134 Page 1 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE ©2004 TELEDYNE RELAYS
www.teledynerelays.com 134/0704/Q1
ESTABLISHED RELIABILITY
SERIES
134
CENTIGRID®
ESTABLISHED RELIABILITY
RELAYS
SENSITIVE DPDT
DESCRIPTION
The 134 sensitive Centigrid®relay retains the same features as the 114
standard Centigrid®relay with only a minimal increase in profile height (.375
in.). Its .100-inch grid spaced terminals, which preclude the need for spreader
pads, and its low profile make the 134 relay ideal for applications where high
packaging density is important.
The following unique construction features and manufacturing techniques
provide excellent resistance to environmental extremes and overall high
reliability:
All welded construction.
Unique uni-frame design providing high magnetic efficiency and mechanical
rigidity.
High force/mass ratios for resistance to shock and vibration.
Advanced cleaning techniques provide maximum assurance of internal
cleanliness.
Precious metal alloy contact material with gold plating assures excellent
high current and dry circuit switching capabilities.
The Series 134D and 134DD have internal discrete silicon diodes for coil
suppression and polarity reversal protection.
The sensitive 134 Centigrid®relay has a high resistance coil, thus requiring
extremely low operating power (200 mw typical). The advantages of reduced
heat dissipation and power supply demands are a plus.
By virtue of its inherently low intercontact capacitance and contact circuit
losses, the 134 relay has proven to be an excellent ultraminiature RF switch
for frequency ranges well into the UHF spectrum. A typical RF application for
the Centigrid®relay is in handheld radio transceivers, wherein the combined
features of good RF performance, small size, low coil power dissipation and
high reliability make it a preferred method of Transmit-Receive switching (see
Figure 1).
INTERNAL CONSTRUCTION
SERIES
DESIGNATION RELAY TYPE
134 DPDT basic relay
134D DPDT relay with internal diode for coil transient suppression
134DD DPDT relay with internal diodes for coil transient suppression and polarity
reversal protection
UPPER
STATIONARY
CONTACT
LOWER
ST
ATIONARY
CONTACT MOVING
CONTACT
UNI-FRAME
ARMA
TURE
ENVIRONMENTAL AND
PHYSICAL SPECIFICATIONS
Temperature
(Ambient) –65°C to +125°C
Vibration
(General Note 1) 30 g’s to 3000 Hz
Shock
(General Note 1)
75 g’s,
6 msec, half-sine
Acceleration 50 g’s
Enclosure Hermetically sealed
Weight 0.15 oz. (4.3g) max.
PERFORMANCE CURVES
(NOTE 2)
©2003 TELEDYNE RELAYS SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE 134 Page 2
www.teledynerelays.com 134/1203/Q1
ESTABLISHED RELIABILITY
SERIES 134
GENERAL ELECTRICAL SPECIFICATIONS (–65°C to +125°C unless otherwise noted) (Notes 2 & 3)
DETAILED ELECTRICAL SPECIFICATIONS (–65°C to +125°C unless otherwise noted) (Note 3)
Contact Arrangement 2 Form C (DPDT)
Rated Duty Continuous
Contact Resistance 0.1 ohm max. before life; 0.2 ohm max. after life at 1A/28Vdc (measured 1/8" from header)
Contact Load Ratings (DC)
(See Fig. 2 for other DC
resistive voltage/current ratings)
Resistive: 1 Amp/28Vdc
Inductive: 200 mA/28Vdc (320 mH)
Lamp: 100 mA/28Vdc
Low Level: 10 to 50 μA/10 to 50mV
Contact Load Ratings (AC) Resistive: 250 mA/115Vac, 60 and 400 Hz (Case not grounded)
100 mA/115Vac, 60 and 400 Hz (Case grounded)
Contact Life Ratings
10,000,000 cycles (typical) at low level
1,000,000 cycles (typical) at 0.5A/28Vdc resistive
100,000 cycles min. at all other loads specified above
Contact Overload Rating 2A/28Vdc Resistive (100 cycles min.)
Contact Carry Rating Contact factory
Coil Operating Power 200 milliwatts typical at nominal rated voltage @ 25°C
Operate Time 4.0 msec max. at nominal rated coil voltage
Release Time 134 Series: 2.0 msec max. 134D, 134DD Series: 7.5 msec max.
Contact Bounce 1.5 msec max.
Intercontact Capacitance 0.4 pf typical
Insulation Resistance 10,000 megohms min. between mutually isolated terminals
Dielectric Strength Atmospheric pressure: 500 Vrms/60Hz 70,000 ft.: 125 Vrms/60Hz
Negative Coil Transient (Vdc) 134D, 134DD 1.0 max
Diode P.I.V. (Vdc) 134D, 134DD 100 min.
BASE PART
NUMBERS
(See Note 8 for full P/N example)
134-5
134D-5
134DD-5
134-6
134D-6
134DD-6
134-9
134D-9
134DD-9
134-12
134D-12
134DD-12
134-18
134D-18
134DD-18
134-26
134D-26
134DD-26
Coil Voltage (Vdc) Nom. 5.0 6.0 9.0 12.0 18.0 26.5
Max. 7.5 10.0 15.0 20.0 30.0 40.0
Coil Resistance
(Ohms ±10% @25°C)
134, 134D 100 200 400 800 1600 3200
134DD (Note 4) 64 125 400 800 1600 3200
Coil Current (mAdc @25°C)
(134DD Series)
Min. 56.8 36.3 18.1 12.5 9.6 7.2
Max. 78.1 48.9 23.6 16.0 12.2 9.0
Pick-up Voltage (Vdc, Max.) 134, 134D 3.5 4.5 6.8 9.0 13.5 18.0
134DD 3.7 4.8 8.0 11.0 14.5 19.0
Drop-out Voltage (Vdc)
134, 134D Min. 0.12 0.18 0.35 0.41 0.59 0.89
Max. 2.5 3.2 4.9 6.5 10.0 13.0
134DD Min. 0.7 0.8 0.9 1.0 1.1 1.3
Max. 2.6 3.0 4.5 5.8 9.0 13.0
0
.1
.2
.3
.4
10
20
30
40
50
60
70
.01 0.5 .1 .5 1.0
FREQUENCY (GHz)
FIGURE 1
TYPICAL RF PERFORMANCE
INSERTION LOSS
RETURN LOSS (VSWR)
ISOLATION ACROSS CONTACTS
ISOLATION ACROSS POLES
1.92
1.22
1.07
1.02
1.01
1.00
1.00
VSWR
300
250
200
150
100
50
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
LOAD CURRENT (AMPS DC)
FIGURE 2
TYPICAL DC CONTACT RATING (RESISTIVE)
LOAD VOLTAGE (VDC)
dB
134 Page 3 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE ©2004 TELEDYNE RELAYS
www.teledynerelays.com 134/0704/Q1
ESTABLISHED RELIABILITY
CASE DETAIL
.375 (9.53)
SQ. MAX.
.335 (8.51)
SQ. MAX.
.375 (9.53) MAX.
DIMENSIONS ARE SHOWN IN INCHES (MILLIMETERS)
TERMINAL LOCATIONS
(Viewed from Terminals; Numbers for Reference Only)
.017 (.43) DIA.
+.002 (.05)
–.001 (.03)
WIRE LEAD .750 (19.05) MIN.
PIN: .187 (1.75) ±.010 (.25)
(See Note 5)
.031 ±.003
(.79 ±.08) .035 ±.010
(.89 ±.25)
.100 ±.010
(2.54 ±.25)
TYP 8 PLACES
4
7
6
5
81
2
3
OUTLINE DIMENSIONS
GENERAL NOTES
1. Relay contacts will exhibit no chatter in excess of 10 μsec or transfer in excess of 1 μsec.
2. “Typical” characteristics are based on available data and are best estimates. No on-going
verification tests are performed.
3. Unless otherwise specified, parameters are initial values.
4. For reference only. Coil resistance not directly measurable at relay terminals due to
internal series diode in 134DD only.
5. Unless otherwise specified, relays will be supplied with either gold-plated or solder-
coated leads.
6. The slash and characters appearing after the slash are not marked on the relay.
7. Screened HI-REL versions available. Contact factory.
8.
SCHEMATIC DIAGRAMS
Teledyne Part Numbering System for T
2
R
®
Established Reliability Relay
ER 134 Z M4 - 26 A / S Q
Established Reliability
Designator
Pad Option
(See Appendix)
Relay Series
Ground Pin Option
(See Appendix)
Q= Solder-Coated Leads
G= Gold-Plated Leads
(Notes 5 and 6)
S= .187" leads
(Note 6)
Coil Voltage
Screening and Reliability
Level
Teledyne Part Numbering System for Military Qualified (JAN) Relays
J 134 Z M4 - 26 P L
Military (JAN)
Designator
Pad Option
(See Appendix)
Relay Series
Ground Pin Option
(See Appendix)
Terminal Variant
P = 0.187"
Coil Voltage
Screening and Reliability
Level
SCHEMATICS ARE VIEWED
FROM TERMINALS
134
134D
134DD
SERIES 134
Pad designation and
bottom view dimensions Height For use with the following: Dim. H
Max.
“M4” Pad for TO-5
ER411T
ER412, ER412D, ER412DD .295 (7.49)
712, 712D, 712TN,
RF300, RF310, RF320 .300 (7.62)
ER420, ER422D, ER420DD, 421,
ER421D, ER421DD, ER422, ER422D,
ER422DD, 722, 722D, RF341
.305 (7.75)
ER431T, ER432T,
ER432, ER432D, ER432DD .400 (10.16)
732, 732D, 732TN, RF303, RF313,
RF323 .410 (10.41)
RF312 .350 (8.89)
“M4” Pad for TO-5
ER411, ER411D, ER411DD .295 (7.49)
ER431, ER431D, ER431DD .400 (10.16)
RF311 .300 (7.62)
RF331 .410 (10.41)
“M4” Pad for Centigrid®
172, 172D .305 (7.75)
ER114, ER114D, ER114DD,
J114, J114D, J114DD .300 (7.62)
ER134, ER134D, ER134DD,
J134, J134D, J134DD .400 (10.16)
RF100 .315 (8.00)
RF103 .420 (10.67)
“M9” Pad for Centigrid®
122C, A152 .320 (8.13)
ER116C, J116C .300 (7.62)
ER136C, J136C .400 (10.16)
RF180 .325 (8.25)
A150 .305 (7.75)
Notes:
1. Spacer pad material: Polyester  lm.
2. To specify an “M4” or “M9” spacer pad, refer to the mounting variants portion of the part numbering
example in the applicable datasheet.
3. Dimensions are in inches (mm).
4. Unless otherwise speci ed, tolerance is ± .010 (.25).
5. Add 10 m to the contact resistance show in the datasheet.
6. Add 0.01 oz. (0.25 g) to the weight of the relay assembly shown in the datasheet.
Ø.150
[3.81]
(REF)
Dim H
MAX
Dim H
MAX
Dim H
MAX
.156
[3.96]
(REF)
.256
[6.5]
(REF)
Dim H
MAX
Appendix A: Spacer Pads
© 2008 Teledyne Relays SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
Pad designation and
bottom view dimensions Height For use with the following: Dim. H
Max.
“M” Pad 5/ 6/
ER411T, J411T, ER412, ER412D
ER412DD, J412, J412D, J412DD
ER412T, J412T
.388 (9.86)
712, 712D, 712TN .393 (9.99)
ER431T, J431T, ER432, ER432D
ER432DD, J432, J432D, J432DD
ER432T, J432T
.493 (12.52)
732, 732D, 732TN .503 (12.78)
ER420, J420, ER420D, J420D
ER420DD, J420DD, ER421, J421
ER421D, J421D, ER421DD
J422D, ER422DD, J422DD, 722
.398 (10.11)
“M2” Pad 7/ 8/
ER411T
ER412, ER412D, ER412DD
J412, J412D, J412DD
.441 (11.20)
712, 712D .451 (11.46)
ER421, ER421D, ER421DD
722, 732D .451 (11.46)
ER431T
ER432, ER432D, ER432DD .546 (13.87)
732, 732D .556 (14.12)
“M3” Pad 5/ 6/ 9/
ER411, ER411D, ER411DD
ER411TX
ER412X, ER412DX, ER412DDX
ER412TX
.388 (9.86)
712X, 712DX, 712TNX .393 (9.99)
ER420X, ER420DX, ER420DDX
ER421X, ER421DX, ER421DDX
ER422X, ER422DX
ER422DDX, 722X, 722DDX
.398 (10.11)
ER431, ER431D, ER431DD
ER431TX
ER432X, ER432DX, ER432DDX
ER432TX
.493 (12.52)
732X, 732DX, 732TNX .503 (12.78)
Notes:
1. Spreader pad material: Diallyl Phthalate.
2. To specify an “M”, “M2” or “M3” spreader pad, refer to the mounting variants portion of the part number example
in the applicable datasheet.
3. Dimensions are in inches (mm).
4. Unless otherwise speci ed, tolerance is ± .010” (0.25).
5/. Add 25 m to the contact resistance shown in the datasheet.
6/. Add .01 oz. (0.25 g) to the weight of the relay assembly shown in the datasheet.
7/. Add 50 m to the contact resistance shown in the datasheet.
8/. Add 0.025 oz (0.71 g) to the weight of the relay assembly shown in the datasheet.
9/. M3 pad to be used only when the relay has a center pin (e.g. ER411M3-12A, 722XM3-26.)
.370 [9.4]
MAX SQ
.150
[3.81]
.100
[2.54]
.200
[5.08]
.300
[7.62]
.100
[2.54]
Dim H
MAX
.370
[9.4]
MIN
.014
[0.36]
(REF)
.390 [9.91]
SQ
.300
[7.62]
.100
[2.54]
.300
[7.62]
.100
[2.54] .150
[3.81]
.150
[3.81]
.130
[3.3]
Dim H
MAX
.370 [9.4]
MAX SQ
.150
[3.81]
.100
[2.54]
.200
[5.08]
.300
[7.62]
.100
[2.54]
Dim H
MAX
.370
[9.4]
MIN
.014
[0.36]
(REF)
Appendix A: Spreader Pads
(800) 284-7007 • www.teledynerelays.com +44 (0) 1236 453124 • www.teledyne-europe.com © 2008 Teledyne Relays
.100
[2.54]
.100
[2.54]
.100
[2.54]
"Y" POSITION
"Z" POSITION
.100
[2.54]
.100
[2.54]
.100
[2.54]
"W" POSITION
"U" POSITION
(ER116C and ER136C only)
"X" POSITION
"Z" POSITION
"Y" POSITION
.050
[1.27]
36°±3°
Ø.200
[Ø5.08]
"Z" POSITION
"Y" POSITION
"X" POSITION
45°±3°
"Z" POSITION
"Y" POSITION
Ø.200
[Ø5.08]
Centigrid® Relays:
RF100, RF103, ER114, ER134, 172
Centigrid® Relays:
RF180, ER116C, 122C, ER136C
TO-5 Relays:
ER411T, ER412, ER412T, ER420, ER421, ER422,
ER431T, ER432, ER432T, 712, 712TN, 400H, 400K,
400V, RF300, RF303, RF341, RF312, RF310, RF313,
RF320, RF323
TO-5 Relays:
ER411, ER431, RF311, RF331
NOTES
1. Terminal views shown
2. Dimensions are in inches (mm)
3. Tolerances: ± .010 (±.25) unless otherwise speci ed
4. Ground pin positions are within .015 (0.38) dia. of true position
5. Ground pin head dia., 0.035 (0.89) ref: height 0.010 (0.25) ref.
6. Lead dia. 0.017 (0.43) nom.
Indicates ground pin position
Indicates glass insulated lead position
Indicates ground pin or lead position
depending on relay type
Appendix A: Ground Pin Positions
© 2008 Teledyne Relays SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE