REV. NOV 03, 2003
XWD DC-DC Series Data Sheet
Dual-Output, 180 Watts
Page 1 of 3
XWD dual-output DC-DC converters are high powered converters that cover a wide range of applications. Available
input voltages include 12V, 24V, 40V, and 48V. Output voltages are available from 5V to 15V. The XWD features
remote sense leads for accurate point of load regulation. For single and triple-output high power
solutions, see the XWS and XWT Series of converters.
High power package
Wide input range
Trim and enable
Remote Sense Pins
500V Isolation
Description
Features
Output
Setpoint Accuracy ±1%
Line Regulation VinMin. - VinMax., IoutRated ±1% Vout
Load Regulation IoutMin. - IoutMax., VinNom. ±1% Vout
Minimum Output Current 10 %
Dynamic Regulation, Loadstep 25% Iout
Pk Deviation 4% Vout
Settling Time 500 µs
Voltage Trim Range ±10%
Turn-On Time 10 ms
Remote Shutdown Positive Logic
Switching Frequency 200 kHz
Isolation
Input - Output 500 VDC
Temperature Coefficient ±0.02%/°C
Case Temperature
Operating Range -25 To +85°C††
Storage Range -40 To +125°C
Thermal Shutdown Range 105 - 115°C
Humidity Max., Non-Condensing 95%
Vibration, 3 Axes, 5 Min Each 5 g, 10 - 55 Hz
MTBF(Bellcore TR-NWT-000332) Consult Factory
Safety Consult Factory
Weight (Approx.) 15.4 oz
General
Technical Specifications
Voltage Range
12 VDC Nominal 10 - 20 VDC
24 VDC Nominal 18 - 36 VDC
48 VDC Nominal 36 - 72 VDC
40 VDC Nominal (Wide Input) 20 - 60 VDC
Input Ripple Current 20% Iin Max.
Reverse Input Current 100% Iin Max.
Input
XWD2405
65
70
75
80
85
90
10 20 30 40 50 60 70 80 90 100
LOAD %
EFFICIENCY %
(18v)
(24v)
(36v)
Efficiency vs. Load (24V Input)
70
75
80
85
90
10 20 30 40 50 60 70 80 90 100
LOAD %
EFFICIENCY %
XWD4812
XWD4815
Efficiency vs. Load (48V Input)
Notes
† MTBF predictions may vary slightly from model to model.
†† Industrial temp range of -40 to +85°C available.
Specifications typically at 25°C, normal line, and full load, unless otherwise
stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with
commercial wave-soldering equipment.
Safety: Fusing Recommended.
+ See following two pages for Terminal Strip Option
MODEL INPUT VOLTAGE INPUT VOLTAGE MAXIMUM INPUT OUTPUT RATED OUTPUT RIPPLE & NOISE TYPICAL
(VOLTS) RANGE (VOLTS) CURRENT (AMPS)* VOLTAGE (VOLTS) CURRENT (AMPS) pk-pk (mV) EFFICIENCY**
XWD1205 12 10-20 14.0 ±5 ±10 50 79%
XWD1212TS 12 10-20 16.9 ±12 ±5.2 120 81%
XWD1215 12 10-20 16.7 ±15 ±4.15 150 82%
XWD2405 24 18-36 11.3 ±5 ±15 50 82%
XWD2412 24 18-36 13.3 ±12 ±7.5 120 83%
XWD2415 24 18-36 13.3 ±15 ±6 150 83%
XWD4805 48 36-72 5.5 ±5 ±15 50 84%
XWD4812 48 36-72 6.5 ±12 ±7.5 120 85%
XWD4815 48 36-72 6.5 ±15 ±6 150 85%
XWD6005 40 20-60 10.3 ±5 ±15 50 80%
XWD6012 40 20-60 12.2 ±12 ±7.5 120 81%
XWD6015 40 20-60 12.2 ±15 ±6 150 81%
NOTES:
* Maximum input current at minimum input voltage, maximum rated output power.
** At nominal Vin, rated output.
REV. NOV 03, 2003
Dual-Output, 180 Watts
Page 2 of 3
XWD DC-DC Series Data Sheet
Mechanical Drawing
Pin Function
1 No Pin
2-V
in
3-V
in
4+V
in
5+V
in
6 Enable
7 Case
8 -V1 Sense
9 -V1out
10 +V1out
11 +V1 Sense1
12 - V2out
13 Trim
14 + V2out
Tolerances
Inches: (Millimeters)
.XX ± 0.040 .X ± 1.0
.XXX ± 0.010 .XX ± 0.25
Pin:
± 0.002 ± 0.05
(Dimensions as listed unless otherwise
specified.)
#4-40 THREADED INSERTS 4PLS.
5.50"
(139.7mm)
1.875"(47.6mm)
2.250"(57.2mm)
2.625"(66.7mm)
0.750"(19.1mm)
1.125"(28.6mm)
1.500"(38.1mm)
0.375"(9.5mm)
0
-0.375"(-9.5mm)
-0.625"(-15.9mm)
3.50"
(88.9mm)
BOTTOM VIEW
(23.4mm)
0.92"
(1.0mm)
DIA 0.040" 13PL.
8
9
10
12
11
13
14
1
2
3
5
4
6
7
0
-0.60"
(-15.2mm)
4.300"
(109.2mm)
Note:
Thermal impedance data is dependent on
many environmental factors. The exact
thermal performance should be validated
for specific application.
Thermal Impedance
Natural convection 2.5 °C/W
100 LFM 2.1 °C/W
200 LFM 1.7 °C/W
300 LFM 1.3 °C/W
400 LFM 1.1 °C/W
Model numbers highlighted in yellow or shaded are not recommended for new designs.
Model Selection
REV. NOV 03, 2003
OPTIONS
Page 3 of 3
This page is offered as a reference. Consult factory for actual availability of options. When ordering
equipment options, use the following suffix information. Select preferred option(s) and add the suffix to the
model number. Ordering option examples are located below the options table.
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president
of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
OPTION SUFFIX APPLICABLE SERIES REMARKS
Negative Logic N HAS, HBD, HBS, HES, HLS, HLD, LES, TTL "Low" Turns Module ON
QBS, QES, QLS, TES, TQD TTL "High" Turns Module OFF
Lucent-Compatible Trim T HAS, HBD, HBS, HES, HLS, QBS, QES,
QLS
Trim 1 IAS, LES
Enable 2 IAD, IAS, LES, SMS
Trim and Enable 3 IAS, LES
Pin Length and Heat Sink Options Standard Pin Length is 0.180" (4.6mm)
0.110" (2.8mm) Pin Length 8 All Leaded Models
0.150" (3.8mm) Pin Length 9 All Leaded Models
0.24" (6.1mm) Horizontal Heat Sink 1H All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks Includes Thermal Pad
(Except HLS, HLD, QLS, TLD, and TKD Packages)
0.24" (6.1mm) Vertical Heat Sink 1V All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks Includes Thermal Pad
(Except HLS, HLD, QLS, TLD, and TKD Packages)
0.45" (11.4mm) Horizontal Heat Sink 2H All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks Includes Thermal Pad
(Except HLS, HLD, QLS, TLD, and TKD Packages)
0.45" (11.4mm) Vertical Heat Sink 2V All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks Includes Thermal Pad
(Except HLS, HLD, QLS, TLD, and TKD Packages)
0.95" (24.1mm) Horizontal Heat Sink 3H All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks Includes Thermal Pad
(Except HLS, HLD, QLS, TLD, and TKD Packages)
0.95" (24.1mm) Vertical Heat Sink 3V All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks Includes Thermal Pad
(Except HLS, HLD, QLS, TLD, and TKD Packages)
Example Options:
HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent-compatible trim, and 0.95” vertical heat sink.
LES015YJ-3N = LES015YJ with optional trim and enable, negative logic.
QBS066ZG-AT8 = QBS066ZG-A with Lucent-compatible trim and 0.110” pin length.