https://www.phoenixcontact.com/us/products/2902853
12/6/13Page2/12
FO converters-FL MC EF 1300 MM SC-2902853
Technical data
Ambient conditions
Ambient temperature (storage/transport) -40 °C ... 85 °C
Permissible humidity (operation) 30 % ... 95 % (no condensation)
Permissible humidity (storage/transport) 30 % ... 95 % (no condensation)
Altitude 5000 m (For restrictions see manufacturer's declaration)
2000 m (With UL approval)
Degree of protection IP20
General
Electrical isolation according to IEEE 802.3
(VCC // FE // Ethernet)
Test voltage data interface/power supply 1.5 kVrms (50 Hz, 1 min.)
Standards/regulations EN 60950-1
Electromagnetic compatibility Conformance with EMC Directive 2004/108/EC
Net weight 120 g
Housing material PA 6.6-FR
Color green
MTBF 479 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5
days a week, 8 hours a day))
140 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle
(5 days a week, 12 hours a day))
MTTF 1400 Years (SN 29500 standard, temperature 25°C, operating cycle 21%
(5 days a week, 8 hours a day))
599 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%
(5 days a week, 12 hours a day))
101 Years (SN 29500 standard, temperature 40°C, operating cycle 100%
(7 days a week, 24 hours a day))
Conformance CE-compliant
ATEX II 3 G Ex nA IIC T4 Gc X
II (2) D [Ex op is Db] IIIC (PTB 06 ATEX 2042 U)
II (2) G [Ex op is Gb] IIC (PTB 06 ATEX 2042 U)
UL, USA / Canada cULus listed UL 508
Class I, Zone 2, AEx nA IIC T4
Class I, Zone 2, Ex nA IIC T4 Gc X
Class I, Div. 2, Groups A, B, C, D
Power supply
Supply voltage range 18 V DC ... 30 V DC (Screw connection)
18 V DC ... 30 V DC (as an alternative or redundant, via backplane bus
contact and system current supply)
Typical current consumption < 100 mA (24 V DC)