Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 1266A Multi-Conductor - Single-Pair Cable For more Information please call 1-800-Belden1 General Description: 22 AWG stranded (7x30) TC conductors, polypropylene insulation, twisted pair, overall Beldfoil shield (100% coverage), 24 AWG stranded TC drain wire, PVC jacket. Physical Characteristics (Overall) Conductor AWG: # Pairs AWG Stranding Conductor Material 1 22 7x30 TC - Tinned Copper Total Number of Conductors: 2 Insulation Insulation Material: Insulation Material Wall Thickness (mm) PP - Polypropylene 0.254 Outer Shield Outer Shield Material: Outer Shield Trade Name Type Outer Shield Material Beldfoil(R) Coverage (%) Tape Aluminum Foil-Polyester Tape 100 Outer Shield Drain Wire AWG: AWG Stranding Drain Wire Conductor Material 24 7x32 TC - Tinned Copper Outer Jacket Outer Jacket Material: Outer Jacket Material Nom. Wall Thickness (mm) PVC - Polyvinyl Chloride 0.508 Overall Cable Overall Nominal Diameter: 3.632 mm Pair Pair Color Code Chart: Number Color 1 Black & Red Mechanical Characteristics (Overall) Operating Temperature Range: -20C To +60C UL Temperature Rating: 60C Bulk Cable Weight: 20.835 Kg/Km Max. Recommended Pulling Tension: 111.205 N Min. Bend Radius/Minor Axis: 38.100 mm Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CM Page 1 of 3 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 1266A Multi-Conductor - Single-Pair Cable CEC/C(UL) Specification: CM EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Flame Test UL Flame Test: UL1685 UL Loading Plenum/Non-Plenum Plenum (Y/N): No Electrical Characteristics (Overall) Nom. Characteristic Impedance: Impedance (Ohm) 55 Nom. Inductance: Inductance (H/m) 0.59058 Nom. Capacitance Conductor to Conductor: Capacitance (pF/m) 98.43 Nom. Capacitance Cond. to Other Conductor & Shield: Capacitance (pF/m) 177.174 Nominal Velocity of Propagation: VP (%) 66 Nominal Delay: Delay (ns/m) 4.9215 Nom. Conductor DC Resistance: DCR @ 20C (Ohm/km) 49.215 Nominal Outer Shield DC Resistance: DCR @ 20C (Ohm/km) 59.058 Max. Operating Voltage - UL: Voltage 300 V RMS Max. Recommended Current: Current 2.3 Amps per conductor @ 25C Notes (Overall) Notes: Unique design features lower capacitance and greater flexibility than standard audio pair constructions. Page 2 of 3 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 1266A Multi-Conductor - Single-Pair Cable Put Ups and Colors: Item # Putup Ship Weight Color 1266A 001U1000 305 MT 6.804 KG BROWN Notes Item Desc 2 #22 PP FS PVC 1266A 002U1000 305 MT 6.804 KG RED 2 #22 PP FS PVC 1266A 003U1000 305 MT 6.804 KG ORANGE 2 #22 PP FS PVC 1266A 004U1000 305 MT 6.804 KG YELLOW 2 #22 PP FS PVC 1266A 005U1000 305 MT 6.804 KG GREEN, DARK 2 #22 PP FS PVC 1266A 006U1000 305 MT 6.804 KG BLUE, LIGHT 2 #22 PP FS PVC 1266A 007U1000 305 MT 6.804 KG VIOLET 2 #22 PP FS PVC 1266A 008U1000 305 MT 6.804 KG GRAY 2 #22 PP FS PVC 1266A 009U1000 305 MT 6.804 KG WHITE 2 #22 PP FS PVC 1266A 010U1000 305 MT 6.804 KG BLACK 1266A 0101000 305 MT 6.804 KG BLACK 2 #22 PP FS PVC C 2 #22 PP FS PVC Notes: C = CRATE REEL PUT-UP. Revision Number: 1 Revision Date: 08-10-2012 (c) 2013 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor's inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC. Page 3 of 3 10-30-2013