2c 15A, 4c 10A polarized power relays SP RELAYS FEATURES RoHS compliant 1. Small, slim form factor Facilitating the form factor reduction of devices, the overall height of the relay package is less than half that of our HP relay. 2. High sensitivity The high-efficiency polarized electromagnetic mechanism in conjunction with our exclusive spring alignment method achieves levels of sensitivity higher than relays that have been available up to now. For both the 2 Form C and 4 Form C single side stable and 2 coil latching types, the 150 mW minimum operating power level allows direct driving by transistor or chip controllers. 3. High reliability and long life With a structure that ensures almost perfectly complete twin contact and minimal contact bounce, you get greater reliability than has so far been provided by power relays. 4. Latching types also available 1 coil latching and 2 coil latching types are available. In cases where it was formerly unavoidable to use plural relays for large power memory, you can now use a single SP relay. 5. Strong resistance to vibration and shock Our balanced armature technology well withstands vibration and shocks. It provides strong resistance to vibration and shock. 6. Terminals and mounting boards are available TYPICAL APPLICATIONS 1. Electrical power device 2. Robots 3. Railway signal equipment Protective construction: Dust cover type -1- ASCTB208E 201606-T SP ORDERING INFORMATION SP Contact arrangement 2: 2 Form C 4: 4 Form C Terminal shape Nil: Plug-in type P: PC board type Operating function Nil: Single side stable L: 1 coil latching L2: 2 coil latching Nominal coil voltage 3, 5, 6, 12, 24, 48 V DC Notes: 1. PC board type and 1 coil latching type are manufactured by lot upon receipt of order. 2. Certified by UL, CSA and TUV TYPES Contact arrangement Nominal coil voltage 3V DC 5V DC 6V DC 12V DC 24V DC 48V DC 3V DC 5V DC 6V DC 12V DC 24V DC 48V DC 2 Form C 4 Form C Single side stable Part No. SP2-DC3V SP2-DC5V SP2-DC6V SP2-DC12V SP2-DC24V SP2-DC48V SP4-DC3V SP4-DC5V SP4-DC6V SP4-DC12V SP4-DC24V SP4-DC48V 2 coil latching Part No. SP2-L2-DC3V SP2-L2-DC5V SP2-L2-DC6V SP2-L2-DC12V SP2-L2-DC24V SP2-L2-DC48V SP4-L2-DC3V SP4-L2-DC5V SP4-L2-DC6V SP4-L2-DC12V SP4-L2-DC24V SP4-L2-DC48V Standard packing (2 Form C): Carton: 20 pcs.; Case: 200 pcs. Standard packing (4 Form C): Carton: 10 pcs.; Case: 100 pcs. Note: PC board type and 1 coil latching type are manufactured by lot upon receipt of order. * Terminal sockets and mounting boards available. RATING 1. Coil data 1) Single side stable Nominal operating current [10%] (at 20C 68F) Coil resistance [10%] (at 20C 68F) 3V DC 100mA 30 5V DC 6V DC 12V DC 24V DC 48V DC 60.2mA 50mA 25mA 12.5mA 6.2mA 83 120 480 1,920 7,700 Nominal coil voltage Pick-up voltage (at 20C 68F) Drop-out voltage (at 20C 68F) 70%V or less of nominal voltage (Initial) 10%V or more of nominal voltage (Initial) Set voltage (at 20C 68F) Reset voltage (at 20C 68F) Nominal operating power Max. applied voltage 300mW 150%V of nominal voltage 2) 2 coil latching Nominal coil voltage Nominal operating current [10%] (at 20C 68F) Set coil Reset coil Coil resistance [10%] (at 20C 68F) Set coil Reset coil 3V DC 100mA 100mA 30 30 5V DC 6V DC 12V DC 24V DC 48V DC 60.2mA 50mA 25mA 12.5mA 6.2mA 60.2mA 50mA 25mA 12.5mA 6.2mA 83 120 480 1,920 7,680 83 120 480 1,920 7,680 70%V or less of nominal voltage (Initial) 70%V or less of nominal voltage (Initial) -2- Nominal operating power Set coil Reset coil 300mW 300mW Max. applied voltage 150%V of nominal voltage ASCTB208E 201606-T SP 2. Specifications Characteristics Contact Rating Electrical characteristics Item Initial contact pressure Arrangement Contact resistance (Initial) Contact material Nominal switching capacity (resistive load) Max. switching power (resistive load) Max. switching voltage Max. switching current Nominal operating power Min. switching capacity (reference value)*1 Specifications 2 Form C: Approx. 0.392 N (40 g 1.41 oz), 4 Form C: Approx. 0.196 N (20 g 0.71 oz) 2 Form C, 4 Form C Max. 30 m (By voltage drop 6 V DC 1A) Stationary contact: Au flashed AgSnO2 type, Movable contact: AgSnO2 type 2 Form C: 15 A 250 V AC, 4 Form C: 10 A 250 V AC 2 Form C: 3,750 VA, 300 W, 4 Form C: 2,500 VA, 300 W 2 Form C, 4 Form C: 250 V AC, 30 V DC (48V DC: Max. 2A) 2 Form C: 15 A (AC) 10 A (DC), 4 Form C: 10 A 300mW (Single side stable, 2 coil latching) 100 mA 5V DC Insulation resistance (Initial) (25C, 50% relative humidity) Min. 1,000M (at 500V DC) Measurement at same location as "Breakdown voltage" section. Between open contacts Between contact and coil Between contact sets Breakdown voltage (Initial) Operate time [Set time] (at 20C 68F) (Initial) Release time [Reset time] (at 20C 68F) (Initial) Functional Destructive Functional Vibration resistance Destructive Mechanical Shock resistance Mechanical characteristics Expected life Conditions Electrical (resistive load) Conditions for operation, transport and storage*2 Max. operating speed Unit weight 1,500 Vrms for 1 min. (Detection current: 10 mA) 3,000 Vrms for 1 min. (Detection current: 10 mA) 3,000 Vrms for 1 min. (Detection current: 10 mA) Max. 30 ms [Max. 30 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.) Max. 20 ms [Max. 30 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode) Min. 392 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10s.) Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.) 10 to 55 Hz at double amplitude of 3 mm (Detection time: 10s.) 10 to 55 Hz at double amplitude of 3 mm Min. 5x107 (at 180 times/min.) 2 Form C: Min. 105 (15 A 250 V AC [at 20 times/min.]), Min. 105 (10 A 30 V DC [at 20 times/min.]) 4 Form C: Min. 105 (15 A 250 V AC [at 20 times/min.]), Min. 105 (10 A 30 V DC [at 20 times/min.]) Ambient temperature: -50C to +60C -58F to +140F; Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) 20 times/min. (at rated load) 2 Form C: 50 g 1.76 oz; 4 Form C: 65 g 2.29 oz Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. *2. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage conditions in NOTES. REFERENCE DATA 1.-(1) Coil temperature rise (2 Form C type) 1.-(2) Coil temperature rise (4 Form C type) Tested sample: SP2-DC24V Tested sample: SP4-DC24V Ambient temperature: 27 to 29C 81 to 84F 50 40 15 A 30 10 A 5A 20 0A 10 0 Temperature rise, C Temperature rise, C 50 40 10 A 30 5A 0A 20 10 19.2 21.6 24.0 26.4 28.8 31.2 33.6 36.0 Coil applied voltage, V 0 19.2 21.6 24.0 26.4 28.8 31.2 33.6 36.0 Coil applied voltage, V -3- ASCTB208E 201606-T SP N.C. N.O. Contact resistance, m Pick-up/drop-out voltage, V 2. Electrical life (SP2, 15 A 250 V AC resistive load) Change of pick-up and drop-out voltage Change of contact resistance Pick-up voltage 15 Max. x Min. 10 Drop-out voltage 5 0 2 3 4 5 6 7 8 9 Max. 10 x Max. x Min. Min. 5 Max. x Min. 1 15 0 10 1 2 3 No. of operations, x104 4 5 6 7 8 9 10 No. of operations, x104 N.C. N.O. Pick-up voltage 15 Contact resistance, m Pick-up/drop-out voltage, V 3. Electrical life (SP4, 10 A 250 V AC resistive load) Change of pick-up and drop-out voltage Change of contact resistance Max. x Min. 10 Drop-out voltage 5 0 Max. x Min. 1 2 3 4 5 6 7 8 9 No. of operations, x104 1 .039 30 Max. 20 x Min. 0 1 2 3 4 5 6 7 8 9 10 No. of operations, x104 The CAD data of the products with a 2 Form C 1) Plug-in terminal CAD Data 40 10 10 DIMENSIONS (mm inch) 50 CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/ 2) PC board type CAD Data External dimensions Schematic (Bottom view) External dimensions Single side stable type 50 1.969 0.5 .020 10 .394 25.6 1.008 15.24 .600 20.5 .807 2 .079 10.16 10.16 10.16 10.16 .400 .400 .400 .400 0.5 .020 5.5 .217 15.24 .600 6 7 2 8 9 10 (Deenergized condition) 2 coil latching type 1 PC board pattern (Bottom view) 10-2.5 dia. 10-.098 dia. 7.15 .281 10.16 10.16 10.16 10.16 .400 .400 .400 .400 4.75 .187 5 1.5 .059 General tolerance: 0.3 .012 20.5 .807 1.5 .059 1 5 6 7 9 10 SET 2 8 3 RST 4 (Reset condition) FASTON #187 General tolerance: 0.3 .012 15.24 .600 10.16 10.16 10.16 10.16 .400 .400 .400 .400 Tolerance: 0.1 .004 Diagram shows the "reset" position when terminals 3 and 4 are energized. Energize terminals 1 and 2 to transfer contacts. -4- ASCTB208E 201606-T SP 4 Form C 1) Plug-in terminal CAD Data 1 .039 2) PC board type CAD Data External dimensions Schematic (Bottom view) External dimensions Single side stable type 50 1.969 0.5 .020 10 .394 36.8 1.449 15.24 .600 11 12 13 1 5 6 7 2 8 9 10 14 15 16 20.5 .807 7.62 .300 1.5 .059 2 .079 10.16 10.16 10.16 10.16 .400 .400 .400 .400 7.62 .300 0.5 .020 5.5 .217 7.62 .300 15.24 .600 7.62 .300 General tolerance: 0.3 .012 PC board pattern (Bottom view) 20.5 .807 1.5 .059 (Deenergized condition) 2 coil latching type 16-2.5 dia. 16-.098 dia. 7.15 .281 1 7.62 .300 10.16 10.16 10.16 10.16 .400 .400 .400 .400 4.75 .187 11 12 13 5 6 7 8 9 10 14 15 16 SET 15.24 .600 2 7.62 .300 General tolerance: 0.3 .012 3 RST 4 (Reset condition) 10.16 10.16 10.16 10.16 .400 .400 .400 .400 Tolerance: 0.1 .004 Diagram shows the "reset" position when terminals 3 and 4 are energized. Energize terminals 1 and 2 to transfer contacts. SAFETY STANDARDS Item 2 Form C File No. E43028 4 Form C E43028 UL (Recognized) Contact rating 15A 250V AC General Use 1/2HP 125, 250V AC 10A 30V DC 10A 250V AC General Use 1/3HP 125, 250V AC 10A 30V DC File No. LR26550 LR26550 CSA (Certified) Contact rating 15A 250V AC General Use 1/2HP 125, 250V AC 10A 30V DC 10A 250V AC General Use 1/3HP 125, 250V AC 10A 30V DC File No. B 11 08 13461 308 B 11 08 13461 308 TUV (Certified) Contact rating 15A 250V AC (cos =1.0) 10A 30V DC (0ms) -- 10A 250V AC (cos =1.0) 10A 30V DC (0ms) -- Cycles 105 105 -- 105 105 -- NOTES 1. For cautions for use, please read "GENERAL APPLICATION GUIDELINES". -5- ASCTB208E 201606-T