PHONE: (843) 393-5778 FAX: (843) 393-4123 EMAIL: info@magnecraft.com
782 ICE CUBE CONTROL RELAYS
FEATURES BENEFITS
FLAG INDICATOR:
BI - POLAR L.E.D.
STATUS LAMP:
COLOR CODED
PUSH BUTTON:
LOCK-DOWN DOOR:
FINGER - GRIP COVER:
WHITE PLASTIC
I.D. TAG/WRITE LABEL:
COVER ADAPTERS:
VACUUM BAKED & DRY
NITROGEN FILLED (782H):
HERMETICALLY SEALED
METAL ENCLOSURE
(782H):
PLUG-IN STYLE OR SIDE
MOUNTING STUD WITH
ANTI- ROTATION TAB:
SHOWS RELAY STATUS IN MANUAL OR POWERED CONDITION.
ALLOWS FOR REVERSE POLARITY APPLICATIONS,
SHOWS COIL "ON" OR "OFF" STATUS.
IDEAL IN LOW LIGHT CONDITIONS.
IDENTIFIES AC COILS WITH RED OR DC COILS WITH BLUE
PUSH BUTTONS. ALLOWS FOR MANUAL OPERATION OF RELAY
WITHOUT THE NEED FOR COIL POWER. IDEAL FOR
FIELD SERVICE PERSONNEL TO TEST CONTROL CIRCUITS.
WHEN ACTIVATED, HOLDS PUSH BUTTON
AND CONTACTS IN THE OPERATE POSITION.
EXCELLENT FOR ANALYZING CIRCUIT PROBLEMS.
ALLOWS OPERATOR TO REMOVE RELAYS FROM
SOCKETS MORE EASILY THAN CONVENTIONAL RELAYS.
USED FOR IDENTIFICATION OF RELAYS
IN MULTI-RELAY CIRCUITS.
DIN RAIL ADAPTER OR TOP/BOTTOM FLANGE ADAPTER,
ALLOWS THE 700 RELAYS TO BE DIRECT MOUNTED
TO A DIN RAIL OR PANEL.
REMOVES CONTAMINANTS AND PROVIDES A CLEAN
& DRY ATMOSPHERE FOR CONTACTS.
IDEAL FOR USE IN HAZARDOUS LOCATIONS. UL CERTIFIED
FOR CLASS 1 DIVISION 2 GROUP A, B, C & D HAZARDS.
WHEN RELAY IS USED WITH 70-461-1 SOCKET,
THE HOLD-DOWN CLIP 16-1328 IS REQUIRED.
WHEN USED WITH 70-461-1 SOCKET THE 782H CAN BE
DIN RAIL MOUNTED OR PANEL MOUNTED.
THE SIDE STUD PROVIDES FOR DIRECT MOUNT
& SOLDERED WIRE APPLICATIONS.
UL Recognized
File No. E43641(782)
E209950 (782H)
C US
168986
CONTACT
CONFIGURATION
4PDT
CURRENT OR
HORSE POWER
1 AMP
3 AMP
5 AMP
1 AMP
3 AMP
5 AMP
LOAD
VOLTAGE
120/240
120/240
120/240
30
30
30
TYPE OF
LOAD
RESISTIVE
RESISTIVE
RESISTIVE
RESISTIVE
RESISTIVE
RESISTIVE
UL RATINGS FOR 782 HERMETICALLY SEALED
MINIMUM
LOAD
DRY CIRCUIT
100 mA 12 VAC
500 mA 12 VAC
50 mA 5 VAC
100 mA 12 VDC
500 mA 12 VDC
LOAD VOLTAGE
FREQUENCY
50/60 Hz
50/60 Hz
50/60 Hz
DC
DC
DC
MANUFACTURED
UNDER
ISO 9002
& QS 9000
COMPLIES WITH REQUIREMENTS OF
IEC STANDARDS 947-4-1 AND
947-5-1 LOW VOLTAGE DIRECTIVE
IEC = INTERNATIONAL
ELECTROTECHNICAL COMMISSION
CE TESTING AND EVALUATION
PERFORMED BY THE UNDERWRITERS
LABORATORIES AS A THIRD PARTY
PARTICIPANT
*
*
*
LISTED 367G
IND. CONT. EQ.
C US
WHEN USED WITH
SOCKETS:
782: 70-461-1
CURRENT LIMITED
TO RATING OF
RELAY OR SOCKET
WHICHEVER IS LESS
1...19