120W AC-DC Reliable Green Medical Adaptor GSM120B series + + Features Description { File Name:GSM120B-SPEC 2020-08-03 120W AC-DC Reliable Green Medical Adaptor GSM120B series SPECIFICATION ORDER NO. SAFETY MODEL NO. DC VOLTAGE OUTPUT GSM120B20-R7B GSM120B24-R7B GSM120B48-R7B GSM120B20 GSM120B24 GSM120B48 Note.2 12V 15V 20V 24V 48V 8.5A 7A 6A 5A 2.5A CURRENT RANGE 0 ~ 8.5A 0 ~ 7A 0 ~ 6A 0 ~ 5A 0 ~ 2.5A RATED POWER (max.) 102W 105W 120W 120W 120W RIPPLE & NOISE (max.) Note.3 100mVp-p 120mVp-p 150mVp-p 180mVp-p 200mVp-p VOLTAGE TOLERANCE Note.4 5.0% LINE REGULATION Note.5 1.0% 5.0% 1.0% 5.0% 5.0% 1.0% 4.0% 3.0% 1.0% 3.0% 2.5% 1.0% 2.5% 90% 91.5% 5.0% SETUP, RISE TIME Note.6 1500ms, 30ms / 230VAC HOLD UP TIME (Typ.) VOLTAGE RANGE 40ms / 230VAC 24ms / 115VAC at full load Note.7 80 ~ 264VAC 113 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.93 / 230VAC EFFICIENCY (Typ.) 88% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.4A / 115VAC LEAKAGE CURRENT(max.) OVERLOAD PROTECTION GSM120B15-R7B GSM120B15 RATED CURRENT LOAD REGULATION INPUT GSM120B12-R7B GSM120B12 OVER VOLTAGE 2000ms, 30ms / 115VAC at full load PF>0.97 / 115VAC at full load 89% 89.5% 0.7A / 230VAC Cold start 35A / 115VAC 70A / 230VAC Touch current < 100 A/264VAC 105 ~ 160% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 105 ~ 135% rated output voltage Protection type : Shut down o/p voltage, re-power on to recover OVER TEMPERATURE Shut down o/p voltage, re-power on to recover WORKING TEMP. WORKING HUMIDITY -30 ~ +70 (Refer to "Derating Curve") 20% ~ 90% RH non-condensing ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION -40 ~ +85, 10 ~ 95% RH non-condensing 0.03% / (0 ~ 40) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes OPERATING ALTITUDE Note.8 3000 meters IEC60601-1/IEC60601-1-11, EN60601-1/ EN60601-1-11, ANSI/AAMI ES60601-1 / ES60601-1-11(3.1 version), SAFETY STANDARDS CAN/CSA-C22.2 No. 60601-1:14 - Edition 3, EAC TP TC 004 approved ISOLATION LEVEL WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION SAFETY & EMC (Note. 9) CONNECTOR NOTE Test Level / Note Class B Class B Harmonic current EN61000-3-2 Class A Voltage flicker EN61000-3-3 ----- Parameter Standard Test Level / Note ESD EN61000-4-2 RF field susceptibility EN61000-4-3 EFT bursts EN61000-4-4 Level 4, 15KV air ; Level 4, 8KV contact Level 3, 10V/m( 80MHz~2.7GHz ) Table 9, 9~28V/m( 385MHz~5.78GHz ) Level 3, 2KV Surge susceptibility EN61000-4-5 Conducted susceptibility EN61000-4-6 Magnetic field immunity EN61000-4-8 Voltage dip, interruption EN61000-4-11 EN60601-1-2, EN61204-3 EMC IMMUNITY OTHERS Primary-Secondary: 2xMOPP I/P-O/P: 4KVAC I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH Parameter Standard EN55011 (CISPR11), FCC PART 15 / CISPR22, Conducted emission CAN ICES-3(B)/NMB-3(B) EN55011 (CISPR11), FCC PART 15 / CISPR22, Radiated emission CAN ICES-3(B)/NMB-3(B) MTBF DIMENSION PACKING PLUG Level 3, 1KV/Line-Line Level 3, 10V Level 4, 30A/m 100% dip 1 periods, 30% dip 25 periods, 100% interruptions 250 periods 372K hrs min. MIL-HDBK-217F(25) 167*67*35mm (L*W*H) 0.6Kg; 20pcs/13,0Kg/0.89CUFT See page 4~5; Other type available by customer requested CABLE See page 4~5; Other type available by customer requested For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies." (as available on http://www.meanwell.com) File Name:GSM120B-SPEC 2020-08-03 GSM120B 120W AC-DC Reliable Green Medical Adaptor Derating Curve series Static Characteristics 100 100 90 80 LOAD (%) LOAD (%) 80 60 50 40 70 60 50 20 40 -30 0 10 20 30 40 50 60 70 (HORIZONTAL) 80 90 100 110 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz AMBIENT TEMPERATURE () Mechanical Specification Case No. GS120A Unit:mm 35 UL2464 16AWGx4C 100050mm for 12V UL2464 18AWGx4C 120050mm for 15 ~ 48V 167 67 303mm Power LED AC Inlet IEC320-C8 DC output plug Standard plug: R7B R7B Pin Assignment 2 3 1 4 2 1 KYCON KPPX-4P equivalent 3 4 PIN NO. OUTPUT 1 +Vo 2 -Vo 3 -Vo 4 +Vo File Name:GSM120B-SPEC 2020-08-03 GSM120B 120W AC-DC Reliable Green Medical Adaptor series DC plug changeable through: (1) Customization of the standard part with an optional DC plug according to the table (MOQ applicable) (2) Quick adapter accessory (sold separately without MOQ) Please refer to below table and online selection guide : Example quick adapter accessory: Optional DC plug: (Available in customized cable or quick adapter) Tuning Fork Style C A Type No. A OD B ID C L P1J 5.5 2.1 11.0 P1M 5.5 2.5 11.0 Quick Adapter Accessory Available for 15 ~ 48V B (Straight) Min. DIN 4 Pin with Lock (female) 23 14 Type No. R7BF KYCON KPJX-CM-4S equivalent DIN 5 Pin (male) 3 1 4 2 5 NEUTRIK XLR NC4FX equivalent 4 3 1 Type No. R1B Type No. MIC4 2 MOLEX 39-01-2060 (4.2mm) equivalent 4 5 6 1 2 3 FG not connected to output connector Type No. C6P Pin Assignment Output PIN No. +Vo 1 -Vo 2 3 -Vo 4 +Vo Pin Assignment Output PIN No. -Vo 1 -Vo 2 3 +Vo 4 -Vo 5 +Vo Pin Assignment Output PIN No. +Vo 1 +Vo 2 3 -Vo -Vo 4 Pin Assignment Output PIN No. +Vo 1 +Vo 2 3 +Vo -Vo 4 5 -Vo 6 -Vo (Current rating: 7.5A max.) None None None None File Name:GSM120B-SPEC 2020-08-03 GSM120B 120W AC-DC Reliable Green Medical Adaptor AMP 1-480702-0 (6.35mm) equivalent 4 3 2 1 Type No. C4P FG not connected to output connector Stripped and tinned leads Type No. L Pin Assignment Output PIN No. +Vo 1 +Vo 2 3 -Vo 4 -Vo Pin Assignment Output PIN No. series Quick Adapter Accessory None (red,blue) 1 2 1 +Vo 2 -Vo None L1 (black,white) by customer Length of Land L1 by request ( MW's standard length, L: 25 mm, L1: 5 mm) Installation Manual Please refer to : http://www.meanwell.com/manual.html File Name:GSM120B-SPEC 2020-08-03