TLR-2B, 2H, 3A, 3AW
metal plate current sense resistor
applications and ratings
Derating Curve Temperature Rise
environmental applications
% Rated Power
100
80
60
40
20
-80 -60 -40 0 40 60 80 100180
70
20
Am bie nt Te mpe rat ure
(°C)
0
120
170
-20 140
-65
160
3
Temperature Rise
(°C)
125
75
50
25
255075100
% Rated Power
0
0
1
2
100 2H
2B
2B
2H
1
2
Parameter
Requirement ∆ R ±%
Limit Typical Test Method
Resistance
T.C.R.
25°C
+25°C/+100°C
Within regulated
tolerance
Within specified
T.C.R.
—
—
Resistance to Solder Heat 260°C ± 5°C, 10 ~ 12 seconds
±0.5% ±0.3%
Rapid Change of Temperature -55°C (15 minutes), +150°C (15 minutes), 1000 cycles
±0.5% ±0.4%
Moisture Resistance MIL-STD-202, Method 106, 0% power, 7a and 7b not required
±0.5% ±0.1%
Biased Humidity 85°C ± 2°C, 85% RH, 1000 hours, 10% bias
±0.5% ±0.1%
Endurance (Ambient Temp.) 70°C ± 2°C, 1000 hours, 1.5 hr ON, 0.5 hr OFF cycle
±1.0% ±0.3%
High Temperature Exposure ±155°C (2B, 2H, 3AW), ±170°C (3A), 1000 hours
±1.0% ±0.6%
Temperature Rise
(°C)
125
75
50
25
255075100
% Rated Power
0
0
1
2
100
3AW
3A
3A
3AW
1
2
% Rated Power
100
80
60
40
20
-80 -60 -40 0 40 60 80 100 180
105
20
Terminal Part Temperature
(°C)
0
120
170
-20 140
-65
160
3
TLR2B/2H 8mΩTLR3A/3AW 4mΩ
* Please contact factory for T.C.R.: ±50ppm/°C ** Contact factory for 2mΩ dimensions
If any questions should arise whether to use the “Rated Ambient Temperature” or the “Rated Terminal Part Temperature,” please give priority
to the “Rated Terminal Part Temperature.” Prior to use and for more details refer to “Introduction of the derating curves on the terminal part
temperature” in the beginning of the catalog.
Resistance
Tolerance
Standard
Resistance
(Ω)
Part
Designation
Rated
Ambient
Temperature
Operating
Temperature
Range
Power
Rating
@ 70°C
T.C.R.
(ppm/°C)
Max.*
TLR3A 1W ±150
±200
1m, 2m
3m, 4m
70°C -65°C to +170°CF: ±1%
TLR2B 1/2W (.5W)
1m,1.5m,2m,3m,4m,5m,
6m,7m,
8m,9m,10m,11m,
12m,13m,15m,16m,18m,20m
70°C -65°C to +170°C
TLR2H 1W 1m,2m,3m,4m,5m,
6m,7m,8m,9m,10m
70°C -65°C to +170°C
TLR3AW 2W
±150
70°C
105°C
105°C
105°C
105°C
±75 F: ±1%
±75 F: ±1%
±75 F: ±1% -65°C to +170°C
0.5m,0.68m,0.75m,0.82m,
1m,1.5m,2m**,3m,4m,
5m,6m,7m,8m,9m,10m
Rated
Terminal Part
Temperature
Performance Characteristics
For resistors operated at an ambient
temperature of 70°C or above, a power
rating shall be derated in accordance
with the above derating curve.
Regarding the temperature rise, the value of the temperature
varies per conditions and board for use since the temperature
is measured under our measuring conditions.
±170°C (2B, 2H, 3AW), 1000 hours
±1.0% + 0.0001Ω––
For resistors operated at a terminal part
temperature of described for each size or
above, a power rating shall be derated in
accordance with the derating curve.
Please refer to “Introduction of the derating
curve based on the terminal part temperature”
on the beginning of our catalog before use.
77
KOA Speer Electronics, Inc. • 199 Bolivar Drive • Bradford, PA 16701 • USA • 814-362-5536 • Fax: 814-362-8883 • www.koaspeer.com
Specifications given herein may be changed at any time without prior notice. Please confirm technical specifications before you order and/or use. 10/29/15
resistors