(888) IPD-CONVerters
(888) 473-2668
www.ipdconverters.com
1
HBD060YGE-A
60
65
70
75
80
85
10 20 30 40 50 60 70 80 90 100
LOAD %
EFFICIENCY
%
EFF. (18V)
EFF. (24V)
EFF. (36V)
50
55
60
65
70
75
80
85
10 20 30 40 50 60 70 80 90 100
L OAD %
EFFICIENCY
%
HBD060ZGE-A
HBD040ZGE-A
HBD040ZED-A
HBD SERIES - DUAL OUTPUT, 60 WATT
Independent Trim
For Each Output
1500V Isolation
100°C Baseplate
Operation
TECHNICAL SPECIFICATIONS
Voltage Range
24 VDC Nominal 18.00 - 36.00 VDC
48 VDC Nominal 34.00 - 75.00 VDC
Reflected Ripple 80 m A
Input Reverse Voltage Protection Shunt Diode
HBD dual output, DC/DC converters feature high
efficiency, 1500 VDC isolation, and open-frame
packaging. The HBD family allows board designers
to deliver any combination of power from
either output, up to each model’s maximum rating.
The HBD is available in 5V/3.3V or 3.3V/2.5V
combinations in either a 24V or 48V input version. The
HBD uses planar magnetics and has an MTBF of over a
million hours.
Independent Dual Outputs
Flexible Load Sharing
High Efficiency Topology
Open-Frame Design
Planar Magnetics
DESCRIPTION FEATURES
Input
Efficiency vs. Load (24V Input)
Efficiency vs. Load (48V Input)
Notes
1 For negative logic, add suffix “N” to model number.
MTBF predictions may vary slightly from model to model.
Specifications typically at 25°C, normal line, and full load, unless otherwise
stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with
commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model. Please consult factory
for specific model information.
Units are water-washable and fully compatible with commercial spray or
immersion post wave-solder washing equipment.
Turn-On Time 10 ms
Remote Shutdown Positive Logic
Switching Frequency 500 kHz
Isolation
Input - Output 1500 VDC
Input - Case 1050 VDC
Output - Case 500 VDC
Temperature Coefficient 0.03%/°C
Case Temperature
Operating Range -40 To +100°C
Storage Range -40 To +125°C
Thermal Shutdown Range 105 To 115°C
Humidity Max., Non-Condensing 95%
Vibration, 3 Axes, 5 Min Each 5 g
MTBF (Bellcore TR-NWT-000332) 1.3 x 106 Hrs
Safety UL, CUL, VDE
Weight (approx.) 2.4 oz
General
Setpoint Accuracy ± 1%
Line Regulation Vin Min. - Vin Max., I out Rated, Output 1 0.2% Vout
Line Regulation Vin Min. - Vin Max., I out Rated, Output 2 1.0% Vout
Load Regulation Iout Min. - Iout Max., Vin Nom., Output 1 0.5% Vout
Load Regulation Iout Min. - Iout Max., Vin Nom., Output2 1.0% Vout
Minimum Output Current 10% Iout Rated
Dynamic Regulation, Loadstep 25% Iout
Pk Deviation 4% Vout
Settling Time 500
µ
s
Voltage Trim Range (5V/3.3V Units) ±10%
Power Limit Threshold Range, % of Iout Rated 110 - 140%
OVP Trip Range (Main Ouput) 115 - 140% Vout Nom.
Output
2
Thermal Impedance
Natural Convection 6.6 °C/W
100 LFM 5.7 °C/W
200 LFM 4.2 °C/W
300 LFM 3.1 °C/W
400 LFM 2.6 °C/W
Tolerances
Note:
Thermal impedance data is dependent on
many environmental factors. The exact
thermal performance should be validated for
specific application.
HBD SERIES - DUAL OUTPUT, 60 WATT
MECHANICAL DRAWING
1-V
in
2 Case
3On/Off
4+V
in
5+V
out 2
6- V
out 2
7 Trim 2
8+V
out 1
9-V
out 1
10 Trim 1
Inches: (Millimeters)
.XX ± 0.020 .X ± 0.5
.XXX ± 0.010 .XX ± 0.25
Pin:
± 0.002 ± 0.05
(Dimensions as listed unless otherwise
specified.)
Pin Function
10
9
8
7
6
5
4
3
2
1
BOTTOM VIEW
1.500"(38.1mm)
1.200"(30.5mm)
0.900"(22.9mm)
0.500"(12.7mm)
0.200"(5.1mm)
-0.100"(-2.5mm)
1.700"(43.2mm)
-0.50"(-12.7mm)
-0.300"(-7.6mm)
1.400"(35.6mm)
1.000"(25.4mm)
0.400"(10.2mm)
0
(12.7mm)
0.50"
(0.6mm)
.025" REF.
(1.0mm)
DIA 0.040"
(4.6mm)
0.18"
(61.0mm)
2.40
"
(57.9mm)
2.28
"
M3X.5 THROUGH 4PL
MOUNTING INSERTS
0
(-4.8mm)
-0.19"
(48.3mm)
1.900"
Vin
(Volts)
Vin Range
(Volts)
Iin Max.*
(Amps)
Vout
(Volts)
Iout Rated
(Amps)
Ripple & Noise
Pk-Pk (mV)
Efficiency
Typ. ** Model
24
24
24
48
48
48
18 - 36
18 - 36
18 - 36
34 - 75
34 - 75
34 - 75
2.89
4.54
3.02
1.51
1.62
2.27
3.3/2.5
5.0/3.3
5.0/3.3
5.0/3.3
3.3/2.5
5.0/3.3
12/15
12/15
8/12
8/12
12/15
12/15
75/75
100/75
100/75
100/75
75/75
100/75
75%
78%
80%
80%
75%
79%
HBD040YED-A
HBD060YGE-A
HBD040YGE-A
HBD040ZGE-A
HBD040ZED-A
HBD060ZGE-A
Denotes advanced product release. Consult factory for product availability.
* Maximum input current at minimum input voltage, maximum rated output power.
** At nominal Vin, rated output.
Note: Current can be drawn from either output to its maximum value, or from both outputs to a combined total of 15A.
MODELS - (See the last page of this file for options.)
3
OPTIONS
When ordering equipment options, use the following suffix information. Select the option(s) that
you prefer and add them to the model number. Example ordering options are located below the
options table.
OPTION SUFFIX APPLICABLE SERIES REMARKS
Negative Logic N HAS, HBD, HBS, HES, LES, QBS,
QES, TES, TQ D TTL “Low” Turns Module ON
TTL “High” Turns Module OFF
Lucent Compatible Trim T HAS, HBD, HBS, HES, QBS, QES
Terminal Strip TS XWS, XWD, XWT
Trim 1 IAS, LES
Enable 2 IAD, IAS, LES, SMS
Trim and Enable 3 IAS, LES
Current Share 4 SMS
Headerless Y E ncapsulated EWS, IWS, OWS
PIN LENGTH AND HEATSINK
OPTIONS Standard Pin Length is 0.180”
(4.6mm)
0.110” (2.8mm) Pin Length 8 All Units (Except SMS)
0.150” (3.8mm) Pin Length 9 All Units (Except SMS)
0.24” (6.1mm) Horizontal Heatsi nk 1H All Units (Except DIP, SIP, and SM
Packages) Includes Thermal Pad
0.24” (6.1mm) Vertical Heatsink 1V All Units (Except DIP, SIP, and SM
Packages) Includes Thermal Pad
0.45” (11.4mm) Horizontal
Heatsink 2H All Units (Except DIP, SIP, and SM
Packages) Includes Thermal Pad
0.45” (11.4mm) Vertical Heatsink 2V All Units (Except DIP, SIP, and SM
Packages) Includes Thermal Pad
0.95” (24.1mm) Horizontal
Heatsink 3H All Units (Except DIP, SIP, and SM
Packages) Includes Thermal Pad
0.95” (24.1mm) Vertical Heatsink 3V All Units (Except DIP, SIP, and SM
Packages) Includes Thermal Pad
Example Options:HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent compatible trim, and
0.95” vertical heatsink.
LES015YJ-3N = LES015YJ with optional trim and enable, negative logic.
QBS066ZG-AT8 = QBS066ZG-A with Lucent compatible trim and 0.110” pin length.
NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.