Agilent 34137A Test Lead Set
Opera ti ng Instructions
This Test Lead Set is designed for use only with the Agilent 3458A Multimeter.
Do not use with other A gil ent meter s.
Assistance
For technical assistance, contact your nearest Agilent Sales Office. Or visit the
Agilent web site at www.agilent.com/find/assist for further information.
Agilent Technologies, Inc.
900 S. Taft Avenue
Loveland, CO 80537 U.S.A.
Symbols
Refer to instrument manual for additional safety information.
CAT II IEC Measurement Category II. Refer to instrument manual for
additional information.
Ratings Quantity
Test Lead 1 000V , 15A 2 pieces
Fine Tip Probe Attachments 300V, 3A 2 pieces
Mini Grabber Attachment 300V, 3A 1 piece
SMT Grabber Attachments 300V, 3A 2 pieces
Operation
Refer to the multimeter user’s guide for further information.
The Fine Tip, Mini Grabber, and SMT Grabber attachments plug onto the
probe end of the Test Leads.
WARNING: If Test Lead Set is used in a manner not specified by Agilent
Technologies, the protection provided by the Test Lead Set may be impaired.
Instrument damage or personal injury may result.
Maintenance
If any portion of the Test Lead Set is worn or damaged, do not use; replace with a
new Test Lead Set.
*34137-90000*
E1212 34137-90000
Agilent 34137A Test Lead Set
Opera ti ng Instructions
This Test Lead Set is designed for use only with the Agilent 3458A Multimeter.
Do not use with other A gil ent meter s.
Assistance
For technical assistance, contact your nearest Agilent Sales Office. Or visit the
Agilent web site at www.agilent.com/find/assist for further information.
Agilent Technologies, Inc.
900 S. Taft Avenue
Loveland, CO 80537 U.S.A.
Symbols
Refer to instrument manual for additional safety information.
CAT II IEC Measurement Category II. Refer to instrument manual for
additional information.
Ratings Quantity
Test Lead 1 000V , 15A 2 pieces
Fine Tip Probe Attachments 300V, 3A 2 pieces
Mini Grabber Attachment 300V, 3A 1 piece
SMT Grabber Attachments 300V, 3A 2 pieces
Operation
Refer to the multimeter users guide for further information.
The Fine Tip, Mini Grabber, and SMT Grabber attachments plug onto the
probe end of the Test Leads.
WARNING: If Test Lead Set is used in a manner not specified by Agilent
Technologies, the protection provided by the Test Lead Set may be impaired.
Instrument damage or personal injury may result.
Maintenance
If any portion of the Test Lead Set is worn or damaged, do not use; replace with a
new Test Lead Set.
*34137-90000*
E1212 34137-90000
© Agilent Technologies, Inc. 2012 December 2012