The ABC350 Series of open frame power supplies feature a wide universal AC input range of 90 - 264 VAC, offering 350 W of output power in a compact 3 x 5 x 1 inch footprint, with a variety of isolated single output voltages. The high efficiency and high power density of the ABC family ensures minimal power loss in end-use equipment, thereby facilitating higher reliability, easier thermal management and meets regulatory approvals for environmentally-friendly end products. These power supplies are ideal for telecom, datacom, industrial equipment and other applications. * 3 x 5 x 1 Inch Form Factor * 350 W with Forced Air Cooling & 200 W with Convection Cooling * Efficiencies up to 94% * -40 to 70C Operating Temperature * 12 V / 0.5 A Fan Output, Thermal Shut-Down Feature * 2.56 Million Hours, Telcordia -SR332-Issue 3 MTBF * Standby Power < 0.5 W * Approved to EN60950-1 * RoHS Compliant Instrumentation Renewable Energy Lighting Test and Measurement Industrial Applications Automation Control Applied Computing Wireless Communication ABC350 Series 2 MODEL NUMBER DESCRIPTION VOLTAGE MAX. LOAD (CONVECTION) MAX. LOAD (375 LFM) MIN. LOAD RIPPLE & NOISE1 Thermal shutdown feature: The power supply goes in hiccup mode when the temperature of PCB exceeds 110 C (+/-10 C). Specifications are for nominal input voltage, 25C unless otherwise stated. PARAMETER DESCRIPTION / CONDITION SPECIFICATION Input Voltage Universal (Derate from 100% at 100 VAC to 90% at 90 VAC) 90-264 VAC / 390 VDC Input Frequency 47 - 63 Hz Input Current 115 VAC: 230 VAC: 3.6 A max. 1.8 A max. No Load Power Typical >0.5 W Inrush Current 115 VAC: 230 VAC: 264 VAC: 25 A 45 A 75 A Leakage Current Typical 300 A Power Factor Full Load >0.95 Switching Frequency PFC: PWM: 70 - 130 KHz 50 - 80 KHz 1 Ripple is peak to peak with 20 MHz bandwidth and 10 F (Tantalum capacitor) in parallel with a 0.1 F capacitor at rated line voltage and load ranges. 2 When used in Cover Kit, de-rate output power to 70 % under all operating conditions tech.support@psbel.com ABC350 Series 3 PARAMETER DESCRIPTION / CONDITION SPECIFICATION Output Power3 With 375 LFM: Convection: 48 V, 58 V: 24 V, 30 V: 12 V, 15 V: Full Load: Convection Load: 350 W 200 W 94% 93% 92% 8 ms typical 14 ms typical Efficiency Hold-up Time Line Regulation +/-0.5% Load Regulation +/-1% Transient Response 50-100% step load change, at 0.1A/S slew rate, 50% duty cycle, 50 Hz = 5% , Voltage Adjustment +/-3% Rise Time Typical Set Point Tolerance recovery time < 5 ms 55 ms 4 +/-1% Over Current Protection Hiccup mode / Auto Recovery >110% Over Voltage Protection Hiccup mode / Auto Recovery 110 to 140% Short Circuit Protection Hiccup mode / Auto Recovery Conducted Emissions EN55032-B, CISPR22-B, FCC PART15-B Pass Radiated Emissions EN 55032 A; with external core (King core K5B RC 25x12x15-M in input cable) Pass Level B Input Current Harmonics EN 61000-3-2 Class D Voltage Fluctuation and Flicker EN 61000-3-3 Pass ESD Immunity EN 61000-4-2 Level 3, Criterion A Radiated Field Immunity EN 61000-4-3 Level 3, Criterion A Electrical Fast Transient Immunity EN 61000-4-4 Level 3, Criterion A Surge Immunity EN 61000-4-5 Level 3, Criterion A Conducted Immunity EN 61000-4-6 Level 3, Criterion A Magnetic Field Immunity EN 61000-4-8 Level 3, Criterion A Voltage Dips, Interruptions EN 61000-4-11 Criterion A & B PARAMETER Agency Approvals DESCRIPTION / CONDITION Input to Output: for ITE application Input to GND: Approved to the latest edition of the following standards: CSA/UL60950-1, EN60950-1 and IEC60950-1, Class1 SELV Nemko, UL, C-UL CE mark Complies with LVD Directive Isolation Voltage Safety Standards 3 4 SPECIFICATION 3000 VAC 1500 VAC Combined output power of main output, fan supply shall not exceed max. power rating. Fan supply output voltage tolerance including set point accuracy, line & load regulation is +/-10% and ripple & noise is less than 10%. Europe, Middle East +353 61 225 977 North America +1 408 785 5200 (c) 2017 Bel Power Solutions & Protection BCD.00560_AF Asia-Pacific +86 755 298 85888 ABC350 Series 4 PARAMETER Operating Temperature5 DESCRIPTION / CONDITION SPECIFICATION Startup guaranteed, with spec deviation, see Fig. 1 -40 to +70C -40 to 0C Storage Temperature -40 to 85 C With 375 LFM forced air cooling at 100 to 264 VAC: With natural convection cooling at 100 to 264 VAC: Operating: Non-operating: 350 W 200 W 16,000 ft. 40,000 ft. Humidity Non Condensing 5% to 95% Reliability MTBF according to Telcordia - SR332-Issue 3 2.56 million hours Cooling Altitude CONNECTOR AC Input Connector DC Output Connector PIN DESCRIPTION / CONDITION MANUFACTURER / PN J1 Pin 1 Pin 2 Pin 3 AC Line Not Fitted AC Neutral Molex: 26-60-4030 Mating: 09-50-3031; Pins: 08-50-0106 Pin 1 Pin 2 V1 +VE V1 - VE Pin 1,2,3,4 Pin 5,6,7,8 Pin 1 Pin 2 V1 +VE V1 - VE FAN +VE FAN -VE J2 Screw Terminal (Option 1) Molex Connector (Option 2) Aux (Fan) Output J3 Earth J4 Weight 300 g Dimensions 76.2 x 127.0 x 25.4 mm (3 x 5 x 1 inch) 5 6-32 inches Screw Pan HD Mating: 16 AWG wire crimped to Ring Tongue Terminal AMP: 8-31886-1 Molex: 26-60-4080 Mating: 09-50-3081; Pins: 08-50-0106 AMP :640456-2 Mating: 640440-2 Molex: 19705-4301 Mating: 19003-0001 Output ripple can be more than 10% of the output voltage. tech.support@psbel.com ABC350 Series 5 Figure 2. Mechanical Drawing - Screw Terminal (Option 1) Figure 3. Mechanical Drawing - Molex Header (Option 2) NOTES: In case the PCB is mounted in a metal enclosure, using metal hardware ensure the following: 1 Stand off, used to mount PCB has OD of 5.4 mm max. 2 Screws, used to fix PCB on stand off, have head dia of 6.0 mm max. 3 Washer, if used, to have dia of 6.5 mm max. Europe, Middle East +353 61 225 977 North America +1 408 785 5200 (c) 2017 Bel Power Solutions & Protection BCD.00560_AF Asia-Pacific +86 755 298 85888 6 ABC350 Series Convection load: 180 W up to 50 C De-rate above 50 C @ 2.5% per C Forced air cooled load: 300 W up to 50C De-rate above 50 C @ 2.5% per C Convection load: 180 W up to 50 C De-rate above 50 C @ 2.5% per C Forced air cooled load: 325 W up to 50C De-rate above 50 C @ 2.5% per C Convection load: 200 W up to 50 C De-rate above 50 C @ 2.5% per C Forced air cooled load: 350 W up to 50C De-rate above 50 C @ 2.5% per C NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. tech.support@psbel.com