PD-94457C AFL50XXS SERIES 50V Input, Single Output HYBRID-HIGH RELIABILITY DC-DC CONVERTER Description The AFL Series of DC-DC converters feature high power density with no derating over the full military temperature range. This series is offered as part of a complete family of converters providing single and dual output voltages and operating from nominal +28V, +50V, +120V or +270V inputs with output power ranging from 80W to 120W. For applications requiring higher output power, individual converters can be operated in parallel. The internal current sharing circuits assure equal current distribution among the paralleled converters. This series incorporates International Rectifier's proprietary magnetic pulse feedback technology providing optimum dynamic line and load regulation response. This feedback system samples the output voltage at the pulse width modulator fixed clock frequency, nominally 550KHz. Multiple converters can be synchronized to a system clock in the 500KHz to 700 KHz range or to the synchronization output of one converter. Undervoltage lockout, primary and secondary referenced inhibit, soft-start and load fault protection are provided on all models. These converters are hermetically packaged in two enclosure variations, utilizing copper core pins to minimize resistive DC losses. Three lead styles are available, each fabricated with International Rectifier's rugged ceramic lead-to-package seal assuring long term hermeticity in the most harsh environments. AFL Features n n n n n n n n n n n n n n n n n 30V To 80V Input Range 5V, 8V, 9V, 12V, 15V and 28V Outputs Available High Power Density - up to 84 W/in3 Up To 120W Output Power Parallel Operation with Stress and Current Sharing Low Profile (0.380") Seam Welded Package Ceramic Feedthru Copper Core Pins High Efficiency - to 85% Full Military Temperature Range Continuous Short Circuit and Overload Protection Remote Sensing Terminals Primary and Secondary Referenced Inhibit Functions Line Rejection > 40dB - DC to 50KHz External Synchronization Port Fault Tolerant Design Dual Output Versions Available Standard Microcircuit Drawings Available Manufactured in a facility fully qualified to MIL-PRF38534, these converters are fabricated utilizing DSCC qualified processes. For available screening options, refer to device screening table in the data sheet. Variations in electrical, mechanical and screening can be accommodated. Contact IR San Jose for special requirements. www.irf.com 1 01/04/10 AFL50XXS Series Specifications Absolute Maximum Ratings Input voltage Soldering temperature Operating case temperature Storage case temperature -0.5V to +100VDC 300C for 10 seconds -55C to +125C -65C to +135C Static Characteristics -55C < TCASE < +125C, 30V< VIN < 80V unless otherwise specified. Group A Subgroups Parameter Test Conditions INPUT VOLTAGE Note 6 OUTPUT VOLTAGE V IN = 50 Volts, 100% Load AFL5005S AFL5008S AFL5009S AFL5012S AFL5015S AFL5028S 1 1 1 1 1 1 AFL5005S AFL5008S AFL5009S AFL5012S AFL5015S AFL5028S 2, 2, 2, 2, 2, 2, 3 3 3 3 3 3 Min Nom Max Unit 30 50 80 V 4.95 7.92 8.91 11.88 14.85 27.72 5.00 8.00 9.00 12.00 15.00 28.00 5.05 8.08 9.09 12.12 15.15 28.28 V 4.90 7.84 8.82 11.76 14.70 27.44 V IN = 30, 50, 80 Volts - Note 6 OUTPUT CURRENT AFL5005S AFL5008S AFL5009S AFL5012S AFL5015S AFL5028S 5.10 8.16 9.18 12.24 15.30 28.56 16.0 10.0 10.0 9.0 8.0 4.0 A Note 6 OUTPUT POWER 80 80 90 108 120 112 AFL5005S AFL5008S AFL5009S AFL5012S AFL5015S AFL5028S W F MAXIMUM CAPACITIVE LOAD Note 1 10,000 OUTPUT VOLTAGE TEMPERATURE COEFFICIENT V IN = 50 Volts, 100% Load - Note 1, 6 -0.015 +0.015 %/C No Load, 50% Load, 100% Load V IN = 30, 50, 80 Volts -70.0 -20.0 +70.0 +20.0 mV mV -1.0 +1.0 % OUTPUT VOLTAGE REGULATION AFL5028S Line All Others Line Load OUTPUT RIPPLE VOLTAGE AFL5005S AFL5008S AFL5009S AFL5012S AFL5015S AFL5028S 1, 2, 3 1, 2, 3 1, 2, 3 1, 1, 1, 1, 1, 1, 2, 2, 2, 2, 2, 2, 3 3 3 3 3 3 V IN = 30, 50, 80 Volts, 100% Load, BW = 10MHz 30 40 40 45 50 100 mV pp For Notes to Specifications, refer to page 4 2 www.irf.com AFL50XXS Series Static Characteristics (Continued) Parameter Group A Subgroups INPUT CURRENT No Load No Load Inhibit 1 Inhibit 2 INPUT RIPPLE CURRENT AFL5005S AFL5008S AFL5009S AFL5012S AFL5015S AFL5028S CURRENT LIMIT POINT As a percentage of full rated load LOAD FAULT POWER DISSIPATION Overload or Short Circuit EFFICIENCY AFL5005S AFL5008S AFL5009S AFL5012S AFL5015S AFL5028S ENABLE INPUTS (Inhibit Function) Converter Off Sink Current Converter On Sink Current SWITCHING FREQUENCY SYNCHRONIZATION INPUT Frequency Range Pulse Amplitude, Hi Pulse Amplitude, Lo Pulse Rise Time Pulse Duty Cycle ISOLATION 1 2, 3 1 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1 2 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 Test Conditions Min VIN = 50 Volts IOUT = 0 (All models except AFL5015S) IOUT = 0 (AFL5015S) Pin 4 Shorted to Pin 2 Pin 12 Shorted to Pin 8 VIN = 50 Volts, 100% Load, BW = 10MHz VOUT = 90% VNOM , VIN = 50 Volts Note 5 60 60 60 60 60 60 115 105 125 VIN = 50 Volts VIN = 50 Volts, 100% Load Logical Low on Pin 4 or Pin 12 Note 1 Logical High on Pin 4 and Pin 12 - Note 9 Note 1 78 79 80 81 82 82 2.0 1, 2, 3 1, 2, 3 1, 2, 3 500 2.0 -0.5 Input to Output or Any Pin to Case (except Pin 3). Test @ 500VDC DEVICE WEIGHT Slight Variations with Case Style MTBF MIL-HDBK-217F, AIF @ TC = 40C 550 20 100 mA mApp % 32 W % 0.8 100 50 100 V A V A 600 KHz 700 10 0.8 100 80 KHz V V ns % M 85 300 Unit 125 115 140 81 82 83 84 85 84 -0.5 500 Note 1 Note 1 Max 50 60 60 65 5.0 5.0 1, 2, 3 1 Nom g KHrs For Notes to Specifications, refer to page 4 www.irf.com 3 AFL50XXS Series Dynamic Characteristics -55C < TCASE < +125C, VIN=50V unless otherwise specified. Parameter Group A Subgroups AFL5008S AFL5009S AFL5012S AFL5015S AFL5028S Min Nom Max Unit Note 2, 8 LOAD TRANSIENT RESPONSE AFL5005S Test Conditions Amplitude Recovery 4, 5, 6 4, 5, 6 Load Step 50% 100% -450 450 200 mV s Amplitude Recovery 4, 5, 6 4, 5, 6 Load Step 10% 50% -450 450 300 mV s Amplitude Recovery 4, 5, 6 4, 5, 6 Load Step 50% 100% -500 500 200 mV s Amplitude Recovery 4, 5, 6 4, 5, 6 Load Step 10% 50% -500 500 300 mV s Amplitude Recovery 4, 5, 6 4, 5, 6 Load Step 50% 100% -600 600 200 mV s Amplitude Recovery 4, 5, 6 4, 5, 6 Load Step 10% 50% -600 600 300 mV s Amplitude Recovery 4, 5, 6 4, 5, 6 Load Step 50% 100% -750 750 200 mV s Amplitude Recovery 4, 5, 6 4, 5, 6 Load Step 10% 50% -750 750 300 mV s Amplitude Recovery 4, 5, 6 4, 5, 6 Load Step 50% 100% -750 750 200 mV s Amplitude Recovery 4, 5, 6 4, 5, 6 Load Step 10% 50% -750 750 300 mV s Amplitude Recovery 4, 5, 6 4, 5, 6 Load Step 50% 100% -1200 1200 200 mV s Amplitude Recovery 4, 5, 6 4, 5, 6 Load Step 10% 50% -1200 1200 300 mV s -500 500 500 mV s 250 120 mV ms Note 1, 2, 3 LINE TRANSIENT RESPONSE VIN Step = 30 80 Volts Amplitude Recovery TURN-ON CHARACTERISTICS Overshoot Delay VIN = 30, 50, 80 Volts. Note 4 4, 5, 6 4, 5, 6 Enable 1, 2 on. (Pins 4, 12 high or open) LOAD FAULT RECOVERY Same as Turn On Characteristics. LINE REJECTION MIL-STD-461D, CS101, 30Hz to 50KHz Note 1 50 75 40 50 dB Notes to Specifications: 1. 2. Parameters not 100% tested but are guaranteed to the limits specified in the table. Recovery time is measured from the initiation of the transient to where VOUT has returned to within 1.0% of VOUT at 50% load. Line transient transition time 100s. Turn-on delay is measured with an input voltage rise time of between 100V and 500V per millisecond. Current limit point is that condition of excess load causing output voltage to drop to 90% of nominal. Parameter verified as part of another test. All electrical tests are performed with the remote sense leads connected to the output leads at the load. Load transient transition time 10s. Enable inputs internally pulled high. Nominal open circuit voltage 4.0V DC. 3. 4. 5. 6. 7. 8. 9. 4 www.irf.com AFL50XXS Series Block Diagram Figure I. AFL Single Output + Input 1 Input Filter Enable 1 4 Output Filter Primary Bias Supply 7 +Output 10 +Sense Current Sense Sync Output 5 Sync Input 6 Case Control FB 3 Error Amp & Ref Share Amplifier 11 Share 12 Enable 2 Sense Amplifier Input Return 2 Circuit Operation and Application Information The AFL series of converters employ a forward switched mode converter topology. (refer to Figure I.) Operation of the device is initiated when a DC voltage whose magnitude is within the specified input limits is applied between pins 1 and 2. If pin 4 is enabled (at a logical 1 or open) the primary bias supply will begin generating a regulated housekeeping voltage bringing the circuitry on the primary side of the converter to life. A power MOSFET is used to chop the DC input voltage into a high frequency square wave, applying this chopped voltage to the power transformer at the nominal converter switching frequency. Maintaining a DC voltage within the specified operating range at the input assures continuous generation of the primary bias voltage. The switched voltage impressed on the secondary output transformer winding is rectified and filtered to generate the converter DC output voltage. An error amplifier on the secondary side compares the output voltage to a precision reference and generates an error signal proportional to the difference. This error signal is magnetically coupled through the feedback transformer into the controller section of the converter varying the pulse width of the square wave signal driving the MOSFET, narrowing the width if the output voltage is too high and widening it if it is too low, thereby regulating the output voltage. www.irf.com Return Sense 8 Output Return of application. When the remote sensing feature is not used, the sense lead should be connected to their respective output terminals at the converter. Figure III. illustrates a typical remotely sensed application. Inhibiting Converter Output (Enable) As an alternative to application and removal of the DC voltage to the input, the user can control the converter output by providing TTL compatible, positive logic signals to either of two enable pins (pin 4 or 12). The distinction between these two signal ports is that enable 1 (pin 4) is referenced to the input return (pin 2) while enable 2 (pin 12) is referenced to the output return (pin 8). Thus, the user has access to an inhibit function on either side of the isolation barrier. Each port is internally pulled "high" so that when not used, an open connection on both enable pins permits normal converter operation. When their use is desired, a logical "low" on either port will shut the converter down. Figure II. Enable Input Equivalent Circuit +5.6 V Pin 4 or Pin 12 1N4148 100K 290K Remote Sensing Connection of the + and - sense leads at a remotely located load permits compensation for excessive resistance between the converter output and the load when their physical separation could cause undesirable voltage drop. This connection allows regulation to the placard voltage at 9 Disable 2N3904 180K Pin 2 or Pin 8 5 AFL50XXS Series Internally, these ports differ slightly in their function. In use, a low on Enable 1 completely shuts down all circuits in the converter, while a low on Enable 2 shuts down the secondary side while altering the controller duty cycle to near zero. Externally, the use of either port is transparent to the user save for minor differences in idle current. (See specification table). Synchronization of Multiple Converters When operating multiple converters, system requirements often dictate operation of the converters at a common frequency. To accommodate this requirement, the AFL series converters provide both a synchronization input and output. The sync input port permits synchronization of an AFL converter to any compatible external frequency source oper- ating between 500KHz and 700KHz. This input signal should be referenced to the input return and have a 10% to 90% duty cycle. Compatibility requires transition times less than 100ns, maximum low level of +0.8V and a minimum high level of +2.0V. The sync output of another converter which has been designated as the master oscillator provides a convenient frequency source for this mode of operation. When external synchronization is not required, the sync in pin should be left open (unconnected )thereby permitting the converter to operate at its' own internally set frequency. The sync output signal is a continuous pulse train set at 550 50KHz, with a duty cycle of 15 5.0%. This signal is referenced to the input return and has been tailored to be compatible with the AFL sync input port. Transition times are less than 100ns and the low level output impedance is less than 50. This signal is active when the DC input voltage is within the specified operating range and the converter is not inhibited. This output has adequate drive reserve to synchronize at least five additional converters. A typical connection is illustrated in Figure III. Figure III. Preferred Connection for Parallel Operation Power Input 1 Vin Enable 2 Rtn Share Case Enable 1 Optional Synchronization Connection AFL 12 + Sense - Sense Sync Out Return Sync In + Vout 6 7 1 12 Share Bus Enable 2 Vin Share Rtn Case Enable 1 AFL + Sense - Sense Sync Out Return Sync In + Vout 6 1 Vin Enable 2 Rtn Share Case Enable 1 AFL to Load 7 12 + Sense - Sense Sync Out Return Sync In + Vout 7 6 (Other Converters) Parallel Operation-Current and Stress Sharing Figure III. illustrates the preferred connection scheme for operation of a set of AFL converters with outputs operating in parallel. Use of this connection permits equal sharing among the members of a set whose load current exceeds the capacity of an individual AFL. An important feaure of the 6 AFL series operating in the parallel mode is that in addition to sharing the current, the stress induced by temperature will also be shared. Thus if one member of a paralleled set is operating at a higher case temperature, the current it provides to the load will be reduced as compensation for the temperature induced stress on that device. www.irf.com AFL50XXS Series When operating in the shared mode, it is important that symmetry of connection be maintained as an assurance of optimum load sharing performance. Thus, converter outputs should be connected to the load with equal lengths of wire of the same gauge and sense leads from each converter should be connected to a common physical point, preferably at the load along with the converter output and return leads. All converters in a paralleled set must have their share pins connected together. This arrangement is diagrammatically illustrated in Figure III. showing the outputs and return pins connected at a star point which is located close as possible to the load. As a consequence of the topology utilized in the current sharing circuit, the share pin may be used for other functions. In applications requiring only a single converter, the voltage appearing on the share pin may be used as a "current monitor". The share pin open circuit voltage is nominally +1.00V at no load and increases linearly with increasing output current to +2.20V at full load. Thermal Considerations Because of the incorporation of many innovative technological concepts, the AFL series of converters is capable of providing very high output power from a package of very small volume. These magnitudes of power density can only be obtained by combining high circuit efficiency with effective methods of heat removal from the die junctions. This requirement has been effectively addressed inside the device; but when operating at maximum loads, a significant amount of heat will be generated and this heat must be conducted away from the case. To maintain the case temperature at or below the specified maximum of 125C, this heat must be transferred by conduction to an appropriate heat dissipater held in intimate contact with the converter base-plate. Since the effectiveness of this heat transfer is dependent on the intimacy of the baseplate/heatsink interface, it is strongly recommended that a high thermal conductivity heat transferring medium is inserted between the baseplate and heatsink. The material most frequently utilized at the factory during all testing and burn-in processes is sold under the trade name of Sil-Pad(R) 4001 . This particular product is an insulator but electrically conductive versions are also available. Use of these materials assures maximum surface contact with the heat dissipater thereby compensating for any minor surface variations. While other available types of heat conductive materials and thermal compounds provide similar effectiveness, these alternatives are often less convenient and can be somewhat messy to use. A conservative aid to estimating the total heat sink surface area (AHEAT SINK) required to set the maximum case temperature rise (T) above ambient temperature is given by the following expression: . T -143 - 3.0 A HEAT SINK 80P 0.85 where T = Case temperature rise above ambient 1 - 1 P = Device dissipation in Watts = POUT Eff As an example, it is desired to maintain the case temperature of an AFL5015S at +85C while operating in an open area whose ambient temperature is held at a constant +25C; then T = 85 - 25 = 60C If the worst case full load efficiency for this device is 83%; then the power dissipation at full load is given by 1 P = 120 * - 1 = 120 * ( 0.205) = 24.6W .83 and the required heat sink area is . -143 60 A HEAT SINK = - 3.0 = 71 in 2 80 * 24.6 0.85 Thus, a total heat sink surface area (including fins, if any) of 71 in2 in this example, would limit case rise to 60C above ambient. A flat aluminum plate, 0.25" thick and of approximate dimension 4" by 9" (36 in 2 per side) would suffice for this application in a still air environment. Note that to meet the criteria in this example, both sides of the plate require unrestricted exposure to the ambient air. 1Sil-Pad is a registered Trade Mark of Bergquist, Minneapolis, MN www.irf.com 7 AFL50XXS Series Input Filter The AFL50XXS series converters incorporate a LC input filter whose elements dominate the input load impedance characteristic at turn-on. The input circuit is as shown in Figure IV. Figure IV. Input Filter Circuit Finding a resistor value for a particular output voltage, is simply a matter of substituting the desired output voltage and the nominal device voltage into the equation and solving for the corresponding resistor value. Figure V. Connection for VOUT Adjustment Enable 2 0.75H Share Pin 1 AFL50xxS 2.7fd Pin 2 + Sense R ADJ - Sense Return To Load + Vout Note: Radj must be set 500 Undervoltage Lockout A minimum voltage is required at the input of the converter to initiate operation. This voltage is set to 26.5 1.5V. To preclude the possibility of noise or other variations at the input falsely initiating and halting converter operation, a hysteresis of approximately 2.0V is incorporated in this circuit. Thus if the input voltage droops to 24.5 1.5V, the converter will shut down and remain inoperative until the input voltage returns to 25V. Output Voltage Adjust In addition to permitting close voltage regulation of remotely located loads, it is possible to utilize the converter sense pins to incrementally increase the output voltage over a limited range. The adjustments made possible by this method are intended as a means to "trim" the output to a voltage setting for some particular application, but are not intended to create an adjustable output converter. These output voltage setting variations are obtained by connecting an appropriate resistor value between the +sense and -sense pins while connecting the -sense pin to the output return pin as shown in Figure V. below. The range of adjustment and corresponding range of resistance values can be determined by use of the following equation. Attempts to adjust the output voltage to a value greater than 120% of nominal should be avoided because of the potential of exceeding internal component stress ratings and subsequent operation to failure. Under no circumstance should the external setting resistor be made less than 500W. By remaining within this specified range of values, completely safe operation fully within normal component derating limits is assured. Examination of the equation relating output voltage and resistor value reveals a special benefit of the circuit topology utilized for remote sensing of output voltage in the AFL50XXS series of converters. It is apparent that as the resistance increases, the output voltage approaches the nominal set value of the device. In fact the calculated limiting value of output voltage as the adjusting resistor becomes very large is 25mV above nominal device voltage. The consequence is that if the +sense connection is unintentionally broken, an AFL50XXS has a fail-safe output voltage of Vout + 25mV, where the 25mV is independent of the nominal output voltage. It can be further demonstrated that in the event of both the + and - sense connections being broken, the output will be limited to Vout + 440mV. This 440mV is also essentially constant independent of the nominal output voltage. VNOM Radj = 100 * VOUT - VNOM -.025 Where VNOM = device nominal output voltage, and VOUT = desired output voltage 8 www.irf.com AFL50XXS Series Table 1. Nominal Resistance of Cu Wire General Application Information The AFL50XXS series of converters are capable of providing large transient currents to user loads on demand. Because the nominal input voltage range in this series is relatively low, the resulting input current demands will be correspondingly large. It is important therefore, that the line impedance be kept very low to prevent steady state and transient input currents from degrading the supply voltage between the voltage source and the converter input. In applications requiring high static currents and large transients, it is recommended that the input leads be made of adequate size to minimize resistive losses, and that a good quality capacitor of approximately 100F be connected directly across the input terminals to assure an adequately low impedance at the input terminals. Table I relates nominal resistance values and selected wire sizes. Wire Size, AWG Resistance per ft 24 Ga 25.7 m 22 Ga 16.2 m 20 Ga 10.1 m 18 Ga 6.4 m 16 Ga 4.0 m 14 Ga 2.5 m 12 Ga 1.6 m Incorporation of a 100F capacitor at the input terminals is recommended as compensation for the dynamic effects of the parasitic resistance of the input cable reacting with the complex impedance of the converter input, and to provide an energy reservoir for transient input current requirements. Figure VI. Problems of Parasitic Resistance in input Leads (See text) Rp esource Rp Iin IRtn 100 fd Vin eRtn Rtn Case System Ground Enable 1 Sync Out Sync In www.irf.com 9 AFL50XXS Series Mechanical Outlines Case X Case W Pin Variation of Case Y 3.000 o 0.128 2.760 0.050 0.050 1 12 0.250 0.250 0.200 Typ Non-cum 6 7 1.260 1.500 1.000 Ref 1.000 Pin o 0.040 Pin o 0.040 0.220 2.500 0.220 2.800 2.975 max 0.525 0.238 max 0.42 0.380 Max 0.380 Max Case Y Case Z Pin Variation of Case Y 1.150 0.300 o 0.140 0.25 typ 0.050 0.050 1 12 0.250 0.250 1.000 Ref 6 1.750 1.000 Ref 0.200 Typ Non-cum 7 1.500 1.750 2.00 Pin o 0.040 0.375 Pin o 0.040 0.220 0.220 0.36 2.500 2.800 2.975 max 0.525 0.238 max 0.380 Max 0.380 Max Tolerances, unless otherwise specified: .XX .XXX = = 0.010 0.005 BERYLLIA WARNING: These converters are hermetically sealed; however they contain BeO substrates and should not be ground or subjected to any other operations including exposure to acids, which may produce Beryllium dust or fumes containing Beryllium 10 www.irf.com AFL50XXS Series Pin Designation Pin # Designation 1 + Input 2 Input Return 3 Case Ground 4 Enable 1 5 Sync Output 6 Sync Input 7 + Output 8 Output Return 9 Return Sense 10 + Sense 11 Share 12 Enable 2 Standard Microcircuit Drawing Equivalence Table Standard Microcircuit Drawing Number www.irf.com IR Standard Part Number 5962-02557 AFL5005S 5962-02558 AFL5008S 5962-02559 AFL5009S 5962-02560 AFL5012S 5962-02561 AFL5015S 5962-02562 AFL5028S 11 AFL50XXS Series Device Screening Requirement MIL-STD-883 Method ES d HB -20C to +85C -55C to +125C e -55C to +125C Temperature Range Element Evaluation No Suffix CH -55C to +125C MIL-PRF-38534 N/A N/A N/A Class H 2023 N/A N/A N/A N/A Internal Visual 2017 c Yes Yes Yes Temperature Cycle 1010 N/A Cond B Cond C Cond C Constant Acceleration 2001, Y1 Axis N/A 500 Gs 3000 Gs 3000 Gs PIND 2020 N/A N/A N/A N/A 48 hrs@hi temp Non-Destructive Bond Pull Burn-In 1015 N/A Final Electrical MIL-PRF-38534 25C ( Group A ) & Specification 25C d 160 hrs@125C 160 hrs@125C -55C, +25C, -55C, +25C, +125C +125C PDA MIL-PRF-38534 N/A N/A N/A 10% Seal, Fine and Gross 1014 Cond A Cond A, C Cond A, C Cond A, C Radiographic 2012 N/A External Visual 2009 c N/A N/A N/A Yes Yes Yes Notes: Best commercial practice Sample tests at low and high temperatures -55C to +105C for AHE, ATO, ATW Part Numbering AFL 50 05 S X /CH Model Screening Level Input Voltage No suffix, ES, HB, CH 28 = 28V 50 = 50V 120 = 120V 270 = 270V Case Style Output Voltage 05 07 09 15 (Please refer to Screening Table) W, X, Y, Z Output S = Single = 5V, 06 = 6V = 7V, 08 = 8V = 9V, 12 = 12V = 15V, 28 = 28V WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, Tel: (310) 252-7105 IR SAN JOSE: 2520Junction Avenue, San Jose, California 95134, Tel: (408) 434-5000 Visit us at www.irf.com for sales contact information. Data and specifications subject to change without notice. 01/2011 12 www.irf.com