SPECIFICATION CONTROL DRAWING 44A0211 TITLE WIRE, RADIATION-CROSSLINKED, POLY ALKENE-INSULATED, LIGHT WEIGHT, GENERAL PURPOSE, 1000 VOLT Date 24MAR11 Revision K1 This specification sheet forms a part of the latestissue of Raychem Specification 44 and MIL-W-81044 as applicable. TABLEI!. CONSTRUCTION DETAILS MAXIMUM PARTNUMBER STRANDING STRANDED 4 (number x AWG) | CONDUCTOR rc 44A0211-_8-* 133 _x%29 * TABLE II. PERFORMANCE DETAILS BENDTESTING MANDREL DIAMETER PARTNUMBER neh) (+ 3% 1 IMMERSION, IMMERSION, LIFECYCLE AND COLD WRAP ACCELERATED AGING BEND CONDUCTOR - TIN-COATED COPPER PRIMARY INSULATION - RADIATION-GROSSLINKED, \ \ EXTRUDED POLYALKENE t CONDUCTOR DIAMETER MAXIMUM RESISTANCE AT (in.) ohms/1 000ft. JACKET - RADIATION-CROSSLINKED, MODIFIED PVF, Thickness: .004 + .001 in. FINISHED WIRE DIAMETER {in.) WEIGHT Ib) (+ 3% LIFE CYCLE AND ACCELERATED AGING MAXIMUM WEIGHT (bs/1000 ft.) Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. TE. Connectivity also reserves the right lo make changes in materials or processing, which do net affect compliance with any specification, without notification to Buyer. 4/COLORS AND COLOR CODE DESIGNATORS SHALL BE INACCORDANCE WITH MIL-STD-681. OTHER CODES AND SUFFIXES MAY BE ADDED TO THE PART NUMEER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER DIMENSIONS ARE IN INGHES, AND UNLESS GTHERWISE DESIGNATED ARE NOMINAL Page 1 of 2 THIS SPECIFICATION SHEET TAKES PRECEDENCE GVER DGCGUMENTS REFERENCED HEREIN REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID = TE TE Connectivity TE Connectivity Wire & Cable 501 Oakside Avenue Redwood City, CA 94063-3800 Phone: 1-800-227-8816 Fax: 1-650-361-6297= 7E TE Connectivity Revision SCD Number SPECIFICATION CONTROL DRAWING FF Page 2 of 2 K4 44A021 1 WIRE RATINGS AND ADDITIONAL REQUIREMENTS TEMPERATURE RATING: 150C Maximum continuous conductor temperature VOLTAGE RATING: 1000 volts (rms} at sea level ACCELERATED AGING: 300 + 2C for 6 hours Identification legibility, 225 +2C for 6 hours BLOCKING: 150 + 2C for 24 hours COLOR: White preferred FLAMMABILITY: 30 seconds (maximum); 3 in. (maximum); no flaming of facial tissue HUMIDITY RESISTANCE: Insulation Resistance, 5000 megohms for 1000 ft. (minimum) IDENTIFICATION AND STRIPING DURABILITY: 125 cycles (250 strokes) (minimum), 500 g weight IMMERSION: Diameter increase 5% (maximum): no cracking, no dielectric breakdown INSULATION ELONGATIONAND TENSILE STRENGTH: Primary Insulation, Elongation, 150% (minimum) Tensile Strength, 2500 Ibf/in? (minimum) INSULATION FLAWS: Primary Insulation, SparkTest, 2.0 kV (rms} Impulse DielectricTest, 6.0 kV (peak} Finished Wire; SparkTest, 4.0 kV (rms) at 3 kHz Impulse DielectricTest, 8.0 kV (peak} INSULATION RESISTANCE: 5000 megohms fer 1000 ft. (minimum) LIFE CYCLE: 200 + 2C for 168 hours LOW TEMPERATURE-COLD BEND: -65 +2C for 4 hours SHRINKAGE: 300 + 2C, 0.125 in. (maximum) in 12 in., AWG 26-12 300 + 2C, 0.250 in. (maximum) in 12 in., AWG 10-4 SMOKE: 200 +2C, No visible smoke SURFACE RESISTANCE: 500 megohms-in. (minimum), both readings THERMAL SHOCK RESISTANCE: 150 + 2C, 0.060 in. (maximum) VOLTAGE WITHSTAND TEST (Post Environmental}: 3000 volts (rms}, 60 Hz, 5 minutes WICKING: 2.25 in. (maximum) PART NUMBER: The *"in the part numbers on page 1 shall be replaced by color code designators. 1/ Example: AWG 20, white: 44A021 1-20-9 1/ See footer section on page 1