32 Mbit (x16) Multi-Purpose Flash Plus SST39VF3201C / SST39VF3202C A Microchip Technology Company Preliminary Specifications The SST39VF3201C and SST39VF3202C devices are 2M x16, CMOS Multi-Purpose Flash Plus (MPF+) manufactured with SST's proprietary, high performance CMOS SuperFlash technology. The split-gate cell design and thick-oxide tunneling injector attain better reliability and manufacturability compared with alternate approaches. The SST39VF3201C and SST39VF3202C write (Program or Erase) with a 2.7-3.6V power supply. This device conforms to JEDEC standard pinouts for x16 memories. Features * Organized as 2M x16 * Security-ID Feature - SST: 128 bits; User: 128 words * Single Voltage Read and Write Operations * Fast Read Access Time: - 2.7-3.6V - 70 ns * Superior Reliability * Latched Address and Data - Endurance: 100,000 Cycles (Typical) - Greater than 100 years Data Retention * Low Power Consumption (typical values at 5 MHz) - Active Current: 6 mA (typical) - Standby Current: 4 A (typical) - Auto Low Power Mode: 4 A (typical) * Hardware Block-Protection/WP# Input Pin - Uniform 2 KWord sectors * Block-Erase Capability - Flexible block architecture - Eight 4-KWord blocks, 63 32-KWord blocks * Chip-Erase Capability * Erase-Suspend/Erase-Resume Capabilities * Hardware Reset Pin (RST#) (c)2011 Silicon Storage Technology, Inc. - Sector-Erase Time: 18 ms (typical) - Block-Erase Time: 18 ms (typical) - Chip-Erase Time: 35 ms (typical) - Word-Program Time: 7 s (typical) * Automatic Write Timing - Top Block-Protection (top two 4-KWord blocks) for SST39VF3202C - Bottom Block-Protection (bottom two 4-KWord blocks) for SST39VF3201C * Sector-Erase Capability * Fast Erase and Word-Program: - Internal VPP Generation * End-of-Write Detection - Toggle Bits - Data# Polling - RY/BY# Pin * CMOS I/O Compatibility * JEDEC Standard - Flash EEPROM Pin Assignments * Packages Available - 48-lead TSOP (12mm x 20mm) - 48-ball TFBGA (6mm x 8mm) * All devices are RoHS compliant www.microchip.com DS25020A 06/11 32 Mbit Multi-Purpose Flash Plus SST39VF3201C / SST39VF3202C A Microchip Technology Company Preliminary Specifications Product Description The SST39VF3201C and SST39VF3202C devices are 2M x16 CMOS Multi-Purpose Flash Plus (MPF+) manufactured with SST's proprietary, high-performance CMOS SuperFlash technology. The split-gate cell design and thick-oxide tunneling injector attain better reliability and manufacturability compared with alternate approaches. The SST39VF3201C/3202C write (Program or Erase) with a 2.73.6V power supply. These devices conform to JEDEC standard pin assignments for x16 memories. Featuring high performance Word-Program, the SST39VF3201C/3202C devices provide a typical Word-Program time of 7 sec. These devices use Toggle Bit, Data# Polling, or RY/BY# pin to indicate the completion of Program operation. To protect against inadvertent write, they have on-chip hardware and Software Data Protection schemes. Designed, manufactured, and tested for a wide spectrum of applications, these devices are offered with a guaranteed typical endurance of 100,000 cycles. Data retention is rated at greater than 100 years. The SST39VF3201C/3202C devices are suited for applications that require convenient and economical updating of program, configuration, or data memory. For all system applications, they significantly improve performance and reliability, while lowering power consumption. They inherently use less energy during Erase and Program than alternative flash technologies. The total energy consumed is a function of the applied voltage, current, and time of application. Since for any given voltage range, the SuperFlash technology uses less current to program and has a shorter erase time, the total energy consumed during any Erase or Program operation is less than alternative flash technologies. These devices also improve flexibility while lowering the cost for program, data, and configuration storage applications. The SuperFlash technology provides fixed Erase and Program times, independent of the number of Erase/Program cycles that have occurred. Therefore the system software or hardware does not have to be modified or de-rated as is necessary with alternative flash technologies, whose Erase and Program times increase with accumulated Erase/Program cycles. To meet high-density, surface mount requirements, the SST39VF3201C/3202C devices are offered in 48-lead TSOP and 48-ball TFBGA packages. See Figure 2 and Figure 3 for pin assignments. (c)2011 Silicon Storage Technology, Inc. DS25020A 2 06/11 32 Mbit Multi-Purpose Flash Plus SST39VF3201C / SST39VF3202C A Microchip Technology Company Preliminary Specifications Block Diagram X-Decoder Memory Address CE# OE# WE# WP# RESET# RY/BY# SuperFlash Memory Address Buffer Latches Y-Decoder Control Logic I/O Buffers and Data Latches DQ15 - DQ0 1410 B1.0 Figure 1: Functional Block Diagram (c)2011 Silicon Storage Technology, Inc. DS25020A 3 06/11 32 Mbit Multi-Purpose Flash Plus SST39VF3201C / SST39VF3202C A Microchip Technology Company Preliminary Specifications Pin Assignments A15 A14 A13 A12 A11 A10 A9 A8 A19 A20 WE# RST# NC WP# RY/BY# A18 A17 A7 A6 A5 A4 A3 A2 A1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 Standard Pinout Top View Die Up A16 NC VSS DQ15 DQ7 DQ14 DQ6 DQ13 DQ5 DQ12 DQ4 VDD DQ11 DQ3 DQ10 DQ2 DQ9 DQ1 DQ8 DQ0 OE# VSS CE# A0 1410 48-tsop EK P1.0 Figure 2: Pin Assignments for 48-lead TSOP TOP VIEW (balls facing down) 6 5 4 3 2 1 A13 A12 A14 A15 A16 NC DQ15 VSS A8 A10 A11 DQ7 DQ14 DQ13 DQ6 WE# RST# NC A19 DQ5 DQ12 VDD DQ4 RY/BY# WP# A18 A20 DQ2 DQ10 DQ11 DQ3 A9 A7 A17 A6 A5 DQ0 DQ8 DQ9 DQ1 A3 A4 A2 A1 A0 CE# OE# VSS A B C D E F G H 1410 4-tfbga B1K P2.0 Figure 3: Pin assignments for 48-ball TFBGA (c)2011 Silicon Storage Technology, Inc. DS25020A 4 06/11 32 Mbit Multi-Purpose Flash Plus SST39VF3201C / SST39VF3202C A Microchip Technology Company Preliminary Specifications Table 1: Pin Description Symbol Pin Name Functions AMS1-A0 Address Inputs To provide memory addresses. During Sector-Erase AMS-A11 address lines will select the sector. During Block-Erase AMS-A15 address lines will select the block. DQ15-DQ0 Data Input/output To output data during Read cycles and receive input data during Write cycles. Data is internally latched during a Write cycle. The outputs are in tri-state when OE# or CE# is high. WP# Write Protect RST# Reset To reset and return the device to Read mode. CE# Chip Enable To activate the device when CE# is low. OE# Output Enable To gate the data output buffers. WE# Write Enable To control the Write operations. VDD Power Supply To provide power supply voltage: 2.7-3.6V VSS Ground To protect the top/bottom boot block from Erase/Program operation when grounded. NC No Connection Unconnected pins. RY/BY# Ready/Busy# To output the status of a Program or Erase operation RY/BY# is a open drain output, so a 10K - 100K pull-up resistor is required to allow RY/BY# to transition high indicating the device is ready to read. T1.0 25020 1. AMS = Most significant address AMS = A20 for SST39VF3201C/3202C (c)2011 Silicon Storage Technology, Inc. DS25020A 5 06/11 32 Mbit Multi-Purpose Flash Plus SST39VF3201C / SST39VF3202C A Microchip Technology Company Preliminary Specifications Table 2: Top / Bottom Boot Block Address (1 of 2) Top Boot Block Address SST39VF3202C # Size (KWord) 70 4 1FF000H-1FFFFFH 69 4 1FE000H-1FEFFFH 68 4 1FD000H-1FDFFFH 67 4 1FC000H-1FCFFFH 66 4 65 4 64 63 62 61 60 32 1E0000H-1E7FFFH 59 32 1D8000H-1DFFFFH 58 32 1D0000H-1D7FFFH 57 32 1C8000H-1CFFFFH 56 32 55 32 54 53 Bottom Boot Block Address SST39VF3201C Size (KWord) Address Range 70 32 1F8000H-1FFFFFH 69 32 1F0000H-1F7FFFH 68 32 1E8000H-1EFFFFH 67 32 1E0000H-1E7FFFH 1FB000H-1FBFFFH 66 32 1D8000H-1DFFFFH 1FA000H-1FAFFFH 65 32 1D0000H-1D7FFFH 4 1F9000H-1F9FFFH 64 32 1C8000H-1CFFFFH 4 1F8000H-1F8FFFH 63 32 1C0000H-1C7FFFH 32 1F0000H-1F7FFFH 62 32 1B8000H-1BFFFFH 32 1E8000H-1EFFFFH 61 32 1B0000H-1B7FFFH 60 32 1A8000H-1AFFFFH 59 32 1A0000H-1A7FFFH 58 32 198000H-19FFFFH 57 32 190000H-197FFFH 1C0000H-1C7FFFH 56 32 188000H-18FFFFH 1B8000H-1BFFFFH 55 32 180000H-187FFFH 32 1B0000H-1B7FFFH 54 32 178000H-17FFFFH 32 1A8000H-1AFFFFH 53 32 170000H-177FFFH 52 32 1A0000H-1A7FFFH 52 32 168000H-16FFFFH 51 32 198000H-19FFFFH 51 32 160000H-167FFFH 50 32 190000H-197FFFH 50 32 158000H-15FFFFH 49 32 188000H-18FFFFH 49 32 150000H-157FFFH 48 32 180000H-187FFFH 48 32 148000H-14FFFFH 47 32 178000H-17FFFFH 47 32 140000H-147FFFH 46 32 170000H-177FFFH 46 32 138000H-13FFFFH 45 32 168000H-16FFFFH 45 32 130000H-137FFFH 44 32 160000H-167FFFH 44 32 128000H-12FFFFH 43 32 158000H-15FFFFH 43 32 120000H-127FFFH 42 32 150000H-157FFFH 42 32 118000H-11FFFFH 41 32 148000H-14FFFFH 41 32 110000H-117FFFH 40 32 140000H-147FFFH 40 32 108000H-10FFFFH 39 32 138000H-13FFFFH 39 32 100000H-107FFFH 38 32 130000H-137FFFH 38 32 0F8000H-0FFFFFH 37 32 128000H-12FFFFH 37 32 0F0000H-0F7FFFH 36 32 120000H-127FFFH 36 32 0E8000H-0EFFFFH 35 32 118000H-11FFFFH 35 32 0E0000H-0E7FFFH 34 32 110000H-117FFFH 34 32 0D8000H-0DFFFFH 33 32 108000H-10FFFFH 33 32 0D0000H-0D7FFFH 32 32 100000H-107FFFH 32 32 0C8000H-0CFFFFH 31 32 0F8000H-0FFFFFH 31 32 0C0000H-0C7FFFH Address Range (c)2011 Silicon Storage Technology, Inc. # DS25020A 6 06/11 32 Mbit Multi-Purpose Flash Plus SST39VF3201C / SST39VF3202C A Microchip Technology Company Preliminary Specifications Table 2: Top / Bottom Boot Block Address (Continued) (2 of 2) 30 32 0F0000H-0F7FFFH 30 32 0B8000H-0BFFFFH 29 32 0E8000H-0EFFFFH 29 32 0B0000H-0B7FFFH 28 32 0E0000H-0E7FFFH 28 32 0A8000H-0AFFFFH 27 32 0D8000H-0DFFFFH 27 32 0A0000H-0A7FFFH 26 32 0D0000H-0D7FFFH 26 32 098000H-09FFFFH 25 32 0C8000H-0CFFFFH 25 32 090000H-097FFFH 24 32 0C0000H-0C7FFFH 24 32 088000H-08FFFFH 23 32 0B8000H-0BFFFFH 23 32 080000H-087FFFH 22 32 0B0000H-0B7FFFH 22 32 078000H-07FFFFH 21 32 0A8000H-0AFFFFH 21 32 070000H-077FFFH 20 32 0A0000H-0A7FFFH 20 32 068000H-06FFFFH 19 32 098000H-09FFFFH 19 32 060000H-067FFFH 18 32 090000H-097FFFH 18 32 058000H-05FFFFH 17 32 088000H-08FFFFH 17 32 050000H-057FFFH 16 32 080000H-087FFFH 16 32 048000H-04FFFFH 15 32 078000H-07FFFFH 15 32 040000H-047FFFH 14 32 070000H-077FFFH 14 32 038000H-03FFFFH 13 32 068000H-06FFFFH 13 32 030000H-037FFFH 12 32 060000H-067FFFH 12 32 028000H-02FFFFH 11 32 058000H-05FFFFH 11 32 020000H-027FFFH 10 32 050000H-057FFFH 10 32 018000H-01FFFFH 9 32 048000H-04FFFFH 9 32 010000H-017FFFH 8 32 040000H-047FFFH 8 32 008000H-00FFFFH 7 32 038000H-03FFFFH 7 4 007000H-007FFFH 6 32 030000H-037FFFH 6 4 006000H-006FFFH 5 32 028000H-02FFFFH 5 4 005000H-005FFFH 4 32 020000H-027FFFH 4 4 004000H-004FFFH 3 32 018000H-01FFFFH 3 4 003000H-003FFFH 2 32 010000H-017FFFH 2 4 002000H-002FFFH 1 32 008000H-00FFFFH 1 4 001000H-001FFFH 0 32 000000H-007FFFH 0 4 000000H-000FFFH T2.25020 (c)2011 Silicon Storage Technology, Inc. DS25020A 7 06/11 32 Mbit Multi-Purpose Flash Plus SST39VF3201C / SST39VF3202C A Microchip Technology Company Preliminary Specifications Device Operation Commands are used to initiate the memory operation functions of the device. Commands are written to the device using standard microprocessor write sequences. A command is written by asserting WE# low while keeping CE# low. The address bus is latched on the falling edge of WE# or CE#, whichever occurs last. The data bus is latched on the rising edge of WE# or CE#, whichever occurs first. The SST39VF3201C/3202C also have the Auto Low Power mode which puts the device in a near standby mode after data has been accessed with a valid Read operation. This reduces the IDD active read current from typically 9 mA to typically 4 A. The Auto Low Power mode reduces the typical IDD active read current to the range of 2 mA/MHz of Read cycle time. The device exits the Auto Low Power mode with any address transition or control signal transition used to initiate another Read cycle, with no access time penalty. Note that the device does not enter Auto-Low Power mode after power-up with CE# held steadily low, until the first address transition or CE# is driven high. Read The Read operation of the SST39VF3201C/3202C is controlled by CE# and OE#, both have to be low for the system to obtain data from the outputs. CE# is used for device selection. When CE# is high, the chip is deselected and only standby power is consumed. OE# is the output control and is used to gate data from the output pins. The data bus is in high impedance state when either CE# or OE# is high. Refer to the Read cycle timing diagram for further details (Figure 5). Word-Program Operation The SST39VF3201C/3202C are programmed on a word-by-word basis. Before programming, the sector where the word exists must be fully erased. The Program operation is accomplished in three steps. The first step is the three-byte load sequence for Software Data Protection. The second step is to load word address and word data. During the Word-Program operation, the addresses are latched on the falling edge of either CE# or WE#, whichever occurs last. The data is latched on the rising edge of either CE# or WE#, whichever occurs first. The third step is the internal Program operation which is initiated after the rising edge of the fourth WE# or CE#, whichever occurs first. The Program operation, once initiated, will be completed within 10 s. See Figure 6 and Figure 7 for WE# and CE# controlled Program operation timing diagrams and Figure 21 for flowcharts. During the Program operation, the only valid reads are Data# Polling and Toggle Bit. During the internal Program operation, the host is free to perform additional tasks. Any commands issued during the internal Program operation are ignored. During the command sequence, WP# should be statically held high or low. Sector/Block-Erase Operation The Sector- (or Block-) Erase operation allows the system to erase the device on a sector-by-sector (or block-by-block) basis. The SST39VF3201C/3202C offer both Sector-Erase and Block-Erase mode. The sector architecture is based on uniform sector size of 2 KWord. The Block-Erase mode is based on block sizes of 4 and 32 KWord. The Sector-Erase operation is initiated by executing a six-byte command sequence with Sector-Erase command (50H) and sector address (SA) in the last bus cycle. The Block-Erase operation is initiated by executing a six-byte command sequence with Block-Erase command (30H) and block address (BA) in the last bus cycle. The sector or block address is latched on the falling edge of the sixth WE# pulse, while the command (50H or 30H) is latched on the rising edge of the sixth WE# pulse. The internal Erase operation begins after the sixth WE# pulse. The End-of-Erase operation can be determined using either Data# Polling or Toggle Bit methods. See Figure 11 and Fig- (c)2011 Silicon Storage Technology, Inc. DS25020A 8 06/11 32 Mbit Multi-Purpose Flash Plus SST39VF3201C / SST39VF3202C A Microchip Technology Company Preliminary Specifications ure 12 for timing waveforms and Figure 25 for the flowchart. Any commands issued during the Sectoror Block-Erase operation are ignored. When WP# is low, any attempt to Sector- (Block-) Erase the protected block will be ignored. During the command sequence, WP# should be statically held high or low. Erase-Suspend/Erase-Resume Commands The Erase-Suspend operation temporarily suspends a Sector- or Block-Erase operation thus allowing data to be read from any memory location, or program data into any sector/block that is not suspended for an Erase operation. The operation is executed by issuing one byte command sequence with EraseSuspend command (B0H). The device automatically enters read mode typically within 10 s after the Erase-Suspend command had been issued. Valid data can be read from any sector or block that is not suspended from an Erase operation. Reading at address location within erase-suspended sectors/ blocks will output DQ2 toggling and DQ6 at `1'. While in Erase-Suspend mode, a Word-Program operation is allowed except for the sector or block selected for Erase-Suspend. To resume Sector-Erase or Block-Erase operation which has been suspended the system must issue Erase Resume command. The operation is executed by issuing one byte command sequence with Erase Resume command (30H) at any address in the last Byte sequence. Chip-Erase Operation The SST39VF3201C/3202C provide a Chip-Erase operation, which allows the user to erase the entire memory array to the "1" state. This is useful when the entire device must be quickly erased. The Chip-Erase operation is initiated by executing a six-byte command sequence with Chip-Erase command (10H) at address 555H in the last byte sequence. The Erase operation begins with the rising edge of the sixth WE# or CE#, whichever occurs first. During the Erase operation, the only valid read is Toggle Bit or Data# Polling. See Table 7 for the command sequence, Figure 10 for timing diagram, and Figure 25 for the flowchart. Any commands issued during the Chip-Erase operation are ignored. When WP# is low, any attempt to Chip-Erase will be ignored. During the command sequence, WP# should be statically held high or low. Write Operation Status Detection The SST39VF3201C/3202C provide two software means to detect the completion of a Write (Program or Erase) cycle, in order to optimize the system write cycle time. The software detection includes two status bits: Data# Polling (DQ7) and Toggle Bit (DQ6). The End-of-Write detection mode is enabled after the rising edge of WE#, which initiates the internal Program or Erase operation. The actual completion of the nonvolatile write is asynchronous with the system; therefore, either a Data# Polling or Toggle Bit read may be simultaneous with the completion of the write cycle. If this occurs, the system may possibly get an erroneous result, i.e., valid data may appear to conflict with either DQ7 or DQ6. In order to prevent spurious rejection, if an erroneous result occurs, the software routine should include a loop to read the accessed location an additional two (2) times. If both reads are valid, then the device has completed the Write cycle, otherwise the rejection is valid. (c)2011 Silicon Storage Technology, Inc. DS25020A 9 06/11 32 Mbit Multi-Purpose Flash Plus SST39VF3201C / SST39VF3202C A Microchip Technology Company Preliminary Specifications Data# Polling (DQ7) When the SST39VF3201C/3202C are in the internal Program operation, any attempt to read DQ7 will produce the complement of the true data. Once the Program operation is completed, DQ7 will produce true data. Note that even though DQ7 may have valid data immediately following the completion of an internal Write operation, the remaining data outputs may still be invalid: valid data on the entire data bus will appear in subsequent successive Read cycles after an interval of 1 s. During internal Erase operation, any attempt to read DQ7 will produce a `0'. Once the internal Erase operation is completed, DQ7 will produce a `1'. The Data# Polling is valid after the rising edge of fourth WE# (or CE#) pulse for Program operation. For Sector-, Block- or Chip-Erase, the Data# Polling is valid after the rising edge of sixth WE# (or CE#) pulse. See Figure 8 for Data# Polling timing diagram and Figure 22 for a flowchart. Toggle Bits (DQ6 and DQ2) During the internal Program or Erase operation, any consecutive attempts to read DQ6 will produce alternating "1"s and "0"s, i.e., toggling between 1 and 0. When the internal Program or Erase operation is completed, the DQ6 bit will stop toggling. The device is then ready for the next operation. For Sector, Block-, or Chip-Erase, the toggle bit (DQ6) is valid after the rising edge of sixth WE# (or CE#) pulse. DQ6 will be set to `1' if a Read operation is attempted on an Erase-Suspended Sector/Block. If Program operation is initiated in a sector/block not selected in Erase-Suspend mode, DQ6 will toggle. An additional Toggle Bit is available on DQ2, which can be used in conjunction with DQ6 to check whether a particular sector is being actively erased or erase-suspended. Table 3 shows detailed status bits information. The Toggle Bit (DQ2) is valid after the rising edge of the last WE# (or CE#) pulse of Write operation. See Figure 9 for Toggle Bit timing diagram and Figure 22 for a flowchart. Table 3: Write Operation Status Status Normal Operation Erase-Suspend Mode DQ7 DQ6 DQ2 RY/BY# DQ7# Toggle No Toggle 0 Standard Erase 0 Toggle Toggle 0 Read from Erase-Suspended Sector/Block 1 1 Toggle 1 Read from Non- EraseSuspended Sector/Block Data Data Data 1 Program DQ7# Toggle N/A 0 Standard Program T3.0 25020 Note: DQ7, DQ6 and DQ2 require a valid address when reading status information. (c)2011 Silicon Storage Technology, Inc. DS25020A 10 06/11 32 Mbit Multi-Purpose Flash Plus SST39VF3201C / SST39VF3202C A Microchip Technology Company Preliminary Specifications Ready/Busy# (RY/BY#) The devices include a Ready/Busy# (RY/BY#) output signal. RY/BY# is an open drain output pin that indicates whether an Erase or Program operation is in progress. Since RY/BY# is an open drain output, it allows several devices to be tied in parallel to VDD via an external pull-up resistor. After the rising edge of the final WE# pulse in the command sequence, the RY/BY# status is valid. When RY/BY# is actively pulled low, it indicates that an Erase or Program operation is in progress. When RY/BY# is high (Ready), the devices may be read or left in standby mode. Data Protection The SST39VF3201C/3202C provide both hardware and software features to protect nonvolatile data from inadvertent writes. Hardware Data Protection Noise/Glitch Protection: A WE# or CE# pulse of less than 5 ns will not initiate a write cycle. VDD Power Up/Down Detection: The Write operation is inhibited when VDD is less than 1.5V. Write Inhibit Mode: Forcing OE# low, CE# high, or WE# high will inhibit the Write operation. This prevents inadvertent writes during power-up or power-down. Hardware Block Protection The SST39VF3202C support top hardware block protection, which protects the top two 4-KWord blocks of the device. The SST39VF3201C support bottom hardware block protection, which protects the bottom two 4-KWord blocks of the device. The Boot Block address ranges are described in Table 4. Program and Erase operations are prevented on the two 4-KWord blocks when WP# is low. If WP# is left floating, it is internally held high via a pull-up resistor, and the Boot Block is unprotected, enabling Program and Erase operations on that block. Table 4: Boot Block Address Ranges Product Address Range Bottom Boot Block SST39VF3201C 000000H-001FFFH Top Boot Block SST39VF3202C 1FE000H-1FFFFFH T4.0 25020 Hardware Reset (RST#) The RST# pin provides a hardware method of resetting the device to read array data. When the RST# pin is held low for at least TRP, any in-progress operation will terminate and return to Read mode. When no internal Program/Erase operation is in progress, a minimum period of TRHR is required after RST# is driven high before a valid Read can take place. See Figure 17. The Erase or Program operation that has been interrupted needs to be re-initiated after the device resumes normal operation mode to ensure data integrity. (c)2011 Silicon Storage Technology, Inc. DS25020A 11 06/11 32 Mbit Multi-Purpose Flash Plus SST39VF3201C / SST39VF3202C A Microchip Technology Company Preliminary Specifications Software Data Protection (SDP) The SST39VF3201C/3202C provide the JEDEC approved Software Data Protection scheme for all data alteration operations, i.e., Program and Erase. Any Program operation requires the inclusion of the three-byte sequence. The three-byte load sequence is used to initiate the Program operation, providing optimal protection from inadvertent Write operations, e.g., during the system power-up or powerdown. Any Erase operation requires the inclusion of six-byte sequence. These devices are shipped with the Software Data Protection permanently enabled. See Table 7 for the specific software command codes. During SDP command sequence, invalid commands will abort the device to read mode within TRC. The contents of DQ15-DQ8 can be VIL or VIH, but no other value, during any SDP command sequence. Common Flash Memory Interface (CFI) The SST39VF3201C/3202C also contain the CFI information to describe the characteristics of the device. In order to enter the CFI Query mode, the system must write the three-byte sequence, same as product ID entry command with 98H (CFI Query command) to address 555H in the last byte sequence. The system can also enter the CFI Query mode, by using the one-byte sequence with 55H on Address and 98H on Data Bus. Once the device enters the CFI Query mode, the system can read CFI data at the addresses given in Tables 8 through 10. The system must write the CFI Exit command to return to Read mode from the CFI Query mode. Product Identification The Product Identification mode identifies the devices as the SST39VF3201Cand SST39VF3202C, and the manufacturer as SST. This mode may be accessed through software operations. Users may use the Software Product Identification operation to identify the part (i.e., using the device ID) when using multiple manufacturers in the same socket. For details, see Table 7 for software operation, Figure 13 for the Software ID Entry and Read timing diagram and Figure 23 for the Software ID Entry command sequence flowchart. Table 5: Product Identification Address Data 0000H BFH SST39VF3201C 0001H 235F SST39VF3202C 0001H 235E Manufacturer's ID Device ID T5.0 25020 Product Identification Mode Exit/CFI Mode Exit In order to return to the standard Read mode, the Software Product Identification mode must be exited. Exit is accomplished by issuing the Software ID Exit command sequence, which returns the device to the Read mode. This command may also be used to reset the device to the Read mode after any inadvertent transient condition that apparently causes the device to behave abnormally, e.g., not read correctly. Please note that the Software ID Exit/CFI Exit command is ignored during an internal Program or Erase operation. See Table 7 for software command codes, Figure 15 for timing waveform, and Figure 23 and Figure 24 for flowcharts. (c)2011 Silicon Storage Technology, Inc. DS25020A 12 06/11 32 Mbit Multi-Purpose Flash Plus SST39VF3201C / SST39VF3202C A Microchip Technology Company Preliminary Specifications Security ID The SST39VF3201C/3202C devices offer a 136 word Security ID space. The Secure ID space is divided into two segments - one factory programmed segment and one user programmed segment. The first segment is programmed and locked at SST with a random 128-bit number. The 128-word user segment is left un-programmed for the customer to program as desired. To program the user segment of the Security ID, the user must use the Security ID Word-Program command. To detect end-of-write for the SEC ID, read the toggle bits. Do not use Data# Polling. Once this is complete, the Sec ID should be locked using the User Sec ID Program Lock-Out. This disables any future corruption of this space. Note that regardless of whether or not the Sec ID is locked, neither Sec ID segment can be erased. The Secure ID space can be queried by executing a three-byte command sequence with Enter Sec ID command (88H) at address 555H in the last byte sequence. To exit this mode, the Exit Sec ID command should be executed. Refer to Table 7 for more details. (c)2011 Silicon Storage Technology, Inc. DS25020A 13 06/11 32 Mbit Multi-Purpose Flash Plus SST39VF3201C / SST39VF3202C A Microchip Technology Company Preliminary Specifications Operations Table 6: Operation Modes Selection Mode CE# OE# WE# DQ Address Read VIL VIL VIH DOUT AIN Program VIL VIH VIL DIN AIN VIL X1 Sector or block address, XXH for Chip-Erase Erase VIL Standby VIH X X High Z X X VIL X High Z/ DOUT X X X VIH High Z/ DOUT X VIL VIL VIH Write Inhibit VIH Product Identification Software Mode See Table 7 T6.0 25020 1. X can be VIL or VIH, but no other value. Table 7: Software Command Sequence Command Sequence 1st Bus Write Cycle 2nd Bus Write Cycle Addr1 Addr1 Data2 Addr1 Data2 Addr1 Data2 Data AAH Data2 3rd Bus Write Cycle 4th Bus Write Cycle Word-Program 555H AAH 2AAH 55H 555H A0H WA3 Sector-Erase 555H AAH 2AAH 55H 555H 80H 555H 5th Bus Write Cycle 6th Bus Write Cycle Addr1 Data2 Addr1 Data2 2AAH 55H SAX4 4 50H Block-Erase 555H AAH 2AAH 55H 555H 80H 555H AAH 2AAH 55H BAX 30H Chip-Erase 555H AAH 2AAH 55H 555H 80H 555H AAH 2AAH 55H 555H 10H Erase-Suspend XXXXH B0H Erase-Resume XXXXH 30H ID5 555H AAH 2AAH 55H 555H 88H User Security ID Word-Program 555H AAH 2AAH 55H 555H A5H WA6 Data User Security ID Program Lock-Out 555H AAH 2AAH 55H 555H 85H XXH6 0000H Software ID Entry7,8 555H AAH 2AAH 55H 555H 90H CFI Query Entry 555H AAH 2AAH 55H 555H 98H CFI Query Entry 55H 98H Software ID Exit9,10 /CFI Exit/Sec ID Exit 555H AAH 2AAH 55H 555H F0H Software ID Exit9,10 /CFI Exit/Sec ID Exit XXH F0H Query Sec T7.0 25020 1. Address format A10-A0 (Hex). Addresses A11- A20 can be VIL or VIH, but no other value, for Command sequence for SST39VF3201C/3202C. 2. DQ15-DQ8 can be VIL or VIH, but no other value, for Command sequence 3. WA = Program Word address 4. SAX for Sector-Erase; uses AMS-A11 address lines BAX, for Block-Erase; uses AMS-A15 address lines AMS = Most significant address AMS = A20 for SST39VF3201C/3202C (c)2011 Silicon Storage Technology, Inc. DS25020A 14 06/11 32 Mbit Multi-Purpose Flash Plus SST39VF3201C / SST39VF3202C A Microchip Technology Company Preliminary Specifications 5. With AMS-A4 = 0; Sec ID is read with A3-A0, SST ID is read with A3 = 0 (Address range = 000000H to 000007H), User ID is read with A3 = 1 (Address range = 000008H to 000087H). Lock Status is read with A7-A0 = 0000FFH. Unlocked: DQ3 = 1 / Locked: DQ3 = 0. 6. Valid Word-Addresses for Sec ID are from 000000H-000007H and 000008H to 000087H. 7. The device does not remain in Software Product ID Mode if powered down. 8. For Manufacture ID With AMS-A0 =0;SST Manufacturer ID = 00BFH is read For Device ID Device ID can be read either in one cycle (address 01H) or in three cycles (addresses 01H, 0EH and 0FH) One-cycle method With AMS-A1=0, A0=1; SST39VF3201C/3202C Device ID = 235F/235E is read Three-cycle method With AMS-A1=0, A0=1; SST39VF3201C/3202C Device ID = 235F/235E is read (cycle 1) With AMS-A4=0; A3-A1=1; A0=0; SST39VF3201C/3202C Device ID additional info = 1A/1A is read (Note: 1A = 32 Mbit) (cycle 2) With AMS-A4=0; A3-A0=1; SST39VF3201C/3202C Device ID additional info = 00/01 is read (00/01 = Bottom/Top Boot) (cycle 3) AMS = Most significant address AMS = A20 for SST39VF3201C/3202C 9. Both Software ID Exit operations are equivalent 10. If users never lock after programming, Sec ID can be programmed over the previously unprogrammed bits (data=1) using the Sec ID mode again (the programmed "0" bits cannot be reversed to "1"). Valid Word-Addresses for Sec ID are from 000000H-000007H and 000008H to 000087H. Table 8: CFI Query Identification String1 for SST39VF3201C/3202C Address Data 10H 0051H 11H 0052H 12H 0059H 13H 0002H 14H 0000H 15H 0000H 16H 0000H 17H 0000H 18H 0000H 19H 0000H 1AH 0000H Data Query Unique ASCII string "QRY" Primary OEM command set Address for Primary Extended Table Alternate OEM command set (00H = none exists) Address for Alternate OEM extended Table (00H = none exits) T8.0 25020 1. Refer to CFI publication 100 for more details. (c)2011 Silicon Storage Technology, Inc. DS25020A 15 06/11 32 Mbit Multi-Purpose Flash Plus SST39VF3201C / SST39VF3202C A Microchip Technology Company Preliminary Specifications Table 9: System Interface Information for SST39VF3201C/3202C Address Data 1BH 0027H 1CH 0036H Data VDD Min (Program/Erase) DQ7-DQ4: Volts, DQ3-DQ0: 100 millivolts VDD Max (Program/Erase) DQ7-DQ4: Volts, DQ3-DQ0: 100 millivolts 1DH 0000H VPP min. (00H = no VPP pin) 1EH 0000H VPP max. (00H = no VPP pin) 1FH 0003H Typical time out for Word-Program 2N s (23 = 8 s) 20H 0000H Typical time out for min. size buffer program 2N s (00H = not supported) 21H 0004H Typical time out for individual Sector/Block-Erase 2N ms (24 = 16 ms) 22H 0005H Typical time out for Chip-Erase 2N ms (25 = 32 ms) 23H 0001H Maximum time out for Word-Program 2N times typical (21 x 23 = 16 s) 24H 0000H Maximum time out for buffer program 2N times typical 25H 0001H Maximum time out for individual Sector/Block-Erase 2N times typical (21 x 24 = 32 ms) 26H 0001H Maximum time out for Chip-Erase 2N times typical (21 x 25 = 64 ms) T9.0 25020 Table 10:Device Geometry Information for SST39VF3201C/3202C Address Data Data 27H 0016H Device size = 2N Bytes (16H = 22; 222 = 4MByte) 28H 0001H Flash Device Interface description; 0001H = x16-only asynchronous interface 29H 0000H 2AH 0000H 2BH 0000H 2CH 0003H Number of Erase Sector/Block sizes supported by device 2DH 0007H Erase Block1 region information. 2EH 0000H 2FH 0020H 30H 0000H 31H 003EH 32H 0000H 33H 0000H 34H 0001H 35H 0000H 36H 0000H 37H 0000H 38H 0000H 39H 0000H 3AH 0000H 3BH 0000H 3CH 0000H Maximum number of bytes in multi-byte write = 2N (00H = not supported) Erase Block2 region information. Erase Block3 region information. Erase Block4 region information. T10.0 25020 (c)2011 Silicon Storage Technology, Inc. DS25020A 16 06/11 32 Mbit Multi-Purpose Flash Plus SST39VF3201C / SST39VF3202C A Microchip Technology Company Preliminary Specifications Absolute Maximum Stress Ratings (Applied conditions greater than those listed under "Absolute Maximum Stress Ratings" may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these conditions or conditions greater than those defined in the operational sections of this data sheet is not implied. Exposure to absolute maximum stress rating conditions may affect device reliability.) Temperature Under Bias . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -55C to +125C Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -65C to +150C D. C. Voltage on Any Pin to Ground Potential . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.5V to VDD+0.5V Transient Voltage (<20 ns) on Any Pin to Ground Potential . . . . . . . . . . . . . . . . . . -2.0V to VDD+2.0V Voltage on A9 Pin to Ground Potential . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.5V to 13.2V Package Power Dissipation Capability (TA = 25C) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.0W Surface Mount Solder Reflow Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . 260C for 10 seconds Output Short Circuit Current1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 mA 1. Outputs shorted for no more than one second. No more than one output shorted at a time. Table 11:Operating Range Range Commercial Industrial Ambient Temp VDD 0C to +70C 2.7-3.6V -40C to +85C 2.7-3.6V T11.1 25020 Table 12:AC Conditions of Test1 Input Rise/Fall Time Output Load 5ns CL = 30 pF T12.1 25020 1. See Figures 19 and 20 (c)2011 Silicon Storage Technology, Inc. DS25020A 17 06/11 32 Mbit Multi-Purpose Flash Plus SST39VF3201C / SST39VF3202C A Microchip Technology Company Preliminary Specifications Power Up Specifications All functionalities and DC specifications are specified for a VDD ramp rate of greater than 1V per 100 ms (0V to 3V in less than 300 ms). If the VDD ramp rate is slower than 1V per 100 ms, a hardware reset is required. The recommended VDD power-up to RESET# high time should be greater than 100 s to ensure a proper reset. TPU-READ 10 0 s VDD min VDD 0V VIH RESET# TRHR 50 ns CE# 1410 F24.0 Figure 4: Power-Up Diagram Table 13:DC Operating Characteristics VDD = 2.7-3.6V1 Limits Symbol Parameter IDD Power Supply Current Max Units Read3 Program and Erase Standby VDD Current Auto Low Power 15 45 50 50 mA mA A A ILI ILIW Input Leakage Current Input Leakage Current on WP# pin and RST# 1 10 A A Test Conditions Address input=VILT/VIHT2, at f=5 MHz, VDD=VDD Max CE#=VIL, OE#=WE#=VIH, all I/Os open CE#=WE#=VIL, OE#=VIH CE#=VIHC, VDD=VDD Max CE#=VILC, VDD=VDD Max All inputs=VSS or VDD, WE#=VIHC VIN=GND to VDD, VDD=VDD Max WP#=GND to VDD or RST#=GND to VDD ILO VIL VILC VIH VIHC VOL VOH Output Leakage Current Input Low Voltage Input Low Voltage (CMOS) Input High Voltage 0.7VDD Input High Voltage (CMOS) VDD-0.3 Output Low Voltage Output High Voltage VDD-0.2 1 0.8 0.3 A V V V V V V VOUT=GND to VDD, VDD=VDD Max VDD=VDD Min VDD=VDD Max VDD=VDD Max VDD=VDD Max IOL=100 A, VDD=VDD Min IOH=-100 A, VDD=VDD Min ISB IALP Min 0.2 T13.0 25020 1. Typical conditions for the Active Current shown on the front page of the data sheet are average values at 25C (room temperature), and VDD = 3V. Not 100% tested. 2. See Figure 19 3. The IDD current listed is typically less than 2mA/MHz, with OE# at VIH. Typical VDD is 3V. (c)2011 Silicon Storage Technology, Inc. DS25020A 18 06/11 32 Mbit Multi-Purpose Flash Plus SST39VF3201C / SST39VF3202C A Microchip Technology Company Preliminary Specifications Table 14:Recommended System Power-up Timings Symbol Parameter Minimum Units TPU-READ1 Power-up to Read Operation 100 s Power-up to Program/Erase Operation 100 s TPU-WRITE 1 T14.0 25020 1. This parameter is measured only for initial qualification and after a design or process change that could affect this parameter. Table 15:Capacitance (TA = 25C, f=1 Mhz, other pins open) Parameter CI/O 1 CIN1 Description Test Condition Maximum I/O Pin Capacitance VI/O = 0V 10 pF Input Capacitance VIN = 0V 10 pF T15.0 25020 1. This parameter is measured only for initial qualification and after a design or process change that could affect this parameter. Table 16:Reliability Characteristics Symbol NEND1,2 TDR1 ILTH1 Parameter Endurance Data Retention Latch Up Minimum Specification 10,000 100 100 + IDD Units Cycles Years mA Test Method JEDEC Standard A117 JEDEC Standard A103 JEDEC Standard 78 T16.0 25020 1. This parameter is measured only for initial qualification and after a design or process change that could affect this parameter. 2. NEND endurance rating is qualified as a 10,000 cycle minimum for the whole device. A sector- or block-level rating would result in a higher minimum specification. (c)2011 Silicon Storage Technology, Inc. DS25020A 19 06/11 32 Mbit Multi-Purpose Flash Plus SST39VF3201C / SST39VF3202C A Microchip Technology Company Preliminary Specifications AC Characteristics Table 17:Read Cycle Timing Parameters VDD = 2.7-3.6V Symbol Parameter Min Max Units TRC Read Cycle Time TCE Chip Enable Access Time 70 70 ns ns TAA Address Access Time 70 ns TOE Output Enable Access Time 35 ns 1 CE# Low to Active Output 0 ns TOLZ1 OE# Low to Active Output 0 ns TCHZ1 CE# High to High-Z Output 16 ns TOHZ1 OE# High to High-Z Output 16 ns TCLZ 1 0 ns TRP1 RST# Pulse Width 500 ns TRHR1 RST# High before Read 50 TRY1,2 RST# Pin Low to Read Mode TOH Output Hold from Address Change ns 20 s T17.0 25020 1. This parameter is measured only for initial qualification and after a design or process change that could affect this parameter. 2. This parameter applies to Sector-Erase, Block-Erase, and Program operations. This parameter does not apply to Chip-Erase operations. Table 18:Program/Erase Cycle Timing Parameters Symbol Parameter TBP Word-Program Time Min Max Units 10 s TAS Address Setup Time 0 ns TAH Address Hold Time 30 ns TCS WE# and CE# Setup Time 0 ns TCH WE# and CE# Hold Time 0 ns TOES OE# High Setup Time 0 ns TOEH OE# High Hold Time 10 ns TCP CE# Pulse Width 40 ns TWP WE# Pulse Width 40 ns TWPH1 TCPH1 WE# Pulse Width High 30 ns CE# Pulse Width High 30 ns TDS Data Setup Time 30 ns TDH1 Data Hold Time 0 ns TIDA1 Software ID Access and Exit Time 150 ns TSE Sector-Erase 25 ms TBE Block-Erase 25 ms TSCE Chip-Erase 50 ms TBY1,2 TBR1 RY/BY# Delay Time 0 s 90 Bus Recovery Time ns T18.0 25020 1. This parameter is measured only for initial qualification and after a design or process change that could affect this parameter. 2. This parameter applies to Sector-Erase, Block-Erase, and Program operations. (c)2011 Silicon Storage Technology, Inc. DS25020A 20 06/11 32 Mbit Multi-Purpose Flash Plus SST39VF3201C / SST39VF3202C A Microchip Technology Company Preliminary Specifications TRC TAA ADDRESS AMS-0 TCE CE# TOE OE# TOHZ TOLZ VIH WE# TCLZ DQ15-0 TCHZ TOH HIGH-Z DATA VALID HIGH-Z DATA VALID 1410 F03.0 Note: AMS = Most significant address AMS = A20 for SST39VF3201C/3202C Figure 5: Read Cycle Timing Diagram TBP ADDRESSES 555 2AA 555 ADDR TAH TWP WE# TWPH TAS OE# TCH CE# TCS TBY TBR RY/BY# TDS DQ15-0 XXAA XX55 XXA0 TDH DATA WORD (ADDR/DATA) VALID 1410 F04.0 Note: WP# must be held in proper logic state (VIL or VIH) 1s prior to and 1s after the command sequence. X can be VIL or VIH, but no other value. Figure 6: WE# Controlled Program Cycle Timing Diagram (c)2011 Silicon Storage Technology, Inc. DS25020A 21 06/11 32 Mbit Multi-Purpose Flash Plus SST39VF3201C / SST39VF3202C A Microchip Technology Company Preliminary Specifications TBP ADDRESSES 555 2AA 555 ADDR TAH TCP WE# TAS TCPH OE# TCH CE# TCS TBY TBR RY/BY# TDS DQ15-0 XXAA XX55 XXA0 TDH DATA VALID WORD (ADDR/DATA) 1410 F05.0 Note: WP# must be held in proper logic state (VIL or VIH) 1s prior to and 1s after the command sequence. X can be VIL or VIH, but no other value. Figure 7: CE# Controlled Program Cycle Timing Diagram ADDRESS A19-0-AMS-0 TCE CE# TOEH TOES OE# TOE WE# TBY RY/BY# DQ7 DATA# DATA DATA# DATA 1410 F06.0 Note: AMS = Most significant address AMS = A20 for SST39VF3201C/3202C Figure 8: Data# Polling Timing Diagram (c)2011 Silicon Storage Technology, Inc. DS25020A 22 06/11 32 Mbit Multi-Purpose Flash Plus SST39VF3201C / SST39VF3202C A Microchip Technology Company Preliminary Specifications ADDRESS AMS-0 TCE CE# TOEH TOES TOE OE# WE# DQ6 and DQ2 TWO READ CYCLES WITH SAME OUTPUTS 1410 F07.0 Note: AMS = Most significant address AMS = A20 for SST39VF3201C/3202C Figure 9: Toggle Bits Timing Diagram TSCE SIX-BYTE CODE FOR CHIP-ERASE ADDRESSES 555 2AA 555 555 2AA 555 CE# OE# TOEH WE# TBY TBR RY/BY# DQ15-0 XXAA XX55 XX80 XXAA XX55 XX10 VALID 1410 F08.0 Note: This device also supports CE# controlled Chip-Erase operation The WE# and CE# signals are interchangeable as long as minimum timings are met. (See Table 18) WP# must be held in proper logic state (VIL or VIH) 1 s prior to and 1 s after the command sequence. X can be VIL or VIH, but no other value. Figure 10:WE# Controlled Chip-Erase Timing Diagram (c)2011 Silicon Storage Technology, Inc. DS25020A 23 06/11 32 Mbit Multi-Purpose Flash Plus SST39VF3201C / SST39VF3202C A Microchip Technology Company Preliminary Specifications TBE SIX-BYTE CODE FOR BLOCK-ERASE ADDRESSES 555 2AA 555 555 2AA BAX CE# OE# TWP WE# TBR TBY RY/BY# DQ15-0 XXAA XX55 XXAA XX80 XX55 XX30 VALID 1410 F09.0 Note: This device also supports CE# controlled Block-Erase operation. The WE# and CE# signals are interchangeable as long as minimum timings are met. (See Table 18). BAX = Block Address WP# must be held in proper logic state (VIL or VIH) 1s prior to and 1s after the command sequence. X can be VIL or VIH, but no other value. Figure 11:WE# Controlled Block-Erase Timing Diagram TSE SIX-BYTE CODE FOR SECTOR-ERASE ADDRESSES 555 2AA 555 555 2AA SAX CE# OE# TWP WE# TBY TBR RY/BY# DQ15-0 XXAA XX55 XX80 XXAA XX55 XX50 VALID 1410 F10.0 Note: This device also supports CE# controlled Sector-Erase operation. The WE# and CE# signals are interchangeable as long as minimum timings are met. (See Table 18). SAX = Block Address WP# must be held in proper logic state (VIL or VIH) 1s prior to and 1s after the command sequence. X can be VIL or VIH, but no other value. Figure 12:WE# Controlled Sector-Erase Timing Diagram (c)2011 Silicon Storage Technology, Inc. DS25020A 24 06/11 32 Mbit Multi-Purpose Flash Plus SST39VF3201C / SST39VF3202C A Microchip Technology Company Preliminary Specifications Three-Byte Sequence for Software ID Entry ADDRESS 555 2AA 555 0000 0001 CE# OE# TIDA TWP WE# TWPH DQ15-0 TAA XXAA XX55 XX90 SW0 SW1 SW2 00BF Device ID 1410 F11.0 Note: Device ID = 235E for SST39VF3201Cand 235E for SST39VF3202C WP# must be held in proper logic state (VIL or VIH) 1 s prior to and 1 s after the command sequence. X can be VIL or VIH, but no other value. Figure 13:Software ID Entry and Read Three-Byte Sequence for CFI Query Entry ADDRESS 555 2AA 555 CE# OE# TIDA TWP WE# TWPH DQ15-0 TAA XXAA XX55 XX98 SW0 SW1 SW2 1410 F12.0 Note: WP# must be held in proper logic state (VIL or VIH) 1 s prior to and 1 s after the command sequence. X can be VIL or VIH, but no other value. Figure 14:CFI Query Entry and Read (c)2011 Silicon Storage Technology, Inc. DS25020A 25 06/11 32 Mbit Multi-Purpose Flash Plus SST39VF3201C / SST39VF3202C A Microchip Technology Company Preliminary Specifications THREE-BYTE SEQUENCE FOR SOFTWARE ID EXIT AND RESET ADDRESS A14-0 DQ15-0 555 2AA XXAA 555 XX55 XXF0 TIDA CE# OE# TWP WE# TWHP SW0 SW1 SW2 1410 F13.0 Note: WP# must be held in proper logic state (VIL or VIH) 1 s prior to and 1 s after the command sequence. X can be VIL or VIH, but no other value. Figure 15:Software ID Exit/CFI Exit THREE-BYTE SEQUENCE FOR CFI QUERY ENTRY ADDRESS AMS-0 555 2AA 555 CE# OE# TIDA TWP WE# TWPH DQ15-0 TAA XXAA XX55 XX88 SW0 SW1 SW2 1410 F14.0 Note: AMS = Most significant address AMS = A20 for SST39VF3201C/3202C WP# must be held in proper logic state (VIL or VIH) 1 s prior to and 1 s after the command sequence. X can be VIL or VIH, but no other value. Figure 16:Sec ID Entry (c)2011 Silicon Storage Technology, Inc. DS25020A 26 06/11 32 Mbit Multi-Purpose Flash Plus SST39VF3201C / SST39VF3202C A Microchip Technology Company Preliminary Specifications RY/BY# 0V TRP RST# TRHR CE#/OE# 1410 F15.0 Figure 17:RST# Timing Diagram (When no internal operation is in progress) TRY RY/BY# TRP RST# CE# TBR OE# 1410 F16.0 Figure 18:RST# Timing Diagram (During Program or Erase operation) (c)2011 Silicon Storage Technology, Inc. DS25020A 27 06/11 32 Mbit Multi-Purpose Flash Plus SST39VF3201C / SST39VF3202C A Microchip Technology Company Preliminary Specifications VIHT INPUT VIT REFERENCE POINTS VOT OUTPUT VILT 1410 F17.0 AC test inputs are driven at VIHT (0.9 VDD) for a logic "1" and VILT (0.1 VDD) for a logic "0". Measurement reference points for inputs and outputs are VIT (0.5 VDD) and VOT (0.5 VDD). Input rise and fall times (10% 90%) are <5 ns. Note: VIT - VINPUT Test VOT - VOUTPUT Test VIHT - VINPUT HIGH Test VILT - VINPUT LOW Test Figure 19:AC Input/Output Reference Waveforms TO TESTER TO DUT CL 1410 F18.0 Figure 20:A Test Load Example (c)2011 Silicon Storage Technology, Inc. DS25020A 28 06/11 32 Mbit Multi-Purpose Flash Plus SST39VF3201C / SST39VF3202C A Microchip Technology Company Preliminary Specifications Start Load data: XXAAH Address: 555H Load data: XX55H Address: 2AAH Load data: XXA0H Address: 555H Load Word Address/Word Data Wait for end of Program (TBP, Data# Polling bit, or Toggle bit operation) Program Completed X can be VIL or VIH, but no other value 1410 F19.0 Figure 21:Word-Program Algorithm (c)2011 Silicon Storage Technology, Inc. DS25020A 29 06/11 32 Mbit Multi-Purpose Flash Plus SST39VF3201C / SST39VF3202C A Microchip Technology Company Preliminary Specifications Internal Timer Toggle Bit Data# Polling RY/BY# Program/Erase Initiated Program/Erase Initiated Program/Erase Initiated Program/Erase Initiated Wait TBP, TSCE, TSE or TBE Read word Read DQ7 Read RY/BY# Read same word Program/Erase Completed No Is DQ7 = true data No Is RY/BY# = 1 Yes Yes No Does DQ6 match Program/Erase Completed Program/Erase Completed Yes Program/Erase Completed 1410 F20.0 Figure 22:Wait Options (c)2011 Silicon Storage Technology, Inc. DS25020A 30 06/11 32 Mbit Multi-Purpose Flash Plus SST39VF3201C / SST39VF3202C A Microchip Technology Company Preliminary Specifications CFI Query Entry Command Sequence Sec ID Query Entry Software Product ID Entry Command Sequence Command Sequence Load data: XXAAH Address: 555H Load data: XX98H Address: 55H Load data: XXAAH Address: 555H Load data: XXAAH Address: 555H Load data: XX55H Address: 2AAH Wait TIDA Load data: XX55H Address: 2AAH Load data: XX55H Address: 2AAH Load data: XX98H Address: 555H Read CFI data Load data: XX88H Address: 555H Load data: XX90H Address: 555H Wait TIDA Wait TIDA Wait TIDA Read CFI data Read Sec ID Read Software ID X can be VIL or VIH, but no other value 1410 F21.0 Figure 23:Software ID/CFI Entry Command Flowcharts (c)2011 Silicon Storage Technology, Inc. DS25020A 31 06/11 32 Mbit Multi-Purpose Flash Plus SST39VF3201C / SST39VF3202C A Microchip Technology Company Preliminary Specifications Software ID Exit/CFI Exit/Sec ID Exit Command Sequence Load data: XXAAH Address: 555H Load data: XXF0H Address: XXH Load data: XX55H Address: 2AAH Wait TIDA Load data: XXF0H Address: 555H Return to normal operation Wait TIDA Return to normal operation X can be VIL or VIH, but no other value 1410 F22.0 Figure 24:Software ID/CFI Exit Command Flowcharts (c)2011 Silicon Storage Technology, Inc. DS25020A 32 06/11 32 Mbit Multi-Purpose Flash Plus SST39VF3201C / SST39VF3202C A Microchip Technology Company Preliminary Specifications Chip-Erase Command Sequence Sector-Erase Command Sequence Block-Erase Command Sequence Load data: XXAAH Address: 555H Load data: XXAAH Address: 555H Load data: XXAAH Address: 555H Load data: XX55H Address: 2AAH Load data: XX55H Address: 2AAH Load data: XX55H Address: 2AAH Load data: XX80H Address: 555H Load data: XX80H Address: 555H Load data: XX80H Address: 555H Load data: XXAAH Address: 555H Load data: XXAAH Address: 555H Load data: XXAAH Address: 555H Load data: XX55H Address: 2AAH Load data: XX55H Address: 2AAH Load data: XX55H Address: 2AAH Load data: XX10H Address: 555H Load data: XX50H Address: SAX Load data: XX30H Address: BAX Wait TSCE Wait TSE Wait TBE Chip erased to FFFFH Sector erased to FFFFH Block erased to FFFFH X can be VIL or VIH, but no other value 1410 F23.0 Figure 25:Erase Command Sequence (c)2011 Silicon Storage Technology, Inc. DS25020A 33 06/11 32 Mbit Multi-Purpose Flash Plus SST39VF3201C / SST39VF3202C A Microchip Technology Company Preliminary Specifications Product Ordering Information SST 39 VF XX XX 3201C XXXXX - 70 XX - 4I XX - EKE XXX Environmental Attribute E1 = non-Pb Package Modifier K = 48 balls or leads Package Type E = TSOP (type1, die up, 12mm x 20mm) B3 = TFBGA (6mm x 8mm, 0.8mm pitch) Temperature Range C = Commercial = 0C to +70C I = Industrial = -40C to +85C Minimum Endurance 4 = 10,000 cycles Read Access Speed 70 = 70 ns Hardware Block Protection 1 = Bottom Boot-Block 2 = Top Boot-Block Device Density 320= 32Mbit Voltage V = 2.7-3.6V Product Series 39 = Multi-Purpose Flash Plus 1. Environmental suffix "E" denotes non-Pb solder. SST non-Pb solder devices are "RoHS Compliant". Valid Combinations for SST39VF3201C SST39VF3201C-70-4I-EKE SST39VF3201C-70-4C-EKE SST39VF3201C-70-4I-B3KE SST39VF3201C-70-4C-B3KE Valid Combinations for SST39VF3202C SST39VF3202C-70-4I-EKE SST39VF3202C-70-4C-EKE SST39VF3202C-70-4I-B3KE SST39VF3202C-70-4C-B3KE Note:Valid combinations are those products in mass production or will be in mass production. Consult your SST sales representative to confirm availability of valid combinations and to determine availability of new combinations. (c)2011 Silicon Storage Technology, Inc. DS25020A 34 06/11 32 Mbit Multi-Purpose Flash Plus SST39VF3201C / SST39VF3202C A Microchip Technology Company Preliminary Specifications Packaging Diagrams 1.05 0.95 Pin # 1 Identifier 0.50 BSC 0.27 0.17 12.20 11.80 0.15 0.05 18.50 18.30 DETAIL 1.20 max. 0.70 0.50 20.20 19.80 0- 5 Note: 1. Complies with JEDEC publication 95 MO-142 DD dimensions, although some dimensions may be more stringent. 2. All linear dimensions are in millimeters (max/min). 1mm 3. Coplanarity: 0.1 mm 4. Maximum allowable mold flash is 0.15 mm at the package ends, and 0.25 mm between leads. 0.70 0.50 48-tsop-EK-8 Figure 26:48-lead Thin Small Outline Package (TSOP) 12mm x 20mm, SST Package Code: EK (c)2011 Silicon Storage Technology, Inc. DS25020A 35 06/11 32 Mbit Multi-Purpose Flash Plus SST39VF3201C / SST39VF3202C A Microchip Technology Company Preliminary Specifications TOP VIEW BOTTOM VIEW 5.60 8.00 0.10 0.45 0.05 (48X) 0.80 6 6 5 5 4.00 4 4 6.00 0.10 3 3 2 2 1 1 0.80 A B C D E F G H A1 CORNER SIDE VIEW H G F E D C B A A1 CORNER 1.10 0.10 0.12 SEATING PLANE 1mm 0.35 0.05 Note: 1. Complies with JEDEC Publication 95, MO-210, variant AB-1 , although some dimensions may be more stringent. 2. All linear dimensions are in millimeters. 3. Coplanarity: 0.12 mm 4. Ball opening size is 0.38 mm ( 0.05 mm) 48-tfbga-B3K-6x8-450mic-5 Figure 27:48-ball Thin-profile, Fine-pitch Ball Grid Array (TFBGA) 6mm x 8mm, SST Package Code: B3K (c)2011 Silicon Storage Technology, Inc. DS25020A 36 06/11 32 Mbit Multi-Purpose Flash Plus SST39VF3201C / SST39VF3202C A Microchip Technology Company Preliminary Specifications Table 19:Revision History Number 00 01 A Description * * * * * Initial release Revised ISB and IALP in Table 13 on page 19 Applied new document format Released document under letter revision system Updated spec number from S71410 to DS25020 Date Nov 2009 Aug 2010 Jun 2011 ISBN:978-1-61341-239-8 (c) 2011 Silicon Storage Technology, Inc-a Microchip Technology Company. All rights reserved. SST, Silicon Storage Technology, the SST logo, SuperFlash, MTP, and FlashFlex are registered trademarks of Silicon Storage Technology, Inc. MPF, SQI, Serial Quad I/O, and Z-Scale are trademarks of Silicon Storage Technology, Inc. All other trademarks and registered trademarks mentioned herein are the property of their respective owners. Specifications are subject to change without notice. Refer to www.microchip.com for the most recent documentation. For the most current package drawings, please see the Packaging Specification located at http://www.microchip.com/packaging. Memory sizes denote raw storage capacity; actual usable capacity may be less. SST makes no warranty for the use of its products other than those expressly contained in the Standard Terms and Conditions of Sale. For sales office(s) location and information, please see www.microchip.com. Silicon Storage Technology, Inc. A Microchip Technology Company www.microchip.com (c)2011 Silicon Storage Technology, Inc. DS25020A 37 06/11