Rev. 08.15.11_141
LPT100-M Series
1 of 3
Embedded Power for
Business-Critical Continuity
LPT100-M Series
130 Watts
Special Features
• MedicalandITEsafeties
• Activepowerfactorcorrection
• 2”x4”footprint
• Lessthan1Uhigh
• EN61000-3-2compliant
• Remotesense
• Powerfail
• Adjustablemainoutput
• Built-inClassBEMIfilter
• Overvoltageprotection
• Overloadprotection
• Thermaloverloadprotection
• LPX50enclosurekitavailable
Total Power: 80 - 130 Watts
Input Voltage: 90-264Vac
# of Outputs: Triple
Electrical Specifications
Safety
Input
Inputrange: 90-264Vac;127-300Vdc
Frequency: 47-63Hz
Inrushcurrent: 50Amax.,coldstart@25°C
Efficiency: 82%typicalatfullload
EMI/RFI: FCCClassBconducted;CISPR22ClassBconducted;
EN55022ClassBconducted;VDE0878PT3ClassBconducted
Safetyground
leakagecurrent:
275µA@50/60Hz,264Vacinput
Output
Maximumpower: 80Wforconvection;
130Wwith200LFMforcedair
Adjustmentrange: Alloutputsadjustable:-20%,+10%,exceptfor+24VoutputonLPT104-M
whichwillbe-10%,+20%and3.3VoutputontheLPT101-M+10%,-15%
Hold-uptime: 10ms@130Wload,120Vacinput
Overloadprotection: Shortcircuitprotectiononalloutputs.Caseoverload
protected@110-160%aboveratingforV1&V2,150-250%forV3
Overvoltageprotection: 15-35%abovenominaloutput
LogicalControl
Powerfailure: ActiveLowTTLlogicsignalgoeshigh100-500msecaftermainoutput;it
goeslowatleast6msecbeforelossofregulation
Remotesense: Compensatesfor0.5Vleaddropmin.Willoperatewithoutremotesense
connected.Reverseconnectionprotected.
• TUV 60950,60601-1
• UL 60950,60601-1
• CSA 60950,60601-1
• NEMKO 60950,60601-1
• AUSTEL 60950,60601-1
• CB Certificate&report
• CE Mark(LVD)
Embedded Power for
Business-Critical Continuity
MechanicalDrawing
Rev. 08.15.11_141
LPT100-M Series
2 of 3
Operatingtemperature: 0°to50°Cambientderateeachoutputas2.5%perdegreefrom50°to70°C.-20°Cstartup
Storagetemperature: -40°Cto+85°C
Electromagnetic
susceptibility:
designedtomeetEN61000-4;
-2,-3,-4,-5,-6,-8,-11Level3
Humidity: Operating;non-condensing10%to90%RH,non-operating,non-condensing10%-95%
Vibration: IEC68-2-6tothelevelsofIEC721-3-2
MTBFcalculated: 583,000hoursatfullloadand25°Cambientconditions.230Vacinput,Bellcore
EnvironmentalSpecifications
SK3
SK2
PIN 1 (LIVE)
PIN 3 (NEUTRAL)
SK1
GND Output Voltage
Adjust Pots
Output Voltage
Adjust Pots
Mounting Hole
ø0.16” [4.0] 4 Places
Max. Screw Head
Diameter .22(5.6)
0.197” (5.0) Minimum
Standoff height
2.00”
(50.8)
3.73”
(94.6)
4.00”
(101.6)
1.72”
(43.8)
1.28”
(32.7)
0.10”
(2.5)
Rev. 08.15.11_141
LPT100-M Series
3 of 3
Embedded Power for
Business-Critical Continuity
OrderingInformation
Model
Number
Output
Voltage
Minimum
Load
Maximum Load
with Convection
Cooling
Maximum Load
with 30CFM
Forced Air
Peak
Load Regulation2
Ripple
P/P
(PARD)3
LPT101-M
+3.3V 0A 13A 18A 20A ±2% 50mV
+5V 0A 5A 9A 10A ±5% 50mV
+12V 0A 1A 2.3A 2.3A ±5% 120mV
LPT102-M
+5V 0A 13A 18A 20A ±2% 50mV
+12V 0A 5A 9A 10A ±5% 120mV
-12V 0A 1A 2A 2A ±5% 120mV
LPT103-M
+5V 0A 13A 18A 20A ±2% 50mV
+15V 0A 4A 7.2A 8A ±5% 150mV
-15V 0A 1A 1.5A 2A ±5% 150mV
LPT104-M
+5V 0A 13A 18A 20A ±2% 50mV
+24V 0A 1.5A 3A 3.5A ±7% 240mV
+12V 0A 1A 2.3A 2.3A ±5% 120mV
1. Peakcurrentlasting<15secondswithamaximum10%dutycycle.
2. At25°Cincludinginitialtolerance,linevoltage,loadcurrentsandoutputvoltagesadjustedtofactorysettings.
3. Peak-to-peakwith20mHzbandwidthand10µF(tantalumcapacitor)inparallelwitha0.1µFcapacitoratratedlinevoltage
andloadranges.
Notes:
1. Specificationssubjecttochangewithoutnotice.
2. Alldimensionsininches(mm),toleranceis±.02”.
3. mountingholesMH1,MH2,MH3shouldbegroundedfor
EMIpurpose
4. MountingMH1issafetygroundconnection
5. Specificationsareforconvectionratingatfactorysettings
at115Vacinput25°Cunlessotherwisestated.
6. Thispowersupplyrequiresmountingonmetalstandoffs
0.20”(5m)inheight.
7. ForDCinputanexternalDCsafetyratedfusemustbeused.
8. Warranty:2year
9. Weight:0.44lb./0.20kg
Americas
5810VanAllenWay
Carlsbad,CA92008
USA
Telephone:+17609304600
Facsimile: +17609300698
Europe (UK)
WaterfrontBusinessPark
MerryHill,Dudley
WestMidlands,DY51LX
UnitedKingdom
Telephone:+44(0)1384842211
Facsimile: +44(0)1384843355
Asia (HK)
14/F,LuPlaza
2WingYipStreet
KwunTong,Kowloon
HongKong
Telephone:+85221763333
Facsimile: +85221763888
Forglobalcontact,visit:
www.Emerson.com/EmbeddedPower
techsupport.embeddedpower
@emerson.com
Whileeveryprecautionhasbeentakentoensure
accuracyandcompletenessinthisliterature,Emerson
NetworkPowerassumesnoresponsibility,anddisclaims
allliabilityfordamagesresultingfromuseofthis
informationorforanyerrorsoromissions.
EmersonNetworkPowerandtheEmerson
NetworkPowerlogoaretrademarksand
servicemarksofEmersonElectricCo.
©2011EmersonElectricCo.
EmersonNetworkPower.com
EmbeddedComputing
Embedded Power
Monitoring
OutsidePlant
PowerSwitching&Controls
PrecisionCooling
Racks&IntegratedCabinets
Services
SurgeProtection
Emerson Network Power.
Thegloballeaderinenabling
business-criticalcontinuity.
ACPower
Connectivity
DCPower
PinAssignments
Connector LPT100-M
SK1 PIN1 Neutral
PIN3 Line
SK2 PIN1 V1out
PIN2 V1out
PIN3 GND
PIN4 GND
PIN5 GND
PIN6 GND
PIN7 V2out
PIN8 V3out
SK3 PIN1 Power Fail
PIN2 GND
PIN3 +RemoteSense
PIN4 -RemoteSense
MatingConnectors
ACInput(SK1): MolexP/N09-50-3031
PINS:08-52-0072
ACGround: MolexP/N01-90020001
DCOutput(SK2): JSTP/NVHR-8N
PINS:SVH-21T-P1.1
RemoteSense(SK3): MolexP/N51065-0400
PINS:50212-8100
EmersonNetworkPowerConnectorKit#70-841-026,includes
alloftheabove