1
Smart Sensor Laser Sensor with Built-in Amplifier
ZX1
A CMOS Laser Sensor That’s
Optimum for Simple Measurements
A resolution of 0.002 mm that’s suitable for simple measure-
ments.
Stable measurements for any type of workpiece.
Models available with fou r di ffe re nt distance sp ec ifications .
Long-distance model for up to 1,000 mm.
This datasheet contains information only for selecting the appropriate model.
Be sure to read the instruction sh eet for usage precautions prior to using the product.
Refer to Safety Precautions on page 4.
Ordering Information
Sensors (Refer to Dimensions on page 5.)
*Sensors with Class 1 lasers are also available.
Add an “L” to the end of the model number when ordering. (Example: ZX1-LD50A61L 2M)
Accessories (sold separately)
Extension Cables for Pre-wired Connector Models An Extension Cable is not provided with the Sensor. Order an Extension Cable separately.
(Refer to Dimensions on page 6.)
Mounting Brackets A Mounting Bracket is no t provided with the Sensor. Order a Mounting Bracket separately if required.
(Refer to Dimensions on page 6.)
Appearance Connection meth od Cable length Sensing distance Model
NPN output PNP output
Pre-wired 2 m ZX1-LD50A61 2M *ZX1-LD50A81 2M *
5 m ZX1-LD50A61 5M ZX1-LD50A81 5M
Pre-wired connector 0.5 m ZX1-LD50A66 0.5M ZX1-LD50A86 0.5M
Pre-wired 2 m ZX1-LD100A61 2M *ZX1-LD100A81 2M *
5 m ZX1-LD100A61 5M ZX1-LD100A81 5M
Pre-wired connector 0.5 m ZX1-LD100A66 0.5M ZX1-LD100A86 0.5M
Pre-wired 2 m ZX1-LD300A61 2M *ZX1-LD300A81 2M *
5 m ZX1-LD300A61 5M ZX1-LD300A81 5M
Pre-wired connector 0.5 m ZX1-LD300A66 0.5M ZX1-LD300A86 0.5M
Pre-wired 2 m ZX1-LD600A61 2M *ZX1-LD600A81 2M *
5 m ZX1-LD600A61 5M ZX1-LD600A81 5M
Pre-wired connector 0.5 m ZX1-LD600A66 0.5M ZX1-LD600A86 0.5M
Cable length
Model
10 m ZX0-XC10R
20 m ZX0-XC20R
Applicable sensors Appearance Model Remarks
ZX1-LD50@
ZX1-LD100@E39-L180
Mounting Bracket: 1
Nut plate: 1
Phillips screws
(M3×30): 2
ZX1-LD300@
ZX1-LD600@E39-L181
Mounting Bracket: 1
Nut plate: 1
Phillips screws
(M4×35): 2
40
50 ± 10 mm
60
65
100 ± 35 mm
135
150
300 ± 150 mm
450
200
600 ± 400 mm
1,000
ZX1
2
Ratings and Specifications
Note: 1. False detection outside the measurement range can occur in the case of an object with high reflectance.
2. Refer to the next page for the ratings and specifications of Sensors with Cla ss 1 lasers.
*1. Classified as Class 2 by IEC60825-1 criteria in accordance with the FDA standard previsions of Laser Notice No. 50. CDRH registration has been completed.
(Center for Devices and Radiological Health) (Accession Number: 1210041)
*2. Spot diameter: Defined as 1/e2 (13. 5%) of the central intensity at the measurement center distance.
False detections can occur in the case there is light leakage outside the defined region and the surroundings of the target object have a high reflectance in com-
parison to the target object.
Accurate measurements may not be possible for workpieces that are smaller than the spot diameter.
*3. Temperature characteristic: Value for the case the space betwee n the sensor and Omron’s standar d target obje ct is secured by an aluminum jig. (Me asured at the
measurement center distance)
*4. Linearity: Indicates the error with respect to the ideal straight line of the displacement output in the case of measuring Omron’s standard target object (white ce-
ramic) at a temperat ure of 25 °C.
Linearity and measured value may vary depending on target object.
*5. Resolution: Defined in Standard Mode for Omron’s standard target object (white ceramic) after executing Smart Tuning.
The resolution indicates the repet ition accuracy for a still workpiece. Not an indicatio n of the distance accuracy.
Resolution performance may not be satisfied in a strong electromagnetic field.
*6. IP67 protection applies to the connector on pre-wired connector model s if an extension cable is connected.
*7. Use a Pre-wired Connector Model togeth er with an Extension Cable (10 m or 20 m).
Model NPN output ZX1-LD50A61
ZX1-LD50A66 ZX1-LD100A61
ZX1-LD100A66 ZX1-LD300A61
ZX1-LD300A66 ZX1-LD600A61
ZX1-LD600A66
Item PNP output ZX1-LD50A81
ZX1-LD50A86 ZX1-LD100A81
ZX1-LD100A86 ZX1-LD300A81
ZX1-LD300A86 ZX1-LD600A81
ZX1-LD600A86
Measurement range 50 ± 10 mm 100 ± 35 mm 300 ± 150 mm 600 ± 400 mm
Light source (wave length) Visible-light semi conductor laser
(wavelength: 660 nm, 1 mW max., IEC/EN Class 2, FDA Class 2 *1)
Spot diameter (typical)
(Defined at the measurement center dis-
tance) *20.17 mm dia. 0.33 mm dia. 0.52 mm dia. 0.56 mm dia.
Power consumption 2,500 mW max. (105 mA max. at 24 VDC, 210 mA max. at 12 VDC)
Current consum pti on 250 mA max. (at power supply voltage 10 VDC)
Control output Load power supply voltage: 30 VDC max., Load current: 100 mA max.
(Residual voltage: 1 V max. (load current 10 mA or less), 2 V max. (load current of 10 to
100 mA))
Analog output Current output: 4 to 20 mA, maximum load resistance: 300 Ω
Functions
Smart tuning, keep function, background re moval, O FF-delay timer, ON-delay timer, one-shot
timer, ON/OFF-delay timer, zero reset, area output, eco function, hysteresis width setting, and
setting initialization
Indicators Digital display (red), output indicator (OUT1, OUT2) (orange), zero reset indicator (or-
ange), menu indicator (orange), laser ON indicator (green), and smart tu ning indicator
(blue)
Response time Judgment output Super-high-speed (SHS) Mode: 1 ms
High-speed (HS) Mode: 10 ms
Standard (Stnd) Mode : 100 ms
Laser OFF inpu t 200 ms max.
Zero reset input 200 ms max.
Temperature characteristic *30.03% F.S./°C 0.04% F.S./°C
Linearity *4±0.15% F.S. ±0.25% F.S. ±0.25% F.S.
(200 to 600 mm)
±0.5% F.S.
(entire range)
Resolution *52 μm7 μm 30 μm80 μm
Ambient illumi na ti on Illumination on received light surface:
7,500 lx or less (incandescent light) Illumination on received light surface:
5,000 lx or less (incandescent light)
Ambient temperature Operating: -10 to +55°C, Storage: -15 to +70°C (with no icing or condensation)
Ambient humid ity Operating and storage: 35% to 85% (with no condensation)
Dielectric strength 1,000 VAC, 50/60 Hz, 1 minute
Vibration resistance (des truction) 10 to 55 Hz, 1.5-mm double amplitude, 2 hours each in X, Y, and Z directions
Shock resistance (destructio n) 500 m/s2 3 times each in X, Y, and Z directions
Degree of protection *6IEC 60529, IP67
Connection method *7Pre-wired model (Standard cable length: 2 m, 5 m)
Pre-wired connector model (Standard cable length: 0.5 m)
Weight
(packed state/
sensor only )
Pre-wired models
(2 m) Approx. 240 g / Approx. 180 g Approx. 270 g / Approx. 210 g
Pre-wired models
(5 m) Approx. 450 g / Approx. 330 g Approx. 480 g / Approx. 360 g
Pre-wired connec-
tor models (0.5 m) Approx. 170 g / Approx. 110 g Approx. 200 g / Approx. 140 g
Materials Case and cover: PBT (polybutyl ene terephthalate), Optical window: Glass, Cable: PVC,
Mounting hole part: SUS303
Accessories Instruction sheet and Laser warning label (English)
ZX1
3
Ratings and Specifications of Sensors with Class 1 lasers (ZX1-LD@L)
The ratings and specifications that are different from those of the Sensors with Class 2 lasers are given below.
Accession Number: 1210041
Engineering Data (Typical)
Angle Characteristic
Linearity Characteristic for Different Materials
Note: 1. Measurement conditions for the ZX1-LD@@: Ambient temperature of 25°C in Standard Mode after executing Smart Tuning.
2. The ambient conditions or workpiece may adversely affect the engineering data of the ZX1-LD@L.
3. The X-axis displacement indicates the measurement distance displayed on a digital display.
The measurement distance displayed on a digital display takes the measurement center distance as 0 and displays the near side of the Sensor as positive and the far side as negative.
Model
Item ZX1-LD50A61L/ZX1-LD50A81L
ZX1-LD100A61L/ZX1-LD100A81L ZX1-LD300A61L/ZX1-LD300A81L
ZX1-LD600A61L/ZX1-LD600A81L
FDA Class Class1 0.24mW max.
IEC/EN Class Class1 0.24mW max.
Ambient illumination
Illumination on received light surface 5,000 lx or less (incandescent light) Illumination on received light surface 2,500 lx or less (incandesc ent light)
Connection method
Pre-wired model (2 m)
Accessories Instruction sheet and Explanatory label (English), FDA certification label
ZX1-LD50@
Side-to-side Inclination ZX1-LD100@
Side-to-side Inclination ZX1-LD300@
Side-to-side Inclination ZX1-LD600@
Side-to-side Inclination
ZX1-LD50@
Front-to-back Inclination ZX1-LD100@
Front-to-back Inclination ZX1-LD300@
Front-to-back Inclination ZX1-LD600@
Front-to-back Inclination
ZX1-LD50@ZX1-LD100@ZX1-LD300@ZX1-LD600@
Error (%F.S.)
3
2
1
0
–1
–2
–3 0–10–20–30–40–50 10 20 30 40 50
Angle of Inclination (°)
White ceramic
SUS304, mirror finish
Black rubber
+ Inclination
− Inclination
Measurement
center distance
Error (%F.S.)
3
2
1
0
–1
–2
–3 0–10–20–30–40–50 10 20 30 40 50
Angle of Inclination (°)
White ceramic
SUS304, mirror finish
Black rubber
+ Inclination
− Inclination
Measurement
center distance
Error (%F.S.)
3
2
1
0
–1
–2
–3 0–10–20–30–40–50 10 20 30 40 50
Angle of Inclination (°)
White ceramic
SUS304, mirror finish
Black rubber
+ Inclination
− Inclination
Measurement
center distance
Error (%F.S.)
3
2
1
0
–1
–2
–3 0–10–20–30–40–50 10 20 30 40 50
Angle of Inclination (°)
White ceramic
SUS304, mirror finish
Black rubber
+ Inclination
− Inclination
Measurement
center distance
Error (%F.S.)
3
2
1
0
–1
–2
–3 0–10–20–30–40–50 10 20 30 40 50
An
g
le of Inclination
(
°
)
White ceramic
SUS304, mirror finish
Black rubber
+ Inclination
− Inclination
Measurement
center distance
Error (%F.S.)
3
2
1
0
–1
–2
–3 0–10–20–30–40–50 10 20 30 40 50
An
g
le of Inclination
(
°
)
White ceramic
SUS304, mirror finish
Black rubber
+ Inclination
− Inclination
Measurement
center distance
Error (%F.S.)
3
2
1
0
–1
–2
–3 0–10–20–30–40–50 10 20 30 40 50
An
g
le of Inclination
(
°
)
White ceramic
SUS304, mirror finish
Black rubber
+ Inclination
− Inclination
Measurement
center distance
Error (%F.S.)
3
2
1
0
–1
–2
–3 0–10–20–30–40–50 10 20 30 40 50
An
g
le of Inclination
(
°
)
White ceramic
SUS304, mirror finish
Black rubber
+ Inclination
− Inclination
Measurement
center distance
2.0
1.5
1.0
0.5
0.0
0.5
1.0
1.5
2.0
10 10864202468
Error (%F.S.)
White ceramic
SUS304, mirror finish
Substrate
Displacement
(mm)
Measurement
center distance
FAR side NEAR side
2.0
1.5
1.0
0.5
0.0
0.5
1.0
1.5
2.0
35
352515505
1525
Error (%F.S.)
White ceramic
SUS304, mirror finish
Substrate
Displacement
(mm)
Measurement
center distance
FAR side NEAR side
2.0
1.5
1.0
0.5
0.0
0.5
1.0
1.5
2.0
150 100 15050050100
Error (%F.S.)
White ceramic
SUS304, mirror finish
Substrate
Displacement
(mm)
Measurement
center distance
FAR side NEAR side
Error (%F.S.)
Displacement
(mm)
Measurement
center distance
2.0
1.5
1.0
0.5
0.0
0.5
1.0
1.5
2.0
400 100 4003002000100200300FAR side NEAR side
White ceramic
SUS304, mirror finish
Substrate
Displacement (mm) Sensor
FAR side NEAR side
Measurement
center distance
Measurement diagram
Workpiece
ZX1
4
I/O Circuit Diagrams
NPN Output Model (Negative Comm on)
ZX1-LD50A61(L) /ZX1-LD50A66
ZX1-LD100A61(L) /ZX1-LD100A66
ZX1-LD300A61(L) /ZX1-LD300A66
ZX1-LD600A61(L) /ZX1-LD600A66
PNP Output Mode l (Positive Common)
ZX1-LD50A81(L) /ZX1-LD50A86
ZX1-LD100A81(L) /ZX1-LD100A86
ZX1-LD300A81(L) /ZX1-LD300A86
ZX1-LD600A81(L) /ZX1-LD600A86
*1. TUNE1 input: tuning external input for channel 1
TUNE2 input: tuning external input for channel 2
LD-OFF input: Laser OFF input
*2. The input specification is as follows:
Timing Charts Safety Precautions
ZX1-LD@@@: Class 2, ZX1-LD@@@L: Class1
Do not expose your eyes to the laser radiation
either directly or in directly ( i.e., after reflectio n
from a mirror or shiny surface).
The laser radiation has a high power density and expo-
sure may result in loss of sight.
Do not disassemble the product.
Doing so may cause the laser beam to leak,
resulting in the danger of visual impairment.
Note: For Precautions for saf e use and Precautions for correct use, refer to the
Instruction Sheet supplied with the product.
Brown: 10 to 30 VDC
10 to 30 VDC
White: OUT1
judgment output
Green: OUT2
judgment output
Blue: GND (0 V)
Orange: TUNE1 input
1, 2
1, 2
1, 2
2
Pink: TUNE2 input
Purple: Zero reset input
Red: LD-OFF input
Black: Analog output
300 Ω max.
Shield: Analog GND
Current output
4 to 20 mA
Internal circuits
Load
Load
Load
Brown: 10 to 30 VDC
10 to
30 VDC
White: OUT1
judgment output
Green: OUT2
judgment output
Blue: GND (0 V)
Orange: TUNE1 input
1, 2
1, 2
1, 2
2
Pink: TUNE2 input
Purple: Zero reset input
Red: LD-OFF input
Black: Analog output
300 Ω max.
Shield: Analog GND
Current output
4 to 20 mA
Internal circuits
Load
Load
Load
NPN Output Model PNP Output Model
ON Short-circuited with 0-V terminal or 1.5 V max. Supply voltage short-circuited or supply voltage within -1.5 V
OFF Open (leakage current: 0.1 mA max.) Open (leakage current: 0.1 mA max.)
ON
Set time within 3 s
OFF
TUNE
input
Tuning completion
within 3 s
ON
OFF
TUNE
input
4 ms or
more
Signal
reception Tuning
completion
Execution Cancellation
ON
within 196 ms 3 s
OFF
Effective zero reset period
Zero reset
input
4 ms or
more
Signal
reception Zero reset
execution Zero reset
cancellation
Laser emission ON OFF
Laser emission OFF ON
ON
OFF
LD-OFF
input
within 6 ms
within 200 ms
4 ms or
more
Signal
reception
Laser emission
OFF
Laser emission
ON
TUNE1 Input / TUNE2 Input
(1) Time identification tuning type
(2) Tuning type other than time identification
Zero Reset Input
LD-OFF Input
This datasheet contains information only for selecting the ap-
propriate model.
Be sure to read the Instruction Sheet for usage precautions pri-
or to using the product.
Laser Safety
WARNING
ZX1
5
Dimensions
Sensors
(Unit: mm)
Tolerance class IT16 applies to dimensions in this datasheet unless otherwise specified.
*
ZX1-LD50: L = 50, A = 21°
ZX1-LD100: L = 100, A = 11.5°
Reference surface
Reference surface
Reference surface Emitter center position mark
Emitter axis
Two, 3.2 dia
(mounting holes)
10.5
15.1
42.3
14.23
Emitter
center
7
16.7
10.1
Emitter
axis
Receiver axis
(10.5)
(2) 35.3 3.2
47
52.5
46.1
L
*
(Measurement
center distance)
A
*
(10.2)
11.7
24.1
Mounting hole dimensions
Emitter center position mark Vinyl insulated round robot cable, 6.5 dia., 9 conductors (Conductor cross section:
0.125 mm², Insulator diameter: 0.7 mm)
Standard length: 2 m / 5 m (pre-wired model), 0.5 m (pre-wired connector model)
Minimum bending radius: 39 mm
2.5
37.8
2.4 18.7 2-M3
P=0.5
Reference
surface
Reference
surface
23.6
±0.1
3.2
±0.1
35.3
±0.1
49.3
±0.1
Pre-wired Models
ZX1-LD50A61(L)
ZX1-LD50A81(L)
ZX1-LD100A61(L)
ZX1-LD100A81(L)
Pre-wired Connector Models
ZX1-LD50A66
ZX1-LD50A86
ZX1-LD100A66
ZX1-LD100A86
(13.6)
50.1
(1.9)
4.5
45.6
57
66
15.5
L*(10.2)
10.1
7
55.8
10.7
27.2
17
22
13.6
A*
*
ZX1-LD300: L = 300, A = 6.6°
ZX1-LD600: L = 600, A = 3.4°
Reference surface
Reference surface
Reference surface
E
m
i
tter center pos
i
t
i
on mar
k
Emitter axis
Two, 4.5 dia
(mounting holes)
Emitter
center
Emitter
axis
Receiver axis
(Measurement
center distance)
Mounting hole dimensions
Emitter center position mark Vinyl insulated round robot cable, 6.5 dia., 9 conductors (Conductor cross section:
0.125 mm², Insulator diameter: 0.7 mm)
Standard length: 2 m / 5 m (pre-wired model), 0.5 m (pre-wired connector model)
Minimum bending radius: 39 mm
3
50.3
3 21.3 2-M4
P=0.7 4.5±0.1
Reference
surface
Reference
surface
30.1±0.1
45.6±0.1
61.5±0.1
Pre-wired Models
ZX1-LD300A61(L)
ZX1-LD300A81(L)
ZX1-LD600A61(L)
ZX1-LD600A81(L)
Pre-wired Connector Models
ZX1-LD300A66
ZX1-LD300A86
ZX1-LD600A66
ZX1-LD600A86
Display, Indicators, and Controls Pre-wired connector
TUNE Button
[ST] Smart tuning indicator (blue)
[LD ON] Laser ON indicator (green)[MENU] Menu indicator (orange)
[ZERO] Zero reset indicator (orange)
OUT1 output indicator (orange)
OUT2 output indicator (orange)
Up Button
DOWN Button
MODE Button
Digital display
15.5 dia.
39.8
6
ZX1
Accessories (sold separately)
Extension Cables for Pre-wired Connector Models
ZX0-XC10R (10 m)
ZX0-XC20R (20 m)
Shield
37.3
15 dia.
L *
90
* Cable length (L) is as follows.
ZX0-XC10R: 10 m, ZX0-XC20R: 20 m
Vinyl insulated round robot cable, 6.5 dia.
Minimum bending radius: 39 mm
Bending start position: 40 mm
Mounting Bracket for ZX1-LD50@/ZX1-LD100@
E39-L180
Installation Method (ZX1-LD50@/ZX1-LD100@)
Using E39-L180 Mounting Bracket Installation Method (ZX1-LD300@/ZX1-LD600@)
Using E39-L181 Mounting Bracket
Mounting Bracket for ZX1-LD300@/ZX1-LD600@
E39-L181
Material : Stainless steel (SUS304)
Thickness : 2.0 mm
Accessories : Two phillips screws
(M3×30, P = 0.5, Stainless steel)
and one nut plate
Material : Stainless steel (SUS304)
Thickness : 2.0 mm
Accessories : Two phillips screws
(M4×35, P = 0.7, Stainless steel)
and one nut plate
Nut plate
Mounting Bracket Mounting Bracket
Nut plate
46.1
11.7
5.5°
41.3
32.1 4.8
62
3.5
18.5
3.5
10
19.75
14.8
12
2-R2
20
47.6
6
53.6
P=0.5
2-M3
3.5°
8°
15.5
57
52
42.4 6.2
4.5 dia.
76
22
12
12 4.5
19.1
4.5
25.95 23
8
67.159.1
P=0.7
2-M4
7.9
3.2
62
41.3 4.4
22.5
18
45.6
18.137.8
3.2
8.3
55.2
76
25.6
22.3
51.2
18.5
52.6
Reference
surface Reference
surface
Mounting Bracket
Nut plate
Mounting Bracket
Nut plate
2-R2
3.5 dia.
Material : Stainless steel
(SUS304)
Thickness : 1.5 mm
Material : Stainless steel
(SUS304)
Thickness : 2.0 mm
READ AND UNDERSTAND THIS DOCUMENT
Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or comments.
WARRANTY
OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR
PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET
THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY
CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON’S ANALYSIS
CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE,
OR INAPPROPRIATE MODIFICATION OR REPAIR.
SUITABILITY FOR USE
THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF PERSONS, AND
SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PR OTECTIVE DEVICE FOR SUCH PURPOSES. Please ref er to separate catalogs f or OM R ON's safety rated
products.
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer’s application or use of the
product.
At the customer’s request, OMR ON will provide applicab le third party certification documents identifying ratings and limitations of use that apply to the products. This inf ormation by
itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustiv e list of all possib le uses of the products, nor is
it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations
subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENS URING THAT THE SYSTEM AS A WHOLE H AS
BEEN DESIGNED TO ADDRESS THE RISKS , AND THAT THE OMRON PR ODUCT IS PR OPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL
EQUIPMENT OR SYSTEM.
PERFORMANCE DATA
Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s
test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant constr uction changes are made. However, some specifications of
the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request.
Please consult with your OMRON representative at any time to confirm actual specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading
errors, or omissions.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof.
COPYRIGHT AND COPY PERMISSION
This document shall not be copied for sales or promotions without permission.
This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this document in any manner,
for any other purpose. If copying or transmitting this document to another, please copy or transmit it in its entirety.
Authorized Distributor:
In the interest of product improvement,
specifications are subject to change without notice.
Cat. No. E416-E1-02 Printed in Japan
0112(1111)
© OMRON Corporation 2011 All Rights Reserved.
OMRON Corporation Industrial Automation Company
OMRON ELECTRONICS LLC
One Commerce Drive Schaumburg,
IL 60173-5302 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
Regional Headquarters
OMRON EUROPE B.V.
Sensor Business Unit
Carl-Benz-Str. 4, D-71154 Nufringen, Germany
Tel: (49) 7032-811-0/Fax: (49) 7032-811-199
Contact: www.ia.omron.com
Tokyo, JAPAN
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandr a Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 CSM_2_1_1113