PE68017SNL 4 3 v 2 1 NOTICE: NOTICE: | THIS IS A RoHS COMPLIANT COMPONENT/PRODUCT. RoHS |ALL ENGINEERING CHANGES MUST HAVE PRIOR APPROVAL BY THE DESIGN CENTER. e DATE CODE CTRY ORIGIN " TRANSMIT > TX- 10-4 Og TO- LOW PASS Sie | OWA FILTER aor} 13/4 TX+ 2O- | 10 TD+ 1:1 / CT 50 | T2 | RX- 30O O7 RD- LOW PASS Se | FILTER ar 13/8 RX+ 4 O O8 RD+ 1:1 ~ RECEIVE FINAL OUTLINE SCHEMATIC BIO01961 PE68017SNL 10 DO NOT SCALE DRAWING NONE PE68017SNL7 | 7 OF 7 4 3 4 2 1INSERTION LOSS TEST CIRCUIT FIGURE 4 POLARITY TEST +100 WRONG POLARITY +90 CORRECT POLARITY 0 -90 -100 -180 1 MHZ 10 MHZ 100 MHZ FIGURE 5 BALUN H1008 RECEIVE RETURN LOSS TEST CIRCUIT FIGURE 6 PE68017SNL 4 3 v 2 1 NOTICE: TEST PROCEDURES: BALUN UNLESS OTHERWISE SPECIFIED, TESTING IS PERFORMED AT 25C +5C. H1008 1. HIPOT TEST: (100%) PRODUCTION LINE TO TEST AT 1650 VRMS 1 mA FOR 6 SECONDS, DVT, PILOT LINE AND QUALIFICATION SAMPLES TO TEST AT 1500 VRMS 1 mA FOR 1 MINUTE BETWWEN THE PINS (1 THRU 4) AND (7 THRU 10). BALUN 2. CONNECTIVITY, OPEN AND SHORTS (100%): PER PQ: 3.064.000 H1008 3. INSERTION LOSS: (100%) FIGURE 4 USE FIXTURE ITEM 24 CALIBRATE THE NETWORK ANALYZER IN THE S21 MODE BY SHORTING (1-9) AND SHORT (210) DO A THRU CALIBRATION. MEASURE THE INSERTION LOSS BETWEEN 1 MHZ AND 100 MHZ. THE ATTENUATION SHALL BE WITHIN THE FOLLOWING LIMITS ON BOTH CHANNELS. TRANSMIT (1-3) RECEIVE (5-7) FREQUENCY | ATTENUATION (S21) FREQUENCY | ATTENUATION (S21) 1 MHZ 1.0 dB MAX. 1 MHZ 1.0 dB MAX. 10 MHZ 1.0 dB MAX. 10 MHZ 1.0 dB MAX. 30 MHZ 30 dB MIN. 30 MHZ 10 dB MIN. 50 MHZ 25 dB MIN. 50 MHZ 27 dB MIN. 100 MHZ 27 dB MIN. 100 MHZ 30 dB MIN. 4, POLARITY: (100%) FIGURE 5 USE FIXTURE ITEM 24 CALIBRATE THE SAME AS IN INSERTION LOSS. SET UP PHASE TEST PER FIGURE 4 ON THIS PAGE. PHASE SHALL BE NEGATIVE AND NEAR 45. IF THE PHASE ANGLE IS POSITIVE AT 5 MHZ, THE UNIT IS REJECTED FOR POLARITY REVERSAL. SEE FIGURE 5. 5. RETURN LOSS: (100%) FIGURE 6 USE FIXTURE ITEM 24 CALIBRATE THE NETWORK ANALYZER IN THE S11 MODE. DO ONE PORT FULL CAL WITH PINS 7-8. INSERT PART. MEASURE BOTH RECEIVE AND TRANSMIT TO BE WITHIN THE FOLLOWING LIMITS. FREQUENCY TRANSMIT RECEIVE 5 MHZ 21 dB MIN 20 dB MIN 7.5 MHZ 21 dB MIN -19 dB MIN 10 MHZ -21 dB MIN -20 dB MIN Bi0O1961 PE68017SNL 10 DO NOT SCALE DRAWING NONE PE-68017SNL5 | 5 OF 7 t 2PE68017SNL 2 1 NOTICE: M.U.T. CROSSTALK FIGURE 7 M.U.T. * 50 OHMS +0.1% TEST PROCEDURES: (CONTINUED) 6. CROSSTALK: (SAMPLE TEST) FIGURE 7 USE FIXTURE ITEM 22 CALIBRATE THE NETWORK ANALYZER IN THE S21 MODE BY SHORTING (1-3) AND SHORTING (2-4). DO A THRU CALIBRATION. MEASURE THE CROSSTALK BETWEEN THE TWO CHANNELS OVER THE RANGE OF 5 MHZ TO 50 MHZ. THE CROSSTALK ATTENUATION SHALL BE WITHIN THE FOLLOWING LIMITS: FREQUENCY | ATTENUATION (S21) 5 MHZ 45 dB MIN. 10 MHZ 40 dB MIN. 30 MHZ 30 dB MIN. 50 MHZ 20 dB MIN. 7. COMMON MODE REJECTION: (SAMPLE TEST) FIGURE 8 USE FIXTURE ITEM 23 CALIBRATE THE NETWORK ANALYZER IN THE S21 MODE BY CONNECTING A 50 OHM COAXIAL CABLE BETWEEN THE OUTPUT AND INPUT PORTS OF THE S PARAMETERS TEST SET AND PERFORM A THRU CALIBRATION. REMOVE THE SHORT AND CONNECT THE TEST UNIT PER FIGURE 16. MEASURE THE COMMON MODE REJECTION AT THE FREQUENCIES BELOW. THE COMMON MODE SHALL BE WITHIN THE LIMITS ON BOTH CHANNELS. TRANSMIT (1-2) RECEIVE (3-4) FREQUENCY ATTENUATION (S21) FREQUENCY ATTENUATION (S21) 5 MHZ 35 dB MIN. 5 MHZ 35 dB MIN. 10 MHZ -31 dB MIN. 10 MHZ -30 dB MIN. 30 MHZ 55 dB MIN. 30 MHZ 50 dB MIN. 50 MHZ 55 dB MIN. 45 MHZ 45 dB MIN. 100 MHZ 45 dB MIN. 100 MHZ 45 dB MIN. 200 MHZ 40 dB MIN. 200 MHZ 40 dB MIN. COMMON MODE REJECTION FIGURE 8 Bi01961 PE68017SNL 10 DO NOT SCALE DRAWING NONE PE68017SNL6 | 6 OF 7 t 2