Specifications are subject to change without notice (09.12.01) 1
Proximity Sensors Inductive
Thermoplastic Polyester Housing
Types EI, DC, M12, M18, M30
Euronorm thermoplastic polyester housing,
cylindrical
Diameter: M12, M18, M30.
Sensing distance: 2 to 15 mm
Power supply: 10 to 40 VDC
20 to 250 VAC
Output: Transistor NPN/PNP, make or break switching
SPDT relay, make & break switching
•Protection: Short-circuit, reverse polarity and overload
LED-indication for output ON
•2 m cable or M12 plug
Product Description
euronorms EN 50 008 and
EN 50 036. For metal versions
refer to type. EI ...S.
Proximity switch in M12, M18
and M30 polyester housings.
Made in accordance with
Type
Housing diameter (mm)
Rated operating dist. (mm)
Output type
Housing material
Body style
Plug
Type Selection DC Types, Cable and M12 Plug
Housing Body Connec- Rated Ordering no. Ordering no. Ordering no. Ordering no.
diameter style tion operating Transistor NPN Transistor NPN Transistor PNP Transistor PNP
dist. (Sn)Make switching Break switching Make switching
Break switching
M12 Short Cable 2 mm 1) EI 1202 NPOPS EI 1202 NPCPS EI 1202 PPOPS EI 1202 PPCPS
M12 Short Plug 2 mm 1) EI 1202 NPOPS-1 EI 1202 NPCPS-1 EI 1202 PPOPS-1 EI 1202 PPCPS-1
M12 Long Cable 2 mm 1) EI 1202 NPOPL EI 1202 NPCPL EI 1202 PPOPL EI 1202 PPCPL
M12 Long Plug 2 mm 1) EI 1202 NPOPL-1 EI 1202 NPCPL-1 EI 1202 PPOPL-1 EI 1202 PPCPL-1
M12 Short Cable 4 mm 2) EI 1204 NPOPS EI 1204 NPCPS EI 1204 PPOPS EI 1204 PPCPS
M12 Short Plug 4 mm 2) EI 1204 NPOPS-1 EI 1204 NPCPS-1 EI 1204 PPOPS-1 EI 1204 PPCPS-1
M12 Long Cable 4 mm 2) EI 1204 NPOPL EI 1204 NPCPL EI 1204 PPOPL EI 1204 PPCPL
M12 Long Plug 4 mm 2) EI 1204 NPOPL-1 EI 1204 NPCPL-1 EI 1204 PPOPL-1 EI 1204 PPCPL-1
M18 Short Cable 5 mm 1) EI 1805 NPOPS EI 1805 NPCPS EI 1805 PPOPS EI 1805 PPCPS
M18 Short Plug 5 mm 1) EI 1805 NPOPS-1 EI 1805 NPCPS-1 EI 1805 PPOPS-1 EI 1805 PPCPS-1
M18 Long Cable 5 mm 1) EI 1805 NPOPL EI 1805 NPCPL EI 1805 PPOPL EI 1805 PPCPL
M18 Long Plug 5 mm 1) EI 1805 NPOPL-1 EI 1805 NPCPL-1 EI 1805 PPOPL-1 EI 1805 PPCPL-1
M18 Short Cable 8 mm 2) EI 1808 NPOPS EI 1808 NPCPS EI 1808 PPOPS EI 1808 PPCPS
M18 Short Plug 8 mm 2) EI 1808 NPOPS-1 EI 1808 NPCPS-1 EI 1808 PPOPS-1 EI 1808 PPCPS-1
M18 Long Cable 8 mm 2) EI 1808 NPOPL EI 1808 NPCPL EI 1808 PPOPL EI 1808 PPCPL
M18 Long Plug 8 mm 2) EI 1808 NPOPL-1 EI 1808 NPCPL-1 EI 1808 PPOPL-1 EI 1808 PPCPL-1
M30 Short Cable 10 mm 1) EI 3010 NPOPS EI 3010 NPCPS EI 3010 PPOPS EI 3010 PPCPS
M30 Short Plug 10 mm 1) EI 3010 NPOPS-1 EI 3010 NPCPS-1 EI 3010 PPOPS-1 EI 3010 PPCPS-1
M30 Long Cable 10 mm 1) EI 3010 NPOPL EI 3010 NPCPL EI 3010 PPOPL EI 3010 PPCPL
M30 Long Plug 10 mm 1) EI 3010 NPOPL-1 EI 3010 NPCPL-1 EI 3010 PPOPL-1 EI 3010 PPCPL-1
M30 Short Cable 15 mm 2) EI 3015 NPOPS EI 3015 NPCPS EI 3015 PPOPS EI 3015 PPCPS
M30 Short Plug 15 mm 2) EI 3015 NPOPS-1 EI 3015 NPCPS-1 EI 3015 PPOPS-1 EI 3015 PPCPS-1
M30 Long Cable 15 mm 2) EI 3015 NPOPL EI 3015 NPCPL EI 3015 PPOPL EI 3015 PPCPL
M30 Long Plug 15 mm 2) EI 3015 NPOPL-1 EI 3015 NPCPL-1 EI 3015 PPOPL-1 EI 3015 PPCPL-1
1) For flush mounting in metal Make switching = Normally Open (NO)
2) For non-flush mounting in metal Break switching = Normally Closed (NC)
Ordering Key
EI 1202 NPOPS-1
2Specifications are subject to change without notice (09.12.01)
EI, DC, M12, M18, M30, Cable
Type Selection Relay Output
Housing Rated Ordering no. Ordering no. Ordering no. Ordering no.
diameter operating Make & break swit. Make & break swit. Make & break swit. Make & break swit.
dist. (Sn)12 VAC/DC 24 VAC/DC 115 VAC 230 VAC
30 mm 10 mm 1) EI 3010 RNAP 912 EI 3010 RNAP 924 EI 3010 RNAP 115 EI 3010 RNAP 230
30 mm 15 mm 2) EI 3015 RNAP 912 EI 3015 RNAP 924 EI 3015 RNAP 115 EI 3015 RNAP 230
1) For flush mounting in metal Make switching = Normally Open (NO)
2) For non-flush mounting in metal Break switching = Normally Closed (NC)
Specifications
Transistor NPN/PNP SPDT relay
Rated operational volt. (Ue)12 to 36 VDC 912: 10.8 to 13.2 VAC/DC, 50 to 60 Hz
(UB)10 to 40 VDC (ripple incl.) 924: 21.6 to 26.2 VAC/DC, 50 to 60 Hz
115: 97 to 135 VAC, 50 to 60 Hz
230: 207 to 250 VAC, 50 to 60 Hz
Ripple 10% -
Rated operational current (Ie)
Continuous 200 mA 2 A
Short-time 10 A, max. 25 ms
Max. power -AC: 760 VA DC: 150 W
No-load supply current (Io)Output ON: < 6.5 mA 12 VAC/DC: 65/35 mA
Output OFF: < 2.7 mA 24 VAC/DC: 34/13 mA
115 VAC: 16 mA
230 VAC: 16 mA
Voltage drop (Ud)2 VDC at max. load -
Protection Reverse polarity, short-circuit, transients None
Transient voltage 700 V/0.5 J 1 kV/0.5 J (prepared)
EMC
Approved acc. to EN 50 080, EN 50 081
-
Power ON delay < 10 ms 60 ms
Frequency of operating cycles (f) EI 1202 800 Hz EI 1808 400 Hz 10 Hz
EI 1204 500 Hz EI 3010 300 Hz
EI 1805 500 Hz EI 3015 100 Hz
Indication for output ON LED, yellow LED, yellow
Assured operating dist. (Sa)0 Sa0.81 Sn0 Sa0.81 Sn
Repeat accuracy (R) 5% 5%
Hysteresis (H) (Differential travel)
1 to 15% of sensing distance 3 to 20% of sensing distance
Effective operating dist. (Sr)0.9 x SnSr1.1 x Sn0.9 x SnSr1.1 x Sn
Usable operating dist. (S) 0.9 x SrSu1.1 x Sr0.9 x SrSu1.1 x Sr
Ambient temperature
Operating
-25° to +70°C (-13° to +158°F) -25° to +70°C (-13° to
+158°F)
Storage
-30° to +80°C (-22° to +176°F) -30° to +80°C (-22° to +176°F)
Degree of protection IP 67 (Nema 1, 3, 4, 6, 13) IP 67 (Nema 1, 3, 4, 6, 13)
Housing material
Body Grey thermoplastic polyester
Blue thermoplastic polyester
Back Black polyester
Blue thermoplastic polyester
Connection
Cable 2 m, 3 x 0.3 mm2, grey PVC, oil proof 2 m, 5 x 0.50 mm2, grey PVC, oil proof
Plug M 12 x 1
Cables for plug (-1) CONH1A serie
Weight (cable excluded) EI 12 10 g EI 3010 50 g 180 g
EI 1805 18 g EI 3015 70 g
EI 1808 20 g
Tightening torque EI 12 1.8 Nm EI 30 7.5 Nm 7.5 Nm
EI 18 2.6 Nm
Approvals UL, CSA UL, CSA
CE-marking Yes Ye s
Specifications are subject to change without notice (09.12.01) 3
EI, DC, M12, M18, M30
Dimensions
Type A B C D E F G H I SW K L
Ø mm mm mm mm mm mm mm mm mm Ø mm Ø mm
EI 1202 XPXPS M 12 x 1 x 30 10.7 30 11 5.0 8 17
EI 1202 XPXPL M 12 x 1 x 50 10.7 50 11 5.0 8 17
EI 1202 XPXPS-1 M 12 x 1 x 30 10.7 30 12.6 11.9 8 17
EI 1202 XPXPL-1 M 12 x 1 x 50 10.7 50 12.6 11.9 8 17
EI 1204 XPXPS M 12 x 1 x 30 10.7 34 11 5.0 8 17
EI 1204 XPXPL M 12 x 1 x 50 10.7 54 11 5.0 8 17
EI 1204 XPXPS-1 M 12 x 1 x 30 10.7 34 12.6 11.9 8 17
EI 1204 XPXPL-1 M 12 x 1 x 50 10.7 54 12.6 11.9 8 17
EI 1805 XPXPS M 18 x 1 x 30 16.7 30 11.6 15.4 8 24
EI 1805 XPXPL M 18 x 1 x 50 16.7 50 11.6 15.4 8 24
EI 1805 XPXPS-1 M 18 x 1 x 30 16.7 30 13.1 11.9 8 24
EI 1805 XPXPL-1 M 18 x 1 x 50 16.7 50 13.1 11.9 8 24
EI 1808 XPXPS M 18 x 1 x 30 16.7 38 11.6 15.4 8 24
EI 1808 XPXPL M 18 x 1 x 50 16.7 58 11.6 15.4 8 24
EI 1808 XPXPS-1 M 18 x 1 x 30 16.7 38 13.1 11.9 8 24
EI 1808 XPXPL-1 M 18 x 1 x 50 16.7 58 13.1 11.9 8 24
EI 3010 XPXPS M 30 x 1.5 x 30 28 30 13.6 15.4 10 36
EI 3010 XPXPL M 30 x 1.5 x 50 28 50 13.6 15.4 10 36
EI 3010 XPXPS-1 M 30 x 1.5 x 30 28 30 13.6 11.9 10 36
EI 3010 XPXPL-1 M 30 x 1.5 x 50 28 50 13.6 11.9 10 36
EI 3015 XPXPS M 30 x 1.5 x 30 28 42 13.6 15.4 10 36
EI 3015 XPXPL M 30 x 1.5 x 50 28 62 13.6 15.4 10 36
EI 3015 XPXPS-1 M 30 x 1.5 x 30 28 42 13.6 11.9 10 36
EI 3015 XPXPL-1 M 30 x 1.5 x 50 28 62 13.6 11.9 10 36
RNAP
EI 3010 M 30 x 1.5 28.16 80 19.5 2000 1 59 20 10 36 15 6.7
EI 3015 M 30 x 1.5 28.16 80 19.5 2000 12 48 20 10 36 15 6.7
Cable
EI 30 .. RNAP
A
ISW
CDE
LED
B
F
SW A
Plug
CDE
LED
B
F
SW A
M 12 x 1
4Specifications are subject to change without notice (09.12.01)
Installation Hints
Relief of cable strain Protection of the sensing face Switch mounted on mobile carrierTo avoid interference from inductive voltage/
current peaks, separate the prox. switch pow-
er cables from any other power cables, e.g.
motor, contactor or solenoid cables Incorrect
Correct
The cable should not be pulled A proximity switch should not serve as
mechanical stop
Any repetitive flexing of the
cable should be avoided
Wiring Diagrams
+
-
1 BN
4 BK
3 BU
+
-
1 BN
2 WH
3 BU
+
-
1 BN
4 BK
3 BU
+
-
1 BN
2 WH
3 BU
NPN - Make switching NPN - Break switching PNP - Make switching PNP - Break switching
Power Supplies
Power supplies VAC: > SS 110.
Power supplies VDC: > SS 130/140.
Power supplies with amplifier relays: > SV 190.
EI, DC, M12, M18, M30