AJM90 Series
www.xppower.com 2
AC-DC Power Supplies
Input
Characteristic Minimum Typical Maximum Units Notes & Conditions
Input Voltage 80 264 VAC Derate output power below 90 VAC to 90% at 85 VAC and
85% at 80 VAC
Input Frequency 47 63 Hz
Input Current 1.5/0.6 A Measured at 115/230 VAC
Inrush Current 60/100 A 115/230 VAC, cold start at 25 °C
Power Factor 0.9 EN61000-3-2 Class A
Earth Leakage Current 220 250 µA 264 VAC, 60 Hz
No Load Input Power 0.21 W
Input Protection T3.15A/250 VAC internal fuse in both line
Output
Characteristic Min. Typ. Max. Units Notes & Conditions
Output Voltage 12 48 VDC See Models and Ratings table
Initial Set Accuracy ±2 % At 50% load
Minimum Load No minimum load required
Start Up Delay 3s
Start Up Rise Time 50 ms
Hold Up Time 10 ms Full load and 115 VAC
Line Regulation ±0.5 %
Total Regulation ±5 %
Transient Response 4%
Maximum deviation, recovering to less than 1% within
500 µs for 25% step load
Ripple and Noise 1 % pk-pk
150 mV pk-pk for 12 V model, measured with 20 MHz
bandwidth and 10 µF electrolytic in parallel with 0.1 µF
ceramic capacitor.
Overshoot 5%At turn on / turn off
Overload Protection 115 175 %
Overvoltage Protection 112 150 % Recycle mains to reset
Short Circuit Protection Trip and restart (hiccup), auto resetting
Thermal Protection Measured internally, recycle AC to reset
Temperature Coefficient 0.04 %/°C
Patient Leakage Current 100 µ A 264 VAC, 60 Hz
Environmental
Characteristic Minimum Typical Maximum Units Notes & Conditions
Operating Temperature 0 +60 °C Derate from 100% load at 40 °C to 50% load at 60 °C
Cooling Natural convection
Operating Humidity 5 90 %RH Non-condensing
Storage Temperature -40 +85 °C
Operating Altitude 5000 m
Shock IEC68-2-27, 30 g, 11 ms half sine, 3 times in each of 6 axes
Vibration IEC68-2-6, 10-500 Hz, 2 g 10 mins/sweep, 60 mins for each of 3 axes
Derating Curve
60%
20%
40%
80%
Ambient Temperature (ºC)
Output Power (%)
100%
40 60
20
0