Static Humidity
After exposure part remains within
specified electrical parameters for
L, Q and DCR.
Storage Life
After exposure part remains within
specified electrical parameters for
L, Q and DCR.
After exposure part remains within
10 cycles (Air to Air) 1 cycle shall consist of:
specified electrical parameters for
30 minutes exposure to +85°C
30 minutes exposure to -40°C
Allow 20 minutes transition between extremes.
After exposure part remains within
10 cycles (Air to Air) 1 cycle shall consist of:
specified electrical parameters for
30 minutes exposure to -55°C
30 minutes exposure to +125°C
15 seconds maximum transition between temperatures
Post test parts shall pass all electrical specifications after reflow.
There shall be no visible signs of solder flow or leakage
from the part.
Storage Temperature
Range -40°C to +85°C
Temperature Range -40°C to +85°C
Withstands needle-flame test
Other
After exposure part remains within
1 cycle of 30 minutes of the following:
specified electrical parameters for
5 - 7 Hz constant displacement of 0.75 inches, 5 minutes
7 - 30 Hz constant acceleration of 1.5 Gs, 10 minutes
31 - 50 Hz constant displacement of 0.33 inches, 5 minutes
50 - 500 Hz constant acceleration of 1.2 Gs, 10 minutes
After exposure part remains within
MGDQ1 Series - 500 Gs per axis, 2 directions
specified electrical parameters for
MGDQ2 Series - 500 Gs per axis, 2 directions
MGDQ3 Series - 500 Gs per axis, 2 directions
MGDQ4 Series - 500 Gs per axis, 2 directions
MGDQ5 Series - 500 Gs per axis, 2 directions
MGDQ6 Series - 500 Gs per axis, 2 directions
Solderability
Wetting shall cover 90% minimum of
each termination
Dip pads in RMA
flux, 63/37 solder
(Sn/Pb) at 232°C for
5 seconds ±2
seconds.
Component Adhesion
(Push Test)
Component shall withstand 6 lb. push
force minimum without delaminating
from mounting surface.
Apply and measure force with a digital force gauge set.
Resistance to Solvent Withstands 6 minutes of alcohol.
Withstands 3 minutes forced spray Freon TMS
Chemical
11 µOhms/cm maximum
5.5 to 9
65 ppm maximum
20 ppm maximum
10 ppm maximum
Subject parts to an environment of 85°C 85% R.H. for 168
hours. After exposure allow parts to dry for 4 hours before
Precondition at 25°C for 60 minutes. Expose parts to an
environment of +40°C with 90 to 95% R.H. for 240 hours.
MGDQ6A0For Print Distribution to Customers
Sheet 3 of 6