DDU11H
Doc #97035 DATA DELAY DEVICES, INC. 1
12/10/97 3 Mt. Prospect Ave. Clifton, NJ 07013
5-TAP, ECL-INTERFACED
FIXED DELAY LINE
(SERIES DDU11H)
FEATURES PACKAGES
Five equally spaced outputs
Fits standard 16-pin DIP socket
Auto-insertable
Input & outputs fully 10KH-ECL interfaced & buffered
FUNCTIONAL DESCRIPTION
The DDU11H-series device is a 5-tap digitally buffered delay line. The
signal input (IN) is reproduced at the outputs (T1-T5), shifted in time by an
amount determined by the device dash number (See Table). For dash
numbers less than 10, the total delay of the line is measured from T1 to
T5. The nominal tap-to-tap delay increment is given by one-fourth of the
total delay, and the inherent delay from IN to T1 is nominally 1.5ns. For dash numbers greater than or
equal to 10, the total delay of the line is measured from IN to T5. The nominal tap-to-tap delay increment
is given by one-fifth of this number.
SERIES SPECIFICATIONS
Minimum input pulse width: 20% of total delay
Output rise time: 2ns typical
Supply voltage: -5VDC ± 5%
Power dissipation: 200mw typical (no load)
Operating temperature: -30° to 85° C
Temp. coefficient of total delay: 100 PPM/°C
25% 25% 25% 25%
VCC GNDIN T1 T2 T3 T4 T5
Functional diagram for dash numbers < 10
1.5ns
20% 20% 20% 20% 20%
VCC GNDIN T1 T2 T3 T4 T5
Functional diagram for dash numbers >= 10
1997 Data Delay Devices
data
delay
devices, inc.
3
1
2
3
4
5
6
7
8
16
15
14
13
12
11
10
9
GND
N/C
T2
T4
IN
N/C
N/C
VEE
GND
T1
T3
T5
N/C
N/C
N/C
N/C
16
15
14
13
1
3
4
5
8
GND
T2
T4
IN
VEE
GND
T1
T3
T5
DDU11H-xx DIP
DDU11H-xxM Military DIP DDU11H-xxC3 SMD
DDU11H-xxMC3 Mil SMD
PIN DESCRIPTIONS
IN Signal Input
T1-T5 Tap Outputs
VEE -5 Volts
GND Ground
DASH NUMBER SPECIFICATIONS
Part
Number Total
Delay (ns) Delay Per
Tap (ns)
DDU11H-4 2 ± 1.0 * 0.5 ± 0.3
DDU11H-5 4 ± 1.0 * 1.0 ± 0.3
DDU11H-8 6 ± 2.0 * 1.5 ± 0.4
DDU11H-10 10 ± 2.0 2.0 ± 0.4
DDU11H-20 20 ± 3.0 5.0 ± 1.0
DDU11H-25 25 ± 3.0 5.0 ± 2.0
DDU11H-50 50 ± 3.0 10.0 ± 2.0
DDU11H-75 75 ± 4.0 15.0 ± 2.0
DDU11H-100 100 ± 5.0 20.0 ± 2.0
DDU11H-150 150 ± 7.5 30.0 ± 2.0
DDU11H-200 200 ± 10.0 40.0 ± 2.0
DDU11H-250 250 ± 12.5 50.0 ± 2.5
DDU11H-300 300 ± 15.0 60.0 ± 3.0
DDU11H-400 400 ± 20.0 80.0 ± 4.0
DDU11H-500 500 ± 25.0 100.0 ± 5.0
* Total delay is referenced to first tap output
Input to first tap = 1.5ns ±± 1ns
NOTE: Any dash number between 4 and 500
not shown is also available.
DDU11H
Doc #97035 DATA DELAY DEVICES, INC. 2
12/10/97 Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com
APPLICATION NOTES
HIGH FREQUENCY RESPONSE
The DDU11H tolerances are guaranteed for input
pulse widths and periods greater than those
specified in the test conditions. Although the
device will function properly for pulse widths as
small as 20% of the total delay and periods as
small as 40% of the total delay (for a symmetric
input), the delays may deviate from their values
at low frequency. However, for a given input
condition, the deviation will be repeatable from
pulse to pulse. Contact technical support at Data
Delay Devices if your application requires device
testing at a specific input condition.
POWER SUPPLY BYPASSING
The DDU11H relies on a stable power supply to
produce repeatable delays within the stated
tolerances. A 0.1uf capacitor from VEE to GND,
located as close as possible to the VEE pin, is
recommended. A wide VEE trace and a clean
ground plane should be used.
DEVICE SPECIFICATIONS
TABLE 1: ABSOLUTE MAXIMUM RATINGS
PARAMETER SYMBOL MIN MAX UNITS NOTES
DC Supply Voltage VEE -7.0 0.3 V
Input Pin Voltage VIN VEE - 0.3 0.3 V
Storage Temperature TSTRG -55 150 C
Lead Temperature TLEAD 300 C10 sec
TABLE 2: DC ELECTRICAL CHARACTERISTICS
(0C to 75C)
PARAMETER SYMBOL MIN TYP MAX UNITS NOTES
High Level Output Voltage VOH -1.020 -0.735 VVIH = MAX,50 to -2V
Low Level Output Voltage VOL -1.950 -1.600 VVIL = MIN, 50 to -2V
High Level Input Voltage VIH -1.070 V
Low Level Input Voltage VIL -1.480 V
High Level Input Current IIH 475 µAVIH = MAX
Low Level Input Current IIL 0.5 µAVIL = MIN
DDU11H
Doc #97035 DATA DELAY DEVICES, INC. 3
12/10/97 3 Mt. Prospect Ave. Clifton, NJ 07013
PACKAGE DIMENSIONS
DDU11H-xx (Commercial DIP)
DDU11H-xxM (Military DIP)
.150
±.030
.800 TYP.
1 3 4 5 8
16 15 14 13
.320
MAX.
.018
TYP.
.400
TYP.
.300
TYP.
.010 TYP.
.700 TYP.
.020
TYP.
.100
TYP.
DDU11H-xxC3 (Commercial SMD)
DDU11H-xxMC3 (Military SMD)
.880±.020
.882
±.005
.020 TYP.
.040
TYP.
.100
.090
.700
.280
MAX.
.590
MAX.
.010±.002
.050
±.010
.710
±.005 .007
±.005
12345678
910111213141516
DDU11H
Doc #97035 DATA DELAY DEVICES, INC. 4
12/10/97 Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com
DELAY LINE AUTOMATED TESTING
TEST CONDITIONS
INPUT: OUTPUT:
Ambient Temperature: 25oC ± 3oCLoad: 50 to -2V
Supply Voltage (Vcc): -5.0V ± 0.1V Cload:5pf ± 10%
Input Pulse: Standard 10KH ECL Threshold: (VOH + VOL) / 2
levels (Rising & Falling)
Source Impedance: 50 Max.
Rise/Fall Time: 2.0 ns Max. (measured
between 20% and 80%)
Pulse Width: PWIN = 1.5 x Total Delay
Period: PERIN = 10 x Total Delay
NOTE: The above conditions are for test only and do not in any way restrict the operation of the device.
T1
OUT
TRIG
IN
REF
TRIG
Test Setup
DEVICE UNDER
TEST (DUT)
PULSE
GENERATOR
IN
T2
T3
T4
T5
Timing Diagram For Testing
TRISE TFALL
PERIN
PWIN
TRISE TFALL
20%
20%
50%
50%
80%
80%
50%
50%
VIH VIL
VOH VOL
INPUT
SIGNAL
OUTPUT
SIGNAL