Doc #97035 DATA DELAY DEVICES, INC. 1
12/10/97 3 Mt. Prospect Ave. Clifton, NJ 07013
5-TAP, ECL-INTERFACED
FIXED DELAY LINE
(SERIES DDU11H)
FEATURES PACKAGES
• Five equally spaced outputs
• Fits standard 16-pin DIP socket
• Auto-insertable
• Input & outputs fully 10KH-ECL interfaced & buffered
FUNCTIONAL DESCRIPTION
The DDU11H-series device is a 5-tap digitally buffered delay line. The
signal input (IN) is reproduced at the outputs (T1-T5), shifted in time by an
amount determined by the device dash number (See Table). For dash
numbers less than 10, the total delay of the line is measured from T1 to
T5. The nominal tap-to-tap delay increment is given by one-fourth of the
total delay, and the inherent delay from IN to T1 is nominally 1.5ns. For dash numbers greater than or
equal to 10, the total delay of the line is measured from IN to T5. The nominal tap-to-tap delay increment
is given by one-fifth of this number.
SERIES SPECIFICATIONS
• Minimum input pulse width: 20% of total delay
• Output rise time: 2ns typical
• Supply voltage: -5VDC ± 5%
• Power dissipation: 200mw typical (no load)
• Operating temperature: -30° to 85° C
• Temp. coefficient of total delay: 100 PPM/°C
25% 25% 25% 25%
VCC GNDIN T1 T2 T3 T4 T5
Functional diagram for dash numbers < 10
1.5ns
20% 20% 20% 20% 20%
VCC GNDIN T1 T2 T3 T4 T5
Functional diagram for dash numbers >= 10
1997 Data Delay Devices
delay
devices, inc.
2
3
4
5
6
7
8
15
14
13
12
11
10
9
N/C
T2
T4
IN
N/C
N/C
T1
T3
T5
N/C
N/C
N/C
N/C
16
15
14
13
1
3
4
5
8
GND
T2
T4
IN
VEE
GND
T1
T3
T5
DDU11H-xx DIP
DDU11H-xxM Military DIP DDU11H-xxC3 SMD
DDU11H-xxMC3 Mil SMD
PIN DESCRIPTIONS
IN Signal Input
T1-T5 Tap Outputs
VEE -5 Volts
GND Ground
DASH NUMBER SPECIFICATIONS
Part
Number Total
Delay (ns) Delay Per
Tap (ns)
DDU11H-4 2 ± 1.0 * 0.5 ± 0.3
DDU11H-5 4 ± 1.0 * 1.0 ± 0.3
DDU11H-8 6 ± 2.0 * 1.5 ± 0.4
DDU11H-10 10 ± 2.0 2.0 ± 0.4
DDU11H-20 20 ± 3.0 5.0 ± 1.0
DDU11H-25 25 ± 3.0 5.0 ± 2.0
DDU11H-50 50 ± 3.0 10.0 ± 2.0
DDU11H-75 75 ± 4.0 15.0 ± 2.0
DDU11H-100 100 ± 5.0 20.0 ± 2.0
DDU11H-150 150 ± 7.5 30.0 ± 2.0
DDU11H-200 200 ± 10.0 40.0 ± 2.0
DDU11H-250 250 ± 12.5 50.0 ± 2.5
DDU11H-300 300 ± 15.0 60.0 ± 3.0
DDU11H-400 400 ± 20.0 80.0 ± 4.0
DDU11H-500 500 ± 25.0 100.0 ± 5.0
* Total delay is referenced to first tap output
Input to first tap = 1.5ns ±± 1ns
NOTE: Any dash number between 4 and 500
not shown is also available.