9 SYSMAC Remote Master Modules C200H-RM 01 Wired and Fiber-optic Remote I/O Systems Match Your Distance Needs 1 Wired remote I/O systems offer up to 200 m maximum distance using shielded twisted pair wire, Belden #9271 or equivalent 1 Fiber-optic remote I/O systems prevent electrical noise from fouling longdistance communication signals 1 Transmission distance with fiber-optic cables depends on core material: 20 m for all plastic; 200 m for plastic clad 1 Master modules connect to slave racks or remote I/O relay or transistor blocks Ordering Information 3 WIRED REMOTE I/O SYSTEM Classification Description Specification Part number Remote master For CS1, C200H, C200H Alpha systems Use up to 2 masters per CPU C200H-RM201 Transmission line Shielded twisted pair cable Belden #9271 or equivalent Commercially available 3 FIBER-OPTIC REMOTE I/O SYSTEM Classification Description Specification Part number Remote master For CS1, C200H, C200H Alpha systems Use up to 2 masters per CPU C200H-RM001-PV1 Transmission media APF (all plastic) fiber-optic cable (user must assemble connectors) 20 m (65 ft), without connectors B500-PF212 Connectors, brown (includes 2) For cables 0 to 10 m length 3G5A2-CO001 Connectors, black (includes 2) For cables 8 to 20 m length 3G5A2-CO002 HPCF ((plastic clad)) fiber-optic cable,, i d / td indoor/outdoor use (user must assemble connectors) 50 m (164 ft) FCS-HCR-LB-501 100 m (328 ft) FCS-HCR-LB-102 500 m (1640 ft) FCS-HCR-LB-502 1 km (3280 ft) FCS-HCR-LB-103 Zipcord style, orange, without connectors 50 m (164 ft) FCS-HCR-CO-501 Connectors for SYSMAC BUS Order two, one for each end S3200-COCH82 Termination kit for HPCF cable ------ FCS-CAK6230-US 3 REMOTE SLAVE RACKS For part numbers and configuration information, refer to the CS1 or C200H Alpha Programmable Controller Catalogs, or C-Series Wired Remote I/O Manual (W120) or C-Series Fiber-optic Remote IO Manual (W136). C200H-RM 01 C200H-RM 01 Specifications 3 COMMUNICATIONS SPECIFICATIONS Communications method Half-duplex Coding method Manchester coding method Connection method RS-485 Communications baud rate 187.5 kbps Communications cable C200H-RM201: 2-conductor cable: Belden #9271 or VCTF (JIS L3306) C200H-RM001: Fiber-optic cable: all plastic or hard plastic clad fiber media Communications di t distance Wired Belden #9271 or VCTF cable: 200 m (656 ft) Fiber-optic All plastic fiber (APF): 20 m (65.6 ft) Hard plastic fiber (HPCF): 200 m (656 ft) Max. number of connecting nodes 32 (512 words max.) Error control checks Manchester code check, frame length check, and parity check 3 MODULE SPECIFICATIONS Current consumption C200H-RM201 wired master: 0.25 A C200H-RM001 fiber-optic master: 0.2 A Number of I/O points 512 max. Number of occupied words 512 max. Omron PLC model CS1, C200HX (-ZE), C200HG (-ZE), C200HE (-ZE), C200HS Max. number of Slaves per Master 32 Approved standards UL 508 (E95399), CSA C22.2 No. 142 (LR51460) Note: For detailed specifications on wired or fiber-optic SYSMAC BUS systems, refer to the following manuals: W120 C-Series Wired Remote I/O W136 C-Series Fiber-optic Remote I/O Dimensions Unit: mm (inch) C200H-RM001-PV1 C200H-RM201 RM201 130 (5.12) 35 (1.38) 100 (3.94) Note: Refer to the C200HX, C200HG, C200HE, C200HS, or CS1 Operation Manual for details on the dimensions when the Master Module is installed in the PLC Backplane. 2 C200H-RM 01 C200H-RM 01 NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4. 9 OMRON ELECTRONICS, INC. OMRON CANADA, INC. One East Commerce Drive Schaumburg, IL 60173 885 Milner Avenue Scarborough, Ontario M1B 5V8 1-800-55-OMRON 416-286-6465 Cat. No. GC RIO-1 04/00 Specifications subject to change without notice. Printed in U.S.A. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: 3G5A2-CO001 FCS-HCR-CO-501 FCS-HCR-LB-103