Panel Mount Datasheet HAC Series * Load Voltage range 24 to 660 VAC * Output rating up to 150 Arms * Zero Voltage or Instantaneous Turn-on options * AC or DC input control options * Locking Input Connector * Optional Transient Protection & installed Thermal Pad PRODUCT SELECTION Control Voltage 150 A HAC24D150 ,HAC60D150 HAC24B150 ,HAC60B150 HAC24A150 ,HAC60A150 3-32 VDC 90-140 VAC 150-270 VAC AVAILABLE OPTIONS Control Voltage A: 150-270 VAC B: 90-140 VAC D: 4-32 VDC Series HAC 24 A Operating Voltage 24: 24-280 VAC 60: 48-660 VAC 150 Overvoltage Protection Blank: Not Included P: Included (6) P Rated Load Current 150: 150 Amps H Switching Type Blank: Zero Voltage Turn-On -10: Instantaneous Turn-On (5) -10 Thermal Pad Blank: Not Included H: Included Required for valid part number For options only and not required for valid part number OUTPUT SPECIFICATIONS (1) Description Operating Voltage (47-63Hz) [Vrms] Transient Overvoltage [Vpk] Maximum Off-State Leakage Current @ Rated Voltage [mA] Maximum Off-State dv/dt @ Maximum Rated Voltage [V/Sec] Maximum Load Current [Arms](2) Minimum Load Current [Arms] Maximum Surge Current [Apk] 1 Cycle 50/60 Hz Maximum It for fusing (10msec)/(8.33msec)[Asec] Maximum On-State Voltage Drop @ Rated Current [Vrms] Thermal Resistance Juncti on to Case (Rjc) [C/W] Minimum Power Factor (with Maximum load) Wire Size max (solid/stranded) [AWG/ IEC mm] (3) Output Terminal Nut Torque Range [in lb (Nm) HP Rating UL 508/IEC60957 [HP (KW)]: 240 VAC HP Rating UL 508/IEC60947 [HP (KW)]: 480 VAC Do not forget to visit us at: www.crydom.com Copyright (c) 2016 Crydom Inc. Specifications subject to change without notice. HAC24x150 HAC60x150 24-280 600 1 500 150 0.15 1670/1750 13950/12709 1.15 0.15 0.5 2/0 / 67.4 225-300 (25.4-33.9) 10 (7.5) N/A 48-660 1200 1 500 150 0.15 1670/1750 13950/12709 1.15 0.15 0.5 2/0 / 67.4 225-300 (25.4-33.9) N/A 25 (18.75) Panel Mount Datasheet INPUT SPECIFICATIONS (1) Description Control Voltage Range Minimum Turn-Off Voltage Must Turn-Off Voltage Minimum Input Current (for on-state) [mA] Maximum Input Current [mA] Nominal Input Impedance [Ohms] Maximum Turn-On Time [msec] (4) Maximum Turn-Off Time [msec] HACxxD150 HACxxA150 4-32 VDC (10) 4 VDC 1 VDC 9 15 Current Regulated 1/2 Cycle 1/2 Cycle 150-270 VAC 150 VAC 10 VAC 6 10 Current Regulated HACxxB150 90-140 VAC 90 VAC 10 VAC 7 12 Current Regulated 20 30 20 30 GENERAL SPECIFICATIONS (1) Parameters Description Dielectric Strength, Input/Output (50/60Hz) Dielectric Strength, Input/Output/Base (50/60Hz) Minimum Insulation Resistance (@ 500 V DC) Maximum Capacitance, Input/Output Ambient Operating Temperature Range Ambient Storage Temperature Range Weight (typical) lbs/grams Housing Material SSR Mounting Torque Range [in lbs/Nm] LED Input Status Indicator (color) Humidity Input Terminal (7) 3750 Vrms 2500 Vrms 10 9 Ohm 10 pF -30 to 80 C -40 to 125 C 0.75/340.2 PBT 30% GF, UL 94 V-0 18-20 (2-2.2) YES (Green) 85% non-condensing Detachable barrier strip GENERAL NOTES (1) All parameters at 25C unless otherwise specified. (2) Heat sinking required, see derating curves. (3) TRM3/0 lug terminal must be used. (4) Turn-on time for Instantaneous turn-on versions is 0.02 msec. (5) Instantaneous turn-on version is not recommended for capacitive loads. Use zero turn-on only. (6) Output will self-trigger (450-600Vpk for HAC24 and 900-1200Vpk for HAC60), not suitable for capacitive loads. (7) Connector/Plug Not included. See Suggested Mating Connectors/Plugs (8) Elective Overvoltage Protection, "P" option. (9) Load can be wired to either SSR output terminal 1 or 2. (10) Increase minimum voltage by 1V for operations from -20 to -30C WIRING DIAGRAM AC V Load L2 ( ) Input Current vs Input Voltage Standard Regulated "DC" Inputs L1 ( ) LOAD SIDE L1 L2 S O L I D S TAT E C O N TA C T O R HAC60D150 INPUT STATUS 4-32 VDC Input Current (mA) 25 20 15 10 5 0 0 5 10 15 20 DC Input Voltage (- / ) (+ / ) Do not forget to visit us at: www.crydom.com Copyright (c) 2016 Crydom Inc. Specifications subject to change without notice. 25 30 Panel Mount Datasheet MECHANICAL SPECIFICATIONS Tolerances: 0.02 in / 0.5 mm All dimensions are in: inches [millimeters] Standard Stud 0.375 [9.52] -24 LOAD SIDE L1 L2 2.90 [73.7] 1.87 [47.6] INPUT STATUS Mounting Hole/Slot 0.20 [5.0] DIA. 2.51 [63.7] 3.62 [92.0] 4.12 [104.6] 1.70 [43.2] Max 1.00 [25.4] 0.82 [20.8] SUGGESTED MATING CONNECTORS/PLUGS FRONT WIRE ENTRY Molex: 0395332002 Phoenix: MVSTBW 2,5/ 2 -ST-5,08 Do not forget to visit us at: www.crydom.com (7) RIGHT ANGLE REAR WIRE ENTRY Molex: 0395300002 Phoenix: MSTB 2,5/ 2 -ST-5,08 Molex: 39533 -3002 Phoenix: MVSTBR 2,5/ 2 -ST-5,08 Copyright (c) 2016 Crydom Inc. Specifications subject to change without notice. Panel Mount Datasheet SURGE CURRENT INFORMATION Surge Current (Amp) 150 A 1800 1600 1400 1200 1000 800 600 400 200 0 0.01 0.1 1 Surge Duration (Secs) 10 Non repetitive peak surge current at Tj initial 40C THERMAL DERATE INFORMATION (2) HACxxA150 0.25C/W 0.36C/W HACxxB150,HACxxD150 0.25C/W 0.50C/W Load Current (Amps) Load Current (Amps) 0.50C/W 150 150 125 100 75 50 25 0 0.36C/W 20 30 40 50 60 70 Ambient Temperature (C) Do not forget to visit us at: www.crydom.com 80 Copyright (c) 2016 Crydom Inc. Specifications subject to change without notice. 125 100 75 50 25 0 20 30 40 50 60 70 Ambient Temperature (C) 80 Panel Mount Datasheet EQUIVALENT CIRCUIT BLOCK DIAGRAM Diagram: HAC AC control L2 AC AC/DC Converter AC Current Limiter Trigger Circuit (8) AC (9) AC L1 Diagram: HAC DC control L2 -DC Trigger Circuit +DC (8) (9) L1 Current Limiter AC AC ACCESSORIES Recommended Accessories Hardware Kit HK1 Heat Sink Part No. Thermal Resistance Lug Terminal [C/W] HS053 0.5 HS033 0.36 HS023 0.25 Thermal Pad TRM3/0 HSP-5 AGENCY APPROVALS Agency Approvals Designed in accordance with the requirements of IEC 62314 IEC 61000-4-2 : Electrostatic Discharge: Level 3 IEC 61000-4-4 : Electrically Fast Transients: Level 3 IEC 61000-4-5 : Electricsl Surges: Level 3 E 116949 Rev. 091316 Do not forget to visit us at: www.crydom.com Copyright (c) 2016 Crydom Inc. Specifications subject to change without notice. Panel Mount Datasheet DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH. * Disconnect all power before installing or working with this equipment. * Verify all connections and replace all covers before turning on power. Failure to follow these instructions will result in death or serious injury. RIESGO DE DESCARGA ELECTRICA O EXPLOSION. * Desconectar todos los suministros de energia a este equipo antes de trabajar con este equipo. * Verificar todas las conexiones y colocar todas las tapas antes de energizer el equipo. El incumplimiento de estas instrucciones puede provocar la muerte o lesiones serias. RISQUE DE DESCHARGE ELECTRIQUE OU EXPLOSION * Eteindre toutes les sources d'energie de cet appareil avant de travailler dessus de cet appareil * Verifier tous connections, et remettre tous couverts en olace avant de mettre sous De non-suivi de ces instructions provoquera la mort ou des lesions serieuses serieuses. GEFAHR EINES ELEKTRISCHE N SCHLAGES ODER EINER EXPLOSION. * Stellen Sie jeglichen Strom ab, der dieses Gerat versorgt, bevor Sie an dem Gerat Arbeiten durchfuhren * Vor dem Drehen auf Energie alle Anschlusse uberprufen und alle Abdeckungen ersetzen. Unterlassung dieser Anweisungen konnen zum Tode oder zu schweren Verletzungen fuhren. RISCHIO DI SCOSSA ELETTRICA O DELL'ESPLOSIONE. * Spenga tutta l'alimentazione che fornisce questa apparecchiatura prima di lavorare a questa apparecchiatura * * Verificare tutti i collegamenti e sostituire tutte le coperture prima dell'accensione L'omissione di queste istruzioni provochera la morte o lesioni serie WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE RISQUE DE DOMMAGE MATERIEL ET DE SURCHAUFFE DU BOITIER GEFAHR VON MATERIALSCHADEN UND GEHAUSEERHITZUNG * The product's side panels may be hot, allow the product to cool before touching. * Follow proper mounting instructions including torque values. * Do not allow liquids or foreign objects to enter this product. * Les panneaux lateraux du produit peuvent etre chauds. Laisser le produit refroidir avant de le toucher. * Respecter les consignes de montage, et notamment les couples de serrage. * Ne pas laisser penetrer de liquide ni de corps etrangers a l'interieur du produit. * Die Seitenwande konnen hei sein. Lassen Sie das Produkt abkuhlen, bevor Sie es beruhren. * Beachten Sie die Montageanweisungen, * Fuhren Sie keine Flussigkeiten oder Fremdkorper in das Produkt ein. Le non-respect de cette directive peut entrainer, Failure to follow these instructions can result in des lesions corporelles graves ou des serious injury, or equipment damage. dommages materiels. Die Nichtbeachtung dieser Anweisung kann Korperverletzung oder Materialschaden zur Folge haben. RIESGO DE DANOS MATERIALES Y DE SOBRECALENTAMIENTO DE LA UNIDAD RISCHIO DI DANNI MATERIALI E D'INVOLUCRO CALDO * Los paneles laterales del producto pueden estar calientes. Esperar que el producto se enfrie antes de tocarlo. * Respetar las instrucciones de montaje, y en particular los pares de apretado. * No dejar que penetren liquidos o cuerpos extranos en el producto. * I pannelli laterali dell'apparecchio possono scottare; lasciar quindi raffreddare il prodotto prima di toccarlo. * Seguire le istruzioni di montaggio corrette. * Non far entrare liquidi o oggetti estranei in questo apparecchio. Si no se respetan estas precauciones pueden producirse graves lesiones, danos materiales. La mancata osservanza di questa precauzione puo causare gravi rischi per l'incolumita personale o danni alle apparecchiature. Do not forget to visit us at: www.crydom.com Copyright (c) 2016 Crydom Inc. Specifications subject to change without notice. * * * Panel Mount Datasheet ANNEX - ENVIROMENTAL INFORMATION The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People's Republic of China Electronic Industry Standard SJ/T11364 - 2006, Marking for Control of Pollution Caused by Electronic Information Products. Part Name Toxic or hazardous Substance and Elements Lead (Pb) Mercury (Hg) Cadmium (Cd) Hexavalent Chromium (Cr (VI)) Polybrominated biphenyls (PBB) Polybrominated diphenyl ethers (PBDE) Semiconductor die Solder - SJ/T11364 - 2006, (Pb) (Hg) (Cd) (Cr (VI)) 50 Do not forget to visit us at: www.crydom.com Copyright (c) 2016 Crydom Inc. Specifications subject to change without notice. (PBB) (PBDE)