Data Sheet FieldIT SS/S264_3 2600T Series Pressure Transmitters Models S264 Remote Seals Wide range of remote seal types - allow optimum design for each application without compromise of performance Large selection of options, materials and fill fluids - meet nearly all process requirements All welded constructions - combine an economically feasible and technically sound solution ensuring total reliability at line pressure down to full vacuum Special designed remote seals for individual process solutions - add flexibility for most demanding services ABB 2600T Series Engineered solutions for all applications 2600T Pressure Transmitters Models S264 SS/S264_3 Remote Seals Overview Seal system selection criteria The S26 seals are used in combination with 2600T transmitters, allowing differential, gauge or absolute pressure measurements. Connection of the seal(s) to the relevant transmitter can be achieved as follows : - directly mounted with a short capillary connecting the "integral" seal to the transmitter sensor; - through a capillary system which link the transmitter sensor to a "remote" seal of any version. Using remote seal the transmitter can be selected with - two seals using same fill fluid, capillary and diaphragm size - one seal having the other side configured with a process flange for wet/dry leg connection or a blind flange providing vacuum or atmospheric reference. Model 264HR/NR transmitters have always one remote seal only, with a selectable reference to atmosphere or vacuum respectively for gauge or absolute pressure measurements. The S26 Series Seal System is a protective device used to isolate 2600T series transmitters from the process fluid. The seal system provides a flexible diaphragm seal between the process fluid and a liquid filled capillary tube connected to the body of the transmitter. The diaphragm isolates the process fluid while the filled capillary tube hydraulically transmits the process pressure to the transmitter sensor. The capillary of remote seal is corrosion-resistant with robust costruction in stainless steel with spiral armour protection, also PVC jacket; PVC protection is always recommended except for high temperature application, where stainless steel armour is suggested. The all welded construction assures reliable operation over the widest range of operating temperature and under vacuum conditions. For certain applications, use of seal is necessary to prevent the process fluid from leaving its enclosure, due to reasons such as : * the process fluid has solids in suspension or is highly viscous and can foul impulse lines. * the process fluid can solidify in impulse lines or the transmitter. * the process fluid is too hazardous to enter the control area where the transmitter is located. * the process temperature exceeds the recommended limits for the transmitter. * the application is interface level or density measurement. Remote seals offer the required constant and equal specific gravity of the pressure transfer fluid on the high and low sides of the transmitter. * the transmitter must be located away from the process for easier maintenance. The S26 series is available with process connections for ANSI or DIN pipe flanges, wedge flow elements, chemical tees, and threaded pipe fittings. Extended diaphragm remote seals, suitable for connection to 2in - 3in or 4in flanged tank nozzles or flanged tees, permit the seal diaphragm to be located flush with the inside of a tank or pipe. Sanitary type seals meet the stringent requirements of sanitary food, dairy, pharmaceutical and Bio Tech applications, offering FDA approved fillings and compliance with 3-A Sanitary Standards. Fill fluids with FDA are defined as food fills and are Generally Recognized As Safe (GRAS) by the US Food and Drug Administration (FDA). Application of an S26 system in direct mount or remote seal configuration to 2600T transmitters affects performances of original devices. Effects are evident in: - Accuracy - Temperature effects - Dynamic response 2 * Accuracy Accuracy is only marginally affected when seal diaphragm stiffness is relevant compared with sensor stiffness. This is the only characteristic of the S26 system which has role on accuracy performance. High stiffness of diaphragm associated with low URL might produce increased errors of linearity, hysteresis, and long term stability; when diaphragm stiffness is accuracy related also temperature effects are significantly affected. Some basic considerations on diaphragm stiffness help understanding effects introduced by S26 system associated with transmitters. This is physically defined by the ratio between the pressure variation applied to the diaphragm and the corresponding volume variation. The stiffness is not linear along the whole diaphragm volumetric displacement, but the S26 design is such to maintain the system linear within the service conditions of the transmitter such as: - Operating pressure range - Operating static pressure (for differential transmitters) - Ambient & process temperature limits Diaphragm stiffness is a function of material & thickness (elastic coefficient), diameter (type), convolution shape and geometry (design defined) * Temperature effects S26 system has effect on temperature performance of the complete transmitter. This effect is mostly on zero of the instrument and is produced by the expansion of the fill fluid into the closed volume formed by the transmitter flange cavity the capillary volume and the remote seal volume. This volume filled with a fluid with specific expansion coefficient; change in temperature of the measuring device produce a volume variation which is absorbed by the remote diaphragm, whose stiffness produces a change in the fluid pressure: this is the zero error. In real application the transmitter/seal system is not the same and stable temperature. Therefore the errors referred in this document for each type of diaphragm and different fluids should be taken as a reference for qualitatively evaluation and not a true behaviour in normal application conditions. Should again be recognized that the stiffness of diaphragm and in this case, the thermal coefficient of fluid are the parameter to take into account. * Time response Application of S26 seal to transmitters increases the original time response. The amount of the increase depends from the number of elements and condition of the instrument as follows : - transmitter sensor range - physical configuration (i.e. a remote seal on other side) - type of measure/number of seal (one or two) - fill fluid viscosity of the S26 system applied - ambient temperature (affects the transmitter and the capillary) and process temperature on the seal diaphragm - capillary length 2600T Pressure Transmitters Models S264 SS/S264_3 The delay introduced by the seal may be considered as an added constant time to the one of the associated transmitter For obtaining the best application solution : * choose sensor code with URL closest to application SPAN * select largest diameter diaphragm seal related to URL. * keep the capillary length as short as possible * select the fill fluid that suits the most extreme process conditions expected (highest temperature and lowest pressure) and it is compatible with the process fluid. * In vacuum application, choose always the all welded version and mount the transmitter primary 30 cm/12 inches or more below the bottom seal connection. * In a two-seal system use the same diaphragm size, capillary length and fill fluid on each side of the transmitter. The mnemonics will be used as shortest cross references with the transmitter data sheet which should be read in conjunction with this data sheet. Model Industrial application in chemical, sanitary, food and any other process industries may require seal configurations and/or process connection different from those reported in this document. Each "special" should be evaluated by ABB to check the correctness and its level of functionality. Ask for the "S26 series seal form" to define precisely the measuring problem and application requirements. The following table shows the types of standard seals considered in this leaflet. Mnemonic Wafer Wafer (food) 1 1/2in / DN40 2in / DN50 3in / DN80 S264C Chemical tee flanged 3in P3 Flanged flush diaphragm 2in / DN50 3-4in / DN80-100 P2 P3 Flanged extended diaphragm 2in / DN50 3in / DN80 4in / DN100 E2 E3 P3 S264U Union 1 1/2n P1.5 S264T Threaded off-line 2 1/2in T2.5 S264M Flanged off-line 2 1/2n T2.5 S264S Union nut Triclamp Cherry Burrel Sanitary, Aseptic 2in / F50 3in / F80 4in S2 S3 S3 S264B Button 1in B1 S264P Urea service flanged 1 1/2in 2 1/2in Ordering Information Transmitter Product Code 264DRFSSA1AH-V1E1D3 Seal System Product Code S264WHBCDFSBEH1 Size S264W S264F The transmitter and each seal system are each identified by a product code number. These code numbers are stamped on the transmitter nameplate and each character identifies specific product features. Refer to ordering information for a detailed explanation of the product code numbers. A typical example of the product code stamping is as follows : Seal type P1.5 P2 P3 U1.5 U2.5 ABB can also cooperate with you by developing a special remote seal for problems requiring individual solutions. Please contact your local ABB office or representative for additional information. FILL FLUID CHARACTERISTICS (Table A) FILL FLUIDS (APPLICATION) Silicone oil-DC200TM (General purpose) Silicone oil-AN140TM (High temperature) Silicone Polymer-Syltherm XLTTM (Low temperature) Vegetable oil-Neobee M-20TM (Food-Sanitary) FDA Glycerin Water (70%) (Food-Sanitary) FDA Mineral oil-MARCOL 82TM (Food-Sanitary) FDA Inert - GaldenTM (Oxygen Service) Inert - HalocarbonTM 4.2 (Oxygen Service) ABB fill (Paints and specials) OPERATING CONDITIONS Tmax @ Pabs>of 200 (390) @ 35mbar 380 (716) @ 1bar 100 (212) @ 110mbar 200 (390) @ 1bar 93 (200) @ 1bar 200 (390) @ 200mbar 160 (320) @ 1bar 180 (356) @ 400mbar 300 (572) @ 400mbar Pmin mbar abs (psia) 0.7 (0.01) 0.7 (0.01) 2 (0.03) 130 (1.9) 1000 (14.5) 33 (0.5) 0.7 (0.01) 4 (0.06) 0.7 (0.01) SPECIFICATION AT 25 C (77 F) Tmax @ P min Tmin 160 (320) 300 (572) 20 (68) 150 (300) 93 (200) 40 (104) 65 (150) 70 (158) 160 (320) -40 (-40) -5 (+23) -100 (-148) -18 (0) -7 (+20) -40 (-40) -18 (0) -20 (-4) -10 (+14) Specific gravity Kinematic viscosity (cSt) Thermal expansion (x 10-3 / C) 0.934 10 1.08 1.07 40 0.64 0.852 1.4 1 0.92 9.8 1.2 1.08 2.2 0.36 0.84 26 1.04 1.82 9 1.1 1.87 6.3 0.864 1.04 16 0.92 Absolute viscosity (cP) = Kinematic Viscosity (cSt) x Specific gravity at specified temperature. The absolute viscosity value is used for response time calculation. SEALS DIMENSIONS ON FOLLOWING PAGES ARE IN mm (in) 3 2600T Pressure Transmitters Models S264 SS/S264_3 S264W Model Wafer Remote Seal The wafer remote seal is designed to be clamped between two ANSI or DIN raised face flanges. The diaphragm side of the seal faces the process flange and a blind back-up flange is used on the other side of the seal. The wafer variant is also available as food design for 11/2in and 3in sizes. Raised Face Flange H DIMENSIONS mm (in) Size Process Connection 134 (5.3) Capillary to instrument B A A (dia) B (dia) H 1 1 /2in 47 (1.85) 73.2 (2.87) 23 (0.9) 2in 60 (2.36) 92.1 (3.62) 23 (0.9) 3in 89 (3.5) 127 (5) 23 (0.9) DN 40 47 (1.85) 88 (3.46) 23 (0.9) DN 50 60 (2.36) 102 (4.02) 23 (0.9) DN 80 89 (3.5) 138 (5.43) 23 (0.9) Capillary to instrument 23 (0.90) 25 (0.98) Capillary to instrument 1 1/2 in wafer food design 4 Capillary to instrument 3in wafer food design 127 (5) 130.8 (5.15) 134 (5.3) 80 (3.15) Gasket seal finish 134 (5.3) 73 (2.87) 47 (1.85) 3.7 (0.14) Gasket seal finish 2600T Pressure Transmitters Models S264 SS/S264_3 Temperature effect Maximum Working Pressure The following table shows the temperature effect for 20K (36F) change, detailed separately for WAFER SEAL ELEMENT : 16 MPa, 160 bar, 2320 psi but not greater than the backup flange rating (not supplied). a) the seal (one element) Vacuum Service Full vacuum subject to fill fluid limits. Refer to table A. b) the capillary per meter Minimum pressure with tantalum diaphragm is 1kPa abs, 10mbar abs, 0.15psia. c) the system (transmitter sensor when combined with a seal of specific size/type) referred to silicone oil (DC 200) filling and AISI 316 L ss diaphragm materials. Process Temperature Limits Same as fill fluid limits. Refer to table A. 260C (500F) for Tantalum diaphragm. 204C (400F) for use with Teflon anti-stick coating. Gasket seat finish smooth (RF or DIN): 0.8m (32AARH) For filling different from silicone oil (DC200) the errors can be multiplied by the thermal expansion coefficient listed in the fill fluid characteristics table. THE ERRORS IN TABLE CAN BE CONSIDERED DIVIDED BY 4 FOR TRANSMITTERS USING SAME REMOTE SEAL ON THE TWO SIDES serrated (RF): 3.2 to 6.3m (125 to 250AARH) Form C (DIN 2526): 160RZ Form E (DIN 2526): 16RZ Wafer Seal Size Seal error 1m Capillary Error System (Sensor) Error 1 1/2in / DN 40 0.87kPa, 8.7mbar, 3.5inH2O 0.3kPa, 3mbar, 1.2inH2O 0.9kPa, 9mbar, 3.6inH2O 2in / DN 50 0.29kPa, 2.9mbar, 1.16inH2O 0.07kPa, 0.7mbar, 0.28inH2O 0.2kPa, 2mbar, 0.8inH2O 3in / DN 80 0.09kPa, 0.9mbar, 0.36inH2O 0.03kPa, 0.3mbar, 0.12inH2O 0.03kPa, 0.3mbar, 0.12inH2O 5 2600T Pressure Transmitters Models S264 SS/S264_3 BASIC ORDERING INFORMATION model S264W Wafer Remote Seal Select one character or set of characters from each category and specify complete catalog number. BASE MODEL - 1st to 5th characters S 2 6 4 W X X X X F X X X X X Wafer Remote Seal Transmitter side of connection - 6th character High side Low side Centering system - 7th character Seat on back diameter (suitable fot RF backup flange) Size - 8th character H L B 1 1/2in ANSI 2in ANSI 3in ANSI 1 1/2in ANSI food design 3in ANSI food design DIN DN40 DIN DN50 DIN DN80 Seat finish - 9th character Serrated finish (suitable for RF) Smooth finish (suitable for RF) Serrated finish to DIN 2526 Form C (up to PN40) Serrated finish to DIN 2526 Form E (PN64 to PN160) Smooth finish (suitable for DIN) A B C 1 2 D E F (Notes 1, 3) (Note 1) (Notes 2, 3) (Notes 2, 3) (Notes 2, 3) D E R S T Use code - 10th character Diaphragm material - 11th character AISI 316 L ss Hastelloy C276TM Tantalum AISI 316 L ss with anti-stick coating Hastelloy C276TM with anti-stick coating AISI 316 L ss with anti-corrosion and anti-stick coating (Note 4) (Note 4) (Notes 4, 5) (Notes 4, 5) (Notes 4, 6) NACE NACE NACE NACE NACE S H T K Y W Capillary protection - 12th character AISI 316 ss armour AISI 316 ss armour with PVC protective cover (RECOMMENDED FOR HIGH TEMPERATURE) A B Capillary length m (feet) - 13th character 1 (3) 1.5 (5) 2 (7) 2.5 (8) 3 (10) 3.5 (12) 4 (13) 4.5 (15) 5 (17) 5.5 (18) 6 (20) 6.5 (22) 7 (23.5) 7.5 (25) 8 (27) 9 (30) 10 (33) 12 (40) 14 (47) 16 (53) A B C D E F G H J K L M N P Q R S T U V Fill fluid - 14th character Silicone oil Inert fluid - Galden Inert fluid - Halocarbon ABB fill SIlicone oil for high temperature Silicone polymer for low temperature Mineral oil (FDA approved) Vegetable oil (FDA approved) Glycerin-water (FDA approved) (Notes 3, 7) (Notes 3, 7) (Note 3) (Note 3) (Note 3) (Note 8) (Note 8) (Note 8) S N D K H C W A B Certification - 15th character None Zone "0" protection 6 (Note 9) 1 2 2600T Pressure Transmitters Models S264 Note 1: Not available with DIN size code D, E, F Note 2: Not available with ANSI size code A, B, C Note 3: Not available with food design size code 1, 2 Note 4: Not available with serrated seat code D, R, S Note 5: Not available with size code A, B, D, E, F, 1, 2 Note 6: Not available with size code A, D, 1, 2 Note 7: Suitable for oxygen service Note 8: Suitable for food application Note 9: Not available with diaphragm material code K, Y TM Hastelloy is a Cabot Corporation trademark TM Galden is a Montefluos trademark TM Halocarbon is a Halocarbon Products Co. trademark SS/S264_3 7 2600T Pressure Transmitters Models S264 SS/S264_3 S264C Model Chemical Tee Remote Seal The chemical tee remote seal is designed to connect to a Wedge Flow Element or to any process fitting with appropriate mating condition. Chemical tee elements cannot be connected to a standard ANSI or DIN pipe flange. 8 Mounting Holes dia 8.73 (0.34) Equally Spaced 25 (1) 12 (0.47) dia 89 (3.5) Capillary to instrument dia 111 (4.38) dia 127 (5) 134 (5.3) Diaphragm Surface Temperature effect Maximum Working Pressure The following table shows the temperature effect for 20K (36F) change, detailed separately for 2 MPa, 20 bar, 300 psi Vacuum Service a) Full vacuum subject to fill fluid limits. Refer to table A. Process Temperature Limits Same as fill fluid limits. Refer to table A. 204C (400F) for use with Teflon anti-stick coating. the seal (one element) b) the capillary per meter c) the system (transmitter sensor when combined with a seal of specific size/type) referred to silicone oil (DC 200) filling and AISI 316 L ss diaphragm materials. For filling different from silicone oil (DC200) the errors can be multiplied by the thermal expansion coefficient listed in the fill fluid characteristics table. 204C (400F) with PTFE gasket 340C (645F) with graphite gasket THE ERRORS IN TABLE CAN BE CONSIDERED DIVIDED BY 4 FOR TRANSMITTERS USING SAME REMOTE SEAL ON THE TWO SIDES Chemical Tee Seal Size 3in 8 Seal error 0.09kPa, 0.9mbar, 0.36inH2O 1m Capillary Error 0.03kPa, 0.3mbar, 0.12inH2O System (Sensor) Error 0.03kPa, 0.3mbar, 0.12inH2O 2600T Pressure Transmitters Models S264 SS/S264_3 BASIC ORDERING INFORMATION model S264C Chemical Tee Remote Seal Select one character or set of characters from each category and specify complete catalog number. BASE MODEL - 1st to 5th characters S 2 6 4 C X X X P X X X X X Chemical Tee Remote Seal Transmitter side of connection - 6th character High side Low side Mounting flange - 7th character Integral with seal Size - 8th character 3in (proprietary standard; 20bar rating) H L P G Use code - 9th character Diaphragm material - 10th character AISI 316 L ss Hastelloy C276TM AISI 316 L ss with anti-stick coating Hastelloy C276TM with anti-stick coating AISI 316 L ss with anti-corrosion and anti-stick coating NACE NACE NACE NACE S H K Y W Capillary protection - 11th character AISI 316 ss armour AISI 316 ss armour with PVC protective cover (RECOMMENDED FOR HIGH TEMPERATURE) A B Capillary length m (feet) - 12th character 1 (3) 1.5 (5) 2 (7) 2.5 (8) 3 (10) 3.5 (12) 4 (13) 4.5 (15) 5 (17) 5.5 (18) 6 (20) 6.5 (22) 7 (23.5) 7.5 (25) 8 (27) 9 (30) 10 (33) A B C D E F G H J K L M N P Q R S Fill fluid - 13th character Silicone oil Inert fluid - Galden Inert fluid - Halocarbon ABB fill SIlicone oil for high temperature Silicone polymer for low temperature Mineral oil (FDA approved) Vegetable oil (FDA approved) Glycerin-water (FDA approved) (Note 1) (Note 1) (Note 2) (Note 2) (Note 2) S N D K H C W A B Gasket - 14th character None PTFE with Silica filter Graphite Note 1: Suitable for oxygen service Note 2: Suitable for food application TM Hastelloy is a Cabot Corporation trademark TM Galden is a Montefluos trademark TM Halocarbon is a Halocarbon Products Co. trademark 1 6 7 9 2600T Pressure Transmitters Models S264 SS/S264_3 S264F Model Flanged Extended and Flush Diaphragm Remote Seal The extended and flush diaphragm remote seal is designed to connect to ANSI or DIN flanged pipe fitting. For liquid level measurement installations the seal connects to an ANSI or DIN flanged tank nozzle (Schedule 40). F F G E B D E A C D C B Capillary to Instrument A Capillary to Instrument G 158 (6.22) 2in, 4in or 6in Insertion length is available 158 (6.22) Flanged Extended Diaphragm Seal Flanged Flush Diaphragm Seal Dimensions mm (in) Size/Rating 2in ANSI CL 150 2in ANSI CL 300 2in ANSI CL 600 2in ANSI CL 900 3in ANSI CL 150 3in ANSI CL 300 3in ANSI CL 600 3in ANSI CL 900 4in ANSI CL 150 4in ANSI CL 300 DN50 DIN PN16 DN50 DIN PN40 DN50 DIN PN64 DN50 DIN PN100 DN50 DIN PN160 DN80 DIN PN16 DN80 DIN PN40 DN80 DIN PN64 DN80 DIN PN100 DN80 DIN PN160 DN100 DIN PN16 DN100 DIN PN40 10 A (dia) 60 60 60 60 89 89 89 89 89 89 60 60 60 60 60 89 89 89 89 89 89 89 flush (2.36) (2.36) (2.36) (2.36) (3.5) (3.5) (3.5) (3.5) (3.5) (3.5) (2.36) (2.36) (2.36) (2.36) (2.36) (3.5) (3.5) (3.5) (3.5) (3.5) (3.5) (3.5) extended 48 (1.9) 48 (1.9) NA NA 72 (2.83) 72 (2.83) NA NA 94 (3.7) 94 (3.7) 48 (1.9) 48 (1.9) NA NA NA 72 (2.83) 72 (2.83) NA NA NA 94 (3.7) 94 (3.7) B (dia) C (dia) D (dia) 92.1 (3.62) 92.1 (3.62) 92.1 (3.62) 92.1 (3.62) 127 (5) 127 (5) 127 (5) 127 (5) 157.2 (6.2) 157.2 (6.2) 102 (4.02) 102 (4.02) 102 (4.02) 102 (4.02) 102 (4.02) 138 (5.43) 138 (5.43) 138 (5.43) 138 (5.43) 138 (5.43) 158 (6.22) 162 (6.38) 120.5 (4.74) 127 (5) 127 (5) 165 (6.5) 152.5 (6) 168.5 (6.63) 168.5 (6.63) 190.5 (7.5) 190.5 (7.5) 200.2 (7.88) 125 (4.92) 125 (4.92) 135 (5.31) 145 (5.71) 145 (5.71) 160 (6.3) 160 (6.3) 170 (6.7) 180 (7.08) 180 (7.08) 180 (7.08) 190 (7.48) 152.5 (6) 165 (6.5) 165 (6.5) 216 (8.5) 190.5 (7.5) 210 (8.26) 210 (8.26) 241 (9.48) 228.6 (9) 254 (10) 165 (6.5) 165 (6.5) 180 (7.08) 195 (7.67) 195 (7.67) 200 (7.87) 200 (7.87) 215 (8.46) 230 (9.05) 230 (9.05) 220 (8.66) 235 (9.25) 20 20 20 26 20 22 22 26 20 22 18 18 22 26 26 18 18 22 26 26 18 22 E (dia) F (0.79) (0.79) (0.79) (1.02) (0.79) (0.86) (0.86) (1.02) (0.79) (0.86) (0.71) (0.71) (0.86) (1.02) (1.02) (0.71) (0.71) (0.86) (1.02) (1.02) (0.71) (0.86) 19.5 (0.77) 22.5 (0.88) 25.5 (1) 38.5 (1.51) 24 (0.94) 28.5 (1.12) 32 (1.26) 38.5 (1.51) 24 (0.94) 32 (1.26) 20 (0.79) 20 (0.79) 26 (1.02) 28 (1.1) 30 (1.18) 20 (0.79) 24 (0.94) 28 (1.1) 32 (1.26) 36 (1.42) 20 (0.79) 24 (0.94) G 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 (0.37) (0.37) (0.37) (0.37) (0.37) (0.37) (0.37) (0.37) (0.37) (0.37) (0.37) (0.37) (0.37) (0.37) (0.37) (0.37) (0.37) (0.37) (0.37) (0.37) (0.37) (0.37) N of holes 4 8 8 8 4 8 8 8 8 8 4 4 4 4 4 8 8 8 8 8 8 8 2600T Pressure Transmitters Models S264 SS/S264_3 Gasket seat finish Maximum Working Pressure (20 to 120C; 68 to 248F) ANSI CL 150 : 2 MPa, 20 bar, 290 psi smooth (RF or DIN): ANSI CL 300 : 5 MPa, 50 bar, 725 psi serrated (RF): 3.2 to 6.3m (125 to 250AARH) 0.8m (32AARH) ANSI CL 600 : 10 MPa, 100 bar, 1450 psi Form C (DIN 2526): 160RZ ANSI CL 900 : 16 MPa, 160 bar, 2320 psi Form E (DIN 2526): 16RZ DIN PN 16 : 1.6 MPa, 16 bar, 230 psi DIN PN 40 : 4 MPa, 40 bar, 580 psi Temperature effect DIN PN 64 : 6.4 MPa, 64 bar, 930 psi The following table shows the temperature effect for 20K (36F) change, detailed separately for DIN PN100 : 10 MPa, 100 bar, 1450 psi DIN PN160 : 16 MPa, 160 bar, 2320 psi Vacuum Service Full vacuum subject to fill fluid limits. Refer to table A. Minimum pressure with tantalum diaphragm is 1kPa abs, 10mbar abs, 0.15psia. Process Temperature Limits a) the seal (one element) b) the capillary per meter c) the system (transmitter sensor when combined with a seal of specific size/type) referred to silicone oil (DC 200) filling and AISI 316 L ss diaphragm materials. For filling different from silicone oil (DC200) the errors can be multiplied by the thermal expansion coefficient listed in the fill fluid characteristics table. Same as fill fluid limits. Refer to table A. 260C (500F) for Tantalum diaphragm. THE ERRORS IN TABLE CAN BE CONSIDERED DIVIDED BY 4 FOR TRANSMITTERS USING SAME REMOTE SEAL ON THE TWO SIDES 204C (400F) for use with Teflon anti-stick coating. Flanged Extended Diaphragm Remote Seal Flanged Extended Diaphragm Seal Size Seal error 1m Capillary Error System (Sensor) Error 2in / DN 50 0.3kPa, 3mbar, 1.2inH2O 0.1kPa, 1mbar, 0.4inH2O 0.3kPa, 3mbar, 1.2nH2O 3in / DN 80 0.15kPa, 1.5mbar, 0.6inH2O 0.08kPa, 0.8mbar, 0.32inH2O 0.07kPa, 0.7mbar, 0.28inH2O 4in / DN 100 0.09kPa, 0.9mbar, 0.36inH2O 0.03kPa, 0.3mbar, 0.12inH2O 0.03kPa, 0.3mbar, 0.12inH2O Flanged Flush Diaphragm Remote Seal Flanged Flush Diaphragm Seal Size Seal error 1m Capillary Error System (Sensor) Error 2in / DN 50 0.29kPa, 2.9mbar, 1.16inH2O 0.07kPa, 0.7mbar, 0.28inH2O 0.2kPa, 2mbar, 0.8inH2O 3in / DN 80 0.09kPa, 0.9mbar, 0.36inH2O 0.03kPa, 0.3mbar, 0.12inH2O 0.03kPa, 0.3mbar, 0.12inH2O 4in / DN 100 0.09kPa, 0.9mbar, 0.36inH2O 0.03kPa, 0.3mbar, 0.12inH2O 0.03kPa, 0.3mbar, 0.12inH2O 11 2600T Pressure Transmitters Models S264 SS/S264_3 BASIC ORDERING INFORMATION model S264F Flanged Remote Seal (flush and extended) Select one character or set of characters from each category and specify complete catalog number. BASE MODEL - 1st to 5th characters S 2 6 4 F X X X X X X X Flanged Remote seal (flush and extended) Transmitter side of connection - 6th character High side Low side Mounting flange - 7th character Rotating Size - 8th character H L R A D G J B 1 E H K C F M P R W N L Q S Y T U 2in ANSI CL 150 ANSI CL 300 2in 2in ANSI CL 600 2in ANSI CL 900 ANSI CL 150 3in 3in food design ANSI CL 150 3in ANSI CL 300 ANSI CL 600 3in 3in ANSI CL 900 4in ANSI CL 150 ANSI CL 300 4in DN50 DIN PN 16/40 DIN PN 64 DN50 DIN PN 100 DN50 DN50 DIN PN 160 DIN PN 16 DN80 DIN PN 40 DN80 DN80 DIN PN 64 DIN PN 100 DN80 DN80 DIN PN 160 DIN PN 16 DN100 DIN PN 40 DN100 Mounting flange/Seat form (seal) - 9th character Carbon steel Carbon steel Carbon steel Carbon steel AISI 316 ss AISI 316 ss AISI 316 ss AISI 316 ss Form RF (raised face) - serrated finish Form RF (raised face) - smooth finish DIN 2526 - Form C/E - serrated finish DIN 2526 - Form C/E - smooth finish Form RF (raised face) - serrated finish Form RF (raised face) - smooth finish DIN 2526 - Form C/E - serrated finish DIN 2526 - Form C/E - smooth finish (Notes 1, 3) (Notes 1, 3) (Notes 2, 3) (Notes 2, 3) (Notes 1, 3) (Note 1) (Notes 2, 3) (Notes 2, 3) A B G P D E L Q Extensions length and material - 10th character Flush (see next for diaphragm material) 50mm (2in) 50mm (2in ) 100mm (4in) 100mm (4in) 150mm (6in) 150mm (6in) AISI 316 L ss Hastelloy 276TM AISI 316 L ss Hastelloy 276TM AISI 316 L ss Hastelloy 276TM F 1 2 3 4 5 6 (Notes 3, 4) (Notes 3, 4, 6) (Notes 3, 4) (Notes 3, 4, 6) (Notes 3, 4) (Notes 3, 4, 6) Diaphragm material (seal) - 11th character AISI 316 L ss Hastelloy C276TM Tantalum AISI 316 L ss with anti-stick coating Hastelloy C276TMwith anti-stick coating AISI 316 L ss with anti-corrosion and anti-stick coating (Note 5) (Note 6) (Notes 6, 7) (Notes 5, 6, 8) (Notes 6, 8) (Notes 5, 6) NACE NACE NACE NACE NACE S H T K Y W Capillary protection - 12th character AISI 316 ss armour AISI 316 ss armour with PVC protective cover 12 (RECOMMENDED FOR HIGH TEMPERATURE) A B 2600T Pressure Transmitters Models S264 SS/S264_3 X BASIC ORDERING INFORMATION S264F X X th Capillary length m (feet) - 13 character 1 (3) 1.5 (5) 2 (7) 2.5 (8) 3 (10) 3.5 (12) 4 (13) 4.5 (15) 5 (17) 5.5 (18) 6 (20) 6.5 (22) 7 (23.5) 7.5 (25) 8 (27) 9 (30) 10 (33) 12 (40) 14 (47) 16 (53) A B C D E F G H J K L M N P Q R S T U V Fill fluid - 14th character Silicone oil Inert fluid - Galden Inert fluid - Halocarbon ABB fill SIlicone oil for high temperature Silicone polymer for low temperature Mineral oil (FDA approved) Vegetable oil (FDA approved) Glycerin-water (FDA approved) (Notes 3, 9) (Notes 3, 9) (Note 3) (Note 3) (Note 3) (Note 10) (Note 10) (Note 10) S N D K H C W A B Certification - 15th character None Zone "0" protection (Note 11) Note 1: Not available with DIN mounting flange code M, P, R, W, N, L, Q, S, Y, T, U Note 2: Not available with ANSI mounting flange code A, D, G, J, B, E, H, K, C, F Note 3: Not available with 3in ANSI CL150 food design size code 1 Note 4: Not available with ANSI CL 600 and ANSI CL 900 mounting flange rating code G, J, H, K and with DIN PN64, PN100, and PN160 mounting flange code P, R, W, Q, S, Y Note 5: Not available with Hastelloy C276 extension code 2, 4, 6 Note 6: Not available with serrated seat finish code A, G, D, L Note 7: Not available with extension code 1, 2, 3, 4, 5, 6 Note 8: Not available with 2in, DN50, DN80, DN100 mounting flange code A, D, G, J, M, P, R, W, N, L, Q, S, Y, T, U Note 9: Suitable for oxygen service 1 2 Note 10: Suitable for food application Note 11: Not available with Diaphragm material code K, Y TM Hastelloy is a Cabot Corporation trademark TM Galden is a Montefluos trademark TM Halocarbon is a Halocarbon Products Co. trademark 13 2600T Pressure Transmitters Models S264 SS/S264_3 S264T Model Off-line Threaded Connection Remote Seal The off-line threaded connection remote seals are designed to connect directly to a process pipe via the NPT connection in the lower housing . These elements are available with a flushing connection in the lower housing. D 134 (5.3) Dimensions mm (in) D (dia) Q 1 /4in NPT 109.2 (4.3) 53.3 (2.1) 1 /2in NPT 109.2 (4.3) 53.3 (2.1) 1in NPT 109.2 (4.3) 63.5 (2.5) 1 1/2in NPT 109.2 (4.3) 63.5 (2.5) Q 1/4in NPT-f Flushing connection (option) Size Lower Housing Gasket Diaphragm Process Connection Maximum Working Pressure (20 to 120C; 68 to 248F) Temperature effect 16 MPa, 160 bar, 2320 psi @ 38C (100F). The following table shows the temperature effect for 20K (36F) change, detailed separately for Vacuum Service Full vacuum subject to fill fluid limits. Refer to table A. Minimum pressure with tantalum diaphragm is 1kPa abs, 10mbar abs, 0.15psia. Process Temperature Limits Same as fill fluid limits but not greater than 200C (392F) due to gasket material. Refer to table A. -20C (-4F) minimum with Viton gasket a) the seal (one element) b) the capillary per meter c) the system (transmitter sensor when combined with a seal of specific size/type) referred to silicone oil (DC 200) filling and AISI 316 L ss diaphragm materials. For filling different from silicone oil (DC200) the errors can be multiplied by the thermal expansion coefficient listed in the fill fluid characteristics table. THE ERRORS IN TABLE CAN BE CONSIDERED DIVIDED BY 4 FOR TRANSMITTERS USING SAME REMOTE SEAL ON THE TWO SIDES Off-Line Threaded Seal Size 2 1/2in 14 Seal error 0.32kPa, 3.2mbar, 1.28inH2O 1m Capillary Error 0.18kPa, 1.8mbar, 0.72inH2O System (Sensor) Error 0.15kPa, 1.5mbar, 0.6inH2O 2600T Pressure Transmitters Models S264 SS/S264_3 BASIC ORDERING INFORMATION model S264T Off-Line Threaded Connection Remote Seal Select one character or set of characters from each category and specify complete catalog number. BASE MODEL - 1st to 5th characters S 2 6 4 T X X X X X X X X X X Off-line threaded remote seal Transmitter side of connection - 6th character High side Low side Size - 7th character 1 /4in NPT-f 1 /2in NPT-f 1in NPT-f 1 1/2in NPT-f Bolts - 8th character H L 1 2 3 4 AISI 316 L ss Carbon steel Alloy steel Flange material - 9th character 1 2 3 AISI 316 ss Hastelloy C276TM 1 2 Diaphragm material - 10th character AISI 316 L ss Hastelloy C276TM Tantalum S H T Capillary protection - 11th character AISI 316 ss armour AISI 316 ss armour with PVC protective cover (RECOMMENDED FOR HIGH TEMPERATURE) A B Capillary length m (feet) - 12th character 1 (3) 1.5 (5) 2 (7) 2.5 (8) 3 (10) 3.5 (12) 4 (13) 4.5 (15) 5 (17) 5.5 (18) 6 (20) 6.5 (22) 7 (23.5) 7.5 (25) 8 (27) 9 (30) A B C D E F G H J K L M N P Q R Fill fluid - 13th character Silicone oil Inert fluid - Galden Inert fluid - Halocarbon ABB fill SIlicone oil for high temperature Silicone polymer for low temperature Mineral oil (FDA approved) Vegetable oil (FDA approved) Glycerin-water (FDA approved) (Note 1) (Note 1) (Note 2) (Note 2) (Note 2) S N D K H C W A B Flushing connections - 14th character Not required Provided (Note 3) 1 Q Gasket - 15th character PTFE Viton TM 2 3 Note 1: Suitable for oxygen service Note 2: Suitable for food application Note 3: Not available with Size code 4 TM Hastelloy is a Cabot Corporation trademark TM Viton is a Dupont de Nemour trademark TM Galden is a Montefluos trademark TM Halocarbon is a Halocarbon Products Co. trademark 15 2600T Pressure Transmitters Models S264 SS/S264_3 S264M Model Off-line Flanged Connection Remote Seal The off-line threaded connection remote seals are designed to connect directly to ANSI or DIN flanged tank nozzles. These elements are available with a flushing connection in the lower housing, selectable on request in the ordering code. 63.5 (2.5) 134 (5.3) dia 110 (4.33) C F 1/4in NPT-f Flushing connection (option) Gasket Seat finish E D B A Dimensions mm (in) Connection Size 1in 1 1/2in DN 25 DN 40 Rating ANSI CL 150 ANSI CL 300 ANSI CL 150 ANSI CL 300 DIN PN 16-40 DIN PN 16-40 A (dia) B (dia) 110 (4.33) 124 (4.88) 127 (5) 155 (6.1) 115 (4.52) 150 (5.9) 79.4 (3.12) 88.9 (3.5) 98.4 (3.87) 114.3 (4.5) 85 (3.34) 110 (4.33) C (4 studs) Length Thread 39 (1.53) 1/2in - 13 UNC 51 (2) 5/8in - 11 UNC 39 (1.53) 1/2in - 13 UNC 57 (2.24) 3/4in - 10 UNC 42 (1.65) M12 48 (1.89) M16 Maximum Working Pressure (20 to 120C; 68 to 248F) D (dia) E (dia) F 50.8 (2) 26.7 (1.05) 1.6 (0.06) 73 (2.87) 41 (1.61) 1.6 (0.06) 68 (2.67) 88 (3.46) 28.5 (1.12) 43.1 (1.69) 2 (0.07) 3 (0.12) Temperature effect ANSI CL 150 : 2 MPa, 20 bar, 290 psi ANSI CL 300 : 5 MPa, 50 bar, 725 psi The following table shows the temperature effect for 20K (36F) change, detailed separately for DIN PN 16-40 : 4 MPa, 40 bar, 580 psi a) Vacuum Service Full vacuum subject to fill fluid limits. Refer to table A. Minimum pressure with tantalum diaphragm is 1kPa abs, 10mbar abs, 0.15psia. Process Temperature Limits Same as fill fluid limits but not greater than 200C (392F) due to gasket material. Refer to table A. -20C (-4F) minimum with Viton gasket the seal (one element) b) the capillary per meter c) the system (transmitter sensor when combined with a seal of specific size/type) referred to silicone oil (DC 200) filling and AISI 316 L ss diaphragm materials. For filling different from silicone oil (DC200) the errors can be multiplied by the thermal expansion coefficient listed in the fill fluid characteristics table. THE ERRORS IN TABLE CAN BE CONSIDERED DIVIDED BY 4 FOR TRANSMITTERS USING SAME REMOTE SEAL ON THE TWO SIDES. Gasket seat finish serrated (RF): 3.2 to 6.3m (125 to 250AARH) Form C (DIN 2526): 160RZ Off-Line Flanged Seal Size 2 1/2in 16 Seal error 0.32kPa, 3.2mbar, 1.28inH2O 1m Capillary Error 0.18kPa, 1.8mbar, 0.72inH2O System (Sensor) Error 0.15kPa, 1.5mbar, 0.6inH2O 2600T Pressure Transmitters Models S264 SS/S264_3 BASIC ORDERING INFORMATION model S264M Off-line Flanged Connection Remote Seal Select one character or set of characters from each category and specify complete catalog number. BASE MODEL - 1st to 5th characters S 2 6 4 M X X X X X X X X X X Off-line mini-flanged remote seal Transmitter side of connection - 6th character High side Low side Mounting flange- 7th character Integral with seal Size/Mounting flange rating - 8th character 1in 1in 1 1/2in 1 1/2in DN25 DN40 Mounting flange/Seat form AISI 316 ss AISI 316 ss Hastelloy C276TM Hastelloy C276TM H L P ANSI CL 150 ANSI CL 300 ANSI CL 150 ANSI CL 300 DIN PN 16/40 DIN PN 16/40 (seal) - 9th character A C B D M N Form RF (raised face) - serrated finish DIN 2526 - Form C - serrated finish Form RF (raised face) - serrated finish DIN 2526 - Form C - serrated finish (Note (Note (Note (Note 1) 2) 1) 2) D L U V Diaphragm material (seal) - 10th character AISI 316 L ss Hastelloy C276TM Tantalum S H T Capillary protection - 11th character AISI 316 ss armour AISI 316 ss armour with PVC protective cover (RECOMMENDED FOR HIGH TEMPERATURE) A B Capillary length m (feet) - 12th character 1 (3) 1.5 (5) 2 (7) 2.5 (8) 3 (10) 3.5 (12) 4 (13) 4.5 (15) 5 (17) 5.5 (18) 6 (20) 6.5 (22) 7 (23.5) 7.5 (25) 8 (27) 9 (30) A B C D E F G H J K L M N P Q R Fill fluid - 13th character Silicone oil Inert fluid - Galden Inert fluid - Halocarbon ABB fill SIlicone oil for high temperature Silicone polymer for low temperature Mineral oil (FDA approved) Vegetable oil (FDA approved) Glycerin-water (FDA approved) S N D K H C W A B (Note 3) (Note 3) (Note 4) (Note 4) (Note 4) Flushing connections - 14th character Not required Provided 1 Q Gasket - 15th character PTFE Viton TM 2 3 Note 1: Not available with DIN mounting flange code M, N TM Hastelloy is a Cabot Corporation trademark Note 2: Not available with ANSI mounting flange code A, B, C, D TM Viton is a Dupont de Nemour trademark Note 3: Suitable for oxygen service TM Galden is a Montefluos trademark Note 4: Suitable for food application TM Halocarbon is a Halocarbon Products Co. trademark 17 2600T Pressure Transmitters Models S264 SS/S264_3 S264U Model Union Connection Remote Seal (To be used only for gauge pressure) The union connection remote seal are used exclusively for pressure measurement with gauge pressure transmitter. The seal is available with an optional weld bushing, or with an optional chemical tee flange.The remote seal with a weld bushing, includes a bushing which provides the mating surface for the seal element. The union connection seal with a chemical tee flange, is designed to connect to any process fitting which accepts a chemical tee seal element (refer to Chemical Tee Seal for more information). The union seal connects to the chemical tee flange which serves as an adaptor to permit connection of the union seal to a chemical tee type fitting. 25 (1) 120 (4.7) 12 (0.47) Chemical Tee Flange 134 (5.3) 29 (1.14) 16 (0.63) Union Connection 9 (0.35) 14 (0.55) 2 (0.08) Capillary to Instrument Capillary to instrument Union Connection Seal dia 127 (5) dia 96 (3.78) dia 42 (1.65) dia 51 (2) dia 42 (1.65) dia 41 (1.61) O-Ring Diaphragm Surface 54 (2.12) - 16N2 10 (0.39) Full Thread Union Connection Seal with chemical tee flange 5 (0.19) 8 Mounting Holes dia 8.7 (0.34) Equally Spaced on 111.125 (4.37) Bolt Circle 120 (4.7) 25 (1) Welding Bushing dia 42 (1.65) 4 (0.16) Union Connection Seal without weld bushing Capillary to instrument Diaphragm Surface Union Connection 57 (2.25) Union Connection Seal with weld bushing Maximum Working Pressure dia 89 (3.5) 5 (0.19) dia 42 (1.65) 45 Temperature effect Union Connection: 10.3 MPa, 103 bar, 1500 psi With Chemical Tee Flange : 2 MPa, 20 bar, 300 psi The following table shows the temperature effect for 20K (36F) change, detailed separately for a) Vacuum Service Full vacuum subject to fill fluid limits. Refer to table A. the seal (one element) b) the capillary per meter c) the system (transmitter sensor when combined with a seal of specific size/type) referred to silicone oil (DC 200) filling and AISI 316 L ss diaphragm materials. Process Temperature Limits Same as fill fluid limits. Refer to table A. 204C (400F) with silicone rubber O-ring For filling different from silicone oil (DC200) the errors can be multiplied by the thermal expansion coefficient listed in the fill fluid characteristics table. 260C (500F) with Teflon TFE O-ring Union Connection Seal Size 1 1/2in 18 Seal error 0.87kPa, 8.7mbar, 3.5inH2O 1m Capillary Error 0.3kPa, 3mbar, 1.2inH2O System (Sensor) Error 0.9kPa, 9mbar, 3.6inH2O 2600T Pressure Transmitters Models S264 SS/S264_3 BASIC ORDERING INFORMATION model S264U Union Connection Remote Seal Select one character or set of characters from each category and specify complete catalog number. BASE MODEL - 1st to 5th characters S 2 6 4 U X X X X X X X X Union connection remote seal (MUST BE ONE ONLY FOR EACH TRANSMITTER) Transmitter side of connection - 6th character High side Low side Size - 7th character 1 1/2in Diaphragm material (seal) - 8th character H L L AISI 316 L ss Hastelloy C 276TM NACE S H Capillary protection - 9th character AISI 316 ss armour AISI 316 ss armour with PVC protective cover (RECOMMENDED FOR HIGH TEMPERATURE) A B Capillary length m (feet) - 10th character 1 (3) 1.5 (5) 2 (7) 2.5 (8) 3 (10) A B C D E Fill fluid - 11th character Silicone oil Inert fluid - Galden Inert fluid - Halocarbon ABB fill SIlicone oil for high temperature Silicone polymer for low temperature Mineral oil (FDA approved) Vegetable oil (FDA approved) Glycerin-water (FDA approved) (Note 1) (Note 1) (Note 2) (Note 2) (Note 2) S N D K H C W A B Options - 12th character None AISI 316 ss weld bushing Chemical tee flange 1 3 4 Gasket - 13th character Silicone rubber Teflon TFE Note 1: Suitable for oxygen service Note 2: Suitable for food application TM Hastelloy is a Cabot Corporation trademark TM Galden is a Montefluos trademark TM Halocarbon is a Halocarbon Products Co. trademark 5 8 19 2600T Pressure Transmitters Models S264 SS/S264_3 S264S Food and Sanitary Remote Seals 134 (5.3) C 20 (0.79) 134 (5.3) The Union Nut and Triclamp remote seals are designed for connection by Union Nut according to DIN 11851 F50 or F80 and 2 in, 3 in, 4 in Triclamp sanitary fittings. A variety of gaskets and clamp rings for the seals are available. B Triclamp Seal Union Nut Seal (to DIN 11851) Triclamp Union Nut F50 27 (1.06) A 2.85 (0.11) A B 2in F8 0 3i n 4i n A (dia) 68 (2.68) 100 (3.93) A (dia) 56.3 (2.2) 83 (3.26) 110.3 (4.34) B (RD) 78 (3.07) 110 (4.33) B (dia) 64 (2.5) 91 (3.58) 119 (4.68 C 16 (0.63) 19 (0.74) The Cherry Burrell remote seals are designed for connection to 2in, 3in or 4in Cherry Burrell I-Line sanitary fittings. A 4in V-band clamp is optionally available for the 4in variant. A E F G H B C D DIMENSIONS mm (in) Size A (dia) B (dia) C (dia) D (dia) E F G H 2in 67 (2.64) 56 (2.2) 42 (1.65) 57(2.24) 3.2 (0.13) 6.5 (0.26) 12.5 (0.49) 3 (0.12) 3 in 89 (3.86) 81 (3.19) 72.42 (2.85) 83.8 (3.3) 2.4 (0.09) 7.9 (0.31) 15 (0.59) 3 (0.12) 4in 124 (4.88) 111.25 (4.38) 72.42 (2.85) 109.3 (4.3) 2.4 (0.09 7.9 (0.31) 15 (0.59) 3 (0.12) 20 2600T Pressure Transmitters Models S264 SS/S264_3 The sanitary remote seal with flush diaphragm is designed to connect to a 4in sanitary tank spud. The tank spud and process gasket are available as options with the seal suitable V-band clamp is also available on request. NOTE: The tank spud required for connection of this seal element must be welded to the process vessel prior to connecting the seal, following arecommended welding and pressure testing procedure. dia 119 (4.68) 8 (0.31) for thin wall 13 (0.51) for thick wall 19.3 (0.75) 18.5 (0.72) dia 85.5 (3.36) dia 36 (1.41) dia 72 (2.83) dia 110 (4.33) dia 152.4 (6) The sanitary remote seal with extended diaphragm is designed to connect to a 4in sanitary tank spud. The tank spud and process gasket are available with the seal. NOTE: The tank spud required for connection of this seal element must be welded to the process vessel prior to connecting the seal. Refer to Installing Sanitary Tank Spuds for the spud mounting dimensions and a recommended welding and pressure testing procedure in the S264 instruction manual. dia 132.6 (5.22) Dimensions mm (in) Size 2in 53.3 (2.1) 4in 104.1 (4.1) 6in 154.9 (6.1) 5.6 (0.22) A 10 (0.39) A dia 72 (2.83) dia 100 (3.93) dia 152 (5.98) 21 2600T Pressure Transmitters Models S264 SS/S264_3 The sanitary aseptic remote seal is designed to connect to a 4in sanitary fitting: either an aseptic tank spud or a 4in Cherry Burrell aseptic ferrule. The tank spud, gaskets and V-band clamp are available option with the seal element. NOTE: The tank spud or ferrule required for connection of this seal element must be welded to the process vessel prior to connecting the element, following recommended welding and pressure testing procedure. Weld the Cherry Burrell ferrule to the process vessel in accordance with manufacturers recommandations. dia 119 (4.68) dia 124 (4.88) dia 105 (4.13) dia 111.25 (4.37) dia 85.5 (3.36) dia 82.6 (3.25) 3 (0.11) 15 (0.59) 11.2 (0.75) dia 72.4 (2.85) 7.9 (0.31) 2.4 (0.09) 19.3 (0.75) 4.2 (0.16) dia 79.6 (3.13) dia 62 (2.44) 2 holes 1/8in-27NPT (180 symmetrical for steam connection) 4in Cherry Burrell Aseptic 4in Aseptic Flanged Connection Vacuum Service Maximum Working Pressure @ 20C (68F) Full vacuum subject to fill fluid limits. Refer to table A. 2 in Triclamp : 3.8 MPa, 38 bar, 550 psi 3 in Triclamp : 2.4 MPa, 24 bar, 350 psi Temperature effect 4 in Triclamp : 1.7 MPa, 17 bar, 250 psi F50/F80 Union nut : 2.5 MPa, 25 bar, 360 psi The following table shows the temperature effect for 20K (36F) change, detailed separately for Cherry Burrell: 1.9MPa, 19bar, 275psi a) 4in Sanitary flush or extended or aseptic: 1.9MPa, 19bar, 275psi b) the capillary per meter 4in V-band clamp option: 1MPa, 10bar, 145psi c) the system (transmitter sensor when combined with a seal of specific size/type) 4in schedule 5 V-band clamp option: 0.7MPa, 7bar, 100psi @ 21C. Process Temperature Limits the seal (one element) referred to silicone oil (DC 200) filling and AISI 316 L ss diaphragm materials. For filling different from silicone oil (DC200) the errors can be multiplied by the thermal expansion coefficient listed in the fill fluid characteristics table. Same as fill fluid limits. Refer to table A. Process Gasket Temperature Limits Buna: -40 to 121C (-40 to 250F) THE ERRORS IN TABLE CAN BE CONSIDERED DIVIDED BY 4 FOR TRANSMITTERS USING SAME REMOTE SEAL ON THE TWO SIDES Viton: 2 to 177C (35 to 350F) Ethylene Propylene: 149C (300F) Union Nut, Triclamp, Cherry Burrell, Sanitary and Aseptic Seal Size Seal error 1m Capillary Error System (Sensor) Error 2in / F50 0.7kPa, 7mbar, 2.8nH2O 0.42kPa, 4.2mbar, 1.7inH2O 1.4kPa, 14mbar, 5.6inH2O 3in / F80 0.06kPa, 0.6mbar, 0.24inH2O 0.03kPa, 0.3mbar, 0.12inH2O 0.03kPa, 0.3mbar, 0.12inH2O 4in 0.06kPa, 0.6mbar, 0.24inH2O 0.03kPa, 0.3mbar, 0.12inH2O 0.03kPa, 0.3mbar, 0.12inH2O 22 2600T Pressure Transmitters Models S264 SS/S264_3 BASIC ORDERING INFORMATION model S264S Food and Sanitary Remote Seals Select one character or set of characters from each category and specify complete catalog number. BASE MODEL - 1st to 5th characters S 2 6 4 S X X X X X X X X Food and Sanitary remote seals Transmitter side of connection - 6th character High side Low side Mounting connection - 7th character Union nut DIN 11851 - F50 Union nut DIN 11851 - F80 2in Triclamp 3in Triclamp 4in Triclamp 2in Cherry Burrell 3in Cherry Burrell 4in Cherry Burrell 4in Sanitary flush diaphragm 4in Sanitary extended (2in) diaphragm 4in Sanitary extended (4in) diaphragm 4in Sanitary extended (6in) diaphragm 4in Cherry Burrell aseptic 4in aseptic flanged connection Seal diaphragm material - 8th character H L A B F G H L M N P Q R S W J AISI 316 L ss S Capillary protection - 9th character AISI 316 ss armour AISI 316 ss armour with PVC protective cover (RECOMMENDED FOR HIGH TEMPERATURE) A B Capillary length m (feet) - 10th character 1 (3) 1.5 (5) 2 (7) 2.5 (8) 3 (10) 3.5 (12) 4 (13) 4.5 (15) 5 (17) 5.5 (18) 6 (20) 6.5 (22) 7 (23.5) 7.5 (25) 8 (27) 9 (30) 10 (33) A B C D E F G H J K L M N P Q R S Fill fluid - 11th character Silicone oil Mineral oil (FDA approved) Vegetable oil (FDA approved) Glycerin-water (FDA approved) (Note 1) (Note 1) (Note 1) S W A B Clamp/Fittings - 12th character None 2in V-band Clamp (for 2in Triclamp) 3in V-band Clamp (for 3in Triclamp) 4in V-band Clamp (for 4in Triclamp, 4in Cherry Burrell, 4in Sanitary flush and 4in aseptic flanged) 4in Tank spud, tank wall up to 4.7mm (0.18) (for 4in Sanitary flush seal) 4in Tank spud, tank wall up to 9.5mm (0.37) (for 4in Sanitary flush seal) 4in schedule 5 V-band clamp (for 4in Sanitary extended seal) Tank spud for 2in extension (for 4in Sanitary extended 2in seal) Tank spud for 4in extension (for 4in Sanitary extended 4in seal) Tank spud for 6in extension (for 4in Sanitary extended 6in seal) Aseptic tank spud (for 4in aseptic flanged seal) 1 A B C D E F G H J P Gasket - 13th character None Ethylene propylene gasket DN100 (for 4in Sanitary extended seal) Ethylene propylene gasket DN50 (for F50 Union nut seal) Ethylene propylene gasket DN80 (for F80 Union nut seal) VitonTM gasket (for 4in sanitary flush and aseptic flanged seal) Buna gasket (for 4in sanitary flush and aseptic flanged seal) Note 1: TM 1 A C D 3 4 Suitable for food application Viton is a Dupont de Nemour trademark 23 2600T Pressure Transmitters Models S264 SS/S264_3 S264P Remote seal(s) for Urea Service dia 155 (6.10) dia 209.6 (8.25) 131 (5.16) no. 8 holes dia 22.2 (0.87) 3.5 (0.14) 6.4 (0.25) 40.3 (1.59) no. 4 holes dia 25.4 (1) 45 (1.77) 31.8 (1.25) ~15 (0.59) dia 168.3 (6.63) 2 (0.07) ANSI B2.1 NPS dia 37.5 (1.47) 69 (2.71) 69 or 94 (2.71 or 3.7) dia 53 (2.08) dia 60 (2.36) dia 127 (5) dia 110 (4.33) Flange ANSI 600, 3in Threaded Flange ANSI 2500, 2in Maximum Working Pressure @ 20C (68F) Temperature effect 3in, ANSI 600 flange: - 8 MPa, 80 bar, 1160 psi The following table shows the temperature effect for 20K (36F) change, detailed separately for 2in ANSI 2500 threaded flange: a) - 32 MPa, 320 bar, 4640 psi b) the capillary per meter c) the system (transmitter sensor when combined with a seal of specific size/type) Vacuum Service Full vacuum subject to fill fluid limits. Refer to table A. Process Temperature Limits Same as fill fluid limits. Refer to table A. the seal (one element) referred to silicone oil (DC 200) filling and AISI 316 L ss diaphragm materials. For filling different from silicone oil (DC200) the errors can be multiplied by the thermal expansion coefficient listed in the fill fluid characteristics table. THE ERRORS IN TABLE CAN BE CONSIDERED DIVIDED BY 4 FOR TRANSMITTERS USING SAME REMOTE SEAL ON THE TWO SIDES Urea Service Flanged Seal Size Seal error 1m Capillary Error System (Sensor) Error 1 1/2in 1.4kPa, 14mbar, 5.6inH2O 0.56kPa, 5.6mbar, 2.24inH2O 1.8kPa, 18mbar, 7.2inH2O 2 1/2in 0.22kPa, 2.2mbar, 0.88inH2O 0.1kPa, 1mbar, 0.4inH2O 0.09kPa, 0.9mbar, 0.36inH2O 24 2600T Pressure Transmitters Models S264 SS/S264_3 BASIC ORDERING INFORMATION model S264P Remote Seal for Urea Service Select one character or set of characters from each category and specify complete catalog number. BASE MODEL - 1st to 5th characters S 2 6 4 P X X X X X X X X Remote seal for Urea Service Transmitter side of connection - 6th character High side Low side Size / Mounting rating / Material - 7th character 3in ANSI 600 RF 2in Threaded flange Extension length / Diameter - 8th character H L AISI 316 L ss Urea Grade Carbon steel 40.3mm (1.59in) 69mm (2.7in 40.3mm (1.59in) 94mm (3.71in) 131mm (5.16in) 37.5mm (1.47in) Diaphragm material (seal) - 9th character (Note 1) (Note 1) (Note 2) AISI 316 L ss Urea Grade H J R S T S th Capillary protection - 10 character AISI 316 ss armour AISI 316 ss armour with PVC protective cover (RECOMMENDED FOR HIGH TEMPERATURE) A B Capillary length m (feet) - 11th character 1 (3) 1.5 (5) 2 (7) 2.5 (8) 3 (10) 3.5 (12) 4 (13) 4.5 (15) 5 (17) 5.5 (18) 6 (20) A B C D E F G H J K L Fill fluid - 12th character Silicone oil SIlicone oil for high temeprature S H Option - 13th character None Huey test Note 1: Not available with Size/Mounting flange code J Note 2: Not available with Size/Mounting flange code H 1 3 25 2600T Pressure Transmitters Models S264 SS/S264_3 S264B Model Button Type Remote Seal (To be used only for gauge pressure) These remote seals are designed to connect directly to a process pipe via the NPT threaded connection or to match pipe fitting with an interface suitable for the provided mating flange. The button seals, due to their design, are dedicated for measurement with medium/ high calibrated span (2 MPa/20 bar/290 psi approx. or greater). 4 Holes equally spaced 33/64in dia on 2-1/8in dia Bolt Circle dia 35 (1-3/8) dia 34 (1-23/64) 2.3 (3/32) Thick Gasket dia 83 (3-1/4) Spacer Flange dia 24 (15/16) dia 23 (59/64) 13.49 (17/32) 6.35 (1/4) 19 (3/4) 51 (2) 2 Holes 5/16-18NC-2 on 2-1/8in Dia Bolt Circle 146 (5-3/4) Flange 4 Holes equally spaced 17/32in dia on 2-1/2in dia Bolt Circle 2.3 (3/32) Thick Gasket dia 89 (3-1/2) dia 35 (1-3/8) dia 34 (1-23/64) 3 1/4in flange extended - type 91 dia 24 (15/16) dia 24 (15/16) dia 23 (59/64) dia 23 (59/64) 13.49 (17/32) Spacer 128 (5-1/32) 212 (8-11/32) Max 2 Holes 1/2-13NC-2 on 2-1/2in Dia Bolt Circle 3 1/2in flange extended - type 91 modified 1-1/2 16N-2 for Type 92 1-1/2 12FG for Type 92 modified 2.3 (3/32) Thick Gasket dia 24 (15/16) dia 23 (59/64) 25 (1) 6.35 (1/4) 13.49 (17/32) 38 (1-1/2) 19 (3/4) 1 1/2in threaded union type 92/92 modified 26 76 (3) 146 (5-3/4) 6.35 (1/4) 2600T Pressure Transmitters Models S264 SS/S264_3 138.11 (5-7/16) Capillary to instrument 28.58 (1-1/8) 2.3 (3/32) Thick Gasket 47.6 (1-7/8) 30.16 (1-3/16) dia 22.23 (7/8) 42.86 (1-11/16) dia 33.34 (1-5/16 ) dia 24 (15/16) dia 23 (59/64) 60.33 (2-3/8) 6.35 (1/4) 125.41 (4-15/16) 95.25 (3-3/4) 2 Holes dia 17.46 (11/16) 21.43 (27/32) 13.49 (17/32) Bracket - type 89 2.3 (3/32) Thick Gasket dia 24 (15/16) dia 23 (59/64) 13 (17/32) 52 (2-1/16) 78 (3-1/16) Universal- type 90 6.35 (1/4) 146 (5-3/4) Maximum Working Pressure (20 to 120C; 68 to 248F) Types 89, 90 and 92: 42MPa, 420bar, 6090psi Types 91: 35Mpa, 350bar, 5075psi Vacuum Service Full vacuum subject to fill fluid limits. Refer to table A. Process Temperature Limits Same as fill fluid limits. Refer to table A. Button Type Seal Size 1in Seal error 8kPa, 80mbar, 32inH2O Temperature effect The following table shows the temperature effect for 20K (36F) change, detailed separately for a) the seal (one element) b) the capillary per meter c) the system (transmitter sensor when combined with a seal of specific size/type) referred to silicone oil for high temperature filling and Hastelloy C276 diaphragm materials. 1m Capillary Error 1.8kPa, 18mbar, 72inH2O System (Sensor) Error 3.2kPa, 32mbar, 12.8inH2O 27 2600T Pressure Transmitters Models S264 SS/S264_3 BASIC ORDERING INFORMATION model S264B Button Type Remote Seal Select one character or set of characters from each category and specify complete catalog number. BASE MODEL - 1st to 5th characters S 2 6 4 B X X X X X X X X X Button type remote seal (MUST BE ONE ONLY FOR EACH TRANSMITTER) Transmitter side of connection - 6th character High side Low side Size - 7th character 1in Mounting connection type - 8th character H L M 3 1/4in flange extended - type 91 3 1/2in flange extended - type 91 modified 1 1/2in 16N-2 threaded union - type 92 1 1/2in 12NF threaded union - type 92 modified Bracket - type 89 Universal - type 90 Diaphragm material (seal) - 9th character A B C F D E Hastelloy C 276TM H Capillary protection - 10th character AISI 316 ss armour AISI 316 ss armour with PVC protective cover (RECOMMENDED FOR HIGH TEMPERATURE) A B Capillary length m (feet) - 11th character 1 (3) 1.5 (5) 2 (7) 2.5 (8) 3 (10) A B C D E Fill fluid - 12th character Silicone oil SIlicone oil for high temperature Mineral oil (FDA approved) (Note 1) S H W Option - 13th character Not required Jack out collar for seal removal for process (not for type 89) 1 2 Gasket - 14th character None Aluminium AISI 316 ss Note 1: TM 28 Only available with Bracket type 89 version and suitable for food application Hastelloy is a Cabot Corporation trademark 1 E F 2600T Pressure Transmitters Models S264 SS/S264_3 29 2600T Pressure Transmitters Models S264 30 SS/S264_3 2600T Pressure Transmitters Models S264 SS/S264_3 31 2600T Pressure Transmitters Model S264 SS/S264_3 The Company's policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. ABB has Sales & Customer Support expertise in over 100 countries worldwide Printed in Italy (02.04) www.abb.com/instrumentation SS/S264_3 (c) ABB 2004 ABB Ltd Howard Road, St. Neots Cambridgeshire, PE19 3EU UK Tel: +44(0)1480 475321 Fax: +44(0)1480 217948 ABB Inc. 125 E. County Line Road Warminster, PA 18974 USA Tel: +1 215 674 6000 Fax: +1 215 674 7183 ABB SACE spa Business Unit Instrumentation Via Statale 113 22016 Lenno (CO) Italy Tel: +39 0344 58111 Fax: +39 0344 56278