Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
PF (APF)
ASCTB205E 201202-T
2. Specifications
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of ±1.2×50µs according to JEC-212-1981
*3. The upper operation ambient temperature limit is the maximum temper ature that can satisfy the coil temperature rise value. Ref er to “Usage, tr ansport and storage
conditions” in NOTES.
*4. For cycle lifetime, refer to “Cautions for use 4)” in NOTES.
Characteristic Item Specifications
Contact Arrangement 1 Form A 1 Form C
Contact resistance (Initial) Max. 100 mΩ (By voltage drop 6 V DC 1A)
Contact material AgNi type, AgNi type/Au-plated
Rating
Nominal switching capacity (resistive load) 6 A 250 V AC
Max. switching power (resistive load) 1,500 VA
Max. switching voltage 250V AC
Max. switching current 6 A (AC)
Nominal operating power 170 mW (5 to 24 V DC), 217 mW (48 V DC), 175 mW (60 V DC)
Min. switching capacity (Reference value)*1100 mA 5 V DC (without Au-plated), 1 mA 1 V DC (with Au-plated)
Electrical
characteristics
Insulation resistance (Initial) Min. 1,000MΩ (at 500V DC)
Measurement at same location as “Breakdown voltage” section.
Breakdown voltage
(Initial) Between open contacts 1,000 Vr ms for 1 min. (Detection current: 10 mA)
Between contact and coil 4,000 Vr ms for 1 min. (Detection current: 10 mA)
Surge breakdown voltage*2
(Between contact and coil) (Initial) 6,000 V
Temperature rise (coil) (at 20°C 68°F)Max. 45°C 113°F
(By resistive method, nominal coil voltage applied to the coil; contact carrying current: 6A.)
Operate time (at 20°C 68°F)Max. 8 ms
(Nominal coil voltage applied to the coil, excluding contact bounce time.)
Release time (at 20°C 68°F)Max. 4 ms
(Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode)
Mechanical
characteristics
Shock resistance Functional Min. 98 m/s2
(Half-wave pulse of sine wave: 11 ms;
detection time: 10µs)
Min. 49 m/s2
(Half-wave pulse of sine wave: 11 ms;
detection time: 10µs)
Destructive Min. 980 m/s2 (Half-wave pulse of sine wave: 11 ms.)
Vibration resistance Functional 10 to 55 Hz at double amplitude of 1 mm (Detection time: 10µs.)
Destructive 10 to 55 Hz at double amplitude of 1.5 mm
Expected life
Mechanical Min. 5×106 (at 180 times/min.)
Electrical*4N.O.: Min. 5×104
(at resistive load, 6 times/min. and
nominal switching capacity)
N.O.: Min. 5×104, N.C.: Min. 3×104
(at resistive load, 6 times/min. and
nominal switching capacity)
Conditions Conditions for operation, transport and storage*3Ambient temperature: –40°C to +85°C –40°F to +185°F;
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Unit weight Approx. 5 g .18 oz