DATA SHEET CITILED COB Series Standard Type Ra97Typ. Super High CRI Model CLU028-1201C4 Introduction P 2 Performance Characteristics P 3 Mechanical Dimensions P 5 Characteristic Curves P 6 Reliability P 9 Packing Specification P 10 Precaution P 11 1 Ref.CE-P3782 11/16 Product Nomenclature CLU028 - 12 01 C4 - 27 3 H7 M5 - F1 [1] [2] [3] [4] [1] Product shape CLU028 [2] Die count in series 12 [3] Die count in parallel 01 [4] Nominal CCT 2700K [5] CRI (Ra) 97 Typ. [5] 1. Introduction 1-1. Product Description CITIZEN ELECTRONICS is the first COB manufacture. Our advanced knowledge and packaging technology for many years has excellent reliability and high quality of our products. CITILED COB Series covers a wide range of luminous flux from a 10W incandescent bulb to a 500W mercury lamp in general lighting sources. The element arrangement of LED package is capable of utilizing light more effectively and higher performance. The new version of CITILED COB Series succeed to reduce the thermal resistance significantly. New version creates more options to match luminaire's products design (ex. High performance , Cost effective , Higher lumen density , Increased allowable max. If). The outline and LES size is same since version 1. 3-step MacAdam ellipse color definition at Tj=85C is available. 1-2. Features Mechanical Dimensions Package Structure Reference Assembly CRI (Ra) Nominal CCT Chromaticity Range : : : : : : 13.5x13.5x1.4 (mm) Aluminum Base Chip on Board M3 screw, Connector 97 Typ. 2,700K, 3,000K, 4,000K 3-step MacAdam Ellipse, the center refers to ANSI C78.377:2011. 2-step MacAdam Ellipse, the center refers to ANSI C78.377:2011. : 2.6C/W : 230mA Thermal Resistance Maximum drive current RoHS compliant Better die arrangement for optics Wide range of luminous flux and high efficacy Improved lumen density compared with previous version UL recognized component (E358566) 2 Ref.CE-P3782 11/16 2. Performance Characteristics 2-1. Electro Optical Characteristics ( Tj=85C ) Luminous flux ( lm ) CRI Product code Nominal CCT T=85C Ra R9 Typ Typ. Min. Typ. Efficacy Forward ( lm/W ) Current T c=25C** ( mA ) Typ. Typ. Voltage ( V) Min. Typ. Max. Thermal Resistance Rj-c ( C/W ) CLU028-1201C4-27*H7M5-F1 2700K 97 90 303 345 383 113 90 31.2 34.0 36.8 2.6 CLU028-1201C4-30*H7M5-F1 3000K 97 90 315 358 397 117 90 31.2 34.0 36.8 2.6 CLU028-1201C4-40*H7M5-F1 4000K 97 90 322 367 407 120 90 31.2 34.0 36.8 2.6 Notes : 1. Citizen Electronics maintains a tolerance of 10% on luminous flux measurements. 2. Citizen Electronics maintains a tolerance of 3% on forward voltage measurements. 3. Citizen Electronics maintains a tolerance of 1 on Ra measurements. * : 2 = 2-step MacAdam ellipse , 3 = 3-step MacAdam ellipse **Values of Luminous flux at Tc=25C are provided as reference only. 2-2. Absolute Maximum Ratings Parameter Symbol Rating Input Power (W) Forward Current (mA) Reverse Current (mA) Operating Temperature (C) Storage Temperature (C) Case Temperature (C) Junction Temperature (C) Pi If Ir Top Tst Tc Tj 9.8 *1 230 *1 1 -40 ~ +100 -40 ~ +100 120 *2 150 *3 *1. Input power and forward current are the values when the LED is used within the range of the derating curve in this data sheet. *2. Refer to 3. Outline drawing for Tc measurement point. *3. D.C. Current : Tj = Tc + Rj-c x Pi 3 Ref.CE-P3782 11/16 2-3. Chromaticity Characteristics ( Rated current, Tj=85C ) Oval parameter Color Region Nominal CCT Center Point ( x, y ) 3-step MacAdam Ellipse. 2,700K ( 0.4577 , 0.4098 ) 3-step 0.00774 2-step 0.00516 3-step 0.00411 2-step 0.00274 3,000K ( 0.4339 , 0.4032 ) 0.00834 0.00556 0.00408 0.00272 53.17 4,000K ( 0.3818 , 0.3796 ) 0.00939 0.00626 0.00402 0.00268 54.00 2-step MacAdam Ellipse. Major Axis a Minor Axis b Ellipse Rotation Angle 57.28 * Color region stay within 3-step / 2-step MacAdam ellipse from the chromaticity center. * The chromaticity center refers to ANSI C78.377:2011. * is the angle between the major axis of the ellipse and the x-axis, and a and b are the major and minor semi-axes of an ellipse. ( Ref. IEC 60081:1997 AnnexD ) x-y chart CIE1931 0.45 3,000K 2,700K Black Body Locus 4,000K y 0.40 0.35 2-step 3-step 0.30 0.30 0.35 0.40 x 0.45 0.50 Note : Citizen Electronics maintains chromaticity ( x, y ) +/-0.005 4 Ref.CE-P3782 11/16 3. Mechanical Dimensions Unit : mm Tolerances unless otherwise specified : +/-0.3 Internal Circuit Marking 1 : Serial No. Marking 2 : T 12 01 ** ** Protection device CRI Anode Cathode CCT LED device Dies count in parallel Dies count in series 12 s 01 p Ver.6 5 Ref.CE-P3782 11/16 4. Characteristic Curves 4-1. Forward Current Characteristics / Temperature Characteristics Forward Current vs. Forward Voltage Forward Current vs. Relative Luminous Flux Tc=25C Tc=25C 40.0 Relative Luminous Flux [a.u.] 250% Vf [V] 38.0 36.0 34.0 32.0 30.0 200% 150% 100% 50% 0% 0 100 200 300 0 100 Case Temperature vs. Forward Voltage If=90mA Relative Luminous Flux [a.u.] 120% 36.0 Vf [V] 300 Case Temperature vs. Relative Luminous Flux If=90mA 37.0 200 If [mA] If [mA] 35.0 34.0 100% 80% 60% 40% 20% 0% 33.0 0 25 50 75 Tc [C] 100 0 125 25 50 75 Tc [C] 100 125 6 Ref.CE-P3782 11/16 4-2. Optical Characteristics Spectrum : CRI(Ra) 97 Typ. 4000K Tj=85C 3000K If=90mA 2700K 100% 90% Radiative Intensity 80% 70% 60% 50% 40% 30% 20% 10% 0% 380 430 480 530 580 630 680 730 780 Wave length [nm] 7 Ref.CE-P3782 11/16 4-2. Optical Characteristics (continued) Radiation Characteristic -40 -30 -20 10 -10 -50 100% 20 30 40 50 80% -60 -70 60% 60 40% 70 X 20% -80 Y -90 80 90 0% 4-3. Derating Characteristics Case Temperature vs. Allowable Forward Current 250 If [mA] 200 150 100 50 0 0 25 50 75 Tc [C] 100 125 8 Ref.CE-P3782 11/16 5. Reliability 5-1. Reliability Test Test Item Test Condition IF=90mA Continuous Operation Test Ta=25C (with Al-fin) x1000hrs IF=90mA Tj=150C (with Al-fin) x1000hrs Low Temperature Storage Test -40 C x 1000 hours High Temperature Storage Test 100 C x 1000 hours Moisture-proof Test 85 C, 85 %RH for 500 hours Thermal Shock Test -40 C x 30 minutes - 100 C x 30 minutes, 100 cycle 5-2. Failure Criteria ( Tc=25C ) Measuring Item Symbol Measuring Condition Failure Criteria Forward Voltage Vf If=90mA >U x 1.1 Total Luminous Flux v If=90mA