4117 Open Type>>>>>Dust Covered >> 13.2x14x18 18x16.4x20 Features Superminiature, heavy power. Low coil power consumption. Switching current up to 2x10A. PC board mounting. Suitable for household appliance, electrical equipment, automation system, and automobile industry application. Ordering Information 4117 C S 10 12VDC 1.0 1 2 3 4 5 6 1 Part number4117 2 Contact arrangementA:1AB:1BC:1CU:IUW:1W 3 EnclosureS: Sealed typeZ: Dust cover O: open type 4 Contact Current10:10A20:20A 5 Coil rated Voltage(V)DC:3,5,6,9,12,18,24 6 Coil power consumption1.0:1.0W1.2:1.2W Contact Data Contact Arrangement Contact Material Contact Rating (resistive) Max. Switching Power Max. Switching Voltage Contact Resistance or Voltage drop Operation Electrical life Mechanical 1ASPSTNO 1CSPDT(B-M) 1USPSTNODM 1WSPDTNC-NO AgSnO2 1A1C: 10A/120VAC,28VDC 20A/14VDC ; 1U: 2x10A/120VAC,28VDC 2x20A/14VDC ; 1W: 2x10A/120VAC,28VDC 2x20A/14VDC 1C: 280W 1200VA 1W: 2280W 21200VA 75VDC 380VAC Max. Switching Current:20A 50m Item 3.12 of IEC255-7 105 Item 3.30 of IEC255-7 107 Item 3.31 of IEC255-7 Coil Parameter Dash Numbers Coil voltage VDC Coil resistance 10% Pickup voltage VDC(max) (75%of rated voltage ) release voltage VDC(min) (10% of rated voltage) Rated Max. 003-1000 3 3.9 9 2.25 0.3 005-1000 5 6.5 25 3.75 0.5 006-1000 6 7.8 36 4.50 0.6 009-1000 9 11.7 85 6.75 0.9 012-1000 12 15.6 145 9.00 1.2 018-1000 18 23.4 324 13.5 1.8 024-1000 24 31.2 576 18.0 2.4 012-1200 12 15.6 120 9.00 1.2 Coil power consumption W Operate Time ms Release Time ms 1.0 10 5 1.2 10 5 CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay. 2.Pickup and release voltage are for test purposes only and are not to be used as design criteria. 115 www.dblectro.com 4117 Operation condition Insulation Resistance Dielectric Strength Between contacts Between contact and coil 100M min (at 500VDC) Item 7 of IEC255-5 50Hz 750V 50Hz 1500V Item 6 Item 6 Shock resistance Vibration resistance Terminals strength Solderability Ambient Temperature Relative Humidity Mass 100m/s2 11ms 10~40Hz double amplitude 10N 2352 30.5s -40~85 85% (at 40) 9g(Open type) 12g 1.27mm of IEC255-5 of IEC255-5 IEC68-2-27 Test Ea IEC68-2-6 Test Fc IEC68-2-21 Test Ua1 IEC68-2-20 Test Ta method 1 IEC68-2-3Test Ca Qualification inspection: Perform the qualification test as specified in the table of IEC255-19-1 and minimum sample size 24. Dimensions (Unit: mm) Mounting (Bottomz views) Dimensions Wiring diagram (Bottom views) mm 0.3 0.4 0.5 0.6 0.8 1.0 1.3 2.1 3.3 3.4 3.81 4.6 5.08 8.89 10.16 13.2 14 16.4 18 20 NOTES 1).Dimensions are in millimeter. 2).Inch equivalents are given for general information only. Reference Data www.dblectro.com >acCa 0.012 0.016 0.020 0.024 0.031 0.039 0.051 0.083 0.130 0.134 0.150 0.181 0.200 0.350 0.400 0.520 0.511 0.646 0.709 0.787