MOS FET Relays G3VM-601G 227
MOS FET Relays
G3VM-601G
Ultrasensitive MOS FET Relays in 600 V Load
series for electric power saving.
4-pin SOP package now included in the 600 V load series.
Trigger LED forward current of 1 mA (maximum)
facilitates power saving designs and prolonged battery life.
Continuous load current of 90 mA.
RoHS Compliant
Application Examples
Broadband systems and Measurement devices
Security systems and Industrial equipment
Battery powered equipment and Amusement machines
Note: The actual product is marked differently from the image shown
here.
List of Models
Note: The AC peak and DC value are given for the load voltage.
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Terminal Arrangement/Internal Connections (Top View)
Actual Mounting Pad Dimensions (Recommended Value, Top View)
Contact form Terminals Load voltage (peak value)
(See the note.) Model Number per stick Number per tape
SPST-NO Surface-mounting ter-
minals
600 V G3VM-601G 100 ---
G3VM-601G(TR) --- 2,500
4.4±
0.25
3.9±
0.25
0.4±
0.1
2.54±
0.25
2.1 max.
0.1±
0.1
7.0±
0.4
0.6±
0.3
0.15
G3VM-601G
Note: The actual product is marked differently
from the image shown here. Weight: 0.1 g
OMRON logo Model name
LOT No.
Pin 1 mark
Mold pin mark
43
12
43
12
G3VM-601G
Note: The actual product is marked differently
from the image shown here.
6 to 6.3
1.2
0.8
2.54
G3VM-601G
228 MOS FET Relays G3VM-601G
Absolute Maximum Ratings (Ta = 25°C)
Electrical Characteristics (Ta = 25°C)
Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item Symbol Rating Unit Measurement Conditions
Input LED forward current IF50 mA
Repetitive peak LED
forward current
IFP 1 A 100 μs pulses, 100 pps
LED forward current
reduction rate
Δ IF/°C0.5 mA/°CT
a 25°C
LED reverse voltage VR5V
Connection temperature Tj125 °C
Output Load voltage (AC peak/DC) VOFF 600 V
Continuous load current
(AC peak/DC)
IO90 mA
ON current reduction rate Δ IO/°C0.9 mA/°CT
a 25°C
Dielectric strength between input and
output (See note 1.)
VI-O 1,500 Vrms AC for 1 min
Operating temperature Ta40 to +85 °C With no icing or condensation
Storage temperature Tstg 55 to +125 °C With no icing or condensation
Soldering temperature (10 s) --- 260 °C 10 s
Note: 1. The dielectric strength between the input
and output was checked by applying voltage
between all pins as a group on the LED side
and all pins as a group on the light-receiving
side.
Item Symbol Mini-
mum Typical Maxi-
mum Unit Measurement
conditions
Input LED forward voltage VF1.0 1.15 1.3 V IF = 10 mA
Reverse current IR--- --- 10 μAV
R = 5 V
Capacity between terminals CT--- 30 --- pF V = 0, f = 1 MHz
Trigger LED forward current IFT --- 0.4 1 mA IO = 90 mA
Output Maximum resistance with output ON RON --- 45 60 ΩIF = 2 mA,
IO = 90 mA
Current leakage when the relay is open ILEAK --- 0.001 1.0 μAV
OFF = 600 V
Capacity between terminals COFF --- 75 --- pF V = 0, f = 1MHz
Capacity between I/O terminals CI-O --- 0.8 --- pF f = 1 MHz, Vs = 0 V
Insulation resistance RI-O 1,000 --- --- MΩVI-O = 500 VDC,
RoH 60%
Tu r n - O N t i m e tON --- 2 8 ms IF = 2 mA, RL = 200 Ω,
VDD = 10 V (See note 2.)
Turn-OFF time tOFF --- 0.5 3 ms
VOUT
IF
tON tOFF
10% 90%
IF1
2
4
3
RLVDD
VOUT
Item Symbol Minimum Typical Maximum Unit
Load voltage (AC peak/DC) VDD --- --- 480 V
Operating LED forward current IF--- 2 25 mA
Continuous load current (AC peak/DC) IO--- --- 70 mA
Operating temperature Ta 20 --- 65 °C
MOS FET Relays G3VM-601G 229
Engineering Data
LED forward current vs.
Ambient temperature
IF - Ta
Continuous load current vs.
Ambient temperature
IO - Ta
LED forward current vs.
LED forward voltage
IF - VF
LED forward current I
F
(mA)
0
10
20
30
40
50
60
-40 -20 0 20 40 60 80 100
Continuous load current I
O
(mA)
0
10
20
30
40
50
60
70
80
90
100
-40 -20 0 20 40 60 80 100
LED forward current I
F
(mA)
0.1
1
10
100
0.8 0.9 1.0 1.1 1.2 1.3 1.4
T
a
= 25
Ambient temperature Ta ()
Ambient temperature Taഒ
LED forward voltage V
F
(V)
Continuous load current vs.
On-state voltage
IO - VON
On-state resistance vs.
Ambient temperature
RON - Ta
Trigger LED forward current vs.
Ambient temperature
IFT - Ta
Continuous load current I
O
(mA)
-100
-80
-60
-40
-20
0
20
40
60
80
100
-4-3-2-101234
Ta = 25
IF = 2mA
On-state resistance R
ON
(Ω)
0
10
20
30
40
50
-40 -20 0 20 40 60 80 100
Trigger LED forward current I
FT
(mA)
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
-40 -20 0 20 40 60 80 100
0
On-state voltage V
ON
(V
)
Ambient temperature Ta ()
Ambient temperature Ta ()
Turn ON, Turn OFF time vs.
LED forward current
tON, tOFF - IF
Turn ON, Turn OFF time vs.
Ambient temperature
tON, tOFF - Ta
Current leakage vs.
Ambient temperature
I LEAK - Ta
Turn ON, Turn OFF time t
ON
, t
OFF
(mS)
0.01
0.1
1
10
0.1 1 10 100
Turn ON, Turn OFF time t
ON
, t
OFF
(mS)
0.1
1
10
-40 -20 0 20 40 60 80 100
Current leakage I
LEAK
(nA)
0.001
0.01
0.1
1
10
100
-40-20 0 20406080100
LED forward current I
F
(mA)
Ambient temperature Ta (ഒ
Ambient temperature Ta ()
I
O
= 90mA
I
F
= 2mA
t < 1s
I
O
= 90mA
t < 1s
V
OFF
= 600 V
tON
tOFF
V
DD
= 10V
R
L
= 200 Ω
T
a
= 25
V
DD
= 10V
R
L
= 200 Ω
I
F
= 2mA
tOFF
tON
MOS FET Relays G3VM-601G
OMRON ON-LINE
Global - http://www.omron.com
USA - http://www.components.omron.com
Cat. No. X302-E-1 Printed in USA
OMRON ELECTRONIC
COMPONENTS LLC
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
847-882-2288
12/10 Specifications subject to change without notice
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.