DS75 Digital Thermometer and Thermostat General Description The DS75 digital thermometer and thermostat provides 9, 10, 11, or 12-bit digital temperature readings over a -55C to +125C range with 2C accuracy over a -25C to +100C range. At power-up, the DS75 defaults to 9-bit resolution for software compatibility with the LM75. Communication with the DS75 is achieved via a simple 2-wire serial interface. Three address pins allow up to eight DS75 devices to operate on the same 2-wire bus, which greatly simplifies distributed temperature sensing applications. The DS75 thermostat has a dedicated open-drain output (O.S.) and programmable fault tolerance, which allows the user to define the number of consecutive error conditions that must occur before O.S is activated. There are two thermostatic operating modes that control thermostat operation based on userdefined trip-points (TOS and THYST). A block diagram of the DS75 is shown in Figure 1 and detailed pin descriptions are given in Table 2. Features Temperature Measurements Require No External Components Measures Temperatures from -55C to +125C (-67F to +257F) 2C Accuracy Over a -25C to +100C Range Thermometer Resolution is User-Configurable from Nine (Default) to 12 Bits (0.5C to 0.0625C Resolution) 9-Bit Conversion Time is 150ms (Max) Thermostatic Settings are User-Definable Data is Read/Written Via 2-Wire Serial (Interface (SDA and SCL Pins) Multidrop Capability Simplifies Distributed Temperature-Sensing Applications Wide Power-Supply Range (+2.7V to +5.5V). Pin/software Compatible with the LM75 Pin Configuration Available in 8-Pin MAX and SO Packages and as a 1.5mm x 1.3mm Flip Chip. See Table 1 for Ordering Information TOP VIEW SDA 1 SCL 2 O.S. GND + 8 VDD 7 A0 3 6 A1 4 5 A2 DS75 DS75S+ (8-Pin SO -- 150mil) SDA 1 SCL 2 O.S. GND + 8 VDD 7 A0 3 6 A1 4 5 A2 DS75 DS75U+ (MAX) 19-7848; Rev 1; 2/08 Applications Include Personal Computers, Cellular Base Stations, Office Equipment, or Any Thermally Sensitive System Pin Description SDA Open-Drain Data I/O SCL Clock Input GND Ground O.S. Open-Drain Thermostat Output A0 A1 Address Input VDD Power Supply A2 Address Input Address Input DS75 Digital Thermometer and Thermostat Table 1. Ordering Information ORDERING NUMBER PACKAGE MARKING DESCRIPTION DS75S+ DS75 (see note) DS75 in Lead-Free 150mil 8-Pin SO DS75S+T&R DS75 (see note) DS75 in Lead-Free 150mil 8-Pin SO, 2500-Piece Tape-and-Reel DS75U+ DS75 (see note) DS75 in Lead-Free 8-Pin MAX DS75U+T&R DS75 (see note) DS75 in Lead-Free 8-Pin MAX, 3000-Piece Tape-and-Reel DS75S DS75 DS75 in 150mil 8-Pin SO DS75S/T&R DS75 DS75 in 150mil 8-Pin SO, 2500-Piece Tape-and-Reel DS75U DS75 DS75 in 8-Pin MAX DS75U/T&R DS75 DS75 in 8-Pin MAX, 3000-Piece Tape-and-Reel DS75X/T&R DS75 DS75 Flip Chip, 10,000-Piece Tape-and-Reel Note: A "+" symbol will also be marked on the package near the Pin 1 indicator Table 2. Detailed Pin Description PIN SYMBOL 1 SDA Data input/output pin for 2-wire serial communication port. Open drain. 2 SCL Clock input pin for 2-wire serial communication port. 3 O.S. Thermostat output. Open drain. 4 GND Ground pin. 5 A2 Address input pin. A0 Address input pin. 6 7 8 A1 VDD www.maximintegrated.com DESCRIPTION Address input pin. Supply Voltage. +2.7V to +5.5V supply pin. Maxim Integrated 2 DS75 Digital Thermometer and Thermostat PRECISION REFERENCE OVERSAMPLING MODULATOR DIGITAL DECIMATOR VDD CONFIGURATION REGISTER SCL SDA A0 A1 A2 ADDRESS AND I/O CONTROL TEMPERATURE REGISTER TOS AND THYST REGISTERS O.S. RP THERMOSTAT COMPARATOR GND Figure 1. DS75 Functional Block Diagram www.maximintegrated.com Maxim Integrated 3 DS75 Digital Thermometer and Thermostat Absolute Maximum Ratings Voltage on VDD, Relative to Ground.....................-0.3V to +7.0V Voltage on any other pin, Relative to Ground................................ -0.3V to (VDD + 0.3V) Operating Temperature..................................... -55C to +125C Storage Temperature......................................... -55C to +125C Soldering Temperature.........................................+260C for 10s *Stresses beyond those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. DC Electrical Characteristics (-55C to +125C; 2.7V VDD 5.5V) PARAMETER Supply Voltage Thermometer Error Input Logic High Input Logic Low SDA Output Logic Low Voltage O.S. Saturation Voltage Input current each I/O pin I/O Capacitance Standby Current Active Current www.maximintegrated.com SYMBOL VDD TERR VIH VIL CONDITION MIN MAX UNITS 2.7 5.5 V -25 to +100 (Note 2) 2.0 -55 to +125 (Note 2) 3.0 (Note 1) (Note 1) 0.7 x VDD VDD + 0.5 0.4 -0.5 0.3 x VDD C V V VOL1 3mA sink current (Note 1) 0 6mA sink current (Note 1) 0 0.6 VOL 4mA sink current (Notes 1, 2) 0.8 V -10 +10 A 10 pF 1 A VOL2 CI/O IDD1 IDD 0.4 < VI/O< 0.9 VDD (Notes 3, 4) Active temp conversions (Notes 3, 4) 1000 Communication only (Notes 3, 4) 100 V A Maxim Integrated 4 DS75 Digital Thermometer and Thermostat AC Electrical Characteristics (-55C to +125C; 2.7V VDD 5.5V) PARAMETER SYMBOL CONDITION Resolution Temperature Conversion Time tCONVT fSCL Bus Free Time Between a STOP and START Condition tBUF Low Period of SCL TYP 9 SCL Frequency START and Repeated START Hold Time from Falling SCL MIN tHD:STA MAX UNITS 12 bits 9-bit conversions 150 10-bit conversions 300 11-bit conversions 600 12-bit conversions 1200 400 ms kHz (Note 5) 1.3 s (Notes 5, 6) 0.6 s tLOW (Note 5) 1.3 s tHIGH (Note 5) 0.6 s Repeated START Condition Setup Time to Rising SCL tSU:STA (Note 5) 0.6 s Data-Out Hold Time from Falling SCL tHD:DAT (Note 5) 0 Data-In Setup Time to Rising SCL tSU:DAT (Note 5) 100 High Period of SCL Rise Time of SDA and SCL Fall Time of SDA and SCL STOP Setup Time to Rising SCL tR tF tSU:STO Capacitive Load for Each Bus Line CB Input Capacitance CI (Notes 5, 7) (Notes 5, 7) (Note 5) 0.9 s ns 20 + 0.1CB 1000 20 + 0.1CB 300 0.6 ns ns s 400 5 pF pF Note 1: All voltages are referenced to ground. Note 2: Internal heating caused by O.S. loading will cause the DS75 to read approximately 0.5C higher if O.S. is sinking the max rated current. Note 3: IDD specified with O.S. pin open. Note 4: IDD specified with VDD at 5.0V and SDA, VSCL = 5.0V, 0C to 70C. Note 5: See Timing Diagram in Figure 2. All timing is referenced to 0.9 x VDD and 0.1 x VDD. Note 6: After this period, the first clock pulse is generated. Note 7: For example, if CB = 300pF, then tR[min] = tF[min] = 50ns. www.maximintegrated.com Maxim Integrated 5 DS75 Digital Thermometer and Thermostat NOTE: THE DS75 DOES NOT DELAY THE SDA LINE INTERNALLY WITH RESPECT TO SCL FOR ANY LENGTH OF TIME. Figure 2. Timing Diagram Operation--Measuring Temperature The DS75 measures temperature using a bandgap temperature sensing architecture. An on-board delta-sigma analog-to-digital converter (ADC) converts the measured temperature to a digital value that is calibrated in degrees centigrade; for Fahrenheit applications a lookup table or conversion routine must be used. The DS75 is factorycalibrated and requires no external components to measure temperature. At power-up the DS75 immediately begins measuring the temperature and converting the temperature to a digital value. The resolution of the digital output data is user-configurable to 9, 10, 11, or 12 bits, corresponding to temperature increments of 0.5C, 0.25C, 0.125C, and 0.0625C, respectively, with 9-bit default resolution at power-up. The resolution is controlled via the R0 and R1 bits in the configuration register as explained in the CONFIGURATION REGISTER section of this data sheet. Note that the conversion time doubles for each additional bit of resolution. www.maximintegrated.com After each temperature measurement and analog-todigital conversion, the DS75 stores the temperature as a 16-bit two's complement number in the 2-byte temperature register (Figure 3). The sign bit (S) indicates if the temperature is positive or negative: for positive numbers S = 0 and for negative numbers S = 1. The most recently converted digital measurement can be read from the temperature register at any time. Since temperature conversions are performed in the background, reading the temperature register does not affect the operation in progress. Bits 3 through 0 of the temperature register are hardwired to 0. When the DS75 is configured for 12-bit resolution, the 12 MSbs (bits 15 through 4) of the temperature register will contain temperature data. For 11-bit resolution, the 11 MSbs (bits 15 through 5) of the temperature register will contain data, and bit 4 will read out as 0. Likewise, for 10-bit resolution, the 10 MSbs (bits 15 through 6) will contain data, and for 9-bit the 9 MSbs (bits 15 through 7) will contain data, and all unused LSbs will contain 0s. Table 3 gives examples of 12-bit resolution digital output data and the corresponding temperatures. Maxim Integrated 6 DS75 Digital Thermometer and Thermostat MS Byte LS Byte bit 15 bit 14 bit 13 bit 12 bit 11 bit 10 bit 9 bit 8 S 26 25 24 23 22 21 20 bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0 2-1 2-2 2-3 2-4 0 0 0 0 Figure 3. Temperature, TH, and TL Register Format Table 3. 12-Bit Resolution Temperature/Data Relationship TEMPERATURE (C) DIGITAL OUTPUT (BINARY) DIGITAL OUTPUT (HEX) 7D00h +125 0111 1101 0000 0000 +25.0625 0001 1001 0001 0000 1910h +10.125 0000 1010 0010 0000 0A20h +0.5 0000 0000 1000 0000 0080h 0 0000 0000 0000 0000 0000h -0.5 1111 1111 1000 0000 FF80h -10.125 1111 0101 1110 0000 F5E0h -25.0625 1110 0110 1111 0000 E6F0h -55 1100 1001 0000 0000 C900h Shutdown Mode For power-sensitive applications, the DS75 offers a lowpower shutdown mode. The SD bit in the configuration register controls shutdown mode. When SD is changed to 1, the conversion in progress will be completed and the result stored in the temperature register after which the DS75 will go into a low-power standby state. The O.S. output will be cleared if the thermostat is operating in interrupt mode and O.S will remain unchanged in comparator mode. The 2-wire interface remains operational in shutdown mode, and writing a 0 to the SD bit returns the DS75 to normal operation. Operation-Thermostat The DS75 thermostat has two operating modes, comparator mode and interrupt mode, which activate and deactivate the open-drain thermostat output (O.S.) based on user-programmable trip-points (TOS and THYST). The DS75 powers up with the thermostat in comparator mode with active-low O.S. polarity and with the overtemperature trip-point (TOS) register set to 80C and the hysteresis trip-point (THYST) register set to 75C. If these power-up settings are compatible with the application, the DS75 can be used as a standalone thermostat (i.e., no 2-wire communication required). If interrupt mode operation, activehigh O.S. polarity or different TOS and THYST values are desired, they must be programmed after powerup, so standalone operation is not possible. www.maximintegrated.com In both operating modes, the user can program the thermostat fault tolerance, which sets how many consecutive temperature readings (1, 2, 4, or 6) must fall outside of the thermostat limits before the thermostat output is triggered. The fault tolerance is set by the F1 and F0 bits in the configuration and at power-up the fault tolerance is 1. The data format of the TOS and THYST registers is identical to that of the temperature register (Figure 3), i.e., a two-byte two's complement representation of the trip-point temperature in degrees centigrade with bits 3 through 0 hardwired to 0. After every temperature conversion, the measured temperature is compared to the values in the TOS and THYST registers, and then O.S. is updated based on the result of the comparison and the operating mode. The number of TOS and THYST bits used during the thermostat comparison is equal to the conversion resolution set by the R1 and R0 bits in the configuration register. For example, it the resolution is 9 bits, only the 9 MSbs of TOS and THYST will be used by the thermostat comparator. The active state of the O.S. output can be changed via the POL bit in the configuration register. The power-up default is active low. If the user does not wish to use the thermostat capabilities of the DS75, the O.S. output should be left floating. Note that if the thermostat is not used, the TOS and THYST registers can be used for general storage of system data. Maxim Integrated 7 DS75 Digital Thermometer and Thermostat Comparator Mode When the thermostat is in comparator mode, O.S. can be programmed to operate with any amount of hysteresis. The O.S. output becomes active when the measured temperature exceeds the TOS value a consecutive number of times as defined by the F1 and F0 fault tolerance (FT) bits in the configuration register. O.S. then stays active until the first time the temperature falls below the value stored in THYST. Putting the device into shutdown mode does not clear O.S. in comparator mode. Thermostat comparator mode operation with FT = 2 is illustrated in Figure 4. Interrupt Mode In interrupt mode, the O.S. output first becomes active when the measured temperature exceeds the TOS value IN THIS EXAMPLE THE DS75 IS CONFIGURED TO HAVE A FAULT TOLERANCE OF 2. a consecutive number of times equal to the FT value in the configuration register. Once activated, O.S. can only be cleared by either putting the DS75 into shutdown mode or by reading from any register (temperature, configuration, TOS, or THYST ) on the device. Once O.S. has been deactivated, it will only be reactivated when the measured temperature falls below the THYST value a consecutive number of times equal to the FT value. Again, O.S can only be cleared by putting the device into shutdown mode or reading any register. Thus, this interrupt/clear process is cyclical between TOS and THYST events (i.e, TOS, clear, THYST, clear, TOS, clear, THYST, clear, etc.). Thermostat interrupt mode operation with FT = 2 is illustrated in Figure 4. TOS TEMPERATURE THYST INACTIVE O.S. OUTPUT - COMPARATOR MODE ACTIVE INACTIVE O.S. OUTPUT - INTERRUPT MODE ACTIVE ASSUMES A READ HAS OCCURRED CONVERSIONS Figure 4. O.S. Output Operation Example www.maximintegrated.com Maxim Integrated 8 DS75 Digital Thermometer and Thermostat Configuration Register The configuration register allows the user to program various DS75 options such as conversion resolution, thermostat fault tolerance, thermostat polarity, thermostat operating mode, and shutdown mode. The configuration register is arranged as shown in Figure 5 and detailed descriptions of each bit are provided in Table 4. The user has read/write access to all bits in the configuration register except the MSb, which is a reserved read-only bit. The entire register is volatile, and thus powers up in its default state. MSb bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 LSb 0 R1 R0 F1 F0 POL TM SD Figure 5. Configuration Register Table 4. Configuration Register Bit Descriptions BIT NAME FUNCTIONAL DESCRIPTION 0 Reserved Power-up state = 0 The master can write to this bit, but it will always read out as a 0. R1 Conversion Resolution Bit 1 Power-up state = 0 Sets conversion resolution (see Table 5) R0 Conversion Resolution Bit 0 Power-up state = 0 Sets conversion resolution (see Table 5) F1 Thermostat Fault Tolerance Bit 1 Power-up state = 0 Sets the thermostat fault tolerance (see Table 6). F0 Thermostat Fault Tolerance Bit 0 Power-up state = 0 Sets the thermostat fault tolerance (see Table 6). POL Thermostat Output (O.S.) Polarity Power-up state = 0 POL = 0 -- O.S. is active low. POL = 1 -- O.S. is active high. TM Thermostat Operating Mode Power-up state = 0 TM = 0 -- Comparator mode. TM = 1 -- Interrupt mode. See the OPERATION-Thermostat section for a detailed description of these modes. SD Shutdown Power-up state = 0 SD = 0 -- Active conversion and thermostat operation. SD = 1 -- Shutdown mode. See the SHUTDOWN MODE section for a detailed description of this mode. Table 5. Resolution Configuration Table 6. Fault Tolerance Configuration THERMOMETER RESOLUTION MAX CONVERSION TIME F1 F0 CONSECUTIVE OUT-OF-LIMITS CONVERSIONS TO TRIGGER O.S. 0 9-bit 150 ms 0 0 1 1 10-bit 300 ms 0 1 2 1 0 11-bit 600 ms 1 0 4 1 1 12-bit 1200 ms 1 1 6 R1 R0 0 0 www.maximintegrated.com Maxim Integrated 9 DS75 Register Pointer The four DS75 registers each have a unique two-bit pointer designation, which is defined in Table 7. When reading from or writing to the DS75, the user must "point" the DS75 to the register that is to be accessed. When reading from the DS75, once the pointer is set, it will remain pointed at the same register until it is changed. For example, if the user desires to perform consecutive reads from the temperature register, then the pointer only has to be set to the temperature register one time, after which all reads will automatically be from the temperature register until the pointer value is changed. On the other hand, when writing to the DS75, the pointer value must be refreshed each time a write is performed even if the same register is being written to twice in a row. At power-up, the default pointer value is the temperature register so the temperature register can be read immediately without resetting the pointer. Changes to the pointer setting are accomplished as described in the 2-WIRE SERIAL DATA BUS section of this datasheet. 2-Wire Serial Data Bus The DS75 communicates over a standard bi-directional 2-wire serial data bus that consists of a serial clock (SCL) signal and serial data (SDA) signal. The DS75 interfaces to the bus via the SCL input pin and open-drain SDA I/O pin. All communication is MSb first. The following terminology is used to describe 2-wire communication: Master Device: Microprocessor/microcontroller that controls the slave devices on the bus. The master device generates the SCL signal and START and STOP conditions. Slave: All devices on the bus other than the master. The DS75 always functions as a slave. Bus Idle or Not Busy: Both SDA and SCL remain high. SDA is held high by a pullup resistor when the bus is idle, and SCL must either be forced high by the master (if the www.maximintegrated.com Digital Thermometer and Thermostat Table 7. Pointer Definition P1 P0 Temperature REGISTER 0 0 Configuration 0 1 THYST 1 0 1 1 TOS SCL output is push-pull) or pulled high by a pullup resistor (if the SCL output is open-drain). Transmitter: A device (master or slave) that is sending data on the bus. Receiver: A device (master or slave) that is receiving data from the bus. START Condition: Signal generated by the master to indicate the beginning of a data transfer on the bus. The master generates a START condition by pulling SDA from high to low while SCL is high (see Figure 6). A "repeated" START is sometimes used at the end of a data transfer (instead of a STOP) to indicate that the master will perform another operation. STOP Condition: Signal generated by the master to indicate the end of a data transfer on the bus. The master generates a STOP condition by transitioning SDA from low to high while SCL is high (see Figure 6). After the STOP is issued, the master releases the bus to its idle state. Acknowledge (ACK): When a device (either master or slave) is acting as a receiver, it must generate an acknowledge (ACK) on the SDA line after receiving every byte of data. The receiving device performs an ACK by pulling the SDA line low for an entire SCL period (see Figure 6). During the ACK clock cycle, the transmitting device must release SDA. A variation on the ACK signal is the "not acknowledge" (NACK). When the master device is acting as a receiver, it uses a NACK instead of an ACK after the last data byte to indicate that it is finished receiving data. The master indicates a NACK by leaving the SDA line high during the ACK clock cycle. Maxim Integrated 10 DS75 Digital Thermometer and Thermostat Slave Address: Every slave device on the bus has a unique 7-bit address that allows the master to access that device. The DS75's 7-bit bus address is 1 0 0 1 A2 A1 A0, where A2, A1 and A0 are user-selectable via the corresponding input pins. The three address pins allow up to eight DS75s to be multi-dropped on the same bus. Address Byte: The control byte is transmitted by the master and consists of the 7-bit slave address plus a read/write (R/W) bit (see Figure 7). If the master is going to read data from the slave device then R/W = 1, and if the master is going to write data to the slave device then R/W = 0. Pointer Byte: The pointer byte is used by the master to tell the DS75 which register is going to be accessed during communication. The six LSbs of the pointer byte (see Figure 8) are always 0 and the two LSbs correspond to the desired register as shown in Table 7. SDA SCL START CONDITION ACK (OR NACK) FROM RECEIVER STOP CONDITION Figure 6. START, STOP, and ACK SIGNALS bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0 1 0 0 1 A2 A1 A0 R/W bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0 0 0 0 0 0 0 P1 P0 Figure 7. Address Byte Figure 8. Pointer Byte www.maximintegrated.com Maxim Integrated 11 DS75 General 2-Wire Information All data is transmitted MSb first over the 2-wire bus. One bit of data is transmitted on the 2-wire bus each SCL period. A pullup resistor is required on the SDA line and, when the bus is idle, both SDA and SCL must remain in a logic-high state. All bus communication must be initiated with a START condition and terminated with a STOP condition. During a START or STOP is the only time SDA is allowed to change states while SCL is high. At all other times, changes on the SDA line can only occur when SCL is low: SDA must remain stable when SCL is high. After every 8-bit (1-byte) transfer, the receiving device must answer with an ACK (or NACK), which takes one SCL period. Therefore, nine clocks are required for every one-byte data transfer. Writing to the DS75 To write to the DS75, the master must generate a START followed by an address byte containing the DS75 bus address. The value of the R/W bit must be a 0, which indicates that a write is about to take place. The DS75 will respond with an ACK after receiving the address byte. This must be followed by a pointer byte from the master, which tells the DS75 which register is being written to. The DS75 will again respond with an ACK after receiving the pointer byte. Following this ACK the master device must immediately begin transmitting data to the DS75. When writing to the configuration register, the master must send one byte of data (see Figure 9a), and when writing to the TOS or THYST registers the master must send two bytes of data (see Figure 9b). After receiving each data byte, the DS75 will respond with an ACK, and the transaction is finished with a STOP from the master. www.maximintegrated.com Digital Thermometer and Thermostat Reading from the DS75 When reading from the DS75, if the pointer was already pointed to the desired register during a previous transaction, the read can be performed immediately without changing the pointer setting. In this case the master sends a START followed by an address byte containing the DS75 bus address. The R/W bit must be a 1, which tells the DS75 that a read is being performed. After the DS75 sends an ACK in response to the address byte, the DS75 will begin transmitting the requested data on the next clock cycle. When reading from the configuration register, the DS75 will transmit one byte of data, after which the master must respond with a NACK followed by a STOP (see Figure 9c). For two-byte reads (i.e., from the Temperature, TOS or THYST register), the DS75 will transmit two bytes of data, and the master must respond to the first data byte with an ACK and to the second byte with a NACK followed by a STOP (see Figure 9d). If only the most significant byte of data is needed, the master can issue a NACK followed by a STOP after reading the first data byte in which case the transaction will be the same as for a read from the configuration register. If the pointer is not already pointing to the desired register, the pointer must first be updated as shown in Figure 9e, which shows a pointer update followed by a single-byte read. The value of the R/W bit in the initial address byte is a 0 ("write") since the master is going to write a pointer byte to the DS75. After the DS75 to the address byte with an ACK, the master sends a pointer byte that corresponds to the desired register. The master must then perform a repeated start followed by a standard one or two byte read sequence (with R/W =1) as described in the previous paragraph. Maxim Integrated 12 www.maximintegrated.com START S 1 0 1 A2 Address Byte 0 A1 A0 START S 1 0 1 A2 Address Byte 0 A1 A0 W A ACK (DS75) A ACK (DS75) W 0 0 0 0 0 0 SCL START S 1 0 1 A2 Address Byte 0 A1 A0 R ACK (DS75) A 0 Pointer Byte 0 D4 D3 Data Byte (from DS75) D7 D6 D5 D2 0 0 A A SCL START S 1 0 1 A2 Address Byte 0 A1 A0 SDA SCL START S 1 0 1 A2 Address Byte 0 A1 A0 e) Read Single Byte (new pointer location) SDA A ACK (DS75) A ACK (DS75) W R 0 0 D4 D3 0 Pointer Byte 0 0 MS Data Byte (from DS75) D7 D6 D5 0 D2 P1 A ACK (DS75) P0 ACK (Master) D1 D0 A NACK (Master) N ACK (DS75) P0 ACK (DS75) 1 D1 D0 P1 0 d) Read 2-Bytes From the Temperature, TOS or THYST Register (current pointer location) SDA 0 Pointer Byte 0 c) Read From the Configuration Register (current pointer location) SDA SCL b) Write to the TOS or THYST Register SDA SCL a) Write to the Configuration Register Repeat START 1 D3 D4 D3 0 1 A2 D2 D2 D2 Address Byte 0 LS Data Byte (from DS75) D7 D6 D5 S D4 MS Data Byte (from Master) D6 D5 P D4 D3 Data Byte (from Master) D6 D5 STOP D7 D7 A A A1 A0 R P P A D3 D4 D3 D2 Data Byte (from DS75) D7 D6 D5 LS Data Byte (from Master) D6 D5 D4 STOP D7 STOP ACK (DS75) NACK (Master) N ACK (DS75) D1 D0 D1 D0 ACK (DS75) D1 D0 D2 A P N P STOP STOP NACK (Master) D1 D0 ACK (DS75) D1 D0 DS75 Digital Thermometer and Thermostat Figure 9. 2-Wire Interface Timing Maxim Integrated 13 DS75 Digital Thermometer and Thermostat Revision History REVISION NUMBER REVISION DATE PAGES CHANGED 0 10/07 Initial release 1 2/08 Deleted all references to flip-chip package and added registered trademark symbol to MAX DESCRIPTION -- 1, 2 For pricing, delivery, and ordering information, please contact Maxim Direct at 1-888-629-4642, or visit Maxim Integrated's website at www.maximintegrated.com. Maxim Integrated cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim Integrated product. No circuit patent licenses are implied. Maxim Integrated reserves the right to change the circuitry and specifications without notice at any time. The parametric values (min and max limits) shown in the Electrical Characteristics table are guaranteed. Other parametric values quoted in this data sheet are provided for guidance. Maxim Integrated and the Maxim Integrated logo are trademarks of Maxim Integrated Products, Inc. (c) 2008 Maxim Integrated Products, Inc. 14 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Maxim Integrated: DS75S+T&R DS75U+T&R DS75S-C11+ DS75S+ DS75U+ DS75S-C11+T&R DS75S