JNPS-0814
10
Table 1: ENVIROMENTAL TEST
ITEM TEST CONDITION RELATED STANDARD
MOISTURE -10 ∼ 65°C, Relative Humidity 95% / 10 cycles MIL-STD-202F106D
SALT SPRAY NaCl 5% solution, 35°C / 48 hours MIL-STD-202F101D
THERMAL SHOCK -55°C→25°C→85°C→25°C / 5 cycles MIL-STD-202F107G
HUMIDITY
(STEADY STATE) 40°C, Relative Humidity 95% / 96 hours MIL-STD-202F103B
THERMAL LIFE Steady Current: Current Rating × 110%, 85°C / 1000 hours ――――
H2S GAS 3 ± 1 ppm, 40°C, Relative Humidity 70 ∼ 80% / 96 hours JEIDA-38-1984
VIBRATION
Sweep Freq.: 10 ∼ 55Hz, Amplitude: 1.52mm (or 98 m/s2)
Sweep Cycle: 1 min., Sweep time: 2 hours
Sweep Directions: X, Y, Z
MIL-STD-202F201A
MECHANICAL
SHOCK
490 m/s2, 11ms, Half sine shock pulse.
3 times / X,Y,Z directions (Total 9 times) MIL-STD-202E213B
7. PLATING SPEC INDICATION ON CONNECTOR
The first letter, in stamped 3 letters on the connector body for lot numbering, identified the following
plating specs.
R XX : PL plating
Z XX : PE plating
Y XX : PC plating
* XX : two alphabet letters
8. PACKAGE & IDENTIFICATION
These products are packed with plastic tray and carton box for transit.
Carton box is identified by part number, quantity, maker name and lot number.
9. STORAGE
This products shall be stored in a room, ambient temperature 5 ∼ 35°C, and ambient humidity
40 ∼ 70%.