MODEL LDA10F-3 LDA10F-5 LDA10F-12 LDA10F-15 LDA10F-24
MAX OUTPUT WATTAGE[W] 6 10 10.8 10.5 12
DC OUTPUT 3V 2.0A 5V 2.0A 12V 0.9A 15V 0.7A 24V 0.5A
SPECIFICATIONS
MODEL LDA10F-3 LDA10F-5 LDA10F-12 LDA10F-15 LDA10F-24
INPUT
VOLTAGE[V] AC85 - 264 1for DC110 - 370
CURRENT[A]
ACIN 100V
0.25typ (Io=100%)
ACIN 200V
0.16typ (Io=100%)
FREQUENCY[Hz] 47 - 440 or DC
EFFICIENCY[%] 68typ 72typ 74typ 74typ 78typ
INRUSH CURRENT[A]
ACIN 100V
15typ (Io=100%)(
At cold start)
ACIN 200V
30typ (Io=100%)(
At cold start)
LEAKAGE CURRENT[mA] 0.75max (60Hz,According to UL,CSA,VDE and DEN-AN)
OUTPUT
VOLTAGE[V] 3 5 12 15 24
CURRENT[A] 2 2 0.9 0.7 0.5
LINE REGULATION[mV] 20max 20max 48max 60max 96max
LOAD REGULATION[mV] 40max 40max 100max 120max 150max
RIPPLE[mVp-p]
0to+50
C
80max 80max 120max 120max 120max
-10-0
C
140max 140max 160max 160max 160max
RIPPLE NOISE[mVp-p]
0to+50
C
120max 120max 150max 150max 150max
-10-0
C
160max 160max 180max 180max 180max
TEMPERATURE REGULATION[mV]
50max 50max 120max 150max 240max
DRIFT[mV]
*1
20max 20max 48max 60max 96max
START-UP TIME[ms] 200max (ACIN 100V,Io=100%)
HOLD-UP TIME[ms] 10typ (ACIN 85V,Io=100%)20typ (ACIN 100V,Io=100%)100typ (ACIN 200V,Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
2.85 - 3.6 Fixed ("Y"which can be adjusted the output is available as option :5,12,15,24V t10%)
OUTPUT VOLTAGE SETTING[V]
xx 4.9 - 5.3 11.5 - 12.5 14.4 - 15.6 23.0 - 25.0
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION
4.00V min Works over 115% of rating,by zener diode clamping
OPERATING INDICATION Not provided
REMOTE SENSING Not provided
REMOTE ON/OFF Not provided
ISOLATION
INPUT-OUTPUT AC3,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-FG AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-10 to +60C,20 - 90%RH (Non condensing)(
Refer to DERATING CURVE)3,000m (10,000feet)max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C,20 - 90%RH (Non condensing)9,000m (30,000feet)max
VIBRATION 10 - 55Hz,19.6m/s2(2G), 3minutes period,60minutes each along X,Y and Z axis
IMPACT 196.1m/s2(20G), 11ms,once each X,Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS UL60950-1,EN60950-1,EN50178,CSA C22.2 No.60950-1 Complies with DEN-AN and IEC60950-1
CONDUCTED NOISE Complies with FCC-B,CISPR22-B,EN55022-B,VCCI-B
OTHERS CASE SIZE/WEIGHT 50X21X105mm (WXHXD)/75g max (without chassis and cover)
COOLING METHOD Convection
*1Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
*2Please contact us about safety approvals for the model with option.
*Avoid prolonged use under over-load.
*Series/Parallel operation with other model is not possible.
*Derating is required when operated with chassis and cover.
LDA10F
AC-DC Power Supplies Open Frame/Enclosed type
LDA 10 F -5 -O
Ordering information
1Series name
2Output wattage
3Universal input
4Output voltage
5Optional *2
C :with Coating
G :Low leakage current
S :with Chassis
SN
:with Chassis & cover
Y :with Potentiometer
R
12345
LDA
LDA-2
Recommended EMI/EMC Filter
NAC-06-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended
*to connect with several devices.
¡OVERCURRENT CHARACTERISTICS (LDA10F-5)
¡STATIC CHARACTERISTICS (LDA10F-5)¡RISE TIME & FALL TIME (LDA10F-5)
¡DERATING CURVE
LDA
LDA-3
LDA10F
External view
Performance data
MODEL LDA15F-3 LDA15F-5 LDA15F-12 LDA15F-15 LDA15F-24
MAX OUTPUT WATTAGE[W] 9 15 15.6 15 16.8
DC OUTPUT 3V 3.0A 5V 3.0A 12V 1.3A 15V 1.0A 24V 0.7A
SPECIFICATIONS
MODEL LDA15F-3 LDA15F-5 LDA15F-12 LDA15F-15 LDA15F-24
INPUT
VOLTAGE[V] AC85 - 264 1for DC110 - 370
CURRENT[A]
ACIN 100V
0.37typ (Io=100%)
ACIN 200V
0.23typ (Io=100%)
FREQUENCY[Hz] 47 - 440 or DC
EFFICIENCY[%] 70typ 74typ 76typ 76typ 78typ
INRUSH CURRENT[A]
ACIN 100V
15typ (Io=100%)(
At cold start)
ACIN 200V
30typ (Io=100%)(
At cold start)
LEAKAGE CURRENT[mA] 0.75max (60Hz,According to UL,CSA,VDE and DEN-AN)
OUTPUT
VOLTAGE[V] 3 5 12 15 24
CURRENT[A] 3 3 1.3 1 0.7
LINE REGULATION[mV] 20max 20max 48max 60max 96max
LOAD REGULATION[mV] 40max 40max 100max 120max 150max
RIPPLE[mVp-p]
0to+50
C
80max 80max 120max 120max 120max
-10-0
C
140max 140max 160max 160max 160max
RIPPLE NOISE[mVp-p]
0to+50
C
120max 120max 150max 150max 150max
-10-0
C
160max 160max 180max 180max 180max
TEMPERATURE REGULATION[mV]
50max 50max 120max 150max 240max
DRIFT[mV]
*1
20max 20max 48max 60max 96max
START-UP TIME[ms] 200max (ACIN 100V,Io=100%)
HOLD-UP TIME[ms] 10typ (ACIN 85V,Io=100%)20typ (ACIN 100V,Io=100%)100typ (ACIN 200V,Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
2.85 - 3.6 Fixed ("Y"which can be adjusted the output is available as option :5,12,15,24V t10%)
OUTPUT VOLTAGE SETTING[V]
xx 4.9 - 5.3 11.5 - 12.5 14.4 - 15.6 23.0 - 25.0
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION
4.00V min Works over 115% of rating,by zener diode clamping
OPERATING INDICATION Not provided
REMOTE SENSING Not provided
REMOTE ON/OFF Not provided
ISOLATION
INPUT-OUTPUT AC3,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-FG AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-10 to +60C,20 - 90%RH (Non condensing)(
Refer to DERATING CURVE)3,000m (10,000feet)max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C,20 - 90%RH (Non condensing)9,000m (30,000feet)max
VIBRATION 10 - 55Hz,19.6m/s2(2G), 3minutes period,60minutes each along X,Y and Z axis
IMPACT 196.1m/s2(20G), 11ms,once each X,Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS UL60950-1,EN60950-1,EN50178,CSA C22.2 No.60950-1 Complies with DEN-AN and IEC60950-1
CONDUCTED NOISE Complies with FCC-B,CISPR22-B,EN55022-B,VCCI-B
OTHERS CASE SIZE/WEIGHT 50X21X125mm (WXHXD)/95g max (without chassis and cover)
COOLING METHOD Convection
*1Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
*2Please contact us about safety approvals for the model with option.
*Avoid prolonged use under over-load.
*Series/Parallel operation with other model is not possible.
*Derating is required when operated with chassis and cover.
LDA15F
AC-DC Power Supplies Open Frame/Enclosed type
LDA 15 F -5 -O
Ordering information
1Series name
2Output wattage
3Universal input
4Output voltage
5Optional *2
C :with Coating
G :Low leakage current
S :with Chassis
SN
:with Chassis & cover
Y :with Potentiometer
R
12345
LDA
LDA-4
Recommended EMI/EMC Filter
NAC-06-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended
*to connect with several devices.
¡OVERCURRENT CHARACTERISTICS (LDA15F-5)
¡STATIC CHARACTERISTICS (LDA15F-5)¡RISE TIME & FALL TIME (LDA15F-5)
¡DERATING CURVE
LDA
LDA-5
LDA15F
External view
Performance data
MODEL LDA30F-3 LDA30F-5 LDA30F-12 LDA30F-15 LDA30F-24
MAX OUTPUT WATTAGE[W] 18 30 30 30 31.2
DC OUTPUT 3V 6.0A 5V 6.0A 12V 2.5A 15V 2.0A 24V 1.3A
SPECIFICATIONS
MODEL LDA30F-3 LDA30F-5 LDA30F-12 LDA30F-15 LDA30F-24
INPUT
VOLTAGE[V] AC85 - 264 1for DC110 - 370
CURRENT[A]
ACIN 100V
0.8typ (Io=100%)
ACIN 200V
0.4typ (Io=100%)
FREQUENCY[Hz] 47 - 440 or DC
EFFICIENCY[%] 70typ 75typ 77typ 78typ 79typ
INRUSH CURRENT[A]
ACIN 100V
15typ (Io=100%)(
At cold start)
ACIN 200V
30typ (Io=100%)(
At cold start)
LEAKAGE CURRENT[mA] 0.75max (60Hz,According to UL,CSA,VDE and DEN-AN)
OUTPUT
VOLTAGE[V] 3 5 12 15 24
CURRENT[A] 6 6 2.5 2 1.3
LINE REGULATION[mV] 20max 20max 48max 60max 96max
LOAD REGULATION[mV] 40max 40max 100max 120max 150max
RIPPLE[mVp-p]
0to+50
C
80max 80max 120max 120max 120max
-10-0
C
140max 140max 160max 160max 160max
RIPPLE NOISE[mVp-p]
0to+50
C
120max 120max 150max 150max 150max
-10-0
C
160max 160max 180max 180max 180max
TEMPERATURE REGULATION[mV]
60max 60max 150max 180max 290max
DRIFT[mV]
*1
20max 20max 48max 60max 96max
START-UP TIME[ms] 200max (ACIN 100V,Io=100%)
HOLD-UP TIME[ms] 10typ (ACIN 85V,Io=100%)20typ (ACIN 100V,Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
2.85 - 3.6 Fixed ("Y"which can be adjusted the output is available as option :5,12,15,24V t10%)
OUTPUT VOLTAGE SETTING[V]
xx 4.9 - 5.3 11.5 - 12.5 14.4 - 15.6 23.0 - 25.0
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION
4.00 - 5.25V Works at 115 - 140% of rating
OPERATING INDICATION Not provided
REMOTE SENSING Not provided
REMOTE ON/OFF Not provided
ISOLATION
INPUT-OUTPUT AC3,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-FG AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-10 to +60C,20 - 90%RH (Non condensing)(
Refer to DERATING CURVE)3,000m (10,000feet)max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C,20 - 90%RH (Non condensing)9,000m (30,000feet)max
VIBRATION 10 - 55Hz,19.6m/s2(2G), 3minutes period,60minutes each along X,Y and Z axis
IMPACT 196.1m/s2(20G), 11ms,once each X,Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS UL60950-1,EN60950-1,EN50178,CSA C22.2 No.60950-1 Complies with DEN-AN and IEC60950-1
CONDUCTED NOISE Complies with FCC-B,CISPR22-B,EN55022-B,VCCI-B
OTHERS CASE SIZE/WEIGHT 55X26X133mm (WXHXD)/200g max (without chassis and cover)
COOLING METHOD Convection
*1Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
*2Please contact us about safety approvals for the model with option.
*Avoid prolonged use under over-load.
*Series/Parallel operation with other model is not possible.
*Derating is required when operated with chassis and cover.
LDA30F
AC-DC Power Supplies Open Frame/Enclosed type
LDA 30 F -5 -O
Ordering information
1Series name
2Output wattage
3Universal input
4Output voltage
5Optional *2
C :with Coating
G :Low leakage current
S :with Chassis
SN
:with Chassis & cover
Y :with Potentiometer
R
12345
LDA
LDA-6
Recommended EMI/EMC Filter
NAC-06-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended
*to connect with several devices.
¡OVERCURRENT CHARACTERISTICS (LDA30F-5)
¡STATIC CHARACTERISTICS (LDA30F-5)¡RISE TIME & FALL TIME (LDA30F-5)
¡DERATING CURVE
LDA
LDA-7
LDA30F
External view
Performance data
MODEL
LDA50F-3 LDA50F-5 LDA50F-9
LDA50F-12 LDA50F-15 LDA50F-18 LDA50F-24
LDA50F-24-H
LDA50F-24-HR
LDA50F-30
MAX OUTPUT WATTAGE[W] 30 50 50.4 51.6 52.5 50.4 50.4 50.4 50.4 51
DC OUTPUT
*3
3V 10A 5V 10A 9V 5.6A 12V 4.3A 15V 3.5A 18V 2.8A 24V 2.1A
24V 2.1(3)A 24V 2.1(3)A
30V 1.7A
SPECIFICATIONS
MODEL
LDA50F-3 LDA50F-5 LDA50F-9
LDA50F-12 LDA50F-15 LDA50F-18 LDA50F-24
LDA50F-24-H
LDA50F-24-HR
LDA50F-30
INPUT
VOLTAGE[V] AC85 - 264 1for DC110 - 370
CURRENT[A]
ACIN 100V
1.3typ (Io=100%)
ACIN 200V
0.7typ (Io=100%)
FREQUENCY[Hz] 47 - 440 or DC
EFFICIENCY[%] 73typ 77typ 78typ 80typ 81typ 81typ 82typ 82typ 82typ 82typ
INRUSH CURRENT[A]
ACIN 100V
15typ (Io=100%)(
At cold start)
ACIN 200V
30typ (Io=100%)(
At cold start)
LEAKAGE CURRENT[mA] 0.75max (60Hz,According to UL,CSA,VDE and DEN-AN)
OUTPUT
VOLTAGE[V] 35912151824242430
CURRENT[A]
*1
10 10 5.6 4.3 3.5 2.8 2.1 2.1 (3)2.1 (3)1.7
LINE REGULATION[mV] 20max 20max 36max 48max 60max 72max 96max 96max 96max 120max
LOAD REGULATION[mV] 40max 40max 100max 100max 120max 120max 150max 150max 150max 180max
RIPPLE[mVp-p]
0to+50
C
80max 80max 120max 120max 120max 120max 120max 120max 120max 120max
-10-0
C
140max 140max 160max 160max 160max 160max 160max 160max 160max 160max
RIPPLE NOISE[mVp-p]
0to+50
C
120max 120max 150max 150max 150max 150max 150max 250max 250max 150max
-10-0
C
160max 160max 180max 180max 180max 180max 180max 280max 280max 180max
TEMPERATURE REGULATION[mV]
60max 60max 120max 150max 180max 200max 290max 290max 290max 360max
DRIFT[mV]
*2
20max 20max 36max 48max 60max 72max 96max 96max 96max 120max
START-UP TIME[ms] 200max (ACIN 100V,Io=100%)
HOLD-UP TIME[ms] 10typ (ACIN 85V,Io=100%)20typ (ACIN 100V,Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
2.85 - 3.6 Fixed ("Y"which can be adjusted the output is available as option :5,9,12,15,18,24,30V t10%)
OUTPUT VOLTAGE SETTING[V]
xx 4.9 - 5.3 8.6 - 9.4
11.5 - 12.5 14.4 - 15.6 17.3 - 18.7 23.0 - 25.0 23.0 - 25.0 23.0 - 25.0 28.5 - 31.5
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating (-H : peak)and recovers automatically
OVERVOLTAGE PROTECTION
4.00 - 5.25V
Works at 115 - 140% of rating
OPERATING INDICATION Not provided
REMOTE SENSING Not provided
REMOTE ON/OFF Option (Refer to Instruction Manual)
ISOLATION
INPUT-OUTPUT AC3,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-FG AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-10 to +60C,20 - 90%RH (Non condensing)(
Refer to DERATING CURVE)3,000m (10,000feet)max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C,20 - 90%RH (Non condensing)9,000m (30,000feet)max
VIBRATION 10 - 55Hz,19.6m/s2(2G), 3minutes period,60minutes each along X,Y and Z axis
IMPACT 196.1m/s2(20G), 11ms,once each X,Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS UL60950-1,EN60950-1,EN50178,CSA C22.2 No.60950-1 Complies with DEN-AN and IEC60950-1
CONDUCTED NOISE Complies with FCC-B,CISPR22-B,EN55022-B,VCCI-B
OTHERS CASE SIZE/WEIGHT 55X26X195mm (WXHXD)/250g max (without chassis and cover)
COOLING METHOD Convection
*1Peak load for 10sec. or less is acceptable if the total wattage is less than the rated
wattage(24V:50.4W).
*2Drift is the change in DC output for an eight hour period after a half-hour warm-up at
25C,with the input voltage held constant at the rated input/output.
*3( ) : peak current
*4Please contact us about safety approvals for the model with option.
*Avoid prolonged use under over-load.
*Parallel operation with other model is not possible.
*Derating is required when operated with chassis and cover.
LDA50F
AC-DC Power Supplies Open Frame/Enclosed type
LDA 50 F -5 -O
Ordering information
1Series name
2Output wattage
3Universal input
4Output voltage
5Optional *4
C :with Coating
G :Low leakage current
R :with Remote ON/OFF
S :with Chassis
SN
:with Chassis & cover
Y :with Potentiometer
R
12345
LDA
LDA-8
Recommended EMI/EMC Filter
NAC-06-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended
*to connect with several devices.
¡OVERCURRENT CHARACTERISTICS (LDA50F-5)
¡STATIC CHARACTERISTICS (LDA50F-5)¡RISE TIME & FALL TIME (LDA50F-5)
¡DERATING CURVE
LDA
LDA-9
LDA50F
External view
Performance data
MODEL
LDA75F-3 LDA75F-5 LDA75F-9
LDA75F-12 LDA75F-15 LDA75F-18 LDA75F-24
LDA75F-24-H
LDA75F-24-HR
LDA75F-30
MAX OUTPUT WATTAGE[W] 45 75 76.5 75.6 75 75.6 76.8 76.8 76.8 75
DC OUTPUT
*3
3V 15A 5V 15A 9V 8.5A 12V 6.3A 15V 5A 18V 4.2A 24V 3.2A
24V 3.2(4.5)A 24V 3.2(4.5)A
30V 2.5A
SPECIFICATIONS
MODEL
LDA75F-3 LDA75F-5 LDA75F-9
LDA75F-12 LDA75F-15 LDA75F-18 LDA75F-24
LDA75F-24-H
LDA75F-24-HR
LDA75F-30
INPUT
VOLTAGE[V] AC85 - 264 1for DC110 - 370
CURRENT[A]
ACIN 100V
1.8typ (Io=100%)
ACIN 200V
1.0typ (Io=100%)
FREQUENCY[Hz] 47 - 440
EFFICIENCY[%] 73typ 79typ 79typ 80typ 81typ 81typ 82typ 82typ 82typ 82typ
INRUSH CURRENT[A]
ACIN 200V
30typ (Io=100%)(
At cold start)
LEAKAGE CURRENT[mA] 0.75max (60Hz,According to UL,CSA,VDE and DEN-AN)
OUTPUT
VOLTAGE[V] 35912151824242430
CURRENT[A]
*1
15 15 8.5 6.3 5 4.2 3.2 3.2 (4.5)3.2 (4.5)2.5
LINE REGULATION[mV] 20max 20max 36max 48max 60max 72max 96max 96max 96max 120max
LOAD REGULATION[mV] 40max 40max 100max 100max 120max 120max 150max 150max 150max 180max
RIPPLE[mVp-p]
0to+50
C
80max 80max 120max 120max 120max 120max 120max 120max 120max 120max
-10-0
C
140max 140max 160max 160max 160max 160max 160max 160max 160max 160max
RIPPLE NOISE[mVp-p]
0to+50
C
120max 120max 150max 150max 150max 150max 150max 250max 250max 150max
-10-0
C
160max 160max 180max 180max 180max 180max 180max 280max 280max 180max
TEMPERATURE REGULATION[mV]
60max 60max 120max 150max 180max 200max 290max 290max 290max 360max
DRIFT[mV]
*2
20max 20max 36max 48max 60max 72max 96max 96max 96max 120max
START-UP TIME[ms] 200max (ACIN 100V,Io=100%)
HOLD-UP TIME[ms] 10typ (ACIN 85V,Io=100%)20typ (ACIN 100V,Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
2.85 - 3.6 Fixed ("Y"which can be adjusted the output is available as option : 5,9,12,15,18,24,30V t10%)
OUTPUT VOLTAGE SETTING[V]
xx 4.9 - 5.3 8.6 - 9.4
11.5 - 12.5 14.4 - 15.6 17.3 - 18.7 23.0 - 25.0 23.0 - 25.0 23.0 - 25.0 28.5 - 31.5
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating (-H : peak)and recovers automatically
OVERVOLTAGE PROTECTION
4.00 - 5.25V
Works at 115 - 140% of rating
OPERATING INDICATION Not provided
REMOTE SENSING Not provided
REMOTE ON/OFF Option (Refer to Instruction Manual)
ISOLATION
INPUT-OUTPUT AC3,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-FG AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-10 to +60C,20 - 90%RH (Non condensing)(
Refer to DERATING CURVE)3,000m (10,000feet)max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C,20 - 90%RH (Non condensing)9,000m (30,000feet)max
VIBRATION 10 - 55Hz,19.6m/s2(2G), 3minutes period,60minutes each along X,Y and Z axis
IMPACT 196.1m/s2(20G), 11ms,once each X,Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS UL60950-1,EN60950-1,EN50178,CSA C22.2 No.60950-1 Complies with DEN-AN and IEC60950-1
CONDUCTED NOISE Complies with FCC-B,CISPR22-B,EN55022-B,VCCI-B
OTHERS CASE SIZE/WEIGHT 55X32X222mm (WXHXD)/320g max (without chassis and cover)
COOLING METHOD Convection
*1Peak load for 10sec. or less is acceptable if the total wattage is less than the rated
wattage(24V:76.8W).
*2Drift is the change in DC output for an eight hour period after a half-hour warm-up at
25C,with the input voltage held constant at the rated input/output.
*3( ) : peak current
*4Please contact us about safety approvals for the model with option.
*Avoid prolonged use under over-load.
*Parallel operation with other model is not possible.
*Derating is required when operated with chassis and cover.
LDA75F
AC-DC Power Supplies Open Frame/Enclosed type
LDA 75 F -5 -O
Ordering information
1Series name
2Output wattage
3Universal input
4Output voltage
5Optional *4
C :with Coating
G :Low leakage current
L :with LED
R :with Remote ON/OFF
S :with Chassis
SN
:with Chassis & cover
Y :with Potentiometer
R
12345
LDA
LDA-10
Recommended EMI/EMC Filter
NAC-06-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended
*to connect with several devices.
¡OVERCURRENT CHARACTERISTICS (LDA75F-5)
¡STATIC CHARACTERISTICS (LDA75F-5)¡RISE TIME & FALL TIME (LDA75F-5)
¡DERATING CURVE
LDA
LDA-11
LDA75F
External view
B6P-VH
Performance data
MODEL
LDA100W-3 LDA100W-5 LDA100W-9
LDA100W-12 LDA100W-15 LDA100W-18 LDA100W-24
LDA100W-24-H
LDA100W-30 LDA100W-48
MAX OUTPUT WATTAGE[W] 60 100 103.5 102 100.5 100.8 103.2 103.2 105 96
DC OUTPUT
*3
3V 20A 5V 20A 9V 11.5A 12V 8.5A 15V 6.7A 18V 5.6A 24V 4.3A
24V 4.3(6.5)A
30V 3.5A 48V 2.0A
SPECIFICATIONS
MODEL
LDA100W-3 LDA100W-5 LDA100W-9
LDA100W-12 LDA100W-15 LDA100W-18 LDA100W-24
LDA100W-24-H
LDA100W-30 LDA100W-48
INPUT
VOLTAGE[V] AC 85 - 132 / 170 - 264 1f
CURRENT[A]
ACIN 100V
2.4typ (Io=100%)
ACIN 200V
1.2typ (Io=100%)
FREQUENCY[Hz] 47 - 440
EFFICIENCY[%] 75typ 79typ 80typ 81typ 82typ 82typ 83typ 83typ 83typ 82typ
INRUSH CURRENT[A]
ACIN 200V
30typ (Io=100%)(
At cold start)
LEAKAGE CURRENT[mA] 0.75max (60Hz,According to UL,CSA,VDE and DEN-AN)
OUTPUT
VOLTAGE[V] 35912151824243048
CURRENT[A]
*1
20 20 11.5 8.5 6.7 5.6 4.3 4.3 (6.5)3.5 2.0
LINE REGULATION[mV] 20max 20max 36max 48max 60max 72max 96max 96max 120max 192max
LOAD REGULATION[mV] 40max 40max 100max 100max 120max 120max 150max 150max 180max 240max
RIPPLE[mVp-p]
0to+50
C
80max 80max 120max 120max 120max 120max 120max 120max 120max 150max
-10-0
C
140max 140max 160max 160max 160max 160max 160max 160max 160max 200max
RIPPLE NOISE[mVp-p]
0to+50
C
120max 120max 150max 150max 150max 150max 150max 250max 150max 400max
-10-0
C
160max 160max 180max 180max 180max 180max 180max 280max 180max 600max
TEMPERATURE REGULATION[mV]
60max 60max 120max 150max 180max 200max 290max 290max 360max 560max
DRIFT[mV]
*2
20max 20max 36max 48max 60max 72max 96max 96max 120max 192max
START-UP TIME[ms] 200max (ACIN 100V,Io=100%)
HOLD-UP TIME[ms] 10typ (ACIN 85V,Io=100%)20typ (ACIN 100V,Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
2.85 - 3.6 4.5 - 5.5
Fixed ("Y"which can be adjusted the output is available as option :9,12,15,18,24,30,48V t10%)
OUTPUT VOLTAGE SETTING[V]
xx xx 8.6 - 9.4
11.5 - 12.5 14.4 - 15.6 17.3 - 18.7 23.0 - 25.0 23.0 - 25.0 28.8 - 31.2 46.0 - 50.0
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating (-H : peak)and recovers automatically
OVERVOLTAGE PROTECTION
4.00 - 5.25V
Works at 115 - 140% of rating
OPERATING INDICATION Not provided
REMOTE SENSING Not provided
REMOTE ON/OFF Option (Refer to Instruction Manual)
ISOLATION
INPUT-OUTPUT AC3,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-FG AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-10 to +60C,20 - 90%RH (Non condensing)(
Refer to DERATING CURVE)3,000m (10,000feet)max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C,20 - 90%RH (Non condensing)9,000m (30,000feet)max
VIBRATION 10 - 55Hz,19.6m/s2(2G), 3minutes period,60minutes each along X,Y and Z axis
IMPACT 196.1m/s2(20G), 11ms,once each X,Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS UL60950-1,EN60950-1,EN50178,CSA C22.2 No.234 Complies with DEN-AN and IEC60950-1
CONDUCTED NOISE Complies with FCC-B,CISPR22-B,EN55022-B,VCCI-B
OTHERS CASE SIZE/WEIGHT 62X35X222mm (WXHXD)/360g max (without chassis and cover)
COOLING METHOD Convection
*1Peak load for 20sec. or less is acceptable if the total wattage is less than the rated
wattage(24V:103.2W).
*2Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C,
with the input voltage held constant at the rated input/output.
*3( ) : peak current
*4Please contact us about safety approvals for the model with option.
*Avoid prolonged use under over-load.
*Parallel operation with other model is not possible.
*Derating is required when operated with chassis and cover.
LDA100W
AC-DC Power Supplies Open Frame/Enclosed type
LDA 100 W -5 -O
Ordering information
1Series name
2Output wattage
3Autoranging input
4Output voltage
5Optional *4
C :with Coating
G :Low leakage current
R :with Remote ON/OFF
S :with Chassis
SN
:with Chassis & cover
Y :with Potentiometer
R
12345
LDA
LDA-12
Recommended EMI/EMC Filter
NAC-06-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended
*to connect with several devices.
¡OVERCURRENT CHARACTERISTICS (LDA100W-5)
¡STATIC CHARACTERISTICS (LDA100W-5)¡RISE TIME & FALL TIME (LDA100W-5)
¡DERATING CURVE
Convection
Forced Air(0.5m3/min)
AMBIENT TEMPARATURE
C
LOAD FACTOR
%
100
80
60
40
20
0-10 10 20 30 40 50 60 70
LDA
LDA-13
LDA100W
External view
Performance data
MODEL
LDA150W-3 LDA150W-5 LDA150W-9
LDA150W-12 LDA150W-15 LDA150W-18 LDA150W-24
LDA150W-24-H
LDA150W-30 LDA150W-48
MAX OUTPUT WATTAGE[W] 90 150 153 150 150 153 151.2 151.2 150 144
DC OUTPUT
*3
3V 30A 5V 30A 9V 17A
12V 12.5A
15V 10A 18V 8.5A 24V 6.3A
24V 6.3(10)A
30V 5A 48V 3A
SPECIFICATIONS
MODEL
LDA150W-3 LDA150W-5 LDA150W-9
LDA150W-12 LDA150W-15 LDA150W-18 LDA150W-24
LDA150W-24-H
LDA150W-30 LDA150W-48
INPUT
VOLTAGE[V] AC 85 - 132 / 170 - 264 1f
CURRENT[A]
ACIN 100V
3.6typ (Io=100%)
ACIN 200V
2.0typ (Io=100%)
FREQUENCY[Hz] 47 - 440
EFFICIENCY[%] 75typ 79typ 79typ 82typ 83typ 84typ 85typ 85typ 85typ 82typ
INRUSH CURRENT[A]
ACIN 200V
30typ (Io=100%)(
At cold start)
LEAKAGE CURRENT[mA] 0.75max (60Hz,According to UL,CSA,VDE and DEN-AN)
OUTPUT
VOLTAGE[V] 35912151824243048
CURRENT[A]
*1
30 30 17 12.5 10 8.5 6.3 6.3(10)53
LINE REGULATION[mV] 20max 20max 36max 48max 60max 72max 96max 96max 120max 192max
LOAD REGULATION[mV] 40max 40max 100max 100max 120max 120max 150max 150max 180max 240max
RIPPLE[mVp-p]
0to+50
C
80max 80max 120max 120max 120max 120max 120max 220max 120max 150max
-10-0
C
140max 140max 160max 160max 160max 160max 160max 260max 160max 200max
RIPPLE NOISE[mVp-p]
0to+50
C
120max 120max 150max 150max 150max 150max 150max 250max 150max 400max
-10-0
C
160max 160max 180max 180max 180max 180max 180max 280max 180max 600max
TEMPERATURE REGULATION[mV]
60max 60max 120max 150max 180max 200max 290max 290max 360max 560max
DRIFT[mV]
*2
20max 20max 36max 48max 60max 72max 96max 96max 120max 192max
START-UP TIME[ms] 200max (ACIN 100V,Io=100%)
HOLD-UP TIME[ms] 10typ (ACIN 85V,Io=100%)20typ (ACIN 100V,Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
2.85 - 3.6 4.5 - 5.5
Fixed ("Y"which can be adjusted the output is available as option :9,12,15,18,24,30,48V t10%)
OUTPUT VOLTAGE SETTING[V]
xx xx 8.6 - 9.4
11.5 - 12.5 14.4 - 15.6 17.3 - 18.7 23.0 - 25.0 23.0 - 25.0 28.5 - 31.5 46.0 - 50.0
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating (-H : peak)and recovers automatically
OVERVOLTAGE PROTECTION
4.00 - 5.25V
Works at 115 - 140% of rating
OPERATING INDICATION Not provided
REMOTE SENSING Not provided
REMOTE ON/OFF Option (Refer to Instruction Manual)
ISOLATION
INPUT-OUTPUT AC3,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-FG AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-10 to +60C,20 - 90%RH (Non condensing)(
Refer to DERATING CURVE)3,000m (10,000feet)max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C,20 - 90%RH (Non condensing)9,000m (30,000feet)max
VIBRATION 10 - 55Hz,19.6m/s2(2G), 3minutes period,60minutes each along X,Y and Z axis
IMPACT 196.1m/s2(20G), 11ms,once each X,Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS UL60950-1,EN60950-1,EN50178,CSA C22.2 No.234 Complies with DEN-AN and IEC60950-1
CONDUCTED NOISE Complies with FCC-B,CISPR22-B,EN55022-B,VCCI-B
OTHERS CASE SIZE/WEIGHT 75X37X222mm (WXHXD)/510g max (without chassis and cover)
COOLING METHOD Convection
*1Peak load for 10sec. or less is acceptable if the total wattage is less than the rated
wattage(24V:151.2W).
*2Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C,
with the input voltage held constant at the rated input/output.
*3( ) : peak current
*4Please contact us about safety approvals for the model with option.
*Avoid prolonged use under over-load.
*Parallel operation with other model is not possible.
*Derating is required when operated with chassis and cover.
LDA150W
AC-DC Power Supplies Open Frame/Enclosed type
LDA 150 W -5 -O
Ordering information
1Series name
2Output wattage
3Autoranging input
4Output voltage
5Optional *4
C :with Coating
G :Low leakage current
L :with LED
R :with Remote ON/OFF
S :with Chassis
SN
:with Chassis & cover
Y :with Potentiometer
R
12345
LDA
LDA-14
Recommended EMI/EMC Filter
NAC-06-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended
*to connect with several devices.
¡OVERCURRENT CHARACTERISTICS (LDA150W-5)
¡STATIC CHARACTERISTICS (LDA150W-5)¡RISE TIME & FALL TIME (LDA150W-5)
¡DERATING CURVE
LDA
LDA-15
LDA150W
External view
Performance data
MODEL
LDA300W-3 LDA300W-5 LDA300W-9
LDA300W-12 LDA300W-15 LDA300W-18 LDA300W-24 LDA300W-30 LDA300W-48
MAX OUTPUT WATTAGE[W] 180 300 306 324 330 306 336 300 302.4
DC OUTPUT 3V 60A 5V 60A 9V 34A 12V 27A 15V 22A 18V 17A 24V 14A 30V 10A 48V 6.3A
SPECIFICATIONS
MODEL
LDA300W-3 LDA300W-5 LDA300W-9
LDA300W-12 LDA300W-15 LDA300W-18 LDA300W-24 LDA300W-30 LDA300W-48
INPUT
VOLTAGE[V] AC 85 - 132 / 170 - 264 1f
CURRENT[A]
ACIN 100V
7.5typ (Io=100%)
ACIN 200V
4.5typ (Io=100%)
FREQUENCY[Hz] 47 - 440
EFFICIENCY[%]
ACIN 100V
72typ 78typ 78typ 80typ 81typ 81typ 83typ 83typ 83typ
ACIN 200V
74typ 81typ 81typ 83typ 84typ 84typ 86typ 86typ 86typ
INRUSH CURRENT[A]
ACIN 100V
15/30A typ (Primary/Secondary Surge Current)Io=100% (More than 3sec.to re-start)
ACIN 200V
30/30typ (Primary/Secondary Surge Current)Io=100% (More than 3sec.to re-start)
LEAKAGE CURRENT[mA] 0.75max (60Hz,According to UL,CSA,VDE and DEN-AN)
OUTPUT
VOLTAGE[V] 359121518243048
CURRENT[A]
Forced air
60 60 34 27 22 17 14 10 6.3
Convection
*1
40 (60)40 (60)23 (34)17 (27)14 (22)12 (17)9(14)7(10)4.2 (6.3)
LINE REGULATION[mV] 20max 20max 36max 48max 60max 72max 96max 120max 192max
LOAD REGULATION[mV] 40max 40max 100max 100max 120max 120max 150max 180max 240max
RIPPLE[mVp-p]
0to+50
C
*2
80max 80max 120max 120max 120max 120max 120max 120max 150max
-10-0
C
*2
140max 140max 160max 160max 160max 160max 160max 160max 200max
RIPPLE NOISE[mVp-p]
0to+50
C
*2
120max 120max 150max 150max 150max 150max 150max 150max 400max
-10-0
C
*2
160max 160max 180max 180max 180max 180max 180max 180max 600max
TEMPERATURE REGULATION[mV]
60max 60max 120max 150max 180max 200max 290max 360max 560max
DRIFT[mV]
*3
20max 20max 36max 48max 60max 72max 96max 120max 192max
START-UP TIME[ms] 200max (ACIN 100V,Io=100%)
HOLD-UP TIME[ms] 10typ (ACIN 85V,Io=100%)20typ (ACIN 100V,Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
2.85 - 3.6 5,9,12,15,18,24,30,48V t10%
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION
4.00 - 5.25V
Works at 115 - 140% of rating
OPERATING INDICATION Not provided
REMOTE SENSING Provided
REMOTE ON/OFF Option (Refer to Instruction Manual)
ISOLATION
INPUT-OUTPUT AC3,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-FG AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-10 to +70C,20 - 90%RH (Non condensing)(
Refer to DERATING CURVE)3,000m (10,000feet)max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C,20 - 90%RH (Non condensing)9,000m (30,000feet)max
VIBRATION 10 - 55Hz,19.6m/s2(2G), 3minutes period,60minutes each along X,Y and Z axis
IMPACT 196.1m/s2(20G), 11ms,once each X,Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS UL60950-1,C-UL,EN60950-1,EN50178 Complies with DEN-AN and IEC60950-1
CONDUCTED NOISE Complies with FCC-B,CISPR22-B,EN55022-B,VCCI-B
OTHERS CASE SIZE/WEIGHT 108X50X255mm (WXHXD)/1kg max (without terminal block)
COOLING METHOD Convection / Forced air (Refer to DERATING CURVE)
*1Peak load for 30sec. or less is acceptable if the total wattage is less than the rated wattage.
*2This is the value that measured on measuring board with capacitor of 22mF within 150mm from output terminal.
*3Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
*4Please contact us about safety approvals for the model with option.
*Parallel operation with other model is not possible.
*Derating is required when operated with chassis and cover.
LDA300W
AC-DC Power Supplies Open Frame/Enclosed type
LDA 300 W -5 -O
Ordering information
1Series name
2Output wattage
3Autoranging input
4Output voltage
5Optional *4
C :with Coating
G :Low leakage current
L :with LED
R :with Remote ON/OFF
S :with Chassis
SNF
:with Chassis & cover
& fan
T :Vertical terminal block
R
12345
LDA
LDA-16
Recommended EMI/EMC Filter
NAC-16-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended
*to connect with several devices.
¡OVERCURRENT CHARACTERISTICS (LDA300W-5)
¡STATIC CHARACTERISTICS (LDA300W-5) ¡RISE TIME & FALL TIME (LDA300W-5)
¡DERATING CURVE
LDA
LDA-17
LDA300W
External view
Applicable options
Terminal Block Horizontal type
Terminal Block Vertical type
-S
-SN
-SNF
Available
Not Available
Available
5V, 12V, 24V
Available
Not Available
Not Available
-ST
-SNT
-SNFT
CN1(Connector for Sensing)
Type: B4B-XH-A
Mating Housing & Pin
Mfr: J.S.T.
XHP
-
4
(BXH
-
001T
-
P0.6 or SXH
-
001T
-
P0.6)
Pin No.
1
2
3
4
-M
-S(Remote Sensing)
+S(Remote Sensing)
+M
Function
CN2(Optional connector for Remote ON/OFF: optional)
Type: B2B-XH-A
Mating Housing & Pin
Mfr: J.S.T.
XHP
-
2
(BXH
-
001T
-
P0.6 or SXH
-
001T
-
P0.6)
Pin No.
1
2
RC(+)
RC(-)
Function
Performance data