Industrial Ethernet Cables XS5/XS6 Cables and Connectors for EtherCAT(R) and Other Industrial Ethernet Networks CAT6a Ethernet patch cables * For in-cabinet use * LSZH with standard RJ45 plugs CAT5e Ethernet patch cables * For out-of-cabinet use * PUR with standard RJ45 plugs * PVC with rugged RJ45 plugs * PVC with M12 SmartClick plugs Connection Examples ADR ADR ADR Control panel Ideal for in-cabinet XS6W-6LSZH Ideal for out-of-cabinet XS5 XS6W-5PUR Standard Connectors Standard Connectors Rugged Connectors XS6 Rugged Assembly Connectors XS5 M12 Connectors 1 XS5/XS6 Industrial Ethernet Cables Features Cables with Standard RJ45 Connectors Refer to page 4 for details. * The lineup features LSZH cables* for in-panel wiring and PUR cables for wiring outside of panels. * The Standard RJ45 Connectors reduce cable routing space. - Outer diameter: 5.8 mm - 4-pair AWG27 (LSZH) or AWG26 (PUR) * Cable colors include blue, yellow, or green. * LSZH cables are available in 12 lengths from 0.2 to 20 m and PUR cables are available in 10 lengths from 0.5 to 20 m. * Double-shielded cables with overall braiding and individual foil shield on each wire pair to reduce EMC interference in industrial environments. * Low-smoke zero-halogen cables. Shape of RJ45 Connector LSZH Cable with Double Shield Overall braiding and individual foil shield on each wire pair Cables with Rugged RJ45 Connectors Refer to page 7 for details. * Tough latches and RJ45 connectors with strong cable holding strength are used to enable connections outside of control panels. * Quad AWG22 cable with PVC cover of 6.5 mm outer diameter. * Double-shielded cables with overall braiding and individual foil shield to reduce EMC interference in industrial environments. Shape of RJ45 Connector Tough latch PVC Cable with Double Shield Overall braiding and individual foil shield Assembly Connectors You can easily assemble Ethernet cables onsite without crimping tools or other special tools. Refer to page 14 for the assembly procedure. Cable Extension Length Standard Connectors (RJ45 Connectors) 58 mm Minimum cable bending radius: 25 mm 2 Rugged Connectors (RJ45 Connectors) 89 mm Minimum cable bending radius: 40 mm XS5/XS6 Industrial Ethernet Cables Cables with M12 Connectors * * * * Refer to page 7 for details. Resistance to harsh environments with IP67 protection. SmartClick Connectors that provide one-step (1/8th turn) connection are used (compatible with standard M12 screw connectors). A wide range of variations, such as cables with right-angle connectors and PCB connectors. Cables with sockets and robot cables were added to the series. Shape of M12 Connector PVC Cable with Double Shield Overall braiding and individual foil shield Shield structure Shield Effectiveness Data for Rugged RJ45 Connectors and Waterproof M12 Connectors The following data is the results of OMRON testing. Shield effectiveness may vary for your environment and application conditions. Comparison of Shield Effectiveness with Product without a Double Shield The following table shows the differences with a structure without a double shield. Higher numeric values show greater shield effectiveness. Shield structure Frequency (MHz) 0.5 1 5 10 30 Product with single shield 53 dB 49 dB 35 dB 25 dB 17 dB Product with a double shield (XS5@-T, Category 5E) 61 dB 58 dB 43 dB 31 dB 27 dB * SmartClick is registered trademark of OMRON Corporation. * EtherCAT(R) is a registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany. 3 XS5/XS6 Industrial Ethernet Cables Cables with Standard RJ45 Connectors Model Number Legend Use this legend when determining the product specifications from the model number. Choose from the model numbers listed in Ordering Information when ordering. X S6 W -@ @ @ @@ 8 S S @ @ @ @ C M -@ A B C D ATransmission Characteristics 5: Category 5 6: Category 6A E BSheath Material LSZH: LSZH PUR: PUR CNumber of Pins 8: 8 pins DCable Attachment Direction SS: Straight/Straight ECable Length* 20: 0.2 m 30: 0.3 m 50: 0.5 m 100: 1 m 150: 1.5 m 200: 2 m 300: 3 m 500: 5 m 750: 7.5 m 1000: 10 m 1500: 15 m 2000: 20 m FSheath Color B: Blue Y: Yellow G: Green * PUR cables are not available for 0.2-m and 0.3-m cables. 4 F XS5/XS6 Industrial Ethernet Cables Ordering Information Appearance Type Category Cable sheath material Cable color Cable length (m) Blue Cat.6a LSZH Yellow Cable with Connectors on Both Ends (RJ45/RJ45) Green Cat.5 PUR Green Model 0.2 XS6W-6LSZH8SS20CM-B 0.3 XS6W-6LSZH8SS30CM-B 0.5 XS6W-6LSZH8SS50CM-B 1 XS6W-6LSZH8SS100CM-B 1.5 XS6W-6LSZH8SS150CM-B 2 XS6W-6LSZH8SS200CM-B 3 XS6W-6LSZH8SS300CM-B 5 XS6W-6LSZH8SS500CM-B 7.5 XS6W-6LSZH8SS750CM-B 10 XS6W-6LSZH8SS1000CM-B 15 XS6W-6LSZH8SS1500CM-B 20 XS6W-6LSZH8SS2000CM-B 0.2 XS6W-6LSZH8SS20CM-Y 0.3 XS6W-6LSZH8SS30CM-Y 0.5 XS6W-6LSZH8SS50CM-Y 1 XS6W-6LSZH8SS100CM-Y 1.5 XS6W-6LSZH8SS150CM-Y 2 XS6W-6LSZH8SS200CM-Y 3 XS6W-6LSZH8SS300CM-Y 5 XS6W-6LSZH8SS500CM-Y 7.5 XS6W-6LSZH8SS750CM-Y 10 XS6W-6LSZH8SS1000CM-Y 15 XS6W-6LSZH8SS1500CM-Y 20 XS6W-6LSZH8SS2000CM-Y 0.2 XS6W-6LSZH8SS20CM-G 0.3 XS6W-6LSZH8SS30CM-G 0.5 XS6W-6LSZH8SS50CM-G 1 XS6W-6LSZH8SS100CM-G 1.5 XS6W-6LSZH8SS150CM-G 2 XS6W-6LSZH8SS200CM-G 3 XS6W-6LSZH8SS300CM-G 5 XS6W-6LSZH8SS500CM-G 7.5 XS6W-6LSZH8SS750CM-G 10 XS6W-6LSZH8SS1000CM-G 15 XS6W-6LSZH8SS1500CM-G 20 XS6W-6LSZH8SS2000CM-G 0.5 XS6W-5PUR8SS50CM-G 1 XS6W-5PUR8SS100CM-G 1.5 XS6W-5PUR8SS150CM-G 2 XS6W-5PUR8SS200CM-G 3 XS6W-5PUR8SS300CM-G 5 XS6W-5PUR8SS500CM-G 7.5 XS6W-5PUR8SS750CM-G 10 XS6W-5PUR8SS1000CM-G 15 XS6W-5PUR8SS1500CM-G 20 XS6W-5PUR8SS2000CM-G 5 XS5/XS6 Industrial Ethernet Cables Specifications Type Item Cable with Connectors on Both Ends (RJ45/RJ45)/LSZH Cable with Connectors on Both Ends (RJ45/RJ45)/PUR XS6W-6LSZH8SS@@@@CM-@ XS6W-5PUR8SS@@@@CM-G Model Rated current 1 A (at 50C) Withstand voltage 1,000 VDC for 60 s (leakage current: 1 mA max.) Ambient operating temperature -20 to 60C -40 to 85C Ambient storage tempera-20 to 60C ture -40 to 85C Ambient installation temperature 0 to 50C -10 to 60C Protective structure IP20 Materials and Finish Connectors Type Item Cable with Connectors on Both Ends (RJ45/RJ45)/LSZH Cable with Connectors on Both Ends (RJ45/RJ45)/PUR XS6W-6LSZH8SS@@@@CM-@ XS6W-5PUR8SS@@@@CM-G Model Connector housing PC resin (UL94V-0)/transparent Contacts Phosphor bronze/nickel base, gold plated (0.8 m) Shield Brass/nickel plated Cover (structured to prevent the tab from breaking) LSZH: Blue, yellow, or green Marking tube PVC resin (UL94V-0)/transparent PUR: Green Cables Type Item Cable with Connectors on Both Ends (RJ45/RJ45)/LSZH Cable with Connectors on Both Ends (RJ45/RJ45)/PUR XS6W-6LSZH8SS@@@@CM-@ XS6W-5PUR8SS@@@@CM-G Model Compliant standard IEC 60332-1 /UL1581 FT2 IEC 60332-1 /UL1581 FT2 Number of cores/gauge 4 x 2 x AWG27 0.1 mm2 4 x 2 x AWG26 0.13 mm2 Outer diameter*1 5.8 mm Sheath color*2 Blue, yellow, or green Sheath material LSZH PUR Shield structure Double shield S/FTP Double shield SF/UTP *2. Sheath. Green *1. Outer diameter. Dimensions (Unit: mm) Cable with Connectors on Both Ends (RJ45/RJ45) XS6W-6LSZH8SS@@@@CM-@ XS6W-5PUR8SS@@@@CM-G Wiring RJ45 1 2 3 4 5 6 7 8 Shield RJ45 1 2 3 4 5 6 7 8 Shield L (cable length) (14) 13.2 38.5 18 38.5 18 Marking tube Note. External dimensions are the same for all cable materials. 6 XS5/XS6 Industrial Ethernet Cables Cables with Rugged RJ45 Connectors and Cables with M12 Connectors Model Number Legend Use this legend when determining the product specifications from the model number. Choose from the model numbers listed in Ordering Information when ordering. Cable with Connectors RJ45 Assembly Connectors XS 5@ -T 4 2 @- @ M@ - @ @ A BCD E F G XS6G-T 4 2 1-1 H ABCD E AConnector Shape H: Cable with plug on one end W: Cable with connectors on both ends AType T: Ethernet BType T: Ethernet (mating part: M12 D coding) 4: 4 pins CNumber of Pins 4: 4 pins 2: Gold plating, 0.4 m DContact Plating Specification 2: Gold plating, 0.4 m 1: Straight ECable Attachment Direction (M12 Connectors) 1: Straight 2: Right angle FCable Length A: 0.3 m B: 0.5 m C: 1 m D: 2 m E: 3 m G: 5 m J: 10 m K: 15 m GConnector Shape 0: M12 plug on one end 1: Connectors on both ends: M12 socket/M12 plug 2: Connectors on both ends: M12 plug/M12 plug C: Connectors on both ends: M12 plug/RJ45 plug D: Connectors on both ends: RJ45 plug/RJ45 plug E: Connectors on both ends: M12 socket/RJ45 plug HCable Specification K: Standard cable KR: Robot cable BNumber of Pins CContact Plating Specification DCable Attachment Direction EDegree of Protection 1: IP20 M12 Connectors for Panel Mounting X S 5 P - T 4 2 @ -@ ABCD E AType T: Ethernet (mating part: M12 D coding) BNumber of Pins 4: 4 pins CPlating Specification 2: Gold plating, 0.4 m DMounting Method 6: Rear lockingt 7: Front locking ETerminal Shape 1: DIP terminalst 5: Cable with loose wires (0.5 m) 7 XS5/XS6 Industrial Ethernet Cables Ordering Information Appearance Cable type Type Cable with Plug on One End (M12 Straight) Cable with Plugs on Both Ends (M12 Straight/M12 Straight) Cable with Plugs on Both Ends (M12 Straight/RJ45) Cable with Plug on One End (M12 Right-angle) Standard Cables Cable with Plugs on Both Ends (M12 Right-angle/M12 Right-angle) Cable with Plugs on Both Ends (M12 Right-angle/RJ45) Cable with Plugs on Both Ends (RJ45/RJ45) Cable with Plug on One End and Socket on Other End (M12 Straight/M12 Straight) Cable with Plug on One End and Socket on Other End (M12 Straight/RJ45) 8 Cable length (m) 0.5 1 2 3 5 10 Model XS5H-T421-BM0-K XS5H-T421-CM0-K XS5H-T421-DM0-K XS5H-T421-EM0-K XS5H-T421-GM0-K XS5H-T421-JM0-K 15 XS5H-T421-KM0-K 0.5 1 2 3 5 10 XS5W-T421-BM2-K XS5W-T421-CM2-K XS5W-T421-DM2-K XS5W-T421-EM2-K XS5W-T421-GM2-K XS5W-T421-JM2-K 15 XS5W-T421-KM2-K 0.3 0.5 1 2 3 5 10 15 0.5 1 2 3 5 10 XS5W-T421-AMC-K XS5W-T421-BMC-K XS5W-T421-CMC-K XS5W-T421-DMC-K XS5W-T421-EMC-K XS5W-T421-GMC-K XS5W-T421-JMC-K XS5W-T421-KMC-K XS5H-T422-BM0-K XS5H-T422-CM0-K XS5H-T422-DM0-K XS5H-T422-EM0-K XS5H-T422-GM0-K XS5H-T422-JM0-K 15 XS5H-T422-KM0-K 0.5 1 2 3 5 10 XS5W-T422-BM2-K XS5W-T422-CM2-K XS5W-T422-DM2-K XS5W-T422-EM2-K XS5W-T422-GM2-K XS5W-T422-JM2-K 15 XS5W-T422-KM2-K 0.3 0.5 1 2 3 5 10 15 0.3 0.5 1 2 3 5 10 15 0.5 1 2 3 5 10 15 0.5 1 2 3 5 10 15 XS5W-T422-AMC-K XS5W-T422-BMC-K XS5W-T422-CMC-K XS5W-T422-DMC-K XS5W-T422-EMC-K XS5W-T422-GMC-K XS5W-T422-JMC-K XS5W-T422-KMC-K XS5W-T421-AMD-K XS5W-T421-BMD-K XS5W-T421-CMD-K XS5W-T421-DMD-K XS5W-T421-EMD-K XS5W-T421-GMD-K XS5W-T421-JMD-K XS5W-T421-KMD-K XS5W-T421-BM1-K XS5W-T421-CM1-K XS5W-T421-DM1-K XS5W-T421-EM1-K XS5W-T421-GM1-K XS5W-T421-JM1-K XS5W-T421-KM1-K XS5W-T421-BME-K XS5W-T421-CME-K XS5W-T421-DME-K XS5W-T421-EME-K XS5W-T421-GME-K XS5W-T421-JME-K XS5W-T421-KME-K XS5/XS6 Industrial Ethernet Cables Appearance Cable type Type Cable length (m) 0.5 1 2 3 5 10 15 0.5 1 2 3 5 10 15 0.5 1 2 3 5 10 15 0.5 1 2 3 5 10 15 Model XS5W-T421-BM1-KR XS5W-T421-CM1-KR XS5W-T421-DM1-KR XS5W-T421-EM1-KR XS5W-T421-GM1-KR XS5W-T421-JM1-KR XS5W-T421-KM1-KR XS5W-T421-BM2-KR XS5W-T421-CM2-KR XS5W-T421-DM2-KR XS5W-T421-EM2-KR XS5W-T421-GM2-KR XS5W-T421-JM2-KR XS5W-T421-KM2-KR XS5W-T421-BMC-KR XS5W-T421-CMC-KR XS5W-T421-DMC-KR XS5W-T421-EMC-KR XS5W-T421-GMC-KR XS5W-T421-JMC-KR XS5W-T421-KMC-KR XS5W-T421-BMD-KR XS5W-T421-CMD-KR XS5W-T421-DMD-KR XS5W-T421-EMD-KR XS5W-T421-GMD-KR XS5W-T421-JMD-KR XS5W-T421-KMD-KR --- XS6G-T421-1 Rear locking 0.5 XS5P-T426-5 Front locking 0.5 XS5P-T427-5 --- XS5P-T426-1 Cable with Plug on One End and Socket on Other End (M12 Straight/M12 Straight) Cable with Plugs on Both Ends (M12 Straight/M12 Straight) Robot Cables Cable with Plugs on Both Ends (M12 Straight/RJ45) Cable with Plugs on Both Ends (RJ45/RJ45) RJ45 Assembly Connector Standard Cables M12 Connector for Panel Mounting M12 Panel-mounting PCB Straight Terminals Cable Bending Data for Robot Cables (XS5W-T421-@M@-KR) The following data is the results of OMRON testing for cable bending test conditions. The number of bends may vary for your environment and application conditions. Cableveyor Test 90 Bending Test Number of bends: 20 million min. Number of bends: 6 million min. Travel distance Cable secured to end Cableveyor Cable secured to end Roller Travel speed: Approx. 120 m/min Travel distance: 1 m Cableveyor radius: 75 mm Cable Bending angle: 90 Speed: Approx. 30 bends/min Roller radius: 60 mm Weight: 500 g Weight 9 XS5/XS6 Industrial Ethernet Cables Specifications Cable with Type Plug on One End (M12) Item Model XS5H -T42@-@M0-K Cable with Plugs on Both Ends (M12/M12) Cable with Plug on One End and Socket on Other End (M12/M12) Cable with Plugs on Both Ends (M12/RJ45) XS5W -T42@-@M2-K, -KR XS5W -T42@-@M1-K, -KR XS5W -T42@-@MC-K, -KR Rated current 3A Rated voltage 30 V Contact resistance 40 m max. Insulation resistance 1,000 M min. Withstand voltage 1,000 VAC for 60 s (leakage current: 1 mA max.) Ambient operating temperature -25 to 70C Ambient storage temperature -25 to 70C Protective structure M12: IEC IP67, RJ45: IEC IP20 Cable with Plug on One End and Socket on Other End (M12/RJ45) XS5W -T421-@ME-K Cable with M12 ConnecPlugs on Both RJ45 Assembly tor for Panel Ends Connector Mounting (RJ45/RJ45) XS5W -T421-@MD-K, -KR XS6G -T421-1 2.5 A M12 Panelmounting PCB Straight Terminals XS5P-T42@-5 XS5P -T426-1 4A 125 VDC 500 M min. 1,000 M min. 1,500 VAC for 60 s (leakage current: 1 mA max.) Materials and Finish Connectors Model M12 Item XS5H and XS5W Contact blocks Contacts RJ45 XS5P-T42@-5 XS5P-T426-1 XS5W and XS6G PBT resin (UL94V-0)/light gray PA resin (UL94V-0)/black PA resin (UL94V-0)/black Phosphor bronze/nickel base, gold plated (0.4 m) Brass/nickel base, gold plated (0.4 m) Phosphor bronze/nickel base, gold plated (1.4 m) Anchors Zinc diecast/nickel plating Anchors (tabs) SUS --- Cover Straight connector: Soft PBT resin (UL94V-0)/black Right-angle connector: TPC resin/black --- Sealing resin --- Epoxy resin O-rings Rubber Grounding fixture --- Anchor cover --- Nuts --- --- ----Phosphor bronze/nickel base, tin plated (2.0 m) SUS Brass/nickel plated ------- Cables Model Standard Cables Item Compliant standard Robot Cables UL CM Category Category 5e Number of cores/gauge 4 x AWG22 0.3 mm2 (7/0.26) Outer diameter*1 6.5 dia. Sheath color*2 Light blue Sheath material PVC Shield structure Double shield SF/UTP 4 x AWG22 0.3 mm2 (7/24/0.05) Note. For the XS5H and XS5W, cables are available only with connectors attached. 10 *2. Sheath. *1. Outer diameter. XS5/XS6 Industrial Ethernet Cables Dimensions (Unit: mm) Cable with Plug on One End (M12 Straight) XS5H-T421-@M0-K Wiring Terminal No. Color 1 Yellow 2 White 3 Orange 4 Blue L (cable length) 44.7 2 1 2 1 3 14.9 dia. 4 3 4 M12 x 1 (Plug) Cable with Plugs on Both End (M12 Straight/M12 Straight) XS5W-T421-@M2-K XS5W-T421-@M2-KR Wiring M12 straight 1 2 3 4 Shield M12 straight 1 2 3 4 Shield L (cable length) 44.7 44.7 1 4 3 4 3 14.9 dia. 14.9 dia. 1 1 2 2 3 2 4 3 4 1 M12 x 1 (Plug) M12 x 1 Cable with Plugs on Both Ends (M12 Straight/RJ45) XS5W-T421-@MC-K XS5W-T421-@MC-KR 2 (Plug) Wiring M12 straight 1 2 3 4 Shield RJ45 1 3 2 6 Shield L (cable length) 44.7 2 54.7 1 2 1 3 14.9 dia. 4 3 4 M12 x 1 (Plug) RJ45 Cable with Plug on One End and Socket on Other End (M12 Straight/M12 Straight) XS5W-T421-@M1-K XS5W-T421-@M1-KR Wiring M12 straight 1 2 3 4 Shield M12 straight 1 2 3 4 Shield L (cable length) 44.7 2 50.7 1 3 4 4 3 14.9 dia. 3 14.9 dia. 2 1 1 2 4 3 4 2 M12 x 1 (Plug) M12x1 Cable with Plug on One End and Socket on Other End (M12 Straight/RJ45) XS5W-T421-@ME-K 1 (Socket) Wiring M12 straight 1 2 3 4 Shield RJ45 1 3 2 6 Shield L (cable length) 50.7 1 14.9 dia. 2 1 4 4 54.7 2 3 3 (Socket) M12 x 1 RJ45 11 XS5/XS6 Industrial Ethernet Cables Cable with Plug One End (M12 Right-angle) XS5H-T422-@M0-K Wiring Terminal No. Color 1 Yellow L (cable length) 2 White 3 Orange 4 Blue 22.5 32.3 14.9 dia. M12 x 1 4 3 2 4 1 1 3 2 (Plug) Cable with Plugs on Both Ends (M12 Right-angle/M12 Right-angle) XS5W-T422-@M2-K Wiring M12 right angle 1 2 3 4 Shield L (cable length) 22.5 22.5 32.3 M12 right angle 1 2 3 4 Shield 32.3 14.9 dia. 1 M12 x 1 M12 x 1 3 3 4 14.9 dia. 2 1 3 4 2 1 3 2 4 4 2 1 (Plug) (Plug) Cable with Plugs on Both Ends (M12 Right-angle/RJ45) XS5W-T422-@MC-K L (cable length) 54.7 22.5 32.3 RJ45 14.9 dia. M12 x 1 Wiring 4 M12 right angle 1 2 3 4 Shield 4 3 2 1 1 3 2 (Plug) Cable with Plugs on Both Ends (RJ45/RJ45) XS5W-T421-@MD-K XS5W-T421-@MD-KR Wiring RJ45 1 2 3 6 Shield L (cable length) 54.7 54.7 RJ45 12 RJ45 1 3 2 6 Shield RJ45 RJ45 1 2 3 6 Shield XS5/XS6 Industrial Ethernet Cables RJ45 Assembly Connector XS6G-T421-1 52.6 11.8 11.3 8.1 Contact 6 Contact 1 Contact 2 Contact 3 Applicable wires Sheath outer diameter: 6.1 to 6.9 mm Core size: AWG22 to AWG24 (stranded wires) AWG22 to AWG23 (solid wires) Insulation outer diameter: 1.6 mm max. M12 Connector for Panel Mounting XS5P-T42@-5 XS5P-T426-5 (Rear Locking) M12 x 1 PG9 2.8 17 18 Wiring Color 1 Yellow 18 Orange 500 White 14.6 dia. 2 White 3 Orange 4 Blue 20 103 2.5 (Socket) Terminal No. (20) Yellow Blue Panel Cutout Dimension 11.9 22.1 15.3 +0.1 0 dia. XS5P-T427-5 (Front Locking) M12 x 1 Panel thickness t = 1 to 4 2.8 18 17 PG9 20 500 Orange White 103 (Socket) 10.5 22.1 (20) Blue Yellow 2.5 M12 Panel-mounting PCB Straight Terminals XS5P-T426-1 Mounting Hole Dimensions (D Cut Structure) 14 M12x1 B 2.5 5.3 +0.1 0 15 A (Socket) Mounting Hole Dimensions 10.6 +0.2 0 19.9 10.4 Pin No. Note 1: The panel cutout dimension is the same for Front-locking and Rearlocking Connectors. Note 2: Rotational positioning is not possible for connector rotation. 18 13.9 dia. C A C B 2.5 0.5 min. 1.20.04 dia. x 45 1.20.04 dia. x 45 2 to 3 2 to 3 16.5 dia. 14.6 dia. 3 12.20.05 dia. 12.20.05 dia. Cross-section Diagram A-A Cross-section Diagram C-C 0.5 min. Cross-section Diagram B-B Panel Processing Dimensions 50.05 dia. 451 50.05 Four, 1.2 +0.1 0 dia. Three, 1.4 +0.1 0 dia. 1 +0.1 0 dia. 7.050.05 4.50.05 8.50.05 13 XS5/XS6 Industrial Ethernet Cables Assembly Procedure RJ45 Assembly Connectors XS6G-T421-1 1. 2. M12 Panel-mounting PCB Straight Terminals XS5P-T426-1 Confirming the Number of Parts Pass the cable through the cable clamp and the connector housing Strip the cable sheath and ground braiding to the correct lengths. 3. Follow the color codes and prepare to insert the wires into the splice piece. 4. Insert the wires into the splice piece for the length of the splice piece. 5. 6. 7. The following four parts are included in the package when it is delivered. 24 mm 13 mm Panel-mounting Parts 1. Anchor 2. O-Ring 3. Nut PCB-mounting Part 4. Connector Assembly Procedure 1. Mount the connector to the PCB. 2. Attach the anchor to the panel with the nut. Place the splice piece into the RJ45 data module and engage it. Mounting the Connector to the PCB Place the data module and the splice piece on the IDC assembly housing. Mounting the Anchor to the Panel Anchor PCB *Tightening torque: 1 N*m Press the data module and the IDC assembly housing together and use pliers or a similar device to make the insulation displacement contact. 8. Remove the data module from the IDC assembly housing. 9. Place the upper screen plate on the data module and press it over the ground braiding of the cable. Panel Nut 3. Attach the connector that you mounted to the PCB to the panel. * Make sure that the connector and anchor are oriented correctly. Attachment 5 mm 10. Place the lower screen plate on the bottom of the data module, align it with the upper screen place, and latch it until you hear it click into place. Align the flat surface on the anchor with the grounding fixture terminal. 4. Temporarily mount the O-ring to the top of the connector at the mating surface. Temporary Mounting of the O-Ring 11. Slide the housing that you placed around the cable in step 1 up to the data module and latch it until you hear it click into place. O-ring 12. Tighten the cable clamp. Pin Assignments Pin Assignments for Fast Ethernet 10/100 Mbps Wire color Function/Signal Transmission Data+/TD+ Industrial Ethernet EIA/TIA 568A EIA/TIA 568B Pin No. YE WH/GN WH/OG 1 5. Mate the Connector Waterproof Cover (XS2Z-22, sold separately) or the Partner Connector Plug (XS5H-T42@-@M0-K, sold separately) and press the O-ring to the O-ring position after mounting. Mounting the O-Ring Transmission Data-/TD- OG GN OG 2 Receiver Data/RD+ WH WH/OG WH 3 Receiver Data/RD- BU OG GN 6 O-Ring Position after Mounting Connector Waterproof Cover (Sold Separately) XS2Z-22 * Tightening torque: 0.39 to 0.49 N*m 14 XS5/XS6 Industrial Ethernet Cables Safety Precautions Precautions for Correct Use Do not use the Connectors in an atmosphere or environment that exceeds the specifications. Connector Connection and Disconnection * When connecting or disconnecting Connectors, be sure to hold the Connectors. * Do not hold the cable when disconnecting Connectors. * When joining Connectors, be sure to insert the plug all the way to the back of the socket before attempting to lock the Connectors. * Do not use tools of any sort to join the Connectors. Always use your hands. Pliers or other tools may damage the Connectors. Handling Precautions * Do not pull on the Connectors or cables with excessive force. Do not install the Connectors with a load placed directly on the joint or at the point where the wires connect to the Connector. The Connector may be damaged or the wires in the cable may be disconnected. * Lay the cable where it will not be stepped on to prevent the wires in the cable from being disconnected and to protect the Connectors from being damaged. If the cable must be placed where it will be stepped on, install a protective cover. * When bending cables, do not exceed the cable specifications. Wiring Lay the cables so that external force is not applied to the Connectors. Otherwise, the degree of protection (IP67) may not be achieved. Degree of Protection for M12/Smartclick Connectors * The degree of protection of Connectors (IP67) is not for a fully watertight structure. Do not use the Connectors underwater. * Do not step on or place any objects on the Connectors. Doing so may damage the Connectors. 15 OMRON Corporation Industrial Automation Company Authorized Distributor: Tokyo, JAPAN Contact: www.ia.omron.com Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69-2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388 OMRON ELECTRONIC COMPONENTS LLC 55 Commerce Drive, Suite B, Shaumburg, IL, 60173, U.S.A. Tel: (1) 847-882-2288/Fax: (1) 847-882-2192 OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 (c) OMRON Corporation 2010 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. Printed in Japan CSM_8_1_0314 0314 (0710) Cat. No. G019-E1-06