Economical Load Cell 008638 Model 53 Issue 5 Datasheet FEATURES * * * * * 20 N to 200 kN / 5 lb to 50K lb Stainless steel Mini footprint Button-style design mV/V output POTENTIAL APPLICATIONS * * * * DESCRIPTION The Model 53 load cells are bonded foil strain gage transducers designed for cost efficient production and testing applications (i.e. press calibration). With engineered compression force measurements up to 200 kN / 50k lb, this model achieves a maximum non-linearity of 0.5 % full scale. Precision gaging techniques and a stainless steel construction provide excellent enhanced stability and reliability under severe operating conditions. This compression-only load cell has an integral load button machined as a key part of the design. Installation in application is fixed by three tapped holes to provide secure mounting. VALUE TO CUSTOMERS * Reliable accuracy of 0.5 % * Newton and pound force ranges available Safety and Productivity Solutions Press applications Weighing Sensing for applied load Automation process control PORTFOLIO From general purpose load cells to fatigue-rated, high performance products, Honeywell offers a comprehensive selection of tension, compression, and universal measurement load cell. Each of our load cells can be customized to meet your needs, whatever your application. To view the entire product portfolio, click here. Economical Load Cell, Model 53 Table 1. Performance Specifications Table 5. Wiring Codes Characteristic Measure Cable Load ranges 5 lb, 10 lb, 25 lb, 50 lb, 100 lb, 250 lb, 500 lb, 1K lb, 2K lb, 5K lb, 10K lb, 15K lb, 20K lb, 30K lb, 50K lb 20 N, 50 N, 100 N, 200 N, 500 N, 1 kN, 2 kN, 5 kN, 10 kN, 20 kN, 50 kN, 100 kN, 150 kN, 200 kN Red (+) excitation Black (-) excitation Green (-) output White (+) output Linearity (max.) 0.5 % full scale Hysteresis (max.) 0.3 % full scale Non-repeatability (max.) 0.1 % full scale Output (tolerance) 2 mV/V (nominal) Operation Compression Resolution Infinite Table 2. Environmental Specifications Table 6. Range Codes Range Codes Range Range Codes Range AT 5 lb MI 20 N AV 10 lb MK 50 N BL 25 lb ML 100 N BN 50 lb MM 200 N BR 100 lb MY 500 N CN 250 lb MN 1 kN 500 lb MO 2 kN Characteristic Measure Temperature, operating -53 C to 121 C [-65 F to 250 F] CR Temperature, compensated 15 C to 71 C [60 F to 160 F] CV 1K lb MQ 5 kN Temperature effect, zero 0.01 % full scale/C [0.005 % full scale/F] DL 2K lb MR 10 kN DR 5K lb MS 20 kN Temperature effect, span 0.02 % reading/C [0.01 % reading/F] DV 10K lb MT 50 kN EJ 15K lb MU 100 kN EL 20K lb ZB 150 kN EN 30K lb MV 200 kN EP 50K lb Table 3. Electrical Specifications Characteristic Measure Strain gage type Bonded foil Excitation (calibration) 20 N to 500 N, 5 lb to 100 lb 5 Vdc Excitation (calibration) 1000 N to 200 kN, 250 lb to 50K lb 10 Vdc Insulation resistance Bridge resistance (tolerance) Table 8. Deflections and Ringing Frequencies Capacity Deflection @ full scale Natural ringing frequency Weight with cable g [lb] 5000 Mohm @ 50 Vdc 5 lb/20 N 0,03 mm [0.001 in] 2 KHz 59 [0.13] 350 ohm 10 lb/50 N 0,03 mm [0.001 in] 3 KHz 59 [0.13] Zero balance 3 % full scale 25 lb/100 N 0,03 mm [0.001 in] 16 KHz 62 [0.136] Shunt calibration data Included 50 lb/200 N 0,03 mm [0.001 in] 21 KHz 63 [0.138] Electrical termination (std) Teflon(R) cable (1,5 m [5 ft]) 100 lb/500 N 0,03 mm [0.001 in] 28 KHz 64 [0.141] 250 lb/1 kN 0,03 mm [0.001 in] 25 KHz 72 [0.158] 500 lb 2 kN 0,03 mm [0.001 in] 32 KHz 72 [0.158] Table 4. Mechanical Specifications Characteristic Measure 1000 lb/5 kN 0,03 mm [0.001 in] 42 KHz 75 [0.165] Maximum allowable load 150 %FS 2000 lb/10 kN 0,03 mm [0.001 in] 53 KHz 77 [0.17] Weight see table 5000 lb/20 kN 0,03 mm [0.001 in] 34 KHz 140 [0.306] Material 17-4 PH stainless steel 10K lb/50 kN 0,03 mm [0.001 in] 47 KHz 145 [0.32] Deflection full scale see table 15K lb 0,05 mm [0.002 in] 24 KHz 368 [0.811] Natural frequency see table 20K lb/100 kN 0,05 mm [0.002 in] 28 KHz 372 [0.820] 30K lb/150 kN 0,05 mm [0.002 in] 33 KHz 377 [0.831] 50K lb/200 kN 0,08 mm [0.003 in] 24 KHz 1270 [2.8] 2 sensing.honeywell.com 1 Economical Load Cell, Model 53 Figure 1. Mounting Dimensions: Model 53 (lb) Ranges lb OD1 mm [in] OD2 mm [in] (6E) (6I) 5,80 [0.23] H mm [in] (6E) (6I) (6E) A B mm [in] OG mm [in] #4-40 UNC 5,6 [0.22] 19,05 [0.750] #6-32 UNC 5,1 [0.20] 25,4 [1.000] (6I) 5 lb to 100 lb 25,4 [1.00] 250 lb to 2K lb 31,8 [1.25] 3K lb to 10K lb 38,1 [1.50] 10,2 [0.40] 16,0 [0.63] 2,2 [0.09] #6-32 UNC 5,1 [0.20] 31,75 [1.250] 15K lb to 30K lb 50,8 [2.00] 15,2 [0.60] 25,4 [1.00] 3,0 [0.12] #6-32 UNC 6,4 [0.25] 41,28 [1.625] 50K lb 76,2 [3.00] 19,8 [0.78] 38,1 [1.5] 4,6 [0.18] #6-32 UNC 6,4 [0.25] 60,33 [2.375] H mm [in] L mm [in] A B mm [in] OG mm [in] M3 x 0,5 5,6 [0.22] 19,05 [0.750] M4 x 0,7 5,1 [0.20] 25,4 [1.000] 8,1 [0.32] 7,1 [0.28] 15,7 [0.62] L mm [in] 9,9 [0.39] 17,8 [0.70] 1,3 [0.05] 1,8 [0.07] 1,3 [0.05] Figure 2. Mounting Dimensions: Model 53 (N) Ranges N 20 N to 500 N OD1 mm [in] 25,4 [1.00] OD2 mm [in] (6E) (6I) 5,80 [0.23] 8,1 [0.32] 7,1 [0.28] (6E) (6I) 15,7 [0.62] 9,9 [0.39] 17,8 [0.70] (6E) (6I) 1,3 [0.05] 1,8 [0.07] 1,3 [0.05] 1 kN to 10 kN 31,8 [1.25] 20 kN to 50 kN 38,1 [1.50] 10,2 [0.40] 16,0 [0.63] 2,2 [0.09] M4 x 0,7 6,0 [0.24] 32 [1.260] 100 kN to 150 kN 50,8 [2.00] 15,2 [0.60] 25,4 [1.00] 3,0 [0.12] M4 x 0,7 6,0 [0.24] 41,28 [1.625] 200 kN 76,2 [3.00] 19,8 [0.78] 38,1 [1.5] 4,6 [0.18] M4 x 0,7 6,0 [0.24] 60,00 [2.362] Spherical load button Table 9. Option Codes o D2 L Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell. com/TMsensor-ship for updated listings. H Load range 5 lb, 10 lb, 25 lb, 50 lb, 100 lb, 250 lb, 500 lb, 1K lb, 2K lb, 5K lb, 10K lb, 15K lb, 20K lb, 30K lb, 50K lb 20 N, 50 N, 100 N, 200 N, 500 N, 1 kN, 2 kN, 5 kN, 10 kN, 20 kN, 50 kN, 100 kN, 150 kN, 200 kN Temperature compensation 1a. 15 C to 71 C [60 F to 160 F] Internal amplifiers 2u. Unamplified, mV/V output Electrical termination 6e. Integral cable: Teflon(R) 6i. Integral underwater cable (max. 82 C [180 F]) Additional point calibration 9a. 10 point (5 up/5 down) 20 % increments @ 20 C [68 F] Electrical interfaces4 53s. Phoenix connector and signature calibration module on end of cable 53t. TEDS IEEE 1451.4 module3 o D1 3x A thread B deep on G B.C. 4 conductor, 30 AWG, Teflon(R) insulated shielded cable 1,5 m [5 ft] long with 51 mm [2 in] spring strain relief 1,3 mm [0.05 in] Spherical radius O5,8 mm [0.23 in] 15,7 mm [0.62 in] O25,4 mm [1.00 in] 4 conductor, 30 AWG, Teflon(R) insulated shielded cable 1,5 m [5 ft] long with 51 mm [2 in] spring strain relief 3X "A" thread X "B" deep on "G" B.C. Safety and Productivity Solutions 3 Economical Load Cell, Model 53 Figure 3. Product Nomenclature AL131 MK 1A 2U 6E Load Type Range Temperature Compensation Internal Amplifiers Electrical Termination Model 53 Economical MI Load Cell 20 Newton AT 5 lb MK 50 Newton AV 10 lb ML 100 Newton BL 25 lb MM 200 Newton BN 50 lb MY 500 Newton BR 100 lb MN 1000 Newton CN 250 lb MO 2000 Newton CR 500 lb MQ 5000 Newton CV 1000 lb MR 10,000 Newton DL 2000 lb MS 20,000 Newton DR 5000 lb MT 50,000 Newton DV 10,000 lb MU 100,000 Newton EJ 15,000 lb ZB 150,000 Newton EL 20,000 lb MV 200,000 Newton EN 30,000 lb EP 50,000 lb 4 sensing.honeywell.com Unamplified, C to 71 C 1A 15 [60 F to 160 F] 2U mV/V output 6E Teflon(R), Integral cable 6I Integral underwater cable, 3 m [10 ft] 15C Electrical Conn. Additional Point Calibration Orientation Standard 5-point calibration (None) 10-point 9A calibration Radial 15C exit Calibration Memory4 No storage (none) Phoenix connector Signature 53S with Calibration Module TEDS IEEE 53T 1451.4 module NOTES 1. 2. 3. 4. Allowable maximum loads - maximum load to be applied without damage.2 Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. TEDS IEEE 1454.4 module installed at end of cable. Maximum operating temperature for options 53S and 53T is 85 C [185 F] m WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. m WARNING Figure 4. Typical System Diagram MISUSE OF DOCUMENTATION In-line amplifiers (used with unamplified units only) Amplifier Output Universal in-line amplifiers UV 5 Vdc UV-10 10 Vdc UBP 0 5 Vdc U3W 4 mA to 20 mA (3-wire) DIN rail mount in-line amplifiers DV-05 0 5 Vdc (3-wire) DA-05 4 mA to 20 mA (3-wire) DV-10 0 10 Vdc (3-wire) * * Failure to comply with these instructions could result in death or serious injury. Customer supplied Chart recorder Alarm panel Data acquisition Computer PLC Model 53 Display units SC500 SC2000 SC2001 SC3004 GM NK HH Find out more Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office. The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Warranty/Remedy Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship during the applicable warranty period. Honeywell's standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items that Honeywell, in its sole discretion, finds defective. The foregoing is buyer's sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While Honeywell may provide application assistance personally, through our literature and the Honeywell web site, it is buyer's sole responsibility to determine the suitability of the product in the application. To learn more about Honeywell's Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this writing. test and measurement products, However, Honeywell assumes no responsibility for its use. call +1-815-235-6847 or 1-800-537-6945, visit sensing.honeywell.com, or e-mail inquiries to info.tm@honeywell.com Honeywell Safety and Productivity Solutions 9680 Old Bailes Road Fort Mill, SC 29707 honeywell.com 008638-5-EN IL50 GLO October 2016 (c) 2016 Honeywell International Inc. All rights reserved. Teflon(R) is a registered trademark of E.I. duPont de Nemours