Minimum Order Information Required
■Frequency + Model Number + Load + Enable +
Termination + Frequency Tolerance @ 25°C + Frequency
Stability Over Operating Temperature Range +
Operating Range
Frequency Frequency Supply Supply Operating Frequency Stability Available Rise Fall Duty Model
Range Tolerance Current Voltage Temperature Over Operating Temperature Time(tr) Time (tf) Cycle Number
@25°C±2°C (typical) Range Minimum Maximum
1.25 to A = ±100ppm 12mA 5.0V±0.5V –10 to 70°C ±10ppm ±50ppm 6ns 6ns 40/60% CXO-M
24.0MHz B = ±1000ppm –40 to 85°C ±20ppm ±100ppm
C = ±10000ppm
–55 to 125°C ±30ppm ±100ppm
> 24.0 to A = ±100ppm 16mA 5.0V±0.5V –10 to 70°C ±10ppm ±50ppm 6ns 6ns 40/60% CXO-M
30.0MHz B = ±1000ppm –40 to 85°C ±20ppm ±100ppm
C = ±10000ppm
–55 to 125°C ±30ppm ±100ppm
> 30.0 to A = ±100ppm 20mA 5.0V±0.5V –10 to 70°C ±10ppm ±50ppm 6ns 6ns 40/60% CXO-M
40.0MHz B = ±1000ppm –40 to 85°C ±20ppm ±100ppm
C = ±10000ppm
–55 to 125°C ±30ppm ±100ppm
> 40.0 to A = ±100ppm 25mA 5.0V±0.5V –10 to 70°C ±10ppm ±50ppm 6ns 6ns 40/60% CXO-M
70.0MHz B = ±1000ppm –40 to 85°C ±20ppm ±100ppm
C = ±10000ppm
–55 to 125°C ±30ppm ±300ppm
Ordering Example 50.0MHz CXO-M 10 TSM1 A50 C
Frequency
Model No
Load: 10 = 10 TTL
Enable: T = Tri-State; N = Non tri-state
Termination
Frequency Tolerance @ 25°C
Frequency Stability Over Operating Temperature Range
Operating Temperature Range: C = –10 to 70°C; I = –40 to 85°C; M = –55 to 125°C
Please note: Above parameters are measured at @25°C with a 10MΩand 10pF load at @5.0V
Electrical Specification – maximum limiting values
33..33VV HHCCMMOOSSvveerrssiioonn,, ootthheerr ffrreeqquueennccyy ttoolleerraanncceess aanndd hhiigghheerr ffrreeqquueenncciieess aarree aavvaaiillaabbllee ssoo pplleeaassee ccoonnttaacctt oouurr ssaalleess ooffffiiccee
Europe Tel: +44 (0)1460 270200 Fax: +44 (0)1460 72578 Website: www.cmac.com
Americas Tel: +1 919 941 9333 Fax: +1 919 941 9371
Asia Tel: +86 755 8826 5991 Fax: +86 755 8826 5990