Economical, Limit Switch Style
Sensor with Plastic Body
Low cost
Wide operating voltages (10 to 30 VDC
and 90 to 250 VAC)
Directly switches AC loads up to
500 mA, DC loads up to 200 mA
Front, side or end sensing
DC reverse polarity protection
Operation indicators, all models
Ordering Information
Ty pe Sensing distance Sensing position Part number
NPN-NO PNP-NO
Unshielded 15 mm (0.59 in) End TL-YS15MC1-US TL-YS15MB1-US
Right TL-YS15MC14-US TL-YS15MB14-US
Left TL-YS15MC12-US TL-YS15MB12-US
Front TL-YS15MC11-US TL-YS15MB11-US
DC THREE-WIRE SENSORS
Limit Switch Style Inductive Prox TL-YS
Ty pe Sensing distance Sensing position Part number
SCR-NO SCR-NC
Unshielded 15 mm (0.59 in) End TL-YS15MY1-US TL-YS15MY2-US
Right TL-YS15MY14-US TL-YS15MY24-US
Left TL-YS15MY12-US TL-YS15MY22-US
Front TL-YS15MY11-US TL-YS15MY21-US
AC TWO-WIRE SENSORS
TL-YS TL-YS
2
Specifications
Part number TL-YS15MB1-US TL-YS15MY-US
TL-YS15MC1-US
Sensor Type Inductive
Body Style Limit Switch
Type Unshielded
Supply voltage 10 to 30 VDC 90 to 250 VAC, 50/60 Hz
Current consumption 15 mA max. 1.5 mA max. at 110 VAC
3.0 mA max. at 220 VAC
Detectable object type Metallic objects
Effective maximum detecting distance 15 mm (0.59 in) ±10%
(with standard target)
Usable detecting range 0 to 12 mm
(with standard target) (0 to 0.47 in)
Standard target size 40 x 40 x 1 mm
( mild steel, L x W x H) (1.58 x 1.58 x 0.04 in)
Differential travel 20% max. of effective maximum detecting distance
Control output Type SCR-NO (TL-YSMY1-US)
SCR-NC (TL-YSMY2-US)
Max. load 500 mA
Min. load 10 mA
Max. off-state See "Leakage Current Characteristics"
leakage current graph in
Engineering Data
section
Max. on-state See "Residual Load Voltage Characteristics"
voltage drop graph in
Engineering Data
section
Type NPN-NO (TL-YS15MC1-US
PNP-NO (TL-YS15MB1-US
Max. load 200 mA
Max. on-state voltage drop 1 VDC
Response frequency 40 Hz 20 Hz
Circuit protection Ouput short-circuit Not provided
DC power supply Provided
reverse polarity
Weld field immunity Not provided
RFI immunity Not provided
Indicators Target Present (red LED) Output operation (red LED)
Materials Housing PF (Phenolic)
Sensing face PF (Phenolic)
Mounting Back surface with four through holes
Connections Conduit
1
/
2
-14 NPT
Wire Plated steel screw terminals
Weight Approx. 180 g (6.4 oz)
Enclosure ratings UL 1
NEMA 1, 3, 4, 12, 13
IEC 144 IP66
Approvals UL Listed, File number E76675
CSA Certified, File number LR45951
Ambient operating temperature -25°C to 70°C (-13° to 158°F)
Vibration 10 to 55 Hz, 1.5 mm (0.06 in) double amplitude
Shock Approx. 50 G
AC
solid-
state
DC
solid-
state
TL-YS TL-YS
3
Operation
OUTPUT CIRCUIT DIAGRAM
DC Switching Type
TL-YS15MY

-US
NPN ouput
TL-YS15MC1
-US
PNP ouput
TL-YS15MB1
-US
TL-YS15C1
-US
TL-YS15B1
-US
NO
AC Switching Type
TL-YS15MY1
-US
NO
TL-YS15MY2
-US
NC
CONNECTIONS
DC Switching Types AC Switching Types
NPN ouput
TL-YS15MC1
-US
PNP ouput
TL-YS15MB1
-US TL-YS15MY

-US
NO or NC operation
TL-YS TL-YS
4
Engineering Data
OPERATING RANGE DETECTING DISTANCE
VS. SIZE OF TARGET DETECTING DISTANCE
VS. MATERIAL OF
TARGET
Material Detecting distances
Mild steel 15 mm (0.59 in)
Stainless steel 10 mm (0.39 in)
Brass 6.4 mm (0.25 in)
Aluminum 5 mm (0.20 in)
Copper 5 mm (0.20 in)
Note: Standard target size is 30 x 30 x
1 mm.
Note: If the target is a nonferrous metal, the oper ating distance of the proximity sensor decreases. Ho wever , with a piece of f oil measuring
about 0.01 mm (0.0004 in) in thickness, the detecting distance is equivalent to that with a ferrous metal. Note that the proximity
sensor cannot detect extremely thin evaporated films and non-conductive targets.
RESIDUAL LOAD VOLTAGE CHARACTERISTICS
AC Switching Types
TL-YS15MY

-US
110 VAC 220 VAC Note: When the current rating of the
load is less than 10 mA, false
operation may occur. This is
normal, and the problem can be
solved by installing a bleeder
resistor in parallel with the load.
Use the formulas given here to
calculate the power rating and
value of the resistor.
R < Vs (k) P > Vs2 (mW)
= 10 – i R
P : Wattage of bleeder resistor
i :Load current (mA)
Vs : Supply voltage (V)
TL-YS TL-YS
5
Dimensions
Unit: mm (inch)
LEAKAGE CURRENT CHARACTERISTICS
AC Switching Types
TL-YS15MY

-US
Note: Even when the proximity sensor is in the OFF state, a
very small amount of current flows to operate the internal
circuit of the sensor. Because of this leakage current, a
small voltage is generated in the load, which may
occasionally result in improper resetting of the load.
Before using the proximity sensor, confirm that this
voltage is less than the release voltage value of the load.
TL-YS TL-YS
6
Precautions
EFFECTS OF SURROUNDING METALS
When mounting a proximity sensor flush with a metallic panel,
be sure to provide a minimum distance as shown in the table
to prevent the sensor from being effected by metallic objects
other than the target.
MUTUAL INTERFERENCE
To prevent mutual interference, be sure to space the sensors
at a distance greater than that shown in the table below.
Drawing dimension Minimum distance
mm (inch)
A 45 (1.77)
B 45 (1.77)
Drawing dimension Minimum distance
mm (inch)
C 150 (5.91)
D 200 (7.87)
INFLUENCE OF PLATING
Metals with different types of plating effect the detecting
distance of inductive proximity sensors. The table at r ight
shows reference values for the percentage of the rated
detecting distance that may be expected by type of plating
materials.
Type of plating % of detecting distance (of
standard unplated iron target)
Zn 100
Cr 75
Ag 60
Ni 70
Cu 70
OMRON ELECTRONICS, INC. OMRON CANADA, INC.
One East Commerce Drive 885 Milner Avenue
Schaumburg, IL 60173 Scarborough, Ontario M1B 5V8
1-800-55-OMRON 416-286-6465
Cat. No. CEDSAX3 10/99 Specifications subject to change without notice. Printed in the U.S.A.
NOTE: DIMENSIONS ARE SHOWN IN MILLIMETERS. To convert millimeters to inches divide by 25.4.