TCXO CCO 100 Typical Applications PCS Base Stations Land Mobile Radio Cellular Telephony Radio in the Local Loop Test Equipment Features EFC Standard Standard (20 x 20mm) Package Hermetically Sealed Package Wide Temperature Range High Stability Frequency Range 0.5 MHz - 80 MHz Standard Frequencies 10; 16.384;19.44; 38.88; 77.76 MHz Frequency stabilities Parameter vs. Operating temperature range Code I Frequency stability Operating temp range 07 08 03 04 05 06 2.0 ppm 1.0 ppm 2.0 ppm 1.0 ppm 1.0 ppm 0.5 ppm -40....+85 Parameter vs. Supply voltage change vs. Load change vs. Aging / year -20....+70C 0....50C Value Condition < 0.2 ppm < 0.1 ppm < 1.0 ppm VS 5% Load 5% Frequency tuning Parameter Option Value Condition T > 5.0 ppm > 5.0 ppm 0.0 V to 2.0 V negative >10 k (internal trimmer) Note 1 @ VS = 5.0 V & 3.3 V Code III Value Condition 06 HCMOS 25pF 10% 15pF 10% 40/60% < -45 dBc @ < 20 MHz @ 20 MHz @ VS/2 @ > 33 MHz Code II Value Condition Supply voltage (VS) Current consumption 05 Supply voltage (VS) Current consumption 33 5.0 V 5% 3 mA to 10 mA 5 mA to 50mA 3.3 V 5% 3 mA to 10 mA 5 mA to 50 mA Mechanical (No EFC) Electrical freq. control (EFC) Voltage range Pulling slope Freq. control input impedance U RF output Parameter Signal Load Duty cycle Subharmonics Supply voltage Parameter Corning Frequency Control * Worldwide Data Book 2001 Sinewave HCMOS Sinewave HCMOS v1.0.2000-11-01 Corning Frequency Control Inc. * 100 Watts Street * Mt. Holly Springs, PA 17065 * Tel 1-717-486-3411 * Fax 1-717-486-5920 * www.corningfrequency.com Tele Quarz GmbH & Co. KG * Landstrasse * D-74924 Neckarbischofsheim, Germany * Tel +49-7268-801-0 * Fax +49-07268-801-281 * www.telequarz.de 1/2 TCXO CCO 100 Additional parameters Parameter Value Phase Noise Condition <- 105 dBc/Hz <-135 dBc/Hz <-145 dBc/Hz <-150 dBc/Hz <-155 dBc/Hz < 10 g -40 ... +90C -55 ... +105C Weight Operable temperature range Storage temperature range Processing & Packing 10 100 1 10 100 Hz Hz kHz kHz kHz Note 2 handling&processing note Enclosure Type G143 Drawing 15,24 7,62 0,5 0,5 G143 1 2 3 H = 10,5max.; G143 Standard 5,0 3,5 option 4 5 o0,45 4,5min. 0,5max. H 5,0 20,5max. all units in mm Pin Connections Pin 1 Pin Pin Pin Pin Pin 2 3 4 4 5 Ordering Code Model Example: Order: Notes 1 2 CC0100 CCO100 Supply Voltage (Vs) RF output GND, case Control Voltage (Vc) N.C. N.C. Option Frequency tuning T Code I Frequency Stability 03. Option U Option T Code II Supply Voltage 05. Electrical freq. Control Mechanical freq. Control Code III RF Output 02. Frequency 10M00000 Other available Typical values @ 10 MHz Unless otherwise stated all values are valid after warm-up time and refer to typical conditions for supply voltage, frequency control voltage, load, temperature (25C) Subject to technical modification; Not all options are available at all Frequencies Corning Frequency Control * Worldwide Data Book 2001 v1.0.2000-11-01 Corning Frequency Control Inc. * 100 Watts Street * Mt. Holly Springs, PA 17065 * Tel 1-717-486-3411 * Fax 1-717-486-5920 * www.corningfrequency.com Tele Quarz GmbH & Co. KG * Landstrasse * D-74924 Neckarbischofsheim, Germany * Tel +49-7268-801-0 * Fax +49-07268-801-281 * www.telequarz.de 2/2