering Scheme A A 3 1 Series 2 Actuator 3 Poles B 0 4 Circuit 10 5 Aux/Alarm Switch 6 Frequency & Delay 1 SERIES A 1 B 1 8 Terminal 9 Actuator Color 10 Mounting/ Barriers C 11 Agency Approval 7 CURRENT RATING (AMPERES) CODE 2 ACTUATOR 1 A Handle, one per pole B Handle, one per multipole unit S Mid-Trip Handle, one per pole T Mid-Trip Handle, one per pole & Alarm Switch 3 POLES 1 One 2 Two 450 7 Current Rating 3 4 5 6 Three Four Five Six 4 CIRCUIT A 2 Switch Only (No Coil) F3 B Series Trip (Current) G3 C Series Trip (Voltage) H 3,4 D 3 Shunt Trip (Current) E 3 Shunt Trip (Voltage) K 3,4 Relay Trip (Current) Relay Trip (Voltage) Dual Coil with Shunt Trip Voltage Coil Dual Coil with Relay Trip Voltage Coil 5 AUXILIARY / ALARM SWITCH 5 5 0 without Aux Switch 1 S.P.D.T., 0.093 Q.C. Term. 7 2 S.P.D.T., 0.110 Q.C. Term. 4 S.P.D.T., 0.110 Q.C. Term. 8 (Gold Contacts) 9 S.P.S.T., 0.093 Q.C. Term. (Gold Contacts) S.P.S.T., 0.110 Q.C. Term. (Gold Contacts) S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. 6 FREQUENCY & DELAY 03 DC 50/60Hz, Switch Only 10 DC Instantaneous 11 DC Ultra Short 12 DC Short 14 DC Medium 16 DC Long 20 50/60Hz Instantaneous 21 50/60Hz Ultra Short 22 50/60Hz Short 24 50/60Hz Medium 26 50/60Hz Long 30 31 32 34 36 42 7 44 7 46 7 52 7 54 7 56 7 DC, 50/60Hz Instantaneous DC, 50/60Hz Ultra Short DC, 50/60Hz Short DC, 50/60Hz Medium DC, 50/60Hz Long 50/60Hz Short, Hi-Inrush 50/60Hz Medium, Hi-Inrush 50/60Hz Long, Hi-Inrush DC, Short,Hi-Inrush DC, Medium, Hi-Inrush DC, Long, Hi-Inrush Notes: 1 Actuator Code: A: Handle tie pin spacer(s) and retainers provided un-assembled with multi-pole units. B: Handle location as viewed from front of breaker: 2 pole - left pole 3 pole - center pole 4 pole - two handles at center poles 5 pole - three handles at center poles 6 pole - four handles at center poles S: Handle moves to mid-position only upon electrical trip of the breaker. Available with circuit codes B, C, D, E, F, G, H and K. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. Available with circuit codes B & C. 2 Switch Only circuits, rated up to 50 amps and 6 poles, and only available when tied to a protected pole (Circuit Code B, C, D or H.), For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. 3 Available with terminal Codes 1, 2 and 3. Current Rating limited to 50A amps maximum. 4 Consult factory for available Dual Coil options, as special catalog number is required. With Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils require 30VA minimum power to trip and are rated for intermittent duty only. 5 Auxiliary Switch breakers with Series Trip & Switch Only circuits: 30A - supplied with standard half shells. 35-50A - supplied with extended boat (B-Style) half shells. On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 6 Separate pole type voltage coils not rated for continuous duty. Available only with delay codes 10 and 20. 7 Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized, CSA Accepted & TUV Certified to 50 amps. 8 VDE Certification available with single pole breakers with DC Delay only. UL Recognition and CSA Accepted available in one and two pole breakers. 9 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G, H, M and Q.. 10 Terminal Code 1: VDE Certification up to 25 amps and UL Recognition and CSA Certification up to 30 amps, but not recommended over 20 amps. 11 Terminal Codes 3, 5, E and H (Bus Type) with VDE, are supplied with Lock Washers, and Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only VDE Certified when the washers are used. 12 Terminal Code L: VDE Certified available up to 12A. UL Recognized & CSA Accepted available up to 30A. 13 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps with VDE Certification and 50 amps with UL Recognition and CSA Accepted, with Circuit Codes A, B and C. Two pole breakers with Terminal Code P (Printed Circuit Board) are available up to 40 amps with UL Recognition and CSA Accepted with Circuit Codes A, B and C. 14 Terminal Code Q not available with VDE certification. 15 Single pole only. AMPERES 020 0.020 225 0.250 420 2.000 025 0.025 230 0.300 522 2.250 030 0.030 235 0.350 527 2.750 035 0.035 240 0.400 430 3.000 040 0.040 245 0.450 435 3.500 045 0.045 250 0.500 440 4.000 050 0.050 255 0.550 445 4.500 055 0.055 260 0.600 450 5.000 060 0.060 265 0.650 455 5.500 065 0.065 270 0.700 460 6.000 070 0.070 275 0.750 465 6.500 075 0.075 280 0.800 470 7.000 080 0.080 285 0.850 475 7.500 085 0.085 290 0.900 480 8.000 090 0.090 295 0.950 485 8.500 095 0.095 410 1.000 490 9.000 210 0.100 512 1.250 495 9.500 215 0.150 415 1.500 610 10.000 220 0.200 517 1.750 710 10.500 OR VOLTAGE COIL (NORMAL RATED VOLTAGE) 6 611 711 612 712 613 614 615 616 617 618 620 622 624 625 630 635 8 640 8 645 8 650 8 11.000 11.500 12.000 12.500 13.000 14.000 15.000 16.000 17.000 18.000 20.000 22.000 24.000 25.000 30.000 35.000 40.000 45.000 50.000 A06 A12 A18 A24 J65 K20 L40 65 AC 120 AC 240 AC CODE AMPERES 6 DC 12 DC 18 DC 24 DC A32 A48 A65 J06 32 DC 48 DC 65 DC 6 AC J12 J18 J24 J48 8 TERMINAL 9 1 10 Push-On 0.250 Tab (Q.C.) E 11 2 Screw 8-32 with upturned lugs F 11 3 Screw 8-32 (Bus Type) 4 Screw 10-32 with upturned lugs G 11 5 Screw 10-32 (Bus Type) H 11 6 Screw 8-32 with upturned lugs L 12 & 30 bend M 11 7 Screw 8-32 (Bus Type) Q 14 & 30 bend R 8 Screw 10-32 with upturned lugs & 30 bend T 11 9 Screw 10-32 (Bus Type) & 30 bend P 13 B Screw M5 with upturned lugs S 13 C Screw M4 with upturned lugs 9 ACTUATOR COLOR & LEGEND Actuator Color I-O White A Black C Red F Green H Blue K Yellow M Gray P Orange R Black (short handle)15 T 12 AC 18 AC 24 AC 48 AC Screw M4 (Bus Type) Screw M5 with upturned lugs & 30 bend Screw M5 (Bus Type) & 30 bend Screw M5 (Bus Type) 0.250 Q.C./ Solder Lug M6 Threaded Stud Push-In Stud Screw M4 with upturned lugs & 30 bend Screw M4 (Bus Type) & 30 bend Printed Circuit Board Terminals Push-On 0.110 Tab (Q.C.) ON-OFF B D G J L N Q S U Dual 1 2 3 4 5 6 7 8 9 10 MOUNTING / BARRIERS MOUNTING STYLE Threaded Insert, 2 per pole 1 6-32 x 0.195 inches A 6-32 x 0.195 inches 2 ISO M3 x 5mm B ISO M3 x 5mm (multipole only) Front panel Snap-In, 0.75" wide bezel 5 without Handleguard 6 without Handleguard (multipole only) Front panel Snap-In, 0.96" wide bezel 7 without Handleguard, 1-pole 0.96" wide; multipole units have .105" bezel overhang on all sides 8 without Handleguard, 1-pole 0.96" wide; (multipole only) .105" bezel overhang on all sides Legend Color Black White White White White Black Black Black White BARRIERS no yes no yes no yes no yes 11 AGENCY APPROVAL C UL Recognized & CSA Accepted D VDE Certified, UL Recognized & CSA Accepted E TUV Certified, UL Recognized & CSA Accepted I UL Recognized STD 1077, UL Recognized 1500 (ignition protected), & CSA Accepted Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com A-Series Circuit Breaker - Handle UL489A - Ordering Scheme | 7 A A 1 1 Series 2 Actuator B 0 4 Circuit 3 Poles 5 Aux/Alarm Switch 14 6 Frequency & Delay 2 ACTUATOR 1 A Handle, one per pole S Mid-Trip Handle, one per pole T Mid-Trip Handle, one per pole & Alarm Switch 3 POLES 2 1 One 2 Two 3 Three 4 Four 4 CIRCUIT B Series Trip (Current) 6 FREQUENCY & DELAY 11 DC Ultra Short 12 DC Short 14 DC Medium 16 DC Long S.P.S.T., 0.110 Q.C. Term. (Gold Contacts) S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. 52 3 DC, Short,Hi-Inrush 54 3 DC, Medium, Hi-Inrush 56 3 DC, Long, Hi-Inrush 7 CURRENT RATING (AMPERES) CODE 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 AMPERES 0.100 0.150 0.200 0.250 0.300 0.350 0.400 0.450 0.500 0.550 0.600 0.650 0.700 0.750 0.800 285 290 295 410 512 415 517 420 522 527 430 435 440 445 450 0.850 0.900 0.950 1.000 1.250 1.500 1.750 2.000 2.250 2.750 3.000 3.500 4.000 4.500 5.000 455 460 465 470 475 480 485 490 495 610 710 611 711 612 712 8 TERMINAL 5 1 6 Push-On 0.250 Tab (Q.C.) 9 2 Screw 8-32 with upturned lugs 3 7 Screw 8-32 (Bus Type) B 4 Screw 10-32 with upturned lugs F 7 5 Screw 10-32 (Bus Type) 6 Screw 8-32 with upturned lugs G & 30 bend H 7 Screw 8-32 (Bus Type) M7 & 30 bend P8 8 Screw 10-32 with upturned lugs Q9 & 30 bend 5.500 6.000 6.500 7.000 7.500 8.000 8.500 9.000 9.500 10.000 10.500 11.000 11.500 12.000 12.500 7 Current Rating 1 B 1 8 Terminal 9 Actuator Color 9 ACTUATOR COLOR & LEGEND Actuator Color ON-OFF White B Black D Red G Green J Blue L Yellow N Gray Q Orange S Black (short handle) 10 U 1 SERIES A 5 AUXILIARY/ALARM SWITCH 2 7 0 without Aux Switch 1 S.P.D.T., 0.093 Q.C. Term. 8 2 S.P.D.T., 0.110 Q.C. Term. 9 450 613 614 615 616 617 618 620 622 624 625 630 635 3 640 3 645 3 650 3 13.000 14.000 15.000 16.000 17.000 18.000 20.000 22.000 24.000 25.000 30.000 35.000 40.000 45.000 50.000 Screw 10-32 (Bus Type) & 30 bend Screw M5 with upturned lugs Screw M5 with upturned lugs & 30 bend Screw M5 (Bus Type) & 30 bend Screw M5 (Bus Type) M6 Threaded Stud Printed Circuit Board Terminals Push-In Stud M T 10 Mounting/ Barriers 11 Max. Appl. Rating Dual 1 2 3 4 5 6 7 8 9 Legend Color Black White White White White Black Black Black White 10 MOUNTING / BARRIERS MOUNTING STYLE Threaded Insert, 2 per pole 1 6-32 x 0.195 inches A 6-32 x 0.195 inches 2 ISO M3 x 5mm B ISO M3 x 5mm (multipole only) Front panel Snap-In, 0.75" wide bezel 5 without Handleguard 6 without Handleguard (multipole only) Front panel Snap-In, 0.96" wide bezel 7 without Handleguard, 1-pole 0.96" wide; multipole units have .105" bezel overhang on all sides 8 without Handleguard, 1-pole 0.96" wide; (multipole only) .105" bezel overhang on all sides 12 Agency Approval BARRIERS no yes no yes no yes no yes 11 MAXIMUM APPLICATION RATING M 80 DC 12 AGENCY APPROVAL T UL489A Listed K UL489A Listed, VDE Certified J UL489A Listed, TUV Certified Notes: 1 Actuator Code: A: Handle tie pin spacer(s) and retainers provided un-assembled with multi-pole units. S: Handle moves to mid-position only upon electrical trip of the breaker. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. 2 On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 3 VDE Certified to 30 amps. UL489A Listed to 50 amps. 4 VDE Certification available with single pole breakers only. UL489A Listing available with one and two pole breakers. 5 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9 G, H, M and Q. 6 Terminal Code 1 (Push-On) available up to 25 amps with VDE Certification and 30 amps with UL489A Listing, but is not recommended over 20 amps. 7 Terminal Codes 3, 5 and H (Bus Type) with VDE, are supplied with Lock Washers, and Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only VDE Certified when the washers are used. 8 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps with VDE Certification and 50 amps with UL489A Listing. 9 Terminal Code Q not available with VDE certification. 10 Single pole only. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com 8 | A-Series Circuit Breaker - Handle WORLD - Ordering Scheme A A 3 1 Series 2 Actuator B 0 4 Circuit 3 Poles 14 5 Aux/Alarm Switch 6 Frequency & Delay 2 ACTUATOR 1 A Handle, one per pole B Handle, one per multipole unit S Mid-Trip Handle, one per pole T Mid-Trip Handle, one per pole & Alarm Switch 3 4 5 6 Three Four 4 CIRCUIT A 2 Switch Only (No Coil) D3 B Series Trip (Current) E3 C Series Trip (Voltage) H 3,4 Five Six Shunt Trip (Current) Shunt Trip (Voltage) Dual Coil with Shunt Trip Voltage Coil 5 AUXILIARY / ALARM SWITCH 5 0 without Aux Switch 2 S.P.D.T., 0.110 Q.C. Term. 4 S.P.D.T., 0.110 Q.C. Term. (Gold Contacts) 6 FREQUENCY & DELAY 03 DC 50/60Hz, Switch Only 10 DC Instantaneous 11 DC Ultra Short 12 DC Short 14 DC Medium 16 DC Long 20 50/60Hz Instantaneous 21 50/60Hz Ultra Short 22 50/60Hz Short 24 50/60Hz Medium 26 50/60Hz Long 30 31 32 34 36 42 7 44 7 46 7 52 7 54 7 56 7 DC, 50/60Hz Instantaneous DC, 50/60Hz Ultra Short DC, 50/60Hz Short DC, 50/60Hz Medium DC, 50/60Hz Long 50/60Hz Short, Hi-Inrush 50/60Hz Medium, Hi-Inrush 50/60Hz Long, Hi-Inrush DC, Short,Hi-Inrush DC, Medium, Hi-Inrush DC, Long, Hi-Inrush 7 CURRENT RATING (AMPERES) CODE AMPERES 210 0.100 285 0.850 455 5.500 215 0.150 290 0.900 460 6.000 220 0.200 295 0.950 465 6.500 225 0.250 410 1.000 470 7.000 230 0.300 512 1.250 475 7.500 235 0.350 415 1.500 480 8.000 240 0.400 517 1.750 485 8.500 245 0.450 420 2.000 490 9.000 250 0.500 522 2.250 495 9.500 255 0.550 527 2.750 610 10.000 260 0.600 430 3.000 710 10.500 265 0.650 435 3.500 611 11.000 270 0.700 440 4.000 711 11.500 275 0.750 445 4.500 612 12.000 280 0.800 450 5.000 712 12.500 OR VOLTAGE COIL (NORMAL RATED VOLTAGE) 6 613 614 615 616 617 618 620 622 624 625 630 635 8 640 8 645 8 650 8 13.000 14.000 15.000 16.000 17.000 18.000 20.000 22.000 24.000 25.000 30.000 35.000 40.000 45.000 50.000 A06 A12 A18 A24 J65 K20 L40 65 AC 120 AC 240 AC CODE AMPERES 6 DC 12 DC 18 DC 24 DC A32 A48 A65 J06 32 DC 48 DC 65 DC 6 AC J12 J18 J24 J48 12 AC 18 AC 24 AC 48 AC 7 Current Rating 1 A 1 8 Terminal 9 Actuator Color 8 TERMINAL 9 1 10 Push-On 0.250 Tab (Q.C.) B 2 Screw 8-32 with upturned lugs C 3 11 Screw 8-32 (Bus Type) E 11 4 Screw 10-32 with upturned lugs F 5 11 Screw 10-32 (Bus Type) 6 Screw 8-32 with upturned lugs G & 30 bend H 11 7 Screw 8-32 (Bus Type) R & 30 bend 8 Screw 10-32 with upturned lugs T 11 & 30 bend 9 Screw 10-32 (Bus Type) & 30 bend 1 SERIES A 3 POLES 1 One 2 Two 450 9 ACTUATOR COLOR & LEGEND Actuator Color I-O White A Black C Red F Green H Blue K Yellow M Gray P Orange R 15 Black (short handle) T 10 Mounting/ Barriers P 11 Agency Approval Screw M5 with upturned lugs Screw M4 with upturned lugs Screw M4 (Bus Type) Screw M5 with upturned lugs & 30 bend Screw M5 (Bus Type) & 30 bend Screw M5 (Bus Type) Screw M4 with upturned lugs & 30 bend Screw M4 (Bus Type) & 30 bend Dual 1 2 3 4 5 6 7 8 9 Legend Color Black White White White White Black Black Black White 10 MOUNTING / BARRIERS MOUNTING STYLE Threaded Insert, 2 per pole 1 6-32 x 0.195 inches A 6-32 x 0.195 inches 2 ISO M3 x 5mm B ISO M3 x 5mm (multipole only) Front panel Snap-In, 0.75" wide bezel 5 without Handleguard 6 without Handleguard (multipole only) Front panel Snap-In, 0.96" wide bezel 7 without Handleguard, 1-pole 0.96" wide; multipole units have .105" bezel overhang on all sides 8 without Handleguard, 1-pole 0.96" wide; (multipole only) .105" bezel overhang on all sides BARRIERS no yes no yes no yes no yes 11 AGENCY APPROVAL P TUV Certified, UL Recognized & CSA Accepted Q UL Recognized STD 1077, UL Recognized 1500 (ignition protected), & CSA Accepted Notes: 1 Actuator Code: A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units. S: Handle moves to mid-position only upon electrical trip of the breaker. Available with circuit codes B, C, D, E, and H. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. Available with circuit codes B & C. 2 Switch Only circuits, rated up to 50 amps and 6 poles, and only available when tied to a protected pole (Circuit Code B, C, D or H.), For .01 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. 3 Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum. 4 Consult factory for available Dual Coil options, as special catalog number is required. With Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils require 30VA minimum power to trip and are rated for intermittent duty only. 5 On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 6 Separate pole type voltage coils not rated for continuous duty. Available only with delay codes 10, 20 & 30. 7 Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized, CSA Accepted & TUV Certified to 50 amps. 8 Available up to two poles with AC or DC delays. 9 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G and H. 10 Terminal Code 1: TUV Certification up to 30 amps, but not recommended over 20 amps. 11 Terminal Codes 3, 5 , 7, 9, E, G and H (Bus Type) are supplied with Lock Washers. These breakers are only TUV Certified when the washers are used. 12 Single pole only. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com A-Series Circuit Breaker - Rocker UL489A - Ordering Scheme | 9 A F 1 1 Series 2 Actuator B 0 4 Circuit 3 Poles 5 Aux/Alarm Switch 14 6 Frequency & Delay 1 SERIES A 2 ACTUATOR 1 Two Color Visi-Rocker C Indicate ON, vertical legend D Indicate ON, horizontal legend F Indicate OFF, vertical legend G Indicate OFF, horizontal legend Single color J Vertical legend K Horizontal legend Push-To-Reset, Visi-Rocker N Indicate OFF, vertical legend O Indicate OFF, horizontal legend Push-To-Reset , Single color R Vertical legend U Horizontal legend 450 7 Current Rating 1 3 1 8 Terminal 9 Actuator Color 10 Mounting/ Barriers 8 TERMINAL 5 1 6 Push-On 0.250 Tab (Q.C.) 9 2 Screw 8-32 with upturned lugs 7 3 Screw 8-32 (Bus Type) B 4 Screw 10-32 with upturned lugs F 7 5 Screw 10-32 (Bus Type) 6 Screw 8-32 with upturned lugs G & 30 bend H 7 Screw 8-32 (Bus Type) M7 & 30 bend P8 8 Screw 10-32 with upturned lugs Q9 & 30 bend M T 11 Max. Appl. Rating 12 Agency Approval Screw 10-32 (Bus Type) & 30 bend Screw M5 with upturned lugs Screw M5 with upturned lugs & 30 bend Screw M5 (Bus Type) & 30 bend Screw M5 (Bus Type) M6 Threaded Stud Printed Circuit Board Terminals Push-In Stud 9 ACTUATOR COLOR & LEGEND Actuator or Marking: Marking Color Visi-Color 10 ON-OFF Dual 10 Single Color Visi-Rocker White B 1 Black White Black D 2 White n/a Red G 3 White Red Green J 4 White Green Blue L 5 White Blue Yellow N 6 Black Yellow Gray Q 7 Black Gray Orange S 8 Black Orange 3 POLES 2 1 One 2 Two 3 Three 4 CIRCUIT B Series Trip (Current) 5 AUXILIARY / ALARM SWITCH 2 7 0 without Aux Switch 1 S.P.D.T., 0.093 Q.C. Term. 8 2 S.P.D.T., 0.110 Q.C. Term. 9 6 FREQUENCY & DELAY 11 DC Ultra Short 12 DC Short 14 DC Medium 16 DC Long 52 54 56 S.P.S.T., 0.110 Q.C. Term. (Gold Contacts) S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. DC, Short,Hi-Inrush DC, Medium, Hi-Inrush DC, Long, Hi-Inrush 7 CURRENT RATING (AMPERES) CODE 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 AMPERES 0.100 0.150 0.200 0.250 0.300 0.350 0.400 0.450 0.500 0.550 0.600 0.650 0.700 0.750 0.800 285 290 295 410 512 415 517 420 522 527 430 435 440 445 450 0.850 0.900 0.950 1.000 1.250 1.500 1.750 2.000 2.250 2.750 3.000 3.500 4.000 4.500 5.000 455 460 465 470 475 480 485 490 495 610 710 611 711 612 712 5.500 6.000 6.500 7.000 7.500 8.000 8.500 9.000 9.500 10.000 10.500 11.000 11.500 12.000 12.500 613 614 615 616 617 618 620 622 624 625 630 635 4 640 4 645 4 650 4 13.000 14.000 15.000 16.000 17.000 18.000 20.000 22.000 24.000 25.000 30.000 35.000 40.000 45.000 50.000 10 MOUNTING / BARRIERS 11 STANDARD ROCKER BEZEL BARRIERS Threaded Insert, 2 per pole 1 6-32 x 0.195 inches no A 6-32 X 0.195 inches (multi-pole units only) yes 2 ISO M3 x 5mm no B ISO M3 x 5mm (multi-pole units only) yes ROCKERGUARD & PUSH-TO-RESET BEZEL Threaded Insert, 2 per pole 3 6-32 x 0.195 inches no C 6-32 x 0.195 inches (multi-pole units only) yes 4 ISO M3 x 5mm no D ISO M3 x 5mm (multi-pole units only) yes FRONT PANEL SNAP-IN BRACKET, 0.744" [18.90mm] wide bezel 8 without Rockerguard (single pole units only) no H with Rockerguard (single pole units only) no FRONT PANEL SNAP-IN BRACKET, 0.96" [24.48mm] wide bezel 9 without Rockerguard (single pole units only) no J with Rockerguard (single pole units only) no 11 MAXIMUM APPLICATION RATING M 80 DC 12 AGENCY APPROVAL T UL489A Listed K UL489A Listed, VDE Certified J UL489A Listed, TUV Certified Notes: 1 Push-To-Reset actuators have OFF portion of rocker shrouded. 2 Multi-pole breakers have all breakers identical except when specifying Auxiliary switch and/or mixed poles, and have one rocker per breaker. 3 Auxiliary Switch breakers with Series Trip circuits: 30A, are supplied with standard half shells. 30-50A are supplied with extended boat (B-Style) half shells. 4 VDE Certification available with single pole breakers only. UL489A Listing available with one and two pole breakers. 5 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G, H, M and Q. 6 Terminal Code 1 (Push-On) available up to 25 amps with TUV or VDE Certification and 30 amps with UL489A Listing, but is not recommended over 20 amps. 7 Terminal Codes 3, 5 and H (Bus Type) with TUV or VDE, are supplied with Lock Washers, and Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only TUV or VDE Certified when the washers are used. 8 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps with VDE Certification and 50 amps with UL489A Listing. 9 Terminal Code Q not available with VDE certification. 10 Color shown is Visi and Legend with remainder of rocker black. Dual = ON-OFF/I-O legend. 11 Legend on Push-to-reset bezel/shroud is white with single color actuator codes R & U. Legend on Push-To-Reset bezel/shroud matches Visi-Color of rocker with actuator codes N & O. Rockerguard available with actuator codes C through K Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com 10 | A-Series Circuit Breaker - Handle - Circuit & Terminal Diagrams Circuit & Terminal Diagrams: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance .020 [.51] unless otherwise specified. 3 Alarm Switch available with .110 x .020 Q.C. & Solder Lug Terminals Only. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com A-Series Circuit Breaker - Handle - Circuit & Terminal Diagrams | 11 Circuit & Terminal Diagrams: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance .020 [.51] unless otherwise specified. 3 Alarm Switch available with .110 x .020 QC & solder lug terminals only. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com 12 | A-Series Circuit Breaker - Handle - Dimensional Specifications Dimensional Specifications: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance 0.20 [.51] unless otherwise specified. 3 For agency code P = .150 [3.81]. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com A-Series Circuit Breaker - Handle - Front Panel Snap-In Mounting Style 5 - Dimensional Specifications | 13 Dimensional Specifications: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Recommended panel thickness: .040 [1.02] to .100 [2.54]. 3 Tolerance .020 [.51] unless otherwise specified. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com 14 | A-Series Circuit Breaker - Handle - Front Panel Snap-In Mounting Style 7 - Dimensional Specifications Dimensional Specifications: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Recommended panel thickness: .040 [1.02] to .100 [2.54]. 3 Tolerance .020 [.51] unless otherwise specified. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com A-Series Circuit Breaker - Sealed Toggle UL Recognized - Ordering Scheme | 15 A M 1 1 Series 2 Actuator 3 Poles B 0 4 Circuit 5 Aux/Alarm Switch 10 6 Frequency & Delay 1 SERIES A 2 ACTUATOR 1 M Sealed Toggle, one per unit 3 POLES 1 One 2 Two 3 Three 4 CIRCUIT A 2 Switch Only (No Coil) F3 B Series Trip (Current) G3 C Series Trip (Voltage) H 3,4 D 3 Shunt Trip (Current) E 3 Shunt Trip (Voltage) K 3,4 Relay Trip (Current) Relay Trip (Voltage) Dual Coil with Shunt Trip Voltage Coil Dual Coil with Relay Trip Voltage Coil 5 AUXILIARY / ALARM SWITCH 5 5 0 without Aux Switch 1 S.P.D.T., 0.093 Q.C. Term. 7 2 S.P.D.T., 0.110 Q.C. Term. 4 S.P.D.T., 0.110 Q.C. Term. 8 (Gold Contacts) 9 S.P.S.T., 0.093 Q.C. Term. (Gold Contacts) S.P.S.T., 0.110 Q.C. Term. (Gold Contacts) S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. 6 FREQUENCY & DELAY 03 DC 50/60Hz, Switch Only 10 DC Instantaneous 11 DC Ultra Short 12 DC Short 14 DC Medium 16 DC Long 20 50/60Hz Instantaneous 21 50/60Hz Ultra Short 22 50/60Hz Short 24 50/60Hz Medium 26 50/60Hz Long 30 31 32 34 36 42 7 44 7 46 7 52 7 54 7 56 7 DC, 50/60Hz Instantaneous DC, 50/60Hz Ultra Short DC, 50/60Hz Short DC, 50/60Hz Medium DC, 50/60Hz Long 50/60Hz Short, Hi-Inrush 50/60Hz Medium, Hi-Inrush 50/60Hz Long, Hi-Inrush DC, Short,Hi-Inrush DC, Medium, Hi-Inrush DC, Long, Hi-Inrush 7 CURRENT RATING (AMPERES) CODE 020 025 030 035 040 045 050 055 060 065 070 075 080 085 090 095 210 215 220 225 AMPERES 0.020 0.025 0.030 0.035 0.040 0.045 0.050 0.055 0.060 0.065 0.070 0.075 0.080 0.085 0.090 0.095 0.100 0.150 0.200 0.250 230 235 240 245 250 255 260 265 270 275 280 285 290 295 410 512 415 517 420 522 0.300 0.350 0.400 0.450 0.500 0.550 0.600 0.650 0.700 0.750 0.800 0.850 0.900 0.950 1.000 1.250 1.500 1.750 2.000 2.250 425 527 430 435 440 445 450 455 460 465 470 475 480 485 490 495 610 710 611 711 2.500 2.750 3.000 3.500 4.000 4.500 5.000 5.500 6.000 6.500 7.000 7.500 8.000 8.500 9.000 9.500 10.000 10.500 11.000 11.500 612 712 613 614 615 616 617 618 620 622 624 625 630 635 8 640 8 645 8 650 8 12.000 12.500 13.000 14.000 15.000 16.000 17.000 18.000 20.000 22.000 24.000 25.000 30.000 35.000 40.000 45.000 50.000 A32 A48 A65 J06 32 DC 48 DC 65 DC 6 AC J12 J18 J24 J48 12 AC 18 AC 24 AC 48 AC J65 K20 L40 65 AC 120 AC 240 AC 450 7 Current Rating 1 0 1 8 Terminal 9 Actuator Color 8 TERMINAL 9 1 10 Push-On 0.250 Tab (Q.C.) E 2 Screw 8-32 with upturned lugs F 3 Screw 8-32 (Bus Type) 4 Screw 10-32 with upturned lugs G 5 Screw 10-32 (Bus Type) H 6 Screw 8-32 with upturned lugs L 12 & 30 bend M 7 Screw 8-32 (Bus Type) Q & 30 bend R 8 Screw 10-32 with upturned lugs & 30 bend T 9 Screw 10-32 (Bus Type) & 30 bend P 12 B Screw M5 with upturned lugs S C Screw M4 with upturned lugs 10 Mounting/ Barriers Screw M4 (Bus Type) Screw M5 with upturned lugs & 30 bend Screw M5 (Bus Type) & 30 bend Screw M5 (Bus Type) 0.250 Q.C./ Solder Lug M6 Threaded Stud Push-In Stud Screw M4 with upturned lugs & 30 bend Screw M4 (Bus Type) & 30 bend Printed Circuit Board Terminals Push-On 0.110 Tab (Q.C.) 9 LEGEND PLATE 0 No legend plate 10 MOUNTING / BARRIERS MOUNTING STYLEBARRIERS 1 Standard Hex Nut no A Standard Hex Nut (multipole only) yes 11 AGENCY APPROVAL C UL Recognized & CSA Accepted I UL Recognized STD 1077, UL Recognized 1500 (ignition protected), & CSA Accepted Notes: 1 Actuator Code M: Handle location as viewed from front of panel: 2 pole - right pole 3 pole - center pole 2 Switch Only circuits, rated up to 50 amps and 3 poles. Only available when tied to a protected pole. For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. 3 Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum. 4 Consult factory for available Dual Coil options, as special catalog number is required. With Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils require 30VA minimum power to trip and are rated for intermittent duty only. 5 Auxiliary Switch available on Series Trip & Switch Only circuits, limited to 30 amps. On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 6 Voltage coils not rated for continuous duty. Available only with delay codes 10 and 20. 7 Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized, CSA Accepted & TUV Certified to 50 amps. 8 UL Recognition and CSA Certification available on one and two pole breakers. 9 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, B, F, G, H, M and Q. 10 Terminal Code 1: UL Recognition and CSA Certification up to 30 amps, but not recommended over 20 amps. 11 Terminal Code L : available up to 30A. 12 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 50 amps, with Circuit Codes A, B and C. Two pole breakers with Terminal Code P (Printed Circuit Board) are available up to 40 amps with Circuit Codes A, B and C. OR VOLTAGE COIL (NORMAL RATED VOLTAGE) 6 CODE A06 A12 A18 A24 AMPERES 6 DC 12 DC 18 DC 24 DC C 11 Agency Approval Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com 16 | A-Series Circuit Breaker - Sealed Toggle - Dimensional Specifications Dimensional Specifications: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance .020 [.51] unless otherwise specified. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com A-Series Circuit Breaker - Rocker UL Recognized - Ordering Scheme | 17 A F 1 1 Series 2 Actuator B 0 4 Circuit 3 Poles 24 5 Aux/Alarm Switch 6 Frequency & Delay 2 3 1 8 Terminal 9 Actuator Color 10 Mounting/ Barriers D 11 Agency Approval 7 CURRENT RATING (AMPERES) 1 SERIES A CODE 2 ACTUATOR 1 Two Color Visi-Rocker C Indicate ON, vertical legend D Indicate ON, horizontal legend F Indicate OFF, vertical legend G Indicate OFF, horizontal legend H Indicate OFF, no legend Push-To-Reset, Visi-Rocker N Indicate OFF, vertical legend O Indicate OFF, horizontal legend P Indicate OFF, no legend Single color J Vertical legend K Horizontal legend L No legend Push-To-Reset , Single color R Vertical legend U Horizontal legend V No legend 3 POLES 1 One 630 7 Current Rating 2 3 Three 4 CIRCUIT F4 A 3 Switch Only (No Coil) G4 B Series Trip (Current) H 4,5 C Series Trip (Voltage) 4 D Shunt Trip (Current) K 4,5 E 4 Shunt Trip (Voltage) Relay Trip (Current) Relay Trip (Voltage) Dual Coil with Shunt Trip Voltage Coil Dual Coil with Relay Trip Voltage Coil 5 AUXILIARY / ALARM SWITCH 6,7 5 0 without Aux Switch 1 S.P.D.T., 0.093 Q.C. Term. 7 2 S.P.D.T., 0.110 Q.C. Term. 4 S.P.D.T., 0.110 Q.C. Term. 8 (Gold Contacts) 9 S.P.S.T., 0.093 Q.C. Term. (Gold Contacts) S.P.S.T., 0.110 Q.C. Term. (Gold Contacts) S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. 6 FREQUENCY & DELAY 03 DC 50/60Hz, Switch Only 10 DC Instantaneous 11 DC Ultra Short 12 DC Short 14 DC Medium 16 DC Long 20 50/60Hz Instantaneous 21 50/60Hz Ultra Short 22 50/60Hz Short 24 50/60Hz Medium 26 50/60Hz Long 611 711 612 712 613 614 615 616 617 618 620 622 624 625 630 635 8 640 8 645 8 650 8 11.000 11.500 12.000 12.500 13.000 14.000 15.000 16.000 17.000 18.000 20.000 22.000 24.000 25.000 30.000 35.000 40.000 45.000 50.000 A06 A12 A18 A24 J65 K20 L40 65 AC 120 AC 240 AC CODE Two 30 31 32 34 36 42 9 44 9 46 9 52 9 54 9 56 9 DC, 50/60Hz Instantaneous DC, 50/60Hz Ultra Short DC, 50/60Hz Short DC, 50/60Hz Medium DC, 50/60Hz Long 50/60Hz Short, Hi-Inrush 50/60Hz Medium, Hi-Inrush 50/60Hz Long, Hi-Inrush DC, Short,Hi-Inrush DC, Medium, Hi-Inrush DC, Long, Hi-Inrush Notes: 1 Push-To-Reset actuators have OFF portion of rocker shrouded. 2 Multi-pole breakers have all breakers identical except when specifying Auxiliary switch and/or mixed poles, and have one rocker per breaker. 3 Switch Only circuits, rated up to 50 amps & 3 poles, are available only when tied to a protected pole (Circuit Code B, C, D or H.), For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. 4 Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum. 5 Consult factory for Dual Coil options, as special catalog number is required. With Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils require 30VA minimum power to trip and are rated for intermittent duty only. 6 Auxiliary Switch breakers with Series Trip & Switch Only circuits: 30A, are supplied with standard half shells. 30-50A are supplied with extended boat (B-Style) half shells. 7 On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 8 Separate pole type voltage coils not rated for continuous duty. Available only with delay codes 10 & 20. 9 Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized, CSA Accepted & TUV Certified to 50 amps. 10 Series Trip current ratings: VDE Certification available with single pole breakers with DC Delay only. UL Recognition & CSA Accepted available in one and two pole breakers. 11 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G, H, M and Q. 12 Terminal Code 1: VDE Certification up to 25 amps and UL Recognition and CSA Accepted up to 30 amps, but not recommended over 20 amps. 13 Terminal Codes 3, 5 E & H (Bus Type) with VDE, are supplied with Lock Washers; Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only VDE Certified when the washers are used. 14 VDE Cert. available up to 12 amps. UL Rec. & CSA Accepted available up to 30 amps. 15 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps with VDE Certification and 50 amps with UL Recognition and CSA Accepted, with Circuit Codes A, B & C. Two pole breakers with Terminal Code P (Printed Circuit Board) are available up to 40 amps with UL Recognition and CSA Certification with Circuit Codes A, B and C. 16 Terminal Code Q not available with VDE. 17 Terminal Code S used on voltage coil circuit constructions only. 18 Color shown is visi and legend with remainder of rocker black. 19 Dual = ON-OFF/I-O legend with actuator. None = no legend on actuator 20 Legend on Push-to-reset bezel/shroud is white with single color actuator codes R, & U. Legend on Push-to-reset bezel/shroud matches Visi-color of rocker with actuator codes N & O. Rockerguard available with actuator codes C through L. AMPERES 020 0.020 225 0.250 420 2.000 025 0.025 230 0.300 522 2.250 030 0.030 235 0.350 527 2.750 035 0.035 240 0.400 430 3.000 040 0.040 245 0.450 435 3.500 045 0.045 250 0.500 440 4.000 050 0.050 255 0.550 445 4.500 055 0.055 260 0.600 450 5.000 060 0.060 265 0.650 455 5.500 065 0.065 270 0.700 460 6.000 070 0.070 275 0.750 465 6.500 075 0.075 280 0.800 470 7.000 080 0.080 285 0.850 475 7.500 085 0.085 290 0.900 480 8.000 090 0.090 295 0.950 485 8.500 095 0.095 410 1.000 490 9.000 210 0.100 512 1.250 495 9.500 215 0.150 415 1.500 610 10.000 220 0.200 517 1.750 710 10.500 OR VOLTAGE COIL (NORMAL RATED VOLTAGE) 8 AMPERES 6 DC 12 DC 18 DC 24 DC A32 A48 A65 J06 32 DC 48 DC 65 DC 6 AC J12 J18 J24 J48 12 AC 18 AC 24 AC 48 AC 8 TERMINAL 11 1 12 Push-On 0.250 Tab (Q.C.) E 13 Screw M4 (Bus Type) 2 Screw 8-32 with upturned lugs F Screw M5 with upturned lugs 13 3 Screw 8-32 (Bus Type) & 30 bend 4 Screw 10-32 with upturned lugs G Screw M5 (Bus Type) & 30 bend H 13 Screw M5 (Bus Type) 5 13 Screw 10-32 (Bus Type) 6 Screw 8-32 with upturned lugs L 14 0.250 Q.C./ Solder Lug & 30 bend M 13 M6 Threaded Stud 7 Screw 8-32 (Bus Type) P 15 Printed Circuit Board Terminals & 30 bend Q 16 Push-In Stud 8 Screw 10-32 with upturned lugs R Screw M4 with upturned lugs & 30 bend & 30 bend 17 9 Screw 10-32 (Bus Type) S Push-On 0.110 Tab (Q.C.) & 30 bend & 30 bend B Screw M5 with upturned lugs T Screw M4 (Bus Type) C Screw M4 with upturned lugs & 30 bend 9 ACTUATOR COLOR & LEGEND Actuator or Marking: Marking Color Visi-Color 12 I-O ON-OFF Dual 12 Single Color Visi-Rocker White A B 1 Black White Black C D 2 White n/a Red F G 3 White Red Green H J 4 White Green Blue K L 5 White Blue Yellow M N 6 Black Yellow Gray P Q 7 Black Gray Orange R S 8 Black Orange 10 MOUNTING / BARRIERS 20 STANDARD ROCKER BEZEL BARRIERS Threaded Insert, 2 per pole 1 6-32 x 0.195 inches no A 6-32 X 0.195 inches (multi-pole units only) yes 2 ISO M3 x 5mm no B ISO M3 x 5mm (multi-pole units only) yes ROCKERGUARD & PUSH-TO-RESET BEZEL Threaded Insert, 2 per pole 3 6-32 x 0.195 inches no C 6-32 x 0.195 inches (multi-pole units only) yes 4 ISO M3 x 5mm no D ISO M3 x 5mm (multi-pole units only) yes FRONT PANEL SNAP-IN BRACKET, 0.744" [18.90mm] wide bezel 8 without Rockerguard (single pole units only) no H with Rockerguard (single pole units only) no FRONT PANEL SNAP-IN BRACKET, 0.96" [24.48mm] wide bezel 9 without Rockerguard (single pole units only) no J with Rockerguard (single pole units only) no 11 AGENCY APPROVAL C UL Recognized & CSA Accepted D VDE Certified, UL Recognized & CSA Accepted E TUV Certified, UL Recognized & CSA Accepted I UL Recognized STD 1077, UL Recognized 1500 (ignition protected), & CSA Accepted Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com 18 | A-Series Circuit Breaker - Flat Rocker UL Recognized - Ordering Scheme A 1 1 1 Series 2 Actuator B 0 4 Circuit 3 Poles 24 5 Aux/Alarm Switch 6 Frequency & Delay 2 ACTUATOR 1 Two Color Visi-Rocker 1 Indicate OFF, vertical legend 2 Indicate OFF, horizontal legend Single color 3 Vertical legend 4 Horizontal legend Push-To-Reset, Visi-Rocker 5 Indicate OFF, vertical legend 6 Indicate OFF, horizontal legend Push-To-Reset , Single color 7 Vertical legend 8 Horizontal legend 2 3 Two Three 4 CIRCUIT F4 A 3 Switch Only (No Coil) G4 B Series Trip (Current) H 4,5 C Series Trip (Voltage) 4 D Shunt Trip (Current) K 4,5 E 4 Shunt Trip (Voltage) Relay Trip (Current) Relay Trip (Voltage) Dual Coil with Shunt Trip Voltage Coil Dual Coil with Relay Trip Voltage Coil 5 AUXILIARY / ALARM SWITCH 6,7 5 0 without Aux Switch 1 S.P.D.T., 0.093 Q.C. Term. 7 2 S.P.D.T., 0.110 Q.C. Term. 4 S.P.D.T., 0.110 Q.C. Term. 8 (Gold Contacts) 9 S.P.S.T., 0.093 Q.C. Term. (Gold Contacts) S.P.S.T., 0.110 Q.C. Term. (Gold Contacts) S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. 6 FREQUENCY & DELAY 03 DC 50/60Hz, Switch Only 10 6 DC Instantaneous 11 DC Ultra Short 12 DC Short 14 DC Medium 16 DC Long 20 6 50/60Hz Instantaneous 21 50/60Hz Ultra Short 22 50/60Hz Short 24 50/60Hz Medium 26 50/60Hz Long 30 31 32 34 36 42 9 44 9 46 9 52 9 54 9 56 DC, 50/60Hz Instantaneous DC, 50/60Hz Ultra Short DC, 50/60Hz Short DC, 50/60Hz Medium DC, 50/60Hz Long 50/60Hz Short, Hi-Inrush 50/60Hz Medium, Hi-Inrush 50/60Hz Long, Hi-Inrush DC, Short,Hi-Inrush DC, Medium, Hi-Inrush DC, Long, Hi-Inrush 7 CURRENT RATING (AMPERES) CODE AMPERES 020 0.020 225 0.250 420 2.000 025 0.025 230 0.300 522 2.250 030 0.030 235 0.350 527 2.750 035 0.035 240 0.400 430 3.000 040 0.040 245 0.450 435 3.500 045 0.045 250 0.500 440 4.000 050 0.050 255 0.550 445 4.500 055 0.055 260 0.600 450 5.000 060 0.060 265 0.650 455 5.500 065 0.065 270 0.700 460 6.000 070 0.070 275 0.750 465 6.500 075 0.075 280 0.800 470 7.000 080 0.080 285 0.850 475 7.500 085 0.085 290 0.900 480 8.000 090 0.090 295 0.950 485 8.500 095 0.095 410 1.000 490 9.000 210 0.100 512 1.250 495 9.500 215 0.150 415 1.500 610 10.000 220 0.200 517 1.750 710 10.500 OR VOLTAGE COIL (NORMAL RATED VOLTAGE) 8 611 711 612 712 613 614 615 616 617 618 620 622 624 625 630 635 8 640 8 645 8 650 8 11.000 11.500 12.000 12.500 13.000 14.000 15.000 16.000 17.000 18.000 20.000 22.000 24.000 25.000 30.000 35.000 40.000 45.000 50.000 A06 A12 A18 A24 J65 K20 L40 65 AC 120 AC 240 AC CODE AMPERES 6 DC 12 DC 18 DC 24 DC A32 A48 A65 J06 32 DC 48 DC 65 DC 6 AC 2 3 1 8 Terminal 9 Actuator Color 10 Mounting/ Barriers E 11 Agency Approval 8 TERMINAL 11 1 12 Push-On 0.250 Tab (Q.C.) E 13 Screw M4 (Bus Type) 2 Screw 8-32 with upturned lugs F Screw M5 with upturned lugs 3 13 Screw 8-32 (Bus Type) & 30 bend 4 Screw 10-32 with upturned lugs G Screw M5 (Bus Type) & 30 bend H 13 Screw M5 (Bus Type) 5 13 Screw 10-32 (Bus Type) 6 Screw 8-32 with upturned lugs L 14 0.250 Q.C./ Solder Lug & 30 bend M 13 M6 Threaded Stud 7 Screw 8-32 (Bus Type) P 15 Printed Circuit Board Terminals & 30 bend Q Push-In Stud 8 Screw 10-32 with upturned lugs R Screw M4 with upturned lugs & 30 bend & 30 bend 9 Screw 10-32 (Bus Type) S 16 Push-On 0.110 Tab (Q.C.) & 30 bend & 30 bend B Screw M5 with upturned lugs T Screw M4 (Bus Type) C Screw M4 with upturned lugs & 30 bend 1 SERIES A 3 POLES 2 1 One 630 7 Current Rating J12 J18 J24 J48 12 AC 18 AC 24 AC 48 AC 9 ACTUATOR COLOR & LEGEND Actuator or Marking: Marking Color Visi-Color 17 ON-OFF Dual 17 Single Color Visi-Rocker White B 1 Black White Black D 2 White n/a Red G 3 White Red Green J 4 White Green Blue L 5 White Blue Yellow N 6 Black Yellow Gray Q 7 Black Gray Orange S 8 Black Orange 10 MOUNTING / BARRIERS 18 STANDARD ROCKER BEZEL BARRIERS Threaded Insert, 2 per pole FLAT ROCKER ACTUATOR 1 6-32 x 0.195 inches no A 6-32 X 0.195 inches (multi-pole units only) yes 2 ISO M3 x 5mm no B ISO M3 x 5mm (multi-pole units only) yes 19 RECESSED OFF SIDE ROCKER ACTUATOR 5 6-32 x 0.195 inches no E 6-32 x 0.195 inches (multi-pole units only) yes 6 ISO M3 x 5mm no F ISO M3 x 5mm (multi-pole units only) yes PUSH-TO-RESET BEZEL,Threaded Insert, 2 per pole 3 6-32 x 0.195 inches no C 6-32 x 0.195 inches (multi-pole units only) yes 4 ISO M3 x 5mm no D ISO M3 x 5mm (multi-pole units only) yes 11 AGENCY APPROVAL C UL Recognized & CSA Accepted E TUV Certified, UL Recognized & CSA Accepted I UL Recognized STD 1077, UL Recognized 1500 (ignition protected), & CSA Accepted Notes: 1 Push-To-Reset actuators have OFF portion of rocker shrouded. 2 Multi-pole breakers have all breakers identical except when specifying Auxiliary switch and/or mixed poles, and have one rocker per breaker. 3 Switch Only circuits, rated up to 50 amps & 3 poles. Only available when tied to a protected pole. For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. 4 Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum. 5 Consult factory for Dual Coil options, as special catalog number is required. With Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils require 30VA minimum power to trip and are rated for intermittent duty only. 6 Auxiliary Switch breakers with Series Trip & Switch Only circuits: 30A, are supplied with standard half shells. 30-50A are supplied with extended boat (B-Style) half shells. 7 On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 8 Separate pole type voltage coils not rated for continuous duty. Available only with delay codes 10 & 20. 9 Available with Circuit Codes B & D only. UL Recognized, CSA Accepted & TUV Certified to 50 amps. 10 UL Recognition, CSA Acceptance & TUV Certification available in one and two pole breakers. 11 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G, H, M and Q. 12 Terminal Code 1: Available up to 30 amps, but not recommended over 20 amps. 13 Terminal Codes 3, 5 E & H (Bus Type) with TUV, are supplied with Lock Washers; Terminal Code M (M6 Threaded Stud) with TUV is supplied with Lock and Flat Washers. These breakers are only TUV Certified when the washers are used. 14 TUV Cert. available up to 12 amps. UL Rec. & CSA Accepted available up to 30 amps. 15 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 50 amps with UL Recognition, CSA Accepted & TUV Certification, with Circuit Codes A, B and C. Two pole breakers with Terminal Code P (Printed Circuit Board) are available up to 40 amps with UL Recognition and CSA Accepted with Circuit Codes A, B and C. 16 Terminal Code S used on voltage coil circuit constructions only. 17 Color shown is visi and legend with remainder of rocker black, Dual = ON-OFF/I-O legend. 18 Legend on Push-to-reset bezel/shroud is white with single color actuator codes 7 & 8. Legend on Push-To-Reset bezel/shroud matches Visi-Color of rocker with actuator codes 5 & 6. 19 Recessed "off-side" available with actuator codes 1, 2, 3 & 4. Legends on rocker are available in ink stamping only. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com A-Series Circuit Breaker - Flat Rocker UL 489A - Ordering Scheme | 19 A 1 1 1 Series 2 Actuator B 0 4 Circuit 3 Poles 14 5 Aux/Alarm Switch 6 Frequency & Delay 2 ACTUATOR 1 Two Color Visi-Rocker 1 Indicate OFF, vertical legend 2 Indicate OFF, horizontal legend Single color 3 Vertical legend 4 Horizontal legend Push-To-Reset, Visi-Rocker 5 Indicate OFF, vertical legend 6 Indicate OFF, horizontal legend Push-To-Reset , Single color 7 Vertical legend 8 Horizontal legend 2 3 Two Three 4 CIRCUIT B Series Trip (Current) 5 AUXILIARY / ALARM SWITCH 3 7 0 without Aux Switch 1 S.P.D.T., 0.093 Q.C. Term. 8 2 S.P.D.T., 0.110 Q.C. Term. 9 6 FREQUENCY & DELAY 11 DC Ultra Short 12 DC Short 14 DC Medium 16 DC Long 52 54 56 S.P.S.T., 0.110 Q.C. Term. (Gold Contacts) S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. DC, Short,Hi-Inrush DC, Medium, Hi-Inrush DC, Long, Hi-Inrush 7 CURRENT RATING (AMPERES) CODE 020 025 030 035 040 045 050 055 060 065 070 075 080 085 090 095 210 215 220 AMPERES 0.020 0.025 0.030 0.035 0.040 0.045 0.050 0.055 0.060 0.065 0.070 0.075 0.080 0.085 0.090 0.095 0.100 0.150 0.200 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 410 512 415 517 0.250 0.300 0.350 0.400 0.450 0.500 0.550 0.600 0.650 0.700 0.750 0.800 0.850 0.900 0.950 1.000 1.250 1.500 1.750 2 3 1 8 Terminal 9 Actuator Color 10 Mounting/ Barriers 8 TERMINAL 5 1 6 Push-On 0.250 Tab (Q.C.) 9 2 Screw 8-32 with upturned lugs 7 3 Screw 8-32 (Bus Type) B 4 Screw 10-32 with upturned lugs F 5 7 Screw 10-32 (Bus Type) 6 Screw 8-32 with upturned lugs G & 30 bend H 7 Screw 8-32 (Bus Type) M7 & 30 bend P8 8 Screw 10-32 with upturned lugs Q9 & 30 bend 1 SERIES A 3 POLES 2 1 One 630 7 Current Rating 420 522 527 430 435 440 445 450 455 460 465 470 475 480 485 490 495 610 710 2.000 2.250 2.750 3.000 3.500 4.000 4.500 5.000 5.500 6.000 6.500 7.000 7.500 8.000 8.500 9.000 9.500 10.000 10.500 611 711 612 712 613 614 615 616 617 618 620 622 624 625 630 635 4 640 4 645 4 650 4 11.000 11.500 12.000 12.500 13.000 14.000 15.000 16.000 17.000 18.000 20.000 22.000 24.000 25.000 30.000 35.000 40.000 45.000 50.000 M T 11 Max. Appl. Rating 12 Agency Approval Screw 10-32 (Bus Type) & 30 bend Screw M5 with upturned lugs Screw M5 with upturned lugs & 30 bend Screw M5 (Bus Type) & 30 bend Screw M5 (Bus Type) M6 Threaded Stud Printed Circuit Board Terminals Push-In Stud 9 ACTUATOR COLOR & LEGEND Actuator or Marking: Marking Color Visi-Color 11 ON-OFF Dual 11 Single Color Visi-Rocker White B 1 Black White Black D 2 White n/a Red G 3 White Red Green J 4 White Green Blue L 5 White Blue Yellow N 6 Black Yellow Gray Q 7 Black Gray Orange S 8 Black Orange 10 MOUNTING / BARRIERS 12 STANDARD ROCKER BEZEL BARRIERS Threaded Insert, 2 per pole FLAT ROCKER ACTUATOR 1 6-32 x 0.195 inches no A 6-32 X 0.195 inches (multi-pole units only) yes 2 ISO M3 x 5mm no B ISO M3 x 5mm (multi-pole units only) yes RECESSED OFF SIDE ROCKER ACTUATOR 5 6-32 x 0.195 inches no E 6-32 x 0.195 inches (multi-pole units only) yes 6 ISO M3 x 5mm no F ISO M3 x 5mm (multi-pole units only) yes PUSH-TO-RESET BEZEL,Threaded Insert, 2 per pole 3 6-32 x 0.195 inches no C 6-32 x 0.195 inches (multi-pole units only) yes 4 ISO M3 x 5mm no D ISO M3 x 5mm (multi-pole units only) yes 11 MAXIMUM APPLICATION RATING M 80 DC 12 AGENCY APPROVAL T UL489A Listed J UL489A Listed, TUV Certified Notes: 1 Push-To-Reset actuators have OFF portion of rocker shrouded. 2 Multi-pole breakers have all breakers identical except when specifying Auxiliary switch and/or mixed poles, and have one rocker per breaker. 3 Auxiliary Switch breakers with Series Trip circuits: 30A, are supplied with standard half shells. 30-50A are supplied with extended boat (B-Style) half shells. 4 VDE Certification available with single pole breakers only. UL489A Listing available with one and two pole breakers. 5 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G, H, M and Q. 6 Terminal Code 1 (Push-On) available up to 25 amps with TUV or VDE Certification and 30 amps with UL489A Listing, but is not recommended over 20 amps. 7 Terminal Codes 3, 5 and H (Bus Type) with TUV or VDE, are supplied with Lock Washers, and Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only TUV or VDE Certified when the washers are used. 8 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps with VDE Certification and 50 amps with UL489A Listing. 9 Terminal Code Q not available with VDE certification. 10 Color shown is Visi and Legend with remainder of rocker black. Dual = ON-OFF/I-O legend. 11 Legend on Push-to-reset bezel/shroud is white with single color actuator codes R & U. 12 Legend on Push-To-Reset bezel/shroud matches Visi-Color of rocker with actuator codes N & O. Rockerguard available with actuator codes C through K Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com 20 | A-Series Circuit Breaker - Recessed Paddle - Ordering Scheme A Y 2 1 Series 2 Actuator B 0 4 Circuit 3 Poles 24 5 Auxiliary Switch 6 Frequency & Delay 1 SERIES A 2 ACTUATOR 1 Y Single Color Recessed Paddle Actuator with Vertical Legends 3 POLES 2 1 One 2 4 CIRCUIT A Switch-Only (No Coil) B Series Trip (Current) C Series Trip (Voltage) D Shunt Trip (Current) E Shunt Trip (Voltage) 3 Two F G H K Three Relay Trip (Current) Relay Trip (Voltage) Dual Coil with Shunt Trip Voltage Coil Dual Coil with Shunt Trip Current Coil 22 24 26 42 44 46 52 54 56 50/60 Hz Short 50/60 Hz Medium 50/60 Hz Long 50/60 Hz Short Hi-Inrush 50/60 Hz Medium Hi-Inrush 50/60 Hz Long Hi-Inrush DC, Short, Hi-Inrush DC, Medium, Hi-Inrush DC, Long, Hi-Inrush 7 CURRENT RATING (AMPERES) 4 CODE AMPERES 220 0.200 295 0.950 460 6.000 225 0.250 410 1.000 465 6.500 230 0.300 512 1.250 470 7.000 235 0.350 415 1.500 475 7.500 240 0.400 517 1.750 480 8.000 245 0.450 420 2.000 485 8.500 250 0.500 522 2.250 490 9.000 255 0.550 425 2.500 495 9.500 260 0.600 527 2.750 610 10.000 265 0.650 430 3.000 710 10.500 270 0.700 435 3.500 611 11.000 275 0.750 440 4.000 711 11.500 280 0.800 445 4.500 612 12.000 285 0.850 450 5.000 712 12.500 290 0.900 455 5.500 613 13.000 OR VOLTAGE COIL (NORMAL RATED VOLTAGE) 614 615 616 617 618 620 622 624 625 630 635 640 645 650 14.000 15.000 16.000 17.000 18.000 20.000 22.000 24.000 25.000 30.000 35.000 40.000 45.000 50.000 A06 A12 A18 A24 J65 K20 L40 65 AC 120 AC 240 AC CODE AMPERES 6 DC 12 DC 18 DC 24 DC A32 A48 A65 J06 32 DC 48 DC 65 DC 6 AC J12 J18 J24 J48 12 AC 18 AC 24 AC 48 AC 4 2 1 8 Terminal 9 Actuator Color 10 Mounting/ Barriers 8 TERMINAL 1 Push-On 0.250 Tab (Q.C.) C 2 Screw 8-32 with upturned lugs E 3 Screw 8-32 (Bus Type) F 4 Screw 10-32 with upturned lugs 5 Screw 10-32 (Bus Type) G 6 Screw 8-32 with upturned lugs H & 30 bend L 7 Screw 8-32 (Bus Type) M & 30 bend P 8 Screw 10-32 with upturned lugs Q & 30 bend R 9 Screw 10-32 (Bus Type) & 30 bend S B Screw M5 with upturned lugs T 9 ACTUATOR COLOR & LEGEND 5 Actuator Color I-O ON-OFF White A B Black C D Red F G Green H J Blue K L Yellow M N Gray P Q Orange R S 5 AUXILIARY SWITCH 0 without Aux Switch 1 S.P.D.T. with 0.093 Q.C. Terminals 2 S.P.D.T. with 0.110 Q.C. Terminals 3 S.P.D.T. with 0.139 Solder Lug Terminals 4 S.P.D.T. with 0.110 Q.C. Terminals (Gold Contacts) 5 S.P.D.T. with 0.093 Q.C. Terminals (Gold Contacts) 6 S.P.S.T.-N.O. with 0.139 Solder Lug Terminals 7 S.P.S.T.-N.O. with 0.110 Q.C. Terminals (Gold Contacts) 8 S.P.S.T.-N.O. with 0.187 Q.C. Terminals 9 S.P.D.T. with 0.187 Q.C. Terminals 6 FREQUENCY & DELAY 3 3 DC, 50/60 Hz Switch Only 10 DC Instantaneous 11 DC Ultra Short 12 DC Short 14 DC Medium 16 DC Long 20 50/60 Hz Instantaneous 21 50/60 Hz Ultra Short 620 7 Current Rating C C 11 Max. Appl. Rating 12 Agency Approval Screw, M4 with upturned lugs Screw, M4 (Bus Type) Screw M5 with upturned lugs & 30 bend Screw M5 (Bus Type) & 30 bend Screw M5 (Bus Type) 0.250 Q.C./Solder Lug M6 Threaded Stud Printed Circuit Board Terminals Push-In Stud Screw, M4 with upturned lugs & 30 Bend Screw, M5 with upturned lugs Screw, M4 with upturned lugs Dual 1 2 3 4 5 6 7 8 10 MOUNTING / BARRIERS 1 6-32 x 0.195 inches A 6-32 X 0.195 inches (multi-pole units only) 2 ISO M3 x 5mm B ISO M3 x 5mm (multi-pole units only) Legend Color Black White White White White Black Black Black BARRIERS no yes no yes 11 MAXIMUM APPLICATION RATING 6 A 65 VDC C 120/240 VAC (Available only on 2 or 3-Pole units) K 120 VAC M 80 DC 12 AGENCY APPROVAL 7 A Without Approvals C UL Recognized and CSA Accepted T UL 489A Notes: 1 All standard catalog numbers are supplied with Vertical Legends. For Horizontal or other non-standard legends, choose "X" and order as a special catalog number. 2 For rating (T) 2 & 3 Pole not available. 3 Frequency and Time Delay ratings of (03, 20, 21, 22, 24, 26, 42, 44, 46) not available with approval T. 4 Voltage Coil Ratings starting with (J, K, or L) not available with approval T. 5 "OFF and/or "O" Legends are on Bracket and are only visible when the Paddle Actuator is in the off position. 6 Maximum Application Ratings (C & K) not available with approval T. 7 Not all approvals are available in all constructions. Consult factory for details. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com A-Series Circuit Breaker - Rocker - Circuit & Terminal Diagrams | 21 Circuit & Terminal Diagrams: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance .020 [.51] unless otherwise specified. 3 Schematic shown represents current trip circuit. 4 Circuits shown for >30 amps / VDE. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com 22 | A-Series Circuit Breaker - Rocker - Dimensional Specifications Dimensional Specifications: in. [mm] Notes: 1 Dimensions apply to all variations shown. Notice that circuit breaker line & load terminal orientation on indicate OFF is opposite of indicate ON. 2 For pole orientation with horizontal legend, rotate front view clockwise 90. 3 All dimensions are in inches [millimeters]. 4 Tolerance 0.20 [.51] unless otherwise specified. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com A-Series Circuit Breaker - Rocker Snap-In Bracket - Dimensional Specifications | 23 Dimensional Specifications: in. [mm] Notes: 1 Dimensions apply to all variations shown. Notice that circuit breaker line & load terminal 2 For pole orientation with horizontal legend, rotate front view clockwise 90. Orientation on indicate "OFF" is opposite of indicate "ON" 3 Recommended panel thickness: .04 0 [1.02] to .100 [2.54] 4 All dimensions are in Inches [millimeters]. 5 Tolerance .020 [.51] unless otherwise specified. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com 24 | A-Series Circuit Breaker - Flat Rocker - Dimensional Specifications Dimensional Specifications: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 For pole orientation with horizontal legend, rotate front view clockwise 90. 3 Tolerance 0.20 [.51] unless otherwise specified. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com A-Series Circuit Breaker - Recessed Paddle - Dimensional Specifications | 25 Dimensional Specifications: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance 0.20 [.51] unless otherwise specified Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com 26 | A-Series Circuit Breaker - PC Terminal Diagrams PC Terminal Diagrams: in. [mm] Notes: 1 Drawing illustrates A-Series with VDE certification. 2 All dimensions are in inches [millimeters]. 3 Tolerance 0.20 [.51] unless otherwise specified Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com Sales Representatives, Distributors & Company Profile | 27 Authorized Sales Representatives and Distributors Click on a region of the map below to find your local representatives and distributors or visit www.carlingtech.com/findarep. CANADA EUROPE USA MIDDLE EAST MEXICO AFRICA ASIA-PACIFIC OCEANIA SOUTH AMERICA About Carling Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power distribution systems. With four ISO registered manufacturing facilities and technical sales offices worldwide, Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical components, they engineer powerful solutions! To learn more about Carling please visit www.carlingtech.com/company-profile. To view all of Carling's environmental, quality, health & safety certifications please visit www.carlingtech.com/environmental-certifications Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com Worldwide Headquarters Carling Technologies, Inc. 60 Johnson Avenue, Plainville, CT 06062 Phone: 860.793.9281 Fax: 860.793.9231 Email: sales@carlingtech.com Northern Region Sales Office: nrsm@carlingtech.com Southeast Region Sales Office: sersm@carlingtech.com Midwest Region Sales Office: mrsm@carlingtech.com West Region Sales Office: wrsm@carlingtech.com Latin America Sales Office: larsm@carlingtech.com Asia-Pacific Headquarters Carling Technologies, Asia-Pacific Ltd., Suite 1607, 16/F Tower 2, The Gateway, Harbour City, 25 Canton Road, Tsimshatsui, Kowloon, Hong Kong Phone: Int + 852-2737-2277 Fax: Int + 852-2736-9332 Email: sales@carlingtech.com.hk Shenzhen, China: shenzhen@carlingtech.com Shanghai, China: shanghai@carlingtech.com Pune, India: india@carlingtech.com Kaohsiung, Taiwan: taiwan@carlingtech.com Yokohama, Japan: japan@carlingtech.com Europe | Middle East | Africa Headquarters Carling Technologies LTD 4 Airport Business Park, Exeter Airport, Clyst Honiton, Exeter, Devon, EX5 2UL, UK Phone: Int + 44 1392.364422 Fax: Int + 44 1392.364477 Email: ltd.sales@carlingtech.com Germany: gmbh@carlingtech.com France: sas@carlingtech.com www.carlingtech.com REV_05_2017 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Carling Technologies: AC1-B0-34-620-5F1-C AF1-B0-22-620-2G3-C AA1-B0-34-250-3B1-C AA1-B0-34-050-3B1-C A11-B0-34-630-131-E AA1-B0-34-615-3B1-C AC1-B0-34-610-1G1-C AC1-B0-34-620-131-D A11-B0-34-610-131-E A12-B0-34-450-131-E AC1-B0-34-630-131-D AC3-B0-24-630-1G1-C A12-B0-34-630-131-E A11-B0-34-625-131-E A11-B0-34-620-131-E A11-B0-34-450-131-E AJ1-B0-14-635-523-C AA1-B0-34-625-3B1-C A12-B0-34-620-131-E AC1-B0-34-450-1G1-C AA1-B0-34-650-5B1-C AF1-B0-34-625-1G1-C AA1-B0-34-610-3B1-C AF1-B0-34-620-1G1-C AA1-B0-34-620-3B1-C A12-B0-34-610-131-E AC1-B0-34-620-111-C AC1-B0-34-620-1G1-C A12-B0-34-615-131-E AC1-B0-34-615-131-D A11-B0-34-615-131-E AC1-B0-34-630-1G1-C A12-B0-34-625-131-E AC1-B0-34-610-131-D AF1-B0-34-630-1G1-C AA1-B0-34-630-3B1-C AC1-B0-34-625-1G1-C AF1-B2-34-650-531-C AC1-B0-34-615-1G1-C AB2-B0-46-440-1B1-C AC1-B0-34-630-5F1-C AE1-B0-34-620-331-C AE1-B0-34-610-331-C AA1-B0-14-630-4B1-C AA1-B1-12-610-1B1-C AA1-B1-12-620-1B1-C AA1-B1-14-420-1B1-C AA2-X0-16-282-421-4 AC2-B0-46-620-2FD-D AF2-B0-24-615-131-C AF3-B0-24-615-111-D AJ2-B0-24-630-521-D AJ2-B0-34-620-123-D AM1-B0-34-615-101-C AM1-B0-34-620-101-C AM1-B0-34-625-101-C AM1-B0-34-630-101-C AA1-B0-34-630-3B2-C AA1-B0-10-250-2D1-C AA1-B0-10-425-2D1-C AA1-B0-11-250-2D1-C AA1-B0-11-425-2D1-C AA1-B0-12-615-1B1-C AA1-B0-14-615-1B1-C AA1-B0-20-425-1B2-C AA1-B0-24-615-3D1-C AA1-B0-26-625-1B1-C AA1-B0-34-450-5D1-C AA1-B0-34-475-3D1-C AA1-B0-34-610-1B1-C AA1-B0-34-610-3D1-C AA1-B0-34-610-5D1-C AA1-B0-34-615-3D1-C AA1-B0-34-615-5D1-C AA1-B0-34-620-3D1-C AA1-B0-34-620-5D1-C AA1-B0-34-630-1B1-C AA1-B0-34-630-3D1-C AA1-B0-34-630-5D1-C AA1-B0-34-640-5B1-C AA1-B0-34-650-5D1-C AA1-B0-46-620-1B1-C AA1-B1-12-615-1B1-C AA1-X0-00-652-9D1-C AA2-B0-24-410-1B1-C AA2-B0-24-625-3B1-C AA2-B0-24-630-1B2-C AA2-B0-26-630-1B1-C AA2-B0-34-615-1B1-C AA2-B0-34-620-3G1-C AA2-B0-34-650-5G1-C AA2-B0-44-625-5D3-C AA5-X0-00-056-4D1-A AB2-A0-03-630-2D1-C AB2-B0-26-615-3D1-C AB2-B0-26-640-5D1-C AB2-B0-34-630-5D1-C AB2-X0-03-182-1B1-C AC1-B0-34-610-1G2-C AC1-B0-34-650-5F1-C