SINGLE PHASE 8.0 AMP BRIDGE RECTIFIERS
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating 25 C ambient temperature uniess otherwies specified.
Single phase half wave, 60Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
TYPE NUMBER
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
.375"(9.5mm) Lead Length at Tc=50 C
Dimensions in inches and (millimeters)
FEATURES
Peak Forward Surge Current, 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Maximum Forward Voltage Drop per Bridge Element at 8.0A D.C.
Maximum DC Reverse Current Ta=25 C
at Rated DC Blocking Voltage Ta=100 C
RS801 RS802 RS803 RS804 RS805 RS806 RS807 UNITS
50 100 200 400 600 800 1000 V
50 100 200 400 600 800 1000 V
35 70 140 280 420 560 700
8.0
250
10
200
-65 +150
-65 +125
V
A
A
V
* Ideal for printed circuit board
* Low forward voltage
* Polarity: marked on body
* Mounting position: Any
RS801 THRU RS807
1.1
VOLTAGE RANGE
50 to 1000 Volts
CURRENT
RS-8
.700(17.8)
.660(16.8)
1.00
(25.4)
.078
(2.0)
MIN.
* Low leakage current
8.0 Amperes
.780(19.8)
.740(18.8)
.280(7.1)
.268(6.8)
.052(1.3)
.048(1.2)
.220(5.6)
.180(4.6)
.935(23.7)
.895(22.7)
DIA.
SPACING
AC +
.15FX.23L
(3.8FX5.7L)
HOLE THRU
Storage Temperature Range, TSTG
Operating Temperature Range, TJ
C
C
A
A
0.1
1.0
.01
10
50
RATING AND CHARACTERISTIC CURVES (RS801 THRU RS807)
FIG.4-TYPICAL REVERSE
CHARACTERISTICS
FIG.1-TYPICAL FORWARD CURRENT
AVERAGE FORWARD CURRENT,(A)
3.0
Single Phase
Half Wave 60Hz
Resistive Or Inductive Load
DERATING CURVE
0.1
1.0
.01
10
50
FIG.3-TYPICAL FORWARD
CHARACTERISTICS
INSTANTANEOUS FORWARD CURRENT,(A)
FORWARD VOLTAGE,(V)
Pulse Width 300us
1% Duty Cycle
0 .2 .4 .6 .8 1.0 1.2 1.4
3.0
0 25 50 75 100 125 150 175
Tj=100 C
Tj=25 C
Tj=25 C
FIG.2-MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
100
50
150
250
200
NUMBER OF CYCLES AT 60Hz
1 10 5 50 100
Tj=25 C 8.3ms Single Half
Sine Wave
JEDEC method
2
4
6
8
10
12
0
PEAK FORWARD SURGE CURRENT,(A)
20 40 60 80 100 120 140
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
0
0
CASE TEMPERATURE,( C)
REVERSE LEAKAGE CURRENT, ( A)