INTEGRATED CIRCUITS DIVISION
www.ixysic.com
2R08
PLA192
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to the
device. Functional operation of the device at conditions beyond
those indicated in the operational sections of this data sheet is
not implied.
Typical values are characteristic of the device at +25°C, and
are the result of engineering evaluations. They are provided for
information purposes only, and are not part of the manufacturing
testing requirements.
Parameter Rating Units
Blocking Voltage 600 VP
Reverse Input Voltage 5 V
Input Control Current 50 mA
Peak (10ms) 1 A
Input Power Dissipation 1150 mW
Total Package Dissipation 2800 mW
Isolation Voltage, Input to Output
(60 Seconds) 5000 Vrms
ESD Rating, Human Body Model 4 kV
Operational Temperature -40 to +85 ºC
Storage Temperature -40 to +125 ºC
1 Derate linearly 1.33 mW / ºC
2 Derate linearly 6.67 mW / ºC
Absolute Maximum Ratings @ 25ºC (Unless Otherwise Noted)
Electrical Characteristics @ 25ºC (Unless Otherwise Noted)
Parameters Conditions Symbol Min Typ Max Units
Output Characteristics
Load Current
Continuous, AC/DC Configuration - IL
- - 150 mArms / mADC
Continuous, DC-Only Configuration - - - 220 mADC
Peak t=10ms ILPK - - ±400 mAP
On-Resistance
AC/DC Configuration IL=150mA RON
- 13.3 22
DC-Only Configuration IL=220mA - 4.15 8
Off-State Leakage Current VL=600VPILEAK -- 1 A
Switching Speeds
Turn-On IF=5mA, VL=10V ton -- 5 ms
Turn-Off toff -- 5
Output Capacitance IF=0mA, VL=50V, f=1MHz COUT -10 - pF
Input Characteristics
Input Control Current to Activate IL=100mA IF- 0.22 5 mA
Input Control Current to Deactivate - IF0.1 0.21 - mA
Input Voltage Drop IF=5mA VF0.9 1.2 1.5 V
Reverse Input Current VR=5V IR--10 A
Common Characteristics
Input to Output Capacitance VIO=0V, f=1MHz CIO -3 - pF
PLA192E Safety and Insulation Ratings
Parameters Conditions Symbol Min Max Units
Pollution Degree 2 according to DIN VDE 0109 - ----
Highest Allowable Over-Voltage Transient Voltage VIOTM 7071 - VP
Maximum Working Insulation Voltage Recurring Voltage VIORM 1000 - VP
Partial Discharge Test Voltage DIN EN 60747-5-5 Method B VPR - 1875 VP
Isolation Test Voltage - VISO - 5000 Vrms
Creepage Distance - - 7.6 - mm
Clearance Distance - - 7.6 - mm