Optek Technology
OPTEK Technology Inc.— 1645 Wallace Drive, Carrollton, Texas 75006
Phone: (800) 341-4747 FAX: (972) 323– 2396 sensors@optekinc.com www.optekinc.com
Issue A 04.04
Page 2 of 5
Vertical Cavity Surface Emitting Laser in
FT Optical Sub-Assembly
OPV314F, OPV314YF, OPV315F, OPV315YF
Absolute Maximum Ratings (TA = 25o C unless otherwise noted)
Storage Te mperat ur e -40° C to +100° C
Lead Soldering T emperature (1/16” (1.6mm) from case for 5 seconds with soldering iron) 260° C (1)
Operating T emper at ure 0° C to +70° C
Maximum Revers e Volt ag e 10 V
Maximum For ward Peak Current 20 mA
Electrical Characteristics (TA = 25°C unless otherwise noted)
SYMBOL PARAMETER MIN TYP MAX UNITS TEST CONDITION
PT50 Total Coupled Power (OPV314, OPV314Y) 500 µW IF = 7 mA,
Fiber 50/125µm
(OPV315, OPV315Y) 250 µW
ITH Threshold Cu rrent 0.8 3.0 mA Note1
VF Forward Voltage 1.6 2.2 V IF = 7 mA
IR Reverse Current 35 nA VR = 5 V
RS Series Resist ance 20 55 ohms Note 2
η Slope Efficiency (OP V314, OPV3 14Y) 50 µW/mA
Note 3
(OPV315, OPV315Y) 25 µW/mA
IRPD Reverse Current, photo diode 30 nA VR = 40 V
Monitor Current (OPV314 , OPV314Y) 50 µΑ IF = 7 mA, VR = 5 V
(OPV315, OPV315Y) 100 µΑ
λ Wavelength 840 860 nm
∆λ Optical Bandwidth 0.85 nm
tr Rise Time 90 ps 20% to 80%
tf Fall Time 120 ps 80% to 20%
NRI Relative Intensity Noise -123 db/Hz
∆η/∆Τ Temp Coefficient of Slope Efficiency -0.4 %/°C (0° - 70° C)
∆lTH/∆T Temp Coefficient of Threshold Current ±0.1 mA 0° - 70° C
∆λ/∆T Temp Coefficient of Wavelength 0.06 nm/°C 0° - 70° C
∆Vf/∆T Temperature Coefficient for VF -2.5 mV/°C
IM
NOTES:
(1) Threshold Current is based on the two line intersection method specified in Telcordia GR-468-Core. Line 1 from 4 mA to 6 mA.
Line 2 from 0 mA to 0.5 mA.
(2) Series Resistance is the slope of the Voltage-Current line from 5 to 8 mA.
(3) Slope efficiency, is the slope of the best fit LI line from 5 mA to 8 mA using no larger than .25 mA test interval points.
Measured with a 50/125 µm fiber.
(4) Linearity—Using data points taken for slope efficiency above, data L/delta I shall be calculated for each adjacent pair of points.