SPECIFICATION
PPT-125A PPT-125B PPT-125C PPT-125D
MODEL
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE(convection)
CURRENTRANGE(18CFMFAN)
RATEDPOWER(convection)
RATEDPOWER(18CFMFAN)
OUTPUT
VOLTAGE ADJ.RANGE
LINEREGULATION
LOADREGULATION
SETUP,RISETIME
HOLDUP TIME (Typ.)
VOLTAGERANGE
FREQUENCY RANGE
POWERFACTOR (Typ.)
EFFICIENCY (Typ.)
INPUT
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
SAFETY STANDARDS
HARMONICCURRENT
EMSIMMUNITY
WORKINGTEMP.,HUMIDITY
WORKINGTEMP.
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
ACCURRENT (Typ.)
3.3V 5V
CH2
12V
CH3
5V
CH1
12V
CH2
-12V
CH3
5V
CH1
15V
CH2
-15V
CH3
5V
CH1
24V
CH2
12V
CH3
10A 8A 0.5A 11.5A 3A 0.5A 11A 2.5A 0.5A 7A 2.5A 0.5A
1~10A
1~12.5A
0.8~8A
0.8~10A
0.05~0.5A
0.05~0.63A
1~11.5A
1~14.38A
0.3~3A
0.3~3.75A
0.05~0.5A
0.05~0.63A
1~11A
1~13.75A
0.25~2.5A
0.25~3.13A
0.05~0.5A
0.05~0.63A
1~7A
1~8.75A
0.25~2.5A
0.25~3.13A
0.05~0.5A
0.05~0.63A
79W
98.8W
99.5W
124.46W
100W
125.15W
101W
126.43W
100mVp-p 100mVp-p 120mVp-p 100mVp-p 120mVp-p 120mVp-p 100mVp-p 150mVp-p 150mVp-p 100mVp-p 240mVp-p 120mVp-p
CH1:3.13~3.46V CH1:4.75~5.25V CH1:4.75~5.25V CH1:4.75~5.25V
3.0%
3.0%
5.0%
3.0%
6.0%
5.0%
3.0% 5.0% 6.0% 3.0% 5.0% 6.0% 3.0% 5.0% 6.0%
0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5%
3.0% 3.0% 5.0% 3.0% 3.0% 5.0% 3.0% 3.0% 5.0%
1000ms,30ms/230VAC2000ms,30ms/115VACatfullload
24ms/230VAC24ms/115VACatfullload
90~264VAC127~370VDC
47~63Hz
PF>0.93/230VACPF>0.98/115VACatfullload
75% 78% 78% 78%
1.7A/115VAC0.75A/230VAC
COLDSTART 24A/230VAC
<2mA /240VAC
130~160% ratedoutputpower
CH1:3.6~4.45V CH1:5.75~6.75V CH1:5.75~6.75V CH1:5.75~6.75V
Protectiontype:Foldbackcurrentlimiting,recoversautomaticallyafterfaultconditionisremoved
Protectiontype: Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
UL60950-1, TUVEN60950-1approved
CompliancetoEN55022(CISPR22)ClassB
Complianceto EN61000-3-2,-3
CompliancetoEN61000-4-2,3,4,5,6,8,11;ENV50204,EN55024,lightindustrylevel,criteria A
-20~+70 (Refertooutputloadderatingcurve)
20~90%RHnon-condensing
-40~+85 ,10~95%RH
0.05%/ (0~50
10~500Hz,2G10min./1cycle,60min.eachalongX, Y,Zaxes
94.7Khrsmin.MIL-HDBK-217F(25 )
127*76.2*34.6mm(L*W*H)
0.37Kg;36pcs/14.3Kg/0.79CUFT
125W TripleOutputwithPFCFunction
Universal AC input / Full range
Built-in active PFC function
Protections: Short circuit / Overload / Over voltage
PWM control and regulated
High power density 6.117W/inch
LED indicator for power on
100% full load burn-in test
125W with 18CFM FAN
5"x3" compact size
3 years warranty
3
Features :
PPT-125 series
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC /25 /70%RH
SAFETY &
EMC
(Note4)
PROTECTION
ENVIRONMENT
EMICONDUCTION&RADIATION
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Heat Sink HS1,HS2 & HS3 can not be shorted.
For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
CH1
OUTPUTNUMBER
FileName:PPT-125-SPEC2010-10-18
http://store.iiic.cc/