Maximum leakage current each Line to Ground:
3A Models 6A Models
@ 120 VAC 60 Hz: 1.2 mA .7 mA
@250 VAC 50 Hz: 2.3 mA 1.2 mA
Hipot rating (one minute):
Line to Ground: 2250 VDC
Line to Line: 1450 VDC
Rated Voltage (max): 250 VAC
Operating Frequency: 50/60 Hz
Rated Current: 3 or 6A
Operating Ambient Temperature Range
(at rated current Ir): -10°C to +40°C
In an ambient temperature (T
a) higher than +40°C
the maximum operating current (Io) is calculated as
follows: Io= Ir(85-Ta)/45
AQ Series
12
AQ Series
High Frequency Power Line Filter or Power Entry Module
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
For email, phone or live chat, please go to
te.com/help
corcom.com
• Low cost solution to power line noise at high
frequencies
• High common and differential mode performance
from 10kHz to 1GHz
• Available with an IEC inlet, fuseholder and switch
• Suitable for applications where computers are
used to process secret or confidential information
Ordering Information
3 V AQ 8 FS
Suffix
F – Fuseholder
FS – Fuseholder & Switch
(F & FS on VAQ8 only)
Omit if none
Input / Output Style
3 – Wire leads
8 – IEC inlet* (line side)
Wire leads (load side)
AQ Series
Leakage current designation
V – Standard
Current Rating
3 or 6A
Specifications
Electrical Schematics
3A Models
UL Recognized
CSA Certified
6A Models
3VAQ8F
6VAQ8F
Available Part Numbers
3VAQ3 6VAQ3
3VAQ8F 6VAQ8F
3VAQ8FS 6VAQ8FS
*IEC 60320-1 C14 inlet mates with C13 connector
GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord
Accessories