Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
PF (APF)
ASCTB205E 201202-T
ORDERING INFORMATION
Compliant with
European standards
1a/1c 6A Slim power relays
PF RELAYS (APF)
VDE
RoHS compliant
FEATURES
1. High density mounting with 5 mm
.197 inch width
Space saved with 5 mm .197 inch slim
type with 28 mm 1.102 inch length.
Allows high density mounting and use in
compact devices.
2. Satisfies reinforced insulation
standard (EN/IEC 61810-1).
3. High switching capacity
Supports 6A 250 V AC nominal switching
capacity (resistive load) and AC15 and
DC13 (inductive load).
4. 1 Form A and 1 Form C contact
arrangements with options for a
variety of applications.
5. 4,000 V high breakdown v olta ge and
6,000 V high surge breakdown v olta ge.
Controller protection against surges and
noise with a breakdown voltage of 4,000
Vrms for 1 min. between contacts and
coil, and 6,000 V surge breakdown
voltage between contacts and coil.
6. Resistance to heat and fire;
EN60335-1, clause 30 (GWT)
approved.
7. Sealed construction allows
automatic washing.
8. Complies with all safety standards.
UL/C-UL, VDE certified.
TYPICAL APPLICATIONS
1. Interface relays for programmable
controllers
2. Output relays for measuring
equipment, timers, counters and
temperature controllers
3. Industrial equipment, office
equipment
4. Household appliances for Europe
Nominal coil voltage (DC)
4H: 4.5 V 05: 5 V 06: 6 V 09: 9 V 12: 12 V 18: 18 V
24: 24 V 48: 48 V 60: 60 V
Contact arrangement
1: 1 Form A
3: 1 Form C
Contact type
0: Single contact
APF 0
Contact material
2: AgNi type
3: AgNi type/Au-plated
Note: Certified by UL/C-UL and VDE
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
PF (APF)
ASCTB205E 201202-T
TYPES
RATING
1. Coil data
Nominal coil
voltage Pick-up voltage
(at 20°C 68°F)Drop-out voltage
(at 20°C 68°F)
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)Nominal operating
power Max. applied voltage
(at 20°C 68°F)
4.5V DC
Max. 70%V
nominal voltage
(Initial)
Min. 5%V
nominal voltage
(Initial)
37.8mA 119
170mW 120%V of
nominal voltage
5V DC 34.0mA 147
6V DC 28.3mA 212
9V DC 18.9mA 476
12V DC 14.2mA 847
18V DC 9.4mA 1,906
24V DC 7.1mA 3,388
48V DC 4.5mA 10,618217mW
60V DC 2.9mA 20,570175mW
Standard packing: Tube: 20 pcs.; Case: 1,000 pcs.
Contact arrangement Nominal coil voltage Part No.
1 Form A
(AgNi type)
4.5V DC APF1024H
5V DC APF10205
6V DC APF10206
9V DC APF10209
12V DC APF10212
18V DC APF10218
24V DC APF10224
48V DC APF10248
60V DC APF10260
1 Form A
(AgNi type/Au-plated)
4.5V DC APF1034H
5V DC APF10305
6V DC APF10306
9V DC APF10309
12V DC APF10312
18V DC APF10318
24V DC APF10324
48V DC APF10348
60V DC APF10360
Contact arrangement Nominal coil voltage Part No.
1 Form C
(AgNi type)
4.5V DC APF3024H
5V DC APF30205
6V DC APF30206
9V DC APF30209
12V DC APF30212
18V DC APF30218
24V DC APF30224
48V DC APF30248
60V DC APF30260
1 Form C
(AgNi type/Au-plated)
4.5V DC APF3034H
5V DC APF30305
6V DC APF30306
9V DC APF30309
12V DC APF30312
18V DC APF30318
24V DC APF30324
48V DC APF30348
60V DC APF30360
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
PF (APF)
ASCTB205E 201202-T
2. Specifications
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of ±1.2×50µs according to JEC-212-1981
*3. The upper operation ambient temperature limit is the maximum temper ature that can satisfy the coil temperature rise value. Ref er to “Usage, tr ansport and storage
conditions” in NOTES.
*4. For cycle lifetime, refer to “Cautions for use 4)” in NOTES.
Characteristic Item Specifications
Contact Arrangement 1 Form A 1 Form C
Contact resistance (Initial) Max. 100 m (By voltage drop 6 V DC 1A)
Contact material AgNi type, AgNi type/Au-plated
Rating
Nominal switching capacity (resistive load) 6 A 250 V AC
Max. switching power (resistive load) 1,500 VA
Max. switching voltage 250V AC
Max. switching current 6 A (AC)
Nominal operating power 170 mW (5 to 24 V DC), 217 mW (48 V DC), 175 mW (60 V DC)
Min. switching capacity (Reference value)*1100 mA 5 V DC (without Au-plated), 1 mA 1 V DC (with Au-plated)
Electrical
characteristics
Insulation resistance (Initial) Min. 1,000M (at 500V DC)
Measurement at same location as “Breakdown voltage” section.
Breakdown voltage
(Initial) Between open contacts 1,000 Vr ms for 1 min. (Detection current: 10 mA)
Between contact and coil 4,000 Vr ms for 1 min. (Detection current: 10 mA)
Surge breakdown voltage*2
(Between contact and coil) (Initial) 6,000 V
Temperature rise (coil) (at 20°C 68°F)Max. 45°C 113°F
(By resistive method, nominal coil voltage applied to the coil; contact carrying current: 6A.)
Operate time (at 20°C 68°F)Max. 8 ms
(Nominal coil voltage applied to the coil, excluding contact bounce time.)
Release time (at 20°C 68°F)Max. 4 ms
(Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode)
Mechanical
characteristics
Shock resistance Functional Min. 98 m/s2
(Half-wave pulse of sine wave: 11 ms;
detection time: 10µs)
Min. 49 m/s2
(Half-wave pulse of sine wave: 11 ms;
detection time: 10µs)
Destructive Min. 980 m/s2 (Half-wave pulse of sine wave: 11 ms.)
Vibration resistance Functional 10 to 55 Hz at double amplitude of 1 mm (Detection time: 10µs.)
Destructive 10 to 55 Hz at double amplitude of 1.5 mm
Expected life
Mechanical Min. 5×106 (at 180 times/min.)
Electrical*4N.O.: Min. 5×104
(at resistive load, 6 times/min. and
nominal switching capacity)
N.O.: Min. 5×104, N.C.: Min. 3×104
(at resistive load, 6 times/min. and
nominal switching capacity)
Conditions Conditions for operation, transport and storage*3Ambient temperature: –40°C to +85°C –40°F to +185°F;
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Unit weight Approx. 5 g .18 oz
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
PF (APF)
ASCTB205E 201202-T
REFERENCE DATA
1. Electrical life
Tested sample: APF30224
Notes: 1. Switch contacts are all on N.O. side.
2. AC 15 and DC 13 comply with IEC-60947-5-1 testing conditions.
DIMENSIONS (mm inch)
Load type Voltage Current Ambient temperature No. of ops.
Resistive load 250V AC 6 A 85°C 185°F30,000
Inductive load AC 15 250V AC 3 A 25°C 77°F20,000
DC 13 24V DC 2 A 25°C 77°F 6,000
2. Max. switching capacity (AC) 3. Coil temperature rise
Tested sample: APF30224
Measured portion: Inside the coil
Ambient temperature: 28°C 82°F
4. Ambient temperature characteristics
Tested sample: APF30224, 6 pcs.
1
0.5
0.2
0.3
0.4
2
3
4
5
6
10
10 2030 50 100 250
Contact voltage, V
Contact current, A
6A
0A
50
60
70
80
90
40
30
20
10
010090 110 120 140130
Coil applied voltage, %V
Temperature rise, °C
5
10
-20
-40 -20 00
20 8560
40
-15
-10
-5
15
20 Pick-up voltage
Drop-out
voltage
Ambient
temperature,
°C
Rate of
change, %
The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/
1. 1 Form A type External dimensions
General tolerance: ±0.3 ±.012
0.4+0.2
0.1
+.008
.004
.016
1.2
.047 3.78
.149
2-0.6
2-.024
+0.2
0.1
+.008
.004
28.0max.
1.102max.
21.42
.843
2-1.0
2-.039 5.04
.198
1.9
.075
0.5
.020
15.0max.
.591max.
3.5±0.5
.138±.020 5.0max.
.197max.
1.2
.047
0.48+0.2
0.1
+.008
.004
.019
PC board pattern (Bottom view)
Tolerance: ±0.1 ±.004
Schematic (Bottom view)
3.78
.149 21.42
.843
5.04
.198 1.9
.075
1.2
.047
2-1.0 dia.
2-.039 dia.
2-1.3 dia.
2-.051 dia.
NO
COM
COIL
CAD Data
2. 1 Form C type External dimensions
General tolerance: ±0.3 ±.012
0.4+0.2
0.1
+.008
.004
.016
1.2
.047
2-0.6
2-.024
+0.2
0.1
+.008
.004 21.42
.843
3-1.0
3-.039
0.5
.020
3.5±0.5
.138±.020 5.0max.
.197max.
1.2
.047
0.48+0.2
0.1
+.008
.004
.019
3.78
.149 1.9
.075
28.0max.
1.102max.
5.04
.198
5.04
.198
15.0max.
.591max.
PC board pattern (Bottom view)
Tolerance: ±0.1 ±.004
Schematic (Bottom view)
3.78
.149 21.42
.843
5.04
.198 5.04
.198 1.9
.075
1.2
.047
2-1.0 dia.
2-.039 dia.
3-1.3 dia.
3-.051 dia.
NO
COM
NC
COIL
CAD Data
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
PF (APF)
ASCTB205E 201202-T
SAFETY STANDARDS
NOTES
For Cautions for Use.
Certification
authority File No. Applicable standard Rating Remarks
UL/C-UL E120782 UL508, CSA C22.2 No.14
UL1604 (class I, Division 2, Group A, B, C, D)
277V AC 8A, General use,
24V DC 6A, General use,
B300, R300 (Pilot Duty)
VDE 40027672 EN/IEC 61810-1
250V AC 6A (cos
φ
= 1.0) 85°C 185°F
N.O. side, N.C. side
250V AC 8A (cos
φ
= 1.0) 25°C 77°F
N.O. side
Insulation: Reinforced insulation between contact
and coil.
Resistance to heat and fire; EN60335-1, clause
30 (GWT) approved.
Usage, transport and storage
conditions
1) Temperature:
–40 to +85°C –40 to +185°F
2) Humidity: 5 to 85% RH
(Avoid freezing and condensation.)
The humidity range varies with the
temperature. Use within the range
indicated in the graph below.
3) Atmospheric pressure: 86 to 106 kPa
Temperature and humidity range for
usage, transport, and storage 4) Condensation
Condensation forms when there is a
sudden change in temperature under
high temperature and high humidity
conditions. Condensation will cause
deterioration of the relay insulation.
5) Freezing
Condensation or other moisture may
freeze on the relay when the
temperatures is low er than 0°C 32°F. This
causes problems such as sticking of
movable parts or operational time lags.
6) Low temperature, low humidity
environments
The plastic becomes brittle if the relay is
exposed to a low temperature, low
humidity environment for long periods of
time.
85
5
Humidity, %RH
Tolerance range
(Avoid
condensation
when used at
temperatures
higher than
0°C32°F)
(Avoid freezing
when used at
temperatures
lower than
0°C32°F)
850–40 +185+32–40 Temperature, °C°F